Heat pump systems and Chillers

Similar documents
> > > Heat pump systems. Water Chillers. Dehumidifiers

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

PRODUCT OVERVIEW. Dehumidifiers

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors

WZH Ground source heat pumps

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

LZA High efficiency air to water heat pumps with HP compressor

High efficiency air to water Heat pumps LZT series

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

ERGON EQUIPMENT SA PRESENTATION

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

PRODUCT GUIDE

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

HT V2 HT Split

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

The Energy Solutions of Withair Heat Pumps Catalogue 2017 Take Control of Your Energy Future!

SWIMMING POOL HEAT PUMPS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

1

Product Line Introduction. Karl Zhang Technical support engineer

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Conditioning your ambient, maximising your comfort.

Modular Air-cooled Chillers

S-Therm Air to Water Heat Pumps

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Process glycol chillers

LHA HIGH EFFICIENCY AIR TO WATER HEAT PUMPS SERIES TECHNICAL MANUAL


LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

CHAPTER 6 CONDENSING UNITS

H4T R410A. refrigerant

Air cooled industrial chillers

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

HVS, Hydro Variable System

50A KP 70A KP 90A KP 120A KP 150A KP 210A

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

ARS. 1

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

CRIMSON & CRIMSON MAX

Advance Split

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

COOLflow 4E PRODUCT RANGE


VIESMANN. VITOCAL Air/water heat pumps. Technical guide. VITOCAL 300-A Type AWC-I and AW-O. VITOCAL 350-A Type AWH-I and AWH-O

Heating with airborne and geothermal energy making the best possible use of renewables

BWL air heat pumps BWS brine heat pumps

HYDRONIC RESIDENTIAL

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Air Cooled Packaged Systems AIRAH Back to Basics

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Air Cooled Chillers & Heat Pumps WinPACK HE-A

kw COOLING kw HEATING

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Technical Information

Heat Pumps COMFORT NEED IT. When You

Integrated VarIable refrigerant flow ahu/pau (r410a)

Heat pumps. Heating systems Industrial systems Refrigeration systems

nemo a hp rcgroupairconditioning R410A

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

Technical data LA 60TUR+

Tower Green HE Hybrid

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

EN aquatech.piovan.com

Starting current with soft starter Fuse protection

Ground source heat pump range. Why Vaillant? because we can unearth the energy.

Conditioning your ambient, maximising your comfort.

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

Transcription:

PRODUCT OVERVIEW Heat pump systems and Chillers

HIdROS was formed in 1993 as a distribution company operating in the humidification and dehumidification sector of the air conditioning market. The expansion was rapid and, as the knowledge of the market sector increased, opportunities for the development of specialist products were identified. The decision was therefore taken in 21 to invest in a production facility and to manufacture their own design products. Since then, the company has added chillers, heat pumps and air handling units to its product portfolio. Today, HIdROS with its qualified staff, designs, develops and tests heat pumps, water chillers, dehumidifying systems and air handling units all based on the refrigerant cycle. The total range of Hidros products includes standard dehumidifiers with capacities from 25 to 3 l/24h and heat pumps and water chillers with cooling and heating capacities from 5 to 12 kw. In addition to this, HIdROS can offer a wide range of tailor made machines to meet any customer requirement. Expertise, quality, flexibility and enthusiasm are the other essential elements of the company that ensure we provide a rapid response with appropriately engineered solutions. 2

Heat pumps High efficiency air source and ground source heat pumps using state-of-the-art technology. Ranges from kw to 2 kw (air source) and 7 kw to 66 kw (ground/water source). Dehumidifiers Dehumidifiers for use in swimming pools, cold rooms, industrial applications and passive cooling systems. Water Chillers Air cooled and water cooled packaged chillers to 1 MW capacity for both external and internal installation. Free cooling, split condenser and condensing unit versions also available. www.hidros.eu

What is the E.V.I. Technology (Enhanced vapour injection) HIdROS LZTi, LZT, CZT, WZT, LWZ heat pumps utilise scroll compressors that are equipped with E.V.I. technology, a versatile method of improving system capacity and efficiency. stands for Economised Vapour Injection. The technology involves injecting refrigerant vapour into the middle of the compression process, a procedure that significantly boosts capacity and efficiency. Each scroll compressor used in these units is similar to a two-stage compressor with built-in inter-stage cooling. The process begins when a portion of the condenser liquid is extracted and expanded through an expansion valve. The low temperature liquid/gas mixture produced is injected into a heat exchanger that operates as a sub cooler. Any liquid is evaporated and the vapour produced is superheated. The superheated vapour is then injected into an intermediate port in the scroll compressor. This cold vapour reduces the temperature of the compressed gas thus enabling the compressor to raise the pressure to levels (and temperatures) beyond that possible with a single stage scroll. The additional sub cooling of the main volume of liquid refrigerant increases the evaporator capacity. This compressor technology generates a larger pressure ratio between condensing and evaporating pressures, with significant performance improvement. Using this technology enables Hidros units to produce hot water up to 65 C and the ability to operate down to -2 C ambient temperature. P m+i Defros ng system N. 21545966 Compressor Pi i i Injection Pm Condenser m + i Evaporator m h Expansion valve Versions P2U Version P2S Version This is a two pipe version that can produce hot water for heating (HH heating only) and hot or cold water in the RV version. The RV is used with two pipe water based change-over systems. It is not able to produce domestic hot water. This is a two pipe version that can, in addition to producing hot water for heating (HH version) and hot and cold water in the RV version can also generate domestic hot water. The controller has dual heating set points (heating and DHW) and can also control a three port diverting valve that directs the DHW to the cylinder. DHW production has priority irrespective of the mode of operation of the unit. The unit is normally used with two pipe water based change-over systems. 4

Noise Reduction All units in XL version are supplied, as standard, with the latest Floating Frame technology that completely isolates the compressors from the main casing, thereby eliminating vibration and noise from this source. The Floating Frame is a special vibration and acoustic damping system that consists of a base plate and acoustic enclosure that houses the compressors. The base plate is separated from the supporting frame of the unit by soft steel springs that have a high damping power. The entire arrangement provides a double damping system and acoustic attenuation. The compressor refrigerant pipes are connected to the fridge circuit via anaconda flexible connections. Flexible connections are also used on the water pipework within the unit. The combination of these systems results in an overall noise reduction in the region of -12 db(a). Technology Hidros heat pumps, in addition to being equipped with compressors technology (described above) are equipped with variable capacity compressor DC technology, an innovative technology that allows you to modulate the heating and cooling power supplied in accordance with the load changes required by the plant. This technology uses the latest generation brush less electric motors. The here below graph illustrates how this new technology of DC is able to follow the heat load of a building (blue line) unlike what makes an Heat Pump ON/OFF which increases the thermal input delivered with increasing temperature. The DC units also have very low inrush currents, which make them ideal for residential applications. Kw 18 16 14 12 8 6 4 2-2 -15 - -5 5 15 Outdoor ambient temperature ( C) ON/OFF Unit DC Unit Building loss P4U Version P4S Version - + The P4U units use 4 hydraulic connections and are used in modern 4-pipe systems. In these systems, cold and hot water is always available (in every period of the year) and present in the specific hydraulic circuit. These systems allow the simultaneous production of cold water and hot water using 4 hydraulic connections, 2 connections are related to the hot water circuit, 2 connections are related to the cold water circuit. The plant thus conceived is able to heat and, at the same time, if required, to cool with very high energy efficiencies. The P4S units have been designed to meet the needs of 2 + 2 pipe systems (2 user side pipes, 2 domestic hot water pipes) throughout the year. The units are supplied with 2 exchangers, one dedicated to the production of the user cold and hot water and one dedicated to the production of domestic hot water only (D.H.W.). The production of domestic hot water always has priority. www.hidros.eu

P4U Version The operating modes are: 1. User water heating: The unit behaves like a normal air/ water heat pump in heating mode, using the finned heat exchanger as the source and the A plate heat exchanger as user. 2. User water cooling: The unit behaves like a normal air / water chiller in cooling mode, using the finned exchanger as the source and the B plate heat exchanger as user. 3. Simultaneous user Cooling + heating: The unit behaves like a water / water heat pump, using the plate heat exchanger B as the cold user and the plate heat exchanger A as hot user. This version is not able to produce domestic hot water. User water heating User water cooling Simultaneous user Cooling + heating 35 C 3 C B A 7 C 12 C 7 C 12 C 35 C 3 C B A 2 sections unit WZT 2 sections unit XHA The air source high efficiency heat pumps WZT series are particularly suitable for those applications where it is necessary to have maximum efficiency in heating mode and a noise level extremely low and, for this purpose, are provided in two sections, linked together by refrigerant lines, installing the compressor in the internal section. The air/water heat XHA series pumps are supplied in two sections connected to each other through refrigerant lines, installing the compressor in the outdoor section. The units are designed for installations where it is not possible to use glycol in the hydraulic circuit or there is the real possibility of damage due to frost. All hydraulic components are present in the indoor unit, installed in the technical room. 6

P4S Version The operating modes are: 1. User water heating: The unit behaves like a normal air/ water heat pump in heating mode, using the finned heat exchanger as the source and the A plate heat exchanger as user. 2. User water cooling: The unit behaves like a normal air/water chiller in cooling mode, using the finned heat exchanger as the source and the A plate heat exchanger as user. 3. Domestic hot water production (D.H.W.): The unit behaves like a normal air / water heat pump in heating mode, using the finned heat exchanger as the source and as a user the plate heat exchanger B (a special D.H.W. heat exchanger that works with a higher set point). 4. User water cooling + D.H.W. production: The unit behaves like a water / water heat pump, using the plate heat exchanger A as the cold user and the plate heat exchanger B as D.H.W. production). User water heating User water cooling Domestic hot water production (D.H.W.) User water cooling + D.H.W. production 35 C 3 C A 7 C 12 C A 55 C 5 C B 55 C 5 C 7 C 12 C B A Hybrid version Hybrid version principle of operation 35 C E.V.I. 65 C -2 C + C The use of the water source heat exchanger only in harsh environmental conditions, allows the unit to operate with the air source for most of the time, integrating the power missing with the water but also ensuring an extreme reduction of water consumption. The applications of hybrid heat pumps are absolutely interesting in those cases where supplementary sources of different nature are available at lower cost. The integrated power from the water heat exchanger to water is about 3% of the power unit, in this way there are not needed high cost of adduction. Some water sources used: - Integrative source through the use of well water - Integrative source through the use of geothermal - Integrative source through the use of wastewater - Integrative source through the use of solar panels. www.hidros.eu

LZT i R4A DC R134a -2 C -15 C +63 C -2 C Heat pumps air to water -15 C DC R47C compressor with vapor injection () +63 C DC +43 C +65 C +58 C +65 C DC +43 C STD 2 pipes reversible standard. SW6 4 pipes unit capable +58 Cof producing hot DC and cold water at the same time on two independent DC hydraulic circuits. +65 C A ++ A ++ Operation limits (All versions) 7 6 5 4 3 2-2 - 2 3 4 5 (RV versions Only) 3 2 - -2-2 - 2 3 4 5 Heating mode and glycol and glycol (1) Heating: Ambient temperature 7 C DB, 6 C WB, water temperature 3/35 C. (2) Cooling: ambient temperature 35 C, water temperature 12/7 C. 8 LZTi - LZTi/SW6 Models 8 15 2 Energy Class in low temperature - According to EU reg. 811/213 A++ A++ A++ A++ Energy Class in high temperature - According to EU reg. 811/213 A+ A+ A++ A++ kw 7,7 9,6 15, 19, w/w 4,3 4,2 4,4 4,2 kw 7,1 8,5 13,5 16, w/w 3,1 3, 3,2 3,1

A ++ LHA High efficiency air to water heat pumps R47C R4A -2 C +43 C R134a +6 C DC HH Heating only. RV Reversible heating/cooling. DC LS Low noise. XL DC Super low noise. P2U 2 pipe systems without domestic hot water production. P2S 2 pipe systems with domestic hot water production by external 3 way valve. P4U 4 pipe systems heating/cooling. P4S 2+2 pipe systems with domestic hot water production. Operation limits 7 6 5 4 3 (All versions) 3 25 2 15 5 (RV versions Only) Heating mode and glycol 2-2 - 2 3 4 5-2 - 2 3 4 5 LHA/LS/RV - Low noise Reversible version 252 32 42 452 52 62 72 82 92 2 122 142 Energy Class in low temp. - According to EU reg. 811/213 A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ kw 22,2 29,6 37,6 47,7 52,2 61,2 67,3 74,9 93,2 4,9 114,9 137,1 w/w 4, 4,16 4,45 4,28 4,55 4,61 4,46 4,36 4,4 4,29 4,13 4,44 kw 18,1 24,6 3,9 4,6 45,4 52,4 57,5 63,4 8,5 9,2,5 117,4 w/w 2,62 2,59 2,92 2,82 2,94 2,87 2,7 2,65 3,3 2,89 2,86 3,4 LHA/LS/RV - Low noise Reversible version 162 182 22 232 252 254 34 324 354 44 454 54 Energy Class in low temp. - According to EU reg. 811/213 A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ kw 151, 167,9 182,8 2,6 241,3 229,4 271,4 296,7 339, 364,9 47, 463,7 w/w 4,39 4,18 4,2 4,26 4,4 4,11 4,25 4,15 4,5 4,11 3,91 4,3 kw 129,5 146,8 159,2 18,4 22,1 198,5 231, 259,7 289,4 322,6 368,5 416, w/w 2,94 2,89 2,71 2,73 2,76 2,73 2,87 2,91 2,75 2,73 2,73 2,69 (1) Heating: Ambient temperature 7 C DB, 6 C WB, water temperature 3/35 C. (2) Cooling: ambient temperature 35 C, water temperature 12/7 C. www.hidros.eu

LZT R47C R4A -2 C High efficiency air to water -15 Cheat pumps with E.V.I. compressors -2 C +63 C +43 C +65 C A ++ A + R134a -15 C +63 C DC +58 C +65 C +43 C HH Heating only. RV Reversible heating/cooling. XL Super +58 C low noise. DC NN Ultra low noise. P2UDC 2 pipe DC systems without +65 C domestic hot water pro- duction. P2S 2 pipe systems with domestic hot water production by external 3 way valve. P4U 4 pipe systems heating/cooling. P4S 2+2 pipe systems with domestic hot water production. Operation limits (All versions) 7 6 5 4 3 2-2 - 2 3 4 5 (RV versions Only) 3 2 - -2-2 - 2 3 4 5 Heating mode and glycol and glycol LZT/RV - Reversible version 252 32 452 52 62 752 852 Energy Class in low temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ A+ Energy Class in high temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ A+ kw 25,5 32,1 41,8 52,8 63,7 72,8 83, w/w 4,25 4,21 4,18 4,16 4,29 4,27 4,15 kw 22,4 27,7 36,7 46,2 54,7 62,8 71, w/w 3,6 3,5 3,7 3,5 3,7 3,5 3,5 LZT/RV - Reversible version 2 122 154 174 24 244 Energy Class in low temp. - According to EU reg. 811/213 A+ A+ A++ A++ A+ A+ Energy Class in high temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ kw 93,2 1,5 149, 161, 183, 2, w/w 4,14 4,2 4,3 4,23 4,28 4,2 kw 79,4 9, 126, 14, 165, 186, w/w 2,95 2,93 3,1 2,85 3,14 2,9 (1) Heating: Ambient temperature 7 C DB, 6 C WB, water temperature 3/35 C. (2) Cooling: ambient temperature 35 C, water temperature 12/7 C.

A + A + CZT R47C R4A R134a High efficiency air to water heat pumps ductables with E.V.I. compressors -2 C +43 C +65 C -15 C +63 C DC HH Heating only. +43 C RV Reversible heating/cooling. XL Super +58 C low noise. DC P2U 2 pipe systems without domestic hot water production. P2SDC 2 pipe DCsystems +65 C with domestic hot water production by external 3 way valve. P4U 4 pipe systems heating/cooling. P4S 2+2 pipe systems with domestic hot water production. Plant scheme CZT/RV - Reversible version 252 32 452 52 62 752 Energy Class in low temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ Energy Class in high temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ kw 25,7 32,2 43,1 54,9 63, 72,8 w/w 4,15 4,12 4, 4,15 4,12 4,11 kw 22,4 27,7 36,5 46, 54,5 62,5 w/w 2,93 2,85 2,75 2,7 2,95 2,94 Performances are obtained with available static pressure 5 Pa, at the following conditions: (1) Heating: Ambient temperature 7 C DB, 6 C WB, water temperature 3/35 C. (2) Cooling: ambient temperature 35 C, water temperature 12/7 C. www.hidros.eu

XHA R47C R4A High Efficiency air to water split system heat pumps with E.V.I. Compressors -2 C +43 C +6 C A + R134a DC -15 C +63 C +43 C HH Heating only. RV Reversible heating/cooling. +58 C DC LS Low noise. XL DC Super low noise. DC +65 C P2U2 pipe systems without domestic hot water production. P2S 2 pipe systems with domestic hot water production by external 3 way valve. Operation limits (All versions) 7 6 5 4 3 2-2 - 2 3 4 5 (RV versions Only) 3 2 - -2-2 - 2 3 4 5 Heating mode and glycol and glycol (1) Heating: Ambient temperature 7 C DB, 6 C WB, water temperature 3/35 C. (2) Cooling: ambient temperature 35 C, water temperature 12/7 C. 12 XHA/LS/RV - Low noise Reversible version 252 32 42 452 52 62 72 82 Energy Class in low temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ A+ A+ kw 25,4 34,2 4,2 48,1 56,6 65,1 74,7 82, w/w 4,4 4,4 4,5 4,2 4,4 4,5 4,3 4,3 kw 19,2 26,8 31,1 39,2 45,2 52, 62,9 69,1 w/w 2,76 2,86 2,65 2,86 2,86 2,86 3,7 3,7 XHA/LS/RV - Low noise Reversible version 92 2 122 142 162 182 22 Energy Class in low temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ A+ kw 99,5 112,1 123,7 143,9 158,3 177,1 192,1 w/w 4,4 4,4 4,4 4,3 4,3 4,3 4,2 kw 79,6 89,1 97,7 113,8 128,1 141,6 153,5 w/w 2,97 2,86 2,76 2,97 2,97 2,86 2,65

WZT R47C R4A -2 C -15 C +63 C +43 C High Efficiency air to water split system heat pumps with E.V.I. Compressors +58 C -2 C +43 C +65 C A + A + -15 C R134a +63 C +43 C DC HH Heating only. RV Reversible heating/cooling. +58 C DC NN Super low noise. P2UDC 2 pipe systems without domestic hot water DC +65 C production. P2S 2 pipe systems with domestic hot water production by external 3 way valve. P4U 4 pipe systems heating/cooling. P4S 2+2 pipe systems with domestic hot water production. Operation limits (All versions) (RV versions Only) 7 6 5 4 3 2-2 - 2 3 4 5 3 2 - -2-2 - 2 3 4 5 Heating mode and glycol and glycol WZT/RV - Reversible version 252 32 452 52 62 752 852 2 Energy Class in low temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ A+ A+ Energy Class in high temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ A+ A+ kw 23,6 29,7 38,5 52,6 58,3 66,8 8,4 9,9 w/w 4,15 4,12 4,13 4,25 4,28 4,2 4,27 4,3 kw 21,4 26,5 35,6 45,7 53,5 61,1 69, 79,3 w/w 2,64 2,51 2,52 2,82 2,87 2,71 3,1 3,5 (1) Heating: Ambient temperature 7 C DB, 6 C WB, water temperature 3/35 C. (2) Cooling: ambient temperature 35 C, water temperature 12/7 C. www.hidros.eu

-2 C LWZ R47C R4A -15 C +63 C High efficiency HYBRID heat pumps +43 C with E.V.I compressor +58 C -2 C +43 C +65 C A + A + R134a -15 C +63 C DC +43 C HH Heating only. RV Reversible heating/cooling. +58 C DC XL Super low noise. NNDC Ultra low noise. DC +65 C P2U 2 pipe systems without domestic hot water production. P2S 2 pipe systems with domestic hot water production by external 3 way valve. P4U 4 pipe systems heating/cooling. P4S 2+2 pipe systems with domestic hot water production. Operation limits (All versions) (RV versions Only) 7 6 5 4 3 2-2 - 2 3 4 5 3 2 - -2-2 - 2 3 4 5 Heating mode and glycol and glycol LWZ/RV - Reversible version 252 32 452 52 62 752 852 Energy Class in low temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ A+ Energy Class in high temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ A+ kw 16,6 21,2 27,5 34,2 41,9 48,3 53,5 w/w 2,71 2,75 2,78 2,82 2,76 2,8 2,68 kw 22,4 27,7 36,7 46,2 54,7 62,8 71, w/w 3,6 3,5 3,7 3,5 3,7 3,5 3,5 LWZ/RV - Reversible version 2 122 154 174 24 244 Energy Class in low temp. - According to EU reg. 811/213 A+ A+ A++ A++ A+ A+ Energy Class in high temp. - According to EU reg. 811/213 A+ A+ A+ A+ A+ A+ kw 61, 72,3 99,2 6,3 12,9 138,5 w/w 2,65 2,73 2,84 2,79 2,84 2,76 kw 79,4 9, 126, 14, 165, 186, w/w 2,95 2,93 3,1 2,85 3,14 2,9 (1) Heating: Ambient temperature -7 C DB, -8 C WB, water outlet temperature 35 C. Integrative source heat exchenger not activated. (2) Cooling: ambient temperature 35 C, water temperature 12/7 C. Integrative source heat exchenger not activated. 14

A ++ A ++ WZA Ground source water/water heat pumps R4A +6 C HP HH RV P4S Heating only. Reversible heating/cooling. 2+2 pipe systems with domestic hot water production. Operation limits User outlet water temp. ( C) 7 6 5 4 3 2-3 -2-2 3 4 Source outlet water temp. ( C) WZA 6 8 12 16 2 24 33 Energy Class in low temp. - According to EU reg. 811/213 A++ A++ A++ A++ A++ A++ A++ Energy Class in high temp. - According to EU reg. 811/213 A++ A++ A++ A++ A++ A++ A++ kw 7,6 9,8 13,3 16,9 22,4 26,4 33,5 w/w 5,4 5,13 5,21 5,3 5,18 5,28 5,28 kw 6,2 8,1,9 14, 18,5 21,8 27,6 w/w 4,2 4,3 4,37 4,47 4,33 4,44 4,42 (1) Heating: user water temperature 3/35 C, source water temperature /7 C. (2) Cooling: user water temperature 12/7 C, source water temperature 3/35 C. www.hidros.eu

A ++ A ++ WHA Ground source water/water heat pumps R4A +6 C HH Standard, heating only. RV Reversible heating/cooling. SW5 Heating only + domestic hot water circuit. RV/SW6 Reversible version heating/cooling with independent DHW circuit. FC Free cooling (available in all versions). Operation limits User outlet water temp. ( C) 7 6 5 4 3 2-15 - -5 5 15 2 Source outlet water temp. ( C) User outlet water temp. ( C) 2 15 5-5 - 2 25 3 35 4 45 5 55 6 Source outlet water temp. ( C) Heating Heating with glycol source circuit Cooling Cooling with glycol user circuit Operating limits with 5 C Δt WHA/RV - Reversible version 39 45 5 6 7 8 9 1 12 Energy Class in low temp. - According to EU reg. 811/213 A++ A++ A++ A++ A++ A++ A++ A++ A++ Energy Class in high temp. - According to EU reg. 811/213 A++ A++ A++ A++ A++ A++ A++ A++ A++ kw 51,7 59, 71,2 8, 92,5 5,9 12,8 136,1 152, w/w 5,3 5,4 5,7 5,6 5,5 5,5 5,4 5,5 5,4 kw 42,9 49, 6,3 67,4 77,5 88,9 1,3 114,3 126,9 w/w 4,3 4,3 4,7 4,6 4,4 4,5 4,5 4,5 4,4 Free cooling capacity (3) kw 22,8 22,9 36, 36,3 36,6 49,3 71, 72,4 73,5 WHA/RV - Reversible version 13 152 162 19 2 24 26 3 32 Energy Class in low temp. - According to EU reg. 811/213 A++ A++ A++ A++ A++ A++ A++ A++ A++ Energy Class in high temp. - According to EU reg. 811/213 A++ A++ A++ A++ A++ A++ A++ A++ A++ kw 169,2 195, 222,1 243,8 271,3 36,9 342,2 39,9 439,4 w/w 5,4 5,3 5,4 5,4 5,3 5,3 5,4 5,4 5,4 kw 141,2 163,6 187,4 25,1 226,9 257,3 287,4 328,1 368,5 w/w 4,4 4,3 4,4 4,4 4,3 4,4 4,4 4,4 4,4 Free cooling capacity (3) kw 74,1 93,1 94, 128,2 129,6 13,9 163, 164,4 23, (1) Heating: user water temperature 3/35 C, source water temperature /7 C. (2) Cooling: user water temperature 12/7 C, source water temperature 3/35 C. (3) Free Cooling: user water temperature C, source water temperature 2 C, compressors OFF. 16

LDA Air cooled water chillers with axial fans R4A CO SA SE HA HE LS XL BT Cooling only. Standard efficiency, AC fans. Standard efficiency, EC fans. High efficiency, AC fans. High efficiency, EC fans. Low noise. Extra low noise. Cooling only for low user water temperature. Operation limits 3 2 - -2-2 - 2 3 4 5 and glycol and glycol LDA/CO/HE/LS 252 32 42 452 52 62 72 82 92 2 122 142 Cooling capacity (EN14511) (1) kw 19,7 26,7 32,3 42,8 46,9 55 61,6 68,6 82,6 93,8 5 121,6 Total input power (EN14511) (1) kw 6,2 8,4,1 13,6 14,6 16,9 19,3 21,8 25,4 29,6 33,2 36,8 EER (EN14511) (1) W/W 3,16 3,18 3,2 3,15 3,21 3,25 3,19 3,15 3,25 3,17 3,16 3,3 SEER (2) kwh/kwh 4,2 4,25 4,35 4,29 4,26 4,39 4,31 4,24 4,37 4,34 4,25 4,4 LDA/CO/HE/LS 162 182 22 232 252 254 34 324 354 44 454 54 Cooling capacity (EN14511) (1) kw 133,3 152,1 169,3 195,6 215,1 2,3 246,8 267,7 33,2 345,3 39 435,5 Total input power (EN14511) (1) kw 41,8 48,1 53,6 62,7 68,3 66,3 76,2 85, 95,3 8,2 123,8 138,3 EER (EN14511) (1) W/W 3,19 3,16 3,16 3,12 3,15 3,17 3,24 3,15 3,18 3,19 3,15 3,15 SEER (2) kwh/kwh 4,42 4,41 4,31 4,4 4,28 4,25 4,36 4,32 4,41 4,28 4,43 4,4 (1) Cooling: ambient air temperature 35 C, evaporator water temperature in/out 12/7 C. (2) In accordance with (EU) 216/2281 and relative norms part of this. www.hidros.eu

WDA Water cooled water chillers R4A STD HP EV BT RP Cooling only. Reversible version on the hydraulic circuit. Condenserless. Cooling only version for low user water temperature. Cooling only version with partial heat recovery. Operation limits User water outlet temperature ( C) 6 5 4 3 2-2 3 4 5 6 7 Source water inlet temperature ( C) User water inlet temperature ( C) 6 5 4 3 2-2 3 4 5 6 7 Source water outlet temperature ( C) Only HP All versions Only BT versions (working mode with glycol) WDA - WDA/HP 39 45 5 6 7 8 9 1 12 13 Energy Class in low temp. - Accord. to EU reg. 811/213 A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ Cooling capacity (EN14511) (1) kw 43,7 49,9 59,3 67,2 75, 88,5,8 112, 126,5 141,1 EER (EN14511) (1) w/w 4,2 4,1 3,9 4, 4,2 4,2 4,2 4,2 4,1 4,2 Heating capacity (EN14511) (2) kw 48,8 55,9 65,8 74, 83,8 98,5 118,3 132,8 149,8 166,6 COP (EN14511) (2) w/w 4,6 4,7 4,8 4,7 4,9 4,8 4,9 4,9 4,9 4,9 WDA - WDA/HP 152 162 19 2 24 26 3 32 38 43 5 Energy Class in low temp. - Accord. to EU reg. 811/213 A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ Cooling capacity (EN14511) (1) kw 162,4 182,5 21,6 223,9 257,6 285,7 323,5 365,2 421,1 474,2 535,1 EER (EN14511) (1) w/w 4,2 4,2 4,2 4,2 4,2 4,2 4,2 4,2 4,1 4,2 4,2 Heating capacity (EN14511) (2) kw 19,9 216,5 237,4 266,4 31,4 325,9 367,7 422,4 51, 567,1 637,2 COP (EN14511) (2) w/w 4,9 5, 4,9 4,9 4,9 4,8 4,8 4,9 4,9 4,9 5, (1) Cooling: Evaporator water temperature in/out 12/7 C condenser water temperature in/out 3/35 C. (2) Heating: condenser water temperature in/out 3/35 C; evaporator water temperature in/out /7 C. 18

WTS Water cooled water chillers R47C R4A R134a WTS In this version the units are supplied complete with water tank, primary circuit water pump. WTS/FC In this version the units are supplied complete with water tank, primary circuit water pump, intermediate plate heat exchanger and 3 way DC valve ( used to modulates the water flow to the user circuit following the required load from the plant). During the free cooling mode the compressors are in off. RD US IN US OUT SO OUT SO IN E1NTU WT WT A1NTP EV V3 CP1 CP2 CP3 CP4 VTEE VTEE CN FC E1NTS V1 V2 US IN US OUT SO IN SO OUT V1, V2, V3 VTEE CP 1,2,3,4 EV CN WT FC E1NTU E1NTS A1NTP RD User circuit water inlet User circuit water outlet Source circuit water inlet Source circuit water outlet Water valves Electronic expansion valve Compressor User heat exchanger Source heat exchanger Water tank Free cooling heat exchanger User circuit water pump Source circuit water pump Primary circuit water pump Remote dry cooler WTS/FC - Free cooling version Cooling capacity (EN14511) (1) EER (EN14511) (1) Free cooling capacity (2) WTS/FC - Free cooling version Cooling capacity (EN14511) (1) EER (EN14511) (1) Free cooling capacity (2) 39 45 5 7 8 9 12 13 kw 39,46 44,99 55,19 7,34 8,58 92,4 116,42 129,79 w/w 3,22 3,19 3,45 3,3 3,38 3,39 3,32 3,32 kw 28, 34, 43, 54,8 62,8 72, 87, 1, 152 162 19 2 24 26 3 32 kw 152,85 175, 181,13 22,15 232,28 262,9 34,59 341,85 w/w 3,39 3,49 3,32 3,25 3,34 3,41 3,45 3,44 kw 116, 13, 141,3 157,5 172, 22, 232, 255, (1) Cooling: User water temperature in/out 12/7 C, source water temperature in/out 36/42 C. With 35% ethylen glycol. (2) Free Cooling: Source inlet water temperature +2 C, user water temperature in/out 14/9 C. www.hidros.eu

BRCP.18GB.A Technical data shown in this booklet are not binding. HIdROS Srl shall have the right to introduce at any time whatever modifications necessari to the improvement of the product.