OACS Outdoor Air-Cooled Central Chillers

Similar documents
TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TTOACS SERIES. Air-Cooled GREAT FOR NEW START-UP INSTALLATIONS OR EXPANSION OF EXISTING SYSTEMS...

SERIES. OACS Series central chiller can be used on a variety of process applications that require 20 F to 70 F chilled water.

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

Precise Temperature Control; Compact Footprint

NQ Series Portable Chillers

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

GP SERIES Packaged Chillers

MEDICAL CHILLER SYSTEMS

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Central Chillers TS Series

CF-10A shown CF- 2A Shown

SENTRA Series Water Unit

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

MAC N-407 Air-Cooled Chiller

Outstanding Performance; Application Flexibility

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

Liebert CSU3000 Chiller

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

LQ AQ SQ. Air-cooled and water-cooled portable chillers

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Temptek Auxiliary Equipment

PACKAGED AIR COOLED Product Data Catalog

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

MACH N-407 Heat Pump Air-Cooled Chiller

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

30GT FLOTRONIC AIR-COOLED CHILLERS

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

30GN FLOTRONIC II AIR-COOLED CHILLERS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Ultimate energy saving technology

Call us today! (800)

Call us today! (800)

AUXILIARY EQUIPMENT FOR ALL YOUR NEEDS

Nirvana. Cycling Refrigerated Dryers

Call us today! (800)

Refrigeration Plant Information. We Speak Hockey 365

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

MAC-120HE-03 Air-Cooled Chiller

Air cooled industrial chillers

Ultimate energy saving technology

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Nirvana Cycling Refrigerated Dryers

ULTIMATE ENERGY SAVING TECHNOLOGY

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

.2 Section Waste Management and Disposal.

VariCool VAV Engineering Guide

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE. Master Rack Compressor Sequencer 7/21/2017

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

Air-Cooled Condensing Units with Compact Screw Compressors

TRIDENT GS SERIES Central Chiller

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Chillers CA Series: 35º 55º LCT CF Series: 35º 55º LCT CE Series: 35º 55º LCT CLH Series: 15º -15º LCT CLM Series: -10º -70º LCT

ACMVTECH HIGH EFFICIENCY UNITARY AHU

INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE

Water chillers water/water type SIGMA Technical information manual

500 EX Fusion Compressor Series

R- 410A Series Zero Ozone Depletion

REFRIGERATION PRODUCTS

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers

Air Cooled Chiller Product Data Catalog. Air Cooled Template

WO P NF L M 407c Spec Submittal

WO P NF L M 407c Spec Submittal

Chapter-8 Capacity Control of Refrigeration Systems

Refrigerant air dryers. FD series ( l/s, cfm)

Mission Critical Air Conditioning Systems

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

MODEL NUMBER: SRCOOL60KCW

Be sustainable while protecting your business

Hi-Pres Cooling Products Catalogue. Product Catalogue

kw COOLING kw HEATING

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

GENERAL INFORMATIONS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Aquaflair TRAC-TRAF-TRAH

Scroll Water Cooled Chiller

Installation Operation Maintenance

JCseries EVAPORATIVE CONDENSER. engineering data

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

PURESTREAM CHILL-CUBE TM BY FRIULAIR

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Water-to-Water Heat Pump Product Data Catalog R-134a Modules MR010AN, MR015AN, MR020AN, MR030AN, MR040AN, MR050AN, MR070AN, MR085AN

PRODUCT GUIDE

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

LL Series Chillers and Outdoor Mechanical Rooms. Engineering Catalog

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

Transcription:

OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977

A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single frame Outdoor installed Air-Cooled design 5-210 ton models 20-80 F fluid temperature range for models using R410A refrigerant 20-65 F fluid temperature range for models using R407C refrigerant Advantage s OACS Outdoor Air-Cooled Central Chiller line has capacities ranging from 5 to 210 tons of cooling. The standard Advantage OACS Central Chiller is configured with reservoirs and pumps housed in a single frame making it a complete self-contained package which reduces installation costs compared to other systems. In addition, the OACS systems are designed to be installed outdoors, saving valuable indoor manufacturing space for other operations. OACS Series central chillers combine 1 or 2 independent refrigeration circuits along with an integrated reservoir and pump system to make a compact yet powerful plant wide chilling system. The integrated reservoir and pump system includes a large reservoir with process pump (1 pump systems) or independent process and recirculating pump (2 pump systems) for system flexibility. Models with 2 independent refrigeration circuits allow for system redundancy and energy efficient capacity control. Systems can be configured for future expansion to meet your growing cooling needs. When an existing reservoir and pump(s) are already in place the standard integral reservoir and pump system can be eliminated. All Advantage OACS Chillers are precisely engineered and manufactured using only the finest components the industry has to offer. Delivered fully charged with non-ozone depleting refrigerant, tested and ready to run just place on a pad, connect power to the unit and fill with water and glycol. Contact Advantage and let us help you find the best central chiller package to fit your specific needs! Proudly Made In The USA MODEL DESIGNATOR FOR OACS SERIES OACS 10S MG 1P OACS Series Nominal Tons of Capacity Circuits S: Single Circuit D: Dual Circuits Number of Pumps 1P: Single Process Pump 2P: Process & Evaporator Pumps 3P: Process, Evaporator & Standby Pumps APT: Model without Integral Pumps & Tank Control Instrument MG: Single Zone MZC: Dual Zone (optional on Single Zone models)

Control Instrumentation To Fit Your Needs MZC III INSTRUMENT The MULTIZONE INSTRUMENT (MZCIII) is the standard control instrument on units with two refrigeration circuits. It is optional on single circuit units. MZCIII INSTRUMENT FEATURES: Tailor made for Advantage chillers used in critical industrial cooling applications Monitors the complete system operation and provides precise control of process fluid temperature INDUSTRY 4.0 READY Can communicate via Modbus RTU or SPI protocol Unique design distributes risk of system downtime due to control instrument problem DESIGN ELEMENTS CONSIST OF:» Operator interface DISPLAY BOARD * Intuitive design using discrete push buttons to index through circuit information and status * Dual display windows continuously show to process and setpoint temperatures * Green LED lights provide at a glance confirmation of proper system operation * Lights change to flashing red to indicate the system is out of proper operating parameters * Can control up to 6 refrigeration circuits» Individual refrigeration circuit ZONE BOARDS * Communicate information about refrigeration circuits to Display Board * During the unlikely event of a display or zone board failure, the unaffected zone boards continue to run their refrigeration circuits * Highly configurable for controlling central chillers with any combination of reciprocating, screw or scroll compressor» Independent panel mounted PUMP CONTROLS * Control and operate pumps independently of chiller control system * Include pump on/off selectors and indicating lights * Functions are not tied to a single PLC or discrete control system MG INSTRUMENT The MG INSTRUMENT is the standard control instrument used on models with a single refrigeration circuit. To Process 50 F Setpoint : 50 F Outputs MG INSTRUMENT FEATURES: Graphic LCD display with intuitive navigation Accurate control of fluid temperature Digital refrigerant pressure display Digital water pressure display INDUSTRY 4.0 READY Modbus RTU or SPI communication included Plain language error message reporting Controls hot gas bypass or digital scroll compressor for capacity control Alarm output with audible signal High water temperature shut down feature

Durably Constructed With Quality Components RUGGED REFRIGERATION CIRCUIT(S) Environmentally-friendly, non-ozone depleting refrigerant Complete system with liquid line solenoid valve, thermostatic expansion valve, capacity control system, refrigerant receiver and filter drier High/low refrigerant limits and pressure indicators Refrigerant sight glass and moisture indicator Heavy-Duty Compressor» Hermetic scroll, tandem scroll or screw compressors using rotary technology for smooth and efficient performance Brazed Plate Evaporators» Units with 60 tons or smaller refrigeration zones» Constructed of corrosion resistant stainless steel plates brazed together with copper brazing material» The compact plate spacing and alternating refrigerant and water flow through the plates makes them highly efficient Shell & Tube Evaporators» Used in most systems when refridgeration zone exceeds 60 tons» Refrigerant is circulated through copper tubes within the carbon steel shell to cool the process fluid CONDENSER Air-cooled condensers are industrial grade using copper tubing with aluminum fins with direct drive fan motors housed in a sheet metal enclosure EC variable speed drive motors on the header end and pressure staged fans provide low refrigerant pressure control when ambient conditions are as low as negative 20 F Full rated capacity is achieved at ambient temperatures up to 95 F or an optional alternate condenser can be selected for higher ambient conditions and high altitude installations For operation in extremely low ambient temperatures, flooded head pressure control is available as an option COOLANT CIRCUIT All standard OACS models include an integrated process fluid reservoir and pumping system These central chillers feature an industrial rotationally molded polyethylene Tough Tank or welded stainless steel reservoir OACS models include a dedicated process pump with a nominal rating of 2.4 gallons per minute per ton. Dual circuit OACS models (optional on single circuit OACS models) include a dedicated chiller recirculation pump that provides excellent system control and performance when process flow varies Pumps include suction and discharge valves along with a process pressure display Pump motor starters are mounted and wired in the system electrical panel ELECTRICAL Electrical components are UL Listed and housed in a UL508A enclosed electrical panel designed for industrial environments OACS models use weather resistant outdoor rated cabinets. The cabinet that houses the control instrument includes a viewing window for easy access to system information All electrical panels include branch circuit protection of components Electrical circuit has a standard SSCR rating of 5 ka WARRANTY 1st Year: Covering parts and labor (Please visit the Advantage web site and reference our Product Warranty forms W-700 & W-700E for details) Choice of reservoir construction; Rotationally molded polyethylene or welded stainless steel Oversized condensers for higher efficiency and full rated performance in higher ambient conditions Condensers utilizing all EC fan motors for higher energy efficiency Higher flow or pressure process pumps An optional standby pump is available on all models lessening the chance of downtime should the primary pump fail Remote control instrument display (MZCIII only) Modbus TCP Communication capability Drain-back prevention system for use with overhead piping systems Supply & return isolation valves Automatic low flow bypass valve External filters Chiller Options A main power disconnect 4 year extended compressor warranty

OACS Specifications Single Circuit Units Model OACS-5S OACS-7.5S OACS-10S OACS-15S OACS-20S OACS-25S OACS-30S OACS-40S OACS-50S OACS-60S OACS-75S OACS-95S OACS-105S OACS-125S Cooling Tons 5 7.5 10 15 20 25 30 40 50 60 73 94 105 125 Capacity 1 KW 17.6 26.4 35.2 52.7 70.3 87.9 105.5 140.6 175.8 211.0 256.7 330.5 358.7 432.5 Compressor 2 Type DSC SC DSC DSC SC SC SC SC TSC TSC SR SR SR SR Birefringent Type R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R407C R407C R407C R407C Control Model MG MG MG MG MG MG MG MG MG MG MZCIII MZCIII MZCIII MZCIII Unit Dimensions Height 87 87 87 87 87 91 91 91 104 104 99 99 99 99 Width 60 60 60 54 54 54 54 54 97 97 90 90 90 90 Length 75 75 75 127 127 200 200 200 126 180 240 240 300 240 Tank Material 6 PE PE PE PE PE PE PE PE PE PE SS SS SS SS Capacity (gal.) 68 68 68 68 68 100 100 100 150 300 350 350 350 900 Process Pump Horsepower 2 2 2 3 3 5 5 7.5 7.5 7.5 10 15 20 20 Process Flow Rate (gpm) 12 18 24 36 48 60 72 96 120 144 180 228 252 300 Evaporator Pump Horsepower 5 5 7.5 7.5 7.5 Full Load 230/3/60 35.8 44.2 56.2 88.4 102.4 132.4 161.2 200.2 246.4 328.2 Amperage 3, 5 460/3/60 17.9 22.1 28.1 44.2 51.2 66.2 80.6 100.1 123.2 164.1 214 242 291 321 575/3/60 14.32 17.68 22.48 35.36 40.96 52.96 64.48 80.08 98.56 131.28 161 182 219 241 Unit Weight (pounds) Shipping 4 980 1103 1230 1755 1940 2375 3300 3800 4650 5250 7350 8295 8950 9250 Operating 5 1544 1667 1794 2319 2504 3205 4130 4630 5895 7740 10850 11795 12450 18250 Dual Circuit Units Model OACS-10D OACS-15D OACS-20D OACS-25D OACS-30D OACS-40D OACS-50D OACS-60D OACS-80D OACS-100D OACS-120D OACS-150D OACS-190D OACS-210D Cooling Tons 10 15 20 25 30 40 50 60 80 100 120 146 188 204 Capacity 1 KW 35.2 52.7 70.3 87.9 105.5 140.6 175.8 211.0 281.3 351.6 421.9 513.4 661.1 717.4 Compressor 2 Type DSC SC DSC SC DSC SC SC SC TSC TSC TSC SR SR SR Birefrigent Type R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R407C R407C R407C R407C Control Model MZCIII MZCIII MZCIII MZCIII MZCIII MZCIII MZCIII MZCIII MZCIII MZCIII MZCIII MZCIII MZCIII MZCIII Unit Dimensions Height 87 87 87 101 101 101 101 101 82 82 97 99 99 99 Width 54 54 54 97 97 97 97 97 88 88 97 96 96 90 Length 127 127 127 130 130 130 130 186 246 246 304 360 408 240 Tank Material 6 PE PE PE PE PE PE PE PE PE PE PE SS SS SS Capacity (gal.) 100 100 100 200 200 200 200 400 400 400 400 900 900 900 Process Pump Horsepower 3 3 3 5 5 7.5 7.5 7.5 10 15 20 25 30 30 Process Flow Rate (gpm) 12 18 24 36 48 60 72 96 120 144 180 351 452 490 Evaporator Pump Horsepower 1.5 2 2 3 3 3 3 5 5 7.5 7.5 10 15 15 Full Load 230/3/60 66.2 85 136.6 168.6 196.6 230.4 270.4 350.4 435.6 539 650.2 Amperage 3, 5 460/3/60 36.6 46 71.8 84.3 98.3 115.2 135.2 175.2 217.8 269.5 325.1 415 470 542 575/3/60 30.68 38.2 58.84 67.44 78.64 92.16 108.16 140.16 174.24 215.6 260.08 312 353 407 Unit Weight (pounds) Shipping 4 1830 2005 2180 3175 3425 4000 4575 5400 6625 7325 8300 9300 11350 13500 Operating 5 2660 2835 3010 4835 5085 5660 7065 8720 9945 10645 11620 18300 20350 22500 1. Tons or kilowatts capacity at 12,000 BTU/hr/ton @ 50 F LWT, 95 F ambient and 115 F condensing. 2. SC = hermetic scroll. DSC = Copeland Digital Scroll TM. TSC = Tandem Scroll. SR = Screw. 3. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Amps shown are approximate for standard units. Custom configurations or options may change power requirement. Consult factory before installing. 4. Approximate unit dimensions and weight crated for shipment. Not for construction purposes. 5. Selection of certain options may change dimensions, weight and amps required. Confirm with factory before starting construction. 6. Tank Materials: PE = Non-rusting polyethylene. SS = Welded stainless steel Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability.

Proudly Made In The USA ADVANTAGE ENGINEERING, INC. 525 East Stop 18 Road Greenwood, IN 46142 Phone: 317.887.0729