FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Similar documents
FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

KOMFORT EC DB Suspended heat recovery air handling units

SINGLE-ROOM VENTILATION. for schools and public spaces

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Series VENTS VUT R WH ЕС

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

AIR HANDLING UNIT WITH HEAT RECOVERY

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

HEAT RECOVERY AIR HANDLING UNIT

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Description of components and operating logic of the unit MICRA Ventilation system arrangement example based on the unit MICRA 60...

Small Room Heat Recovery Ventilation

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

HEAT RECOVERY AIR HANDLING UNITS

Heat recovery unit RDKS

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

PRODUCT RANGE: ROOFTOP PACKAGE

Turbo. Service Instructions

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Ventilation Unit Zehnder ComfoAir 350

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

10-year industry best core warranty. 5-year warranty on balance of unit.

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Air handling units with an integrated heat pump and rotary heat exchanger

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

TURBO HOODS. Product Brochure

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Flexit air handling units C2 and UNI 2, 3,4

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Lo-Carbon Sentinel Kinetic Horizontal

Heat Recovery Air Handling Units

Overview and Specifications

Zehnder ComfoAir 550. Ventilation unit

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

TECHNICAL SPECIFICATIONS

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

Ventilation unit Zehnder ComfoAir 200

Flexit air handling units UNI 2, 3 og 4

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

COMMERCIAL VENTILATION

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

UV-TURBO HOODS. Product Brochure

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

USER S MANUAL. VKP Series INLINE FAN

Outside Air Requirements... SOLVED!

Decentralised comfort ventilation unit Zehnder ComfoSpot 50

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

Residential Heat & Energy Recovery

Caution: The fans must not be used in bath or shower enclosures.

HEAT RECOVERY VENTILATOR

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

Limited Lifetime core warranty. 5-year warranty on balance of unit.

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Wind. Service instruction

Sentinel Demand Energy Recovery Ventilation

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Transcription:

FRESHBOX 100 Single-room heat recovery unit Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

FRESHBOX 100 CONTENTS FRESHBOX 100 FEATURES 3 DESIGN 4 OPERATING PRINCIPLE 6 CONTROL 6 APPLICATION OPTIONS 7 TECHNICAL DATA 8 OVERALL DIMENSIONS 8 ACCESSORIES 9 blaubergventilatoren.de 1

FRESHBOX 100 is a single-room energy-efficient supply and exhaust unit intended for decentralised ventilation of social and commercial spaces as well as apartments and houses. 2 FRESBOX 100 SINGLE-ROOM VENTILATION

FRESHBOX 100 The best solution for creating simple yet highly efficient ventilation systems in newly erected and renovated spaces without requiring ducting installation. FEATURES Efficient solution for supply and exhaust ventilation of enclosed spaces. Electric preheating or post-heating is available for cold climate conditions. Modification with a heat exchanger equipped with an enthalpy core is available for humid and hot climate conditions. Low-energy ЕС fans. Silent operation (25-38 db(a)). Supply air purification ensured by two built-in G4 and F8 filters (optionally H13). Upgradeable with an exhaust duct to provide air extraction from the bathroom. Easy installation. Compact size. blaubergventilatoren.de 3

DESIGN Casing Polymer coated metal casing decorated with an acrylic front panel. Heat and noise insulation is ensured by a layer of 10 mm cellular synthetic rubber. The front panel provides convenient access for filter maintenance and has a lock for extra security. The unit has two Ø100 mm pipes for fresh air intake and stale air extraction outside. The third Ø100 mm pipe (included in the scope of delivery) can be additionally fitted to the unit to connect the exhaust air duct from the bathroom. Motors The units feature efficient electronically commutated (ЕС) motors with an external rotor and impellers with forward curved blades. These state-of-the-art motors are the most advanced solution in energy efficiency today. EC motors are characterised with high performance and optimum control across the entire speed range. In addition to that the efficiency of electronically commutated motors reaches very impressive levels of up to 90 %. G4 extract air filter Plug Counter-flow heat exchanger Lock Air dampers The unit is equipped with supply and exhaust air dampers which activate automatically to prevent drafts while the unit is off. G4 intake air filter ЕН Freshbox 100 heater for condensate freeze protection (optional) Operation in a cold climate may result in condensate freezing in the exhaust air duct and the external hood. Therefore, it is recommended to install the ЕН Freshbox 100 heater (purchased separately) to prevent icing. Air filtration Supply air cleaning is provided by the G4 and F8 panel filters (PM2.5 > 75 %). To meet more stringent air purity requirements the F8 filter can be replaced with an H13 (PM2.5 > 95 %) (purchased separately). Exhaust air is cleaned by the panel filter G4. Preheater (Freshbox E-100) Supply air shutters with automatic actuator G4 Filter F8 Filter 4 FRESBOX 100 SINGLE-ROOM VENTILATION

FRESHBOX 100 Preheating Supply fan Freshbox E-100 units are equipped with an electric preheater which protects the heat exchanger from freezing. Post-heating Reheater (Freshbox E1-100) Freshbox E1-100 units feature an electric post-heater to raise the supply air temperature as necessary. Heat exchanger F8 supply filter Control panel The Freshbox 100 units are equipped with a counter-flow heat exchanger with a polystyrene core. In the cold season the exhaust air heat is captured and transferred to the supply air stream which reduces the ventilation-generated heat losses. Some condensate may form during heat recovery. The condensate is collected in the drain pan and is removed from the exhaust air duct. In the warm season the intake air heat is transferred to the extract air stream. This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load. Control unit Exhaust fan The Freshbox 100 ERV units are equipped with a counter-flow heat exchanger with an enthalpy membrane at the core. In the cold season the exhaust air heat and moisture are transferred to the supply air stream through the enthalpy membrane reducing the heat losses through ventilation. Consequently, it is the intake air heat and moisture transferred to the extract air stream through the enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the air conditioning load. Exhaust air shutters with automatic actuator Drain pan blaubergventilatoren.de 5

OPERATING PRINCIPLE The cold outdoor air passes through the filters and the heat exchanger and then is delivered to the serviced space by the supply centrifugal fan. To indoor Warm stale air from indoors passes through the filter and the heat exchanger and is discharged outdoors by the centrifugal fan. From indoor The supply and exhaust air flows are fully separated which helps eliminate the possibility of odour or microbial transfer between the streams. From a bathroom To indoor To outdoor From outdoor To outdoor CONTROL Operating principle with extra spigot for bathroom exhaust ventilation Freeze protection There are two types of freeze protection available to protect the heat exchangers in the cold season. The unit is equipped with a control panel. The remote control is supplied as standard. Functions Freshbox 100 Freshbox E-100 Freshbox E1-100 Speed changeover Filter replacement indication Alarm indication Speed setting Timer Weekly schedule Post-heating enabled/disabled Supply air temperature setup Freshbox 100 features an exhaust air temperature sensor downstream of the heat exchanger which disables the supply fan to let the warm extract air warm up the heat exchanger. After that the supply fan is turned on and the unit reverts to the normal operation mode. The Freshbox E-100 units are equipped with an electric preheater which warms up the supply air upstream of the heat exchanger to prevent its freezing. These features ensure a continuous balanced air exchange regardless of ambient air temperature variations. 6 FRESBOX 100 SINGLE-ROOM VENTILATION

FRESHBOX 100 APPLICATION OPTIONS Freshbox 100 Freshbox 100 application in an office space Each space requiring proper ventilation is equipped with one or several Freshbox 100 units. A single unit is capable of ensuring efficient ventilation in spaces with area up to 100 m². BlauPlast system Freshbox 100 Black VPR 100 Freshbox 100 application in a compact residential space The Freshbox 100 units can be upgraded with a bathroom exhaust air duct. To enable such a configuration the units can be additionally equipped with an optional Ø 100 mm spigot (supplied as standard). blaubergventilatoren.de 7

TECHNICAL DATA Parameters Freshbox 100 Freshbox 100 ERV Freshbox E-100 Freshbox E-100 ERV Freshbox E1-100 Freshbox E1-100 ERV Speed 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 Unit voltage [V /50-60 Hz] 1~230 1~230 1~230 1~230 1~230 1~230 Max. unit power without an electric heater [W] 12 21 45 12 21 45 12 21 45 12 21 45 12 21 45 12 21 45 Preheating power [W] 600 600 Post-heating power [W] 350 350 Max. current consumption w/o electric heater [A] 0,35 0,35 0,35 0,35 0,35 0,35 Max. current consumption with an electric heater [A] 3,08 3,08 1,94 1,94 Maximum air capacity [m³/h] 30 60 100 30 60 100 30 60 100 30 60 100 30 60 100 30 60 100 RPM [min 1] max 2200 Noise level @ 3 m [db(a)] 13 27 39 13 27 39 13 27 39 13 27 39 13 27 39 13 27 39 Max. transported air temperature [ C] from -25 up to +50 Casing material polymer coated steel Insulation thikness [mm] 10 Extract air filter Intake filter G4 + F8 (Option: F8 Carbon; H13) Connected air duct diameter [mm] 100 Weight [kg] 31 Heat recovery efficiency [%] 96 92 87 90 86 80 96 92 87 90 86 80 96 92 87 90 86 80 Heat exchanger type Heat exchanger material Energy efficiency class *Heat recovery efficiency is specified in compliance with EN 13141-8. polystyrene enthalpic membrane polystyrene G4 counter-flow А enthalpic membrane polystyrene enthalpic membrane Sound power level, A-filter applied Sound-power level, A - weighted General Octave frequency band [Hz] 63 125 250 500 1000 2000 4000 8000 Sound pressure level at 3 m., A-filter applied Sound pressure level at 1 m., A-filter applied LwA to environment [db(a)] 49 45 40 44 38 33 29 27 22 28 38 Static Static pressure pressure [Pa] [Pa] 0 5 10 15 20 25 250 0 5 10 15 20 25 250 200 200 150 150 100 100 50 50 Sound pressure level @ 1 m LpA [db(a)] 0 5 10 15 20 25 50 45 40 35 30 25 20 15 10 5 0 0 20 40 60 80 100 OVERALL DIMENSIONS [MM] Airflow [m³/h] 0 0 20 40 60 80 100 0 0 20 40 60 Airflow [m³/h] 80 100 Airflow [m³/h] 590 590 Ø100 200 200 Recovery Recovery eff. [%] eff. [%] 0 5 10 15 20 25 100 0 5 10 15 20 25 100 95 90 95 90 85 80 85 690 690 vel 1 m @ 1 m pa B(A)] [db(a)] 80 75 0 20 40 60 80 100 75 0 Freshbox 100 20 Freshbox 100 ERV Airflow [m³/h] 40 60 80 100 Freshbox 100 Freshbox 100 ERV Airflow [m³/h] 0 50 5 10 15 20 25 45 0 50 5 10 15 20 25 40 45 8 FRESBOX 100 SINGLE-ROOM VENTILATION 257 257 Ø100

FRESHBOX 100 ACCESSORIES Name Image Description MS Freshbox 100 chrome Mounting kit: Two Ø 100 mm air ducts, 500 mm long Ventilation outer hood made of polished steel Cardboard template MS Freshbox 100 white Mounting kit: Two Ø 100 mm air ducts, 500 mm long Ventilation outer hood, painted white Cardboard template AH Freshbox 100 chrome Ventilation outer hood made of polished steel. AH Freshbox 100 white Ventilation outer hood, painted white EH Freshbox 100 Heater to prevent condensate freezing in the drain pipe and outer ventilation hood FP 193x158x18 G4 PPI G4 Filter FP 193x158x47 F8 F8 Filter FP 193x158x47 F8 C F8 Carbon Filter FP 193x158x47 H13 H13 Hepa Filter HR-S Humidity sensor CD-1 CO₂ Sensor with LED lights for indication of CO₂ concentration and a touch button for operation mode switching CD-2 СО₂ Sensor blaubergventilatoren.de 9

Blauberg Ventilatoren GmbH Aidenbachstr. 52 D-81379 Munich info@blaubergventilatoren.de www.blaubergventilatoren.de Technical changes reserved. Illustrations and texts are non-binding. 03/2017