IECEx Certificate of Conform ity

Similar documents
IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity


IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

IECEx Certificate of Conformity

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

slra IEC of Gonformity IECEx Cert f cate ü* t4

Certification Supplement Manual

Ex-d luminaire type dklk 23 (V-CG-S) GHG W. Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Dr. F.

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

IECEx Certificate of Conformity

srra, of Conformity IECEx Gert f cate ?-ot,b

VQ500 Series Combustible Gas Detector Elements

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Certificate of Conformity

Rosemount 702 Wireless Discrete Transmitter

805QS Pressure Switch-Transmitter

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

Safe Operation Manual. Honeywell IQ Force Gas Detector

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

DB5 Intrinsically Safe Sounder Type DB-5

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

FLASHLIGHT ANSI STANDARDS

GasAlertMicroClip X3 Specifications

FLASHLIGHT ANSI STANDARDS

H 2 S CO CH 4. Gas-Pro User & Operator Manual. Gas-Pro. Multi-gas monitor

INSTRUCTION MANUAL (ATEX / IECEx)

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

14300 MAINS SEPARATOR ALARM MANUAL

Certification Supplement Manual

IR15 Dual Gas Series Datasheet

HARMONISATION STATUS OF SELECTED ELECTRICAL AND NON-ELECTRICAL Ex STANDARDS MARCH 2018

Dräger X-am 7000 Multi-Gas Detection

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

P R O D U C T D ATA S H E E T

H 2 S CO CH 4. Gas-Pro User & Operator Manual. Gas-Pro. Multi-gas monitor

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

G-TECTA TM. Portable Gas Detection Instruments

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

IR25 Dual Gas Series Datasheet

Australian/New Zealand EXPLOSION-PROTECTED ELECTRICAL EQUIPMENT ANZ. Cerc1ficace ofconfor1221t:y. Issue No.: 6 Date oflssue:

Fixed Gas Detection System/Meridian CERTIFICATION

ALTAIR 5X Multigas Detector Product Specification

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Operating Instructions

INSTRUCTION & SERVICE MANUAL

Survey of electrical equipment installed in hazardous areas on tankers

Certification Supplement Manual

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

Our Extended Personal Electronic Dosimeter (PED) Family

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

OPTIBAR DP 7060 Supplementary Instructions

Clip SGD. Portable single Gas Detector. User manual

Tank Gauging System Special Safety Instruction

4) Intrinsic Safety Certification

Tetra 3. User Manual. Personal Multigas Monitor. M07654 January 2007 Issue 3

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Manual Power relay SR853

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Quick Start Guide , Rev DA December Rosemount Volume 1 Sensor Assembly

P R O D U C T D ATA S H E E T

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Annubar Flowmeter Series

Rosemount 644 Temperature Transmitter

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Transcription:

IECEx Certificate of Conform ity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: Date of Issue: Applicant: IECEx BAS 05.0038 issue No.: 14 Current 2014-11-04 Page 1 of 4 Crowcon Detection Instruments Ltd 172 Brook Drive Milton Park Abingdon Oxfordshire OX144SD United Kingdom Certificate history: Issue No. 14 (2"014-11:. 4) Issue No. 13 (2014-9-2) Issue No. 12 (2014-8-6) Issue No. 11 (2009-12-! 17) Issue No. 1 0 (2008-8-6) Issue No. 9 (2008-6-16) Issue No. 8 (2008-4-4) Issue No. 7 (2007-7-5) Issue No. 6 (2006-12- 20) Electrical Apparatus: Optional accessory: Gasman Flammable Gas Detector Type of Protection: Intrinsic safety, Flameproof Marking: Ex ia d IIC T4 (-20 C S Ta S +65 C) Approved for issue on behalf of the IECEx Certification Body: Position: R S Sinclair General Manager Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: SGS Baseefa Limited Rockhead Business Park Staden Lane Buxton Derbyshire SK17 9RZ United Kingdom

IECEx Certificate of Conform ity Certificate No.: Date of Issue: Manufacturer: IECEx BAS 05.0038 2014-11-04 Crowcon Detection Instruments Ltd 172 Brook Drive Milton Park Abingdon Oxfordshire OX144SD United Kingdom Issue No.: 14 Page 2 of4 Additional Manufacturing location (s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition: 6.0 I EC 60079-1 : 2007-04 Edition: 6 lee 60079-11 : 2011 Edition: 6.0 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in IECExATR: UKIBAS/04/0202 GB/BAS/ExTR14.0249/00 Gb/BAS/ExTR14.0324/00 File Reference: 04/0202 13/0719 14/0615

IECEx Certificate of Conform ity Certificate No.: Date of Issue: IECEx BAS 05.0038 2014-11-04 Issue No. : 14 Page 3 of 4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: IThe Gasman Flammable Gas Detector is designed to detect the presence of flammable gas, give a visual indication of! ;the concentration, and give audible and visual alarms if a preset level is exceeded. It comprises a rechargeable battery, a flammable gas sensor head, electronic circuits on printed circuit boards, a liquid 'crystal display, LED's and a piezo sounder, all contained in a plastic enclosure providing a degree of protection of at least IP20. iexternal contacts are provided for recharging, and for serial data communications. The flammable sensor used is either type VQ500 series by SGX Sensortech (IS) Ltd, to IECEx SIR 04.0014U, or 4P series,by City Technology to IECEx SIR 04.0013U, with a Code of Ex d IIC Gb and a maximum permitted ambient temperature of '+55 C. These sensors are certified to EN60079-0:2009 and EN60079-1 :2007. The apparatus must only be recharged or connected to serial communications when in a non-hazardous area, using a 'Crowcon desktop charger or charger I interface part number C01940 or C01941. Variation 0.1,The flammable gas sensor module is known as a flammable i-module. This variation permits the flammable i-module to be replaced by an oxygen i-module (for oxygen deficiency detection), or a toxic i-module. The permitted i-modules are listed in the User Manual provided by the manufacturer. I The apparatus is not designed for use in oxygen enriched atmospheres.! I ' I I CONDITIONS OF CERTIFICATION: NO I I I I ----- -- -- ---_._--_.. _._-----_. I I

IECEx Certificate of Conformity Certificate No.: Date of Issue: IECEx BAS 05.0038 2014-11-04 Issue No.: 14 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Variation 14.1 To permit a minor change to the GASMAN Charger/Interface terminals not affecting the original assessment. Variation 14.2 I I,To permit the addition of an alternative component certified Gas Sensor for the GASMAN Flammable: SGX Sensortech (S.A.) Micro-Pellistor MP-7217, MP-7218 andvq548mp, covered by certificates IECEx ULD 14.0002U andl DEMKO 14 ATEX 1266U to standards IEC 60079-0:2011 Ed 6 & IEC 60079-11 :2011 Ed 6 and EN 60079-0:2012 Ed 6 & ;IEC 60079-11 :2012 Ed 6 respectively. ExTR: GB/BAS/ExTR14.0324/00 File Reference: 14/0615 I ' ~~~~~~~~~~~~~------------------~~~~~~~~~--------------------~ I