S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

Similar documents
BATHROOM EXTRACT FANS SILENT-100 Series

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

KITCHEN EXTRACTORS K Series

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

Fig.2. Fig.3. Fig.4 L N L N

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

Ventilation. Axial Fans Centrifugal Fans Low Voltage Fans Shower Fans Commercial Fans Flexible Ducting Fixing Kits External Grilles Hand Dryers

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Domestic & Commercial Fans

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Ventilation and Hand Dryers

Mini fans MiniVent M1/100

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

ECO dmev Decentralised MEV

Chrome. Approximately 26 seconds drying time. 1.0kW Automatic Eco Fast Dryer Epoxy Coated. 1.2mm thick steel cover

Specification. for Sapphire 100mm & 150mm Energy Efficient Axial Fans. Domus Ventilation

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Caution: The fans must not be used in bath or shower enclosures.

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series

Silhouette Installation and Wiring Instructions

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

BATHROOM HEATER & EXHAUST RANGE

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

ACCESSOIRES ELECTRICAL ACCESSORIES

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

SINGLE PHASE RANGE BD BD 19/19 M4 1/5 BD 19/19 M6 1

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Centrifugal extract and condensation control fans

GUIDELINES FOR A CORRECT VENTILATION

RAPID RESPONSE. Quiet Operation. Powerful Performance. Header Box Exhaust Fan

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS.

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Our quietest bathroom fan. Fact.

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT

The quietest bathroom fan. Fact.

CATA WORLDWIDE In over 80 countries

BATHROOM 2017 HEATING CATALOGUE

SLIMAIRE 230V & 12V SINGLE SPEED FANS

Installation & Operating Instructions

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

(57.7) X. March 2006 PRODUCTS. ... the complete solution

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

SAX. Window & Wall Fans

G Installation manual Solitude - dmev unit

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

POWERCUBE - CENTRAL EXTRACT SYSTEM

5 year fan housing and motor warranty

KADO LUX LED EXHAUST FAN 200

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

Fig.2. Fig.3. Fig.4 L N L N

JLBIHD624 60cm Cooker Hood

Model with intellectual humidity control and extra motion sensor control

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

The Straight Way K Sileo Series

Bathroom Ventilation Guide

VENTILATION SOLUTIONS

CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.

PA 500/1100V Ultra Quiet Ventilation Fan

HAND DRYERS

CONTENT: VEX308 Decentralised ventilation VEX308

A GUIDE TO SELECTING THE RIGHT FAN

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

Short Form Ventilation Product Guide

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

SELECTION GUIDE AIR PURIFICATION AND CENTRALISED MECHANICAL EXHAUST VENTILATON

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

Healthy, comfortable and energy-efficient ventilation

CENTRALISED MECHANICAL EXTRACT RESIDENTIAL VENTILATION AND AIR PURIFICATION

The Complete Range of Hand Dryers

World-class small room fans. Premium design with highest energy efficiency.

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

Installation & Operating Instructions

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Myth & Reality of Basement Ventilation

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Fig.2. Fig.3. Fig.4 L N L N

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Plus Perimeter Aspiration Timer Remote control predisposition

Transcription:

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE The Quietest Extractors in the World in their Category Lp 26,5 db

AXIAL FLOW FANS Series -1-1 16182 6376-2 -3 NEW Installation examples Axial fl ow fans for wall or ceiling installation, designed to solve ventilation problems in small rooms and bathrooms. The motors from the range are mounted on silent-elastic-blocks which absorb the vibrations. In this way not only is the noise from the extractor signifi cantly reduced but so too is the noise from the surface which supports it. Additionally, the motors from the range are equipped with ball bearings which guarantee long life working (more than 3. working hours) at any shaft positions. The range consists of three different models: -1, -2 and -3, available with different integrated control options to accommodate all application requirements. C All models are fi tted with back draft shutter. Ceiling or wall mounted with directly to the outside or through duct system Z R All models includes ball bearings greased for life (up to 3. hours). Model fi tted with an adjustable period Run-On-Timer keeping the fan in operation for the pre set period of time after the fan has been switched off. H Model with an adjustable humidistat. Extract fan can de mounted in a shunt ventilation system Extract ventilation through double walls by means of an accessory (-1) D Model provided with a passive infra-red detector operating up to 4 m from the fan. 569

BATHROOM EXTRACT FANS -1 Series Range of axial extractors with airfl ow rates of approx. 1 m3/h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow offering very low noise level. All the fans are manufactured from injection moulded plastic, fi tted with automatic shutter and single phase 23V-5Hz, class B low consumption motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperature up to 4ºC. Lp 26,5 db Low noise! consumption 8W! Water protected! Energy efficient! SILVER versions The -1 CZ and CRZ can be supplied with an aesthetical silver front grille. Back draft shutter Silent-blocks Quiet operation To prevent air entry and limit heat leakage when the extractor is not operating. It opens due to the pressure of the air Motor mounted on Silent-elastic-block to prevent vibration and noise transmission -1 Usual extractor In usual extract fans the vibrations are transmitted to the surrounding areas while in extractor fans the vibrations are absorbed by the Silent Blocks 57

Models features CZ CRZ CRIZ CHZ CHZ VISUAL CDZ CZ (12V) CZ SILVER CRZ SILVER CHZ SILVER CZ(12V) SILVER Pilot light Backdraft shutter Adjustable Run-On-Timer (1-3min) * * Automatic timer Adjustable humidistat Detector movement Ball bearings Silver colour * Using CT-12/14R transformer Technical characteristics Performance curves Model Speed (r.p.m.) Abs. power at free (W) Voltage (V) 5 Hz Sound pressure level* (db(a)) Airflow at free (m3/h) Insulation/ IP Weight (kg) P Pa mmcda 4 4-1 -1 24 8 23 26,5 95 II / IP45,57-1 12V 232 13 12 26,5 95 / IP57,57 * Sound pressure level measured at 3 m at free air conditions. Dimensions (mm) 35 3 25 2 3,5 3 2,5 2 15 1,5 1 1 5,5 2 4 6 8 1..1.2 m 3 /h Q m 3 /s Accessories GSA-1 Flexible aluminium ducting GRA-7 Aluminium exterior grille CX-8/125 Worm drive ducting clip PER-1W Back draft shutter WALL KIT Fixed shutter and telescopic duct (2 to 42 m) WINDOW KIT 571

-1 models with special functions Model SELV (Safety Extra Low Voltage). Specially designed to operate within the shower or bath volume with total safety. They are rated 12V, Class III and IP57. -1 CZ 12V -1 12V must be wired to a safety isolating transformer CT-12/14 which must be located out of the reach of the water spray or person using a bath or shower. The transformer is IP21, class II insulation and protected by fuse. Also available, Transformer CT12/14 R, supplied with adjustable run-on-timer between 1 to 3 minutes. KIT -1 CZ 12V + CT Kit integrated by an extractor -1 CZ 12V and a safety isolating transformer CT-12/14. Model provided with a PIR (passive infra-red) detector. The unit starts automatically when a movement is detected within a maximum distance of 4 meters from the fan. They are also fi tted with an adjustable run on timer, from 1 to 3 minutes, to allow the fan continues operating after the initiation of the movement detection. -1 CDZ -1 CHZ VISUAL Models provided with an electronic humidistat which can be adjusted to 6, 7, 8 or 9% HR using a key situated on the front grille. Four luminous indicators show the desired level of humidity. The extractor operates automatically when the humidity level in the room is higher than the set level. The extractor will stop automatically when the humidity drops below the selected level and after the selected period set on the adjustable timer (1 and 3 minutes). 572

BATHROOM EXTRACT FANS -1 Series NEW Range of axial extractors with airfl ow rates of approx. 8 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow offering very low noise level. All the fans are manufactured from injection moulded plastic, fi tted with automatic shutter and single phase 23V-5Hz, class B low consumption motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperature up to 4ºC. Lp 26,5 db Low noise! Water protected! consumption 8W! Energy efficient! SILVER versions can be supplied with an aesthetical silver front grille. Back draft shutter Silent-blocks Quiet operation Kit 3 front panel trims To prevent air entry and limit heat leakage when the extractor is not operating. It opens due to the pressure of the air Motor mounted on Silent-elastic-block to prevent vibration and noise transmission -1 Usual extractor In usual extract fans the vibrations are transmitted to the surrounding areas while in extractor fans the vibrations are absorbed by the Silent Blocks Interchangeable front panel trims let the fan blend in with every setting: Transparent blue evokes the colour of water. 3 other colours to match the decor of the room 573

Models features CZ CRZ CHZ CZ SILVER CRZ SILVER CHZ SILVER CZ CRZ CHZ CZ SILVER CRZ SILVER Pilot light Backdraft shutter Adjustable Run-On-Timer (1-3min) Adjustable humidistat Ball bearings Silver colour kit 3 front panel trims CHZ SILVER Technical characteristics Performance curves Model * Sound pressure level measured at 3 m at free air conditions. Dimensions (mm) Abs. power at free (W) Voltage (V) 5 Hz Sound pressure level* (db(a)) Airflow at free (m3/h) Insulation/ IP Weight -1 8 23 26,5 8 II / IP45,65 188 129,5 84,6 79 (kg) P Pa mmcda 24 2,4 21 2,1 18 1,8 15 1,5 12 1,2 9,9-1 6,6 188 Ø98,9 3,3 2 4 6 8..1.2 m 3 /h Q m 3 /s Accessories GSA-1 Flexible aluminium ducting GRA-7 Aluminium exterior grille CX-8/125 Worm drive ducting clip PER-1W Back draft shutter WALL KIT Fixed shutter and telescopic duct (2 to 42 m) WINDOW KIT 574

BATHROOM EXTRACT FANS -2 Series Range of axial extractors with airfl ow rates of approx. 18 m 3 /h, for connection to 12 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow offering very low noise level. All the fans are manufactured from injection moulded plastic, fi tted with automatic shutter and single phase 23V-5- Hz, class B low consumption motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperature up to 4ºC. The -2 CZ and CRZ can be supplied with an aesthetical silver front grille. Back draft shutter Silent-blocks Quiet operation To prevent air entry and limit heat leakage when the extractor is not operating. It opens due to the pressure of the air Motor mounted on Silent-elastic-block to prevent vibration and noise transmission -2 Usual extractor In usual extract fans the vibrations are transmitted to the surrounding areas while in extractor fans the vibrations are absorbed by the Silent Blocks Models features CZ CRZ CHZ CZ SILVER CRZ SILVER CHZ SILVER Pilot light Backdraft shutter Adjustable Run-On-Timer (1-3min) Adjustable humidistat Ball bearings Silver colour Technical characteristics Model Speed (r.p.m.) Abs. power at free (W) * Sound pressure level measured at 3 m at free air conditions. Voltage (V) 5 Hz Sound pressure level* (db(a)) Airflow at free (m 3 /h) Insulation / IP -2 235 16 23 33 18 II / IP45,77 Weight (kg) 575

Dimensions (mm) Performance curves P Pa mmcda 9 9-2 8 7 6 5 4 3 8 7 6 5 4 3 2 1 2 1 4 8 12 16 m 3 /h Q..1.2.3.4.5 m 3 /s Accessories GSA-125 Flexible aluminium ducting GRA-15 Aluminium exterior grille CX-125/215 Worm drive ducting clip PER-125W Back draft shutter 576

AXIAL EXTRACT FANS -3 and -3 PLUS Series Range of axial extractors with airfl ow rates of approx. 3 m 3 /h, for connection to 15-16 mm diameter circular ducting. Motor mounted on silent-elastic-blocks (-3) which absorb the vibrations and allow offering very low noise level. All the fans are manufactured from injection moulded plastic, fi tted with automatic shutter and single phase 23V-5Hz, class B low consumption motor equipped with overload thermal protection. All the fans are class II insulation, IP45 rated and suitable to operate with air temperature up to 4ºC. The -3 CZ and CRZ can be supplied with an aesthetical silver front grille. Back draft shutter Silent-blocks Quiet operation To prevent air entry and limit heat leakage when the extractor is not operating. It opens due to the pressure of the air Motor mounted on Silent-elastic-block to prevent vibration and noise transmission (-3) -3 Usual extractor In usual extract fans the vibrations are transmitted to the surrounding areas while in extractor fans the vibrations are absorbed by the Silent Blocks Models features CZ CRZ CHZ CZ PLUS CRZ PLUS CZ SILVER CRZ SILVER CHZ SILVER Pilot light Backdraft shutter Adjustable Run-On-Timer (1-3min) Adjustable humidistat Ball bearings Silver colour Technical characteristics Model Speed Abs. power at Voltage (V) Sound pressure Airflow at free Insulation / IP Weight free level* (r.p.m.) (W) 5 Hz (db(a)) (m 3 /h) (kg) LENT-3 17 29 23 32 28 II / IP45 1,25-3 PLUS 2 17 23 36 32 II / IP45 1,65 * Sound pressure level measured at 3 m at free air conditions. 577

Dimensions (mm) Performance curves -3 Accessories GSA-15 Flexible aluminium ducting GRA-15 Aluminium exterior grille PER-16W Back draft shutter CX-125/215 Worm drive ducting clip REB Single phase electronic speed controllers 578