Installation and Operating Instructions

Similar documents
Installation and Operating Instructions

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

version 1.2 Made by NARVI Oy Finland Aito 16 / 20 / 24 / 16 VS / 20 VS / 24 VS Installation, user and maintenance instructions

Sauna Heater. Installation and Manual

INSTALLATION AND OPERATION MANUAL FOR HUUM DROP ELECTRIC SAUNA HEATER

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

WARNING VILPRA WOOD WOOD HEATER MANUAL. Marketing: SpaDealers. Korsnäs FINLAND +358 (0)

Table of contents. Installation instructions 3 4. Connecting the electric heater to electrical network 4. Control unit 4. Temperature restrictor 4

Do not touch hot parts (chimney pipe, firebox and hatch). Carefully read through the manual for the heater.

MANUAL PX4 ENGLISH. Nimbus Combi NIMC-90N NIMC-105N NIMC-120N Super Nimbus Combi ELECTRIC SAUNA HEATER / STEAM GENERATOR

Installation & Manual. Model T-25

INTRODUCTION TO HITZER STOVES INSTALLATION AND OPERATION

MANUAL FOR USE AND INSTALATION STOVE MODELS: D11-D17

Rocket heater GAMERA

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

1. Contents Principle General information Parts list Assembly Technical drawing... 18

LIMITED LIFETIME WARRANTY

Range Hoods. General Manual. For Models: IVN900X, IVN900N, IVCC900X, IVCG900, IVSG900

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

RS Chimney Fan for Solid Fuel Applications

RS Chimney Fan for Solid Fuel Applications

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

Troubleshooting Guide

Installation of a Brunner fireplace. General Indications

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Part 1: Installation Instructions for WAGENER LEON- Multi Fuel

infrared paraffin / kerosene / diesel heater

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

Nectre Inbuilt LE. Operating Instructions. Efficient Warm Friendly. Keep instructions in a safe place for future reference.

USER S MANUAL, MAINTENANCE MANUAL INSTALLATION INSTRUCTIONS

tççç= ÜÉ~íáåÖ çéíáçåë

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

Part 1: Installation Instructions for WAGENER SPARKY (Please keep these Instructions for future Reference)

Nectre MK2 LE. Operating Instructions. Efficient Warm Friendly. Keep instructions in a safe place for future reference.

INSTALLATION AND OPERATION MANUAL

Installation and Operating Manual

Instructions for installation and use

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

Operating Manual USA & Canada.

Instructions for installation and use

Operating and installation instructions for Fire Lotus H586

Website:

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Nectre N60. Operating Instructions. Efficient Warm Friendly. Keep instructions in a safe place for future reference.

Cooker Hood User Manual

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

Installation Instructions. Rayburn 300W Wood Burning Cooker

Owner s Manual for. PennStoker

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

Instruction Manual: Le Jurassien Ref 3701

INSTRUCTION FOR ASSEMBLY. 150x200 h Traditional sauna cabin

Fireplace inserts. Model SK1000, SK2000. Installation instructions Care and firing instructions

Owner s Guide Installation & Operation

FLUE GAS TEMPERATURES OF FIREPLACES

Bergen PRPMXXXX. Smoke Control Kit Additional Installation and User Instructions for use in Smoke Control Areas

INSTRUCTION FOR ASSEMBLY. 200x200 v Traditional sauna cabin

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

INSTRUCTIONS FOR INSTALLATION AND USE OF ZINO 700,900,1100

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

Sauna Pod 4 M. health, beauty, peace of mind

Sauna Barrel 3 M. health, beauty, peace of mind

Installation instruction

VASKA C11. gas-fireplace user manual. Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0) F.

Orion NO GB PL. Brukerveiledning 2 User manual 9 Instrukcja obsługi 15

Installation instruction

SAFIRE 2000A FUEL OIL HEATER INSTALLATION, OPERATION AND MAINTENANCE

BWTD1 Fully integrated air-vented tumble dryer

Troubleshooting and Maintenance: Wood Stoves

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

user manual Model #: BLZ-WVH-42

'' Stone Fireplace Model# SRFP41301 Instructions Manual

WOOD STOVE SERVICE MANUAL

MODEL SORDO SORDO SORDO SORDO 80 Flatline

INSTRUCTION. for installation and operation of solid fuel fireplace

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

VH60SS 60CM VISOR HOOD STAINLESS STEEL

Gas Fire Patio Heater Q9

OFF. 20 min. 60 min. 30 min. 60 min OFF. 100 min Start. 200 min 150 min

Please read this booklet, for the safe installation of your MULTI FUEL FIRE

Technical certificate, instruction for installation and use. Sauna heater VIENYBĖ- P K6M ĮST :2003 ГОСТ

ULC-S610-M87 (A1998), UL

GETTING STARTED? EASY.

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Furthermore, the fire flaming in your FIREPLACE hearth creates an intimate atmosphere for your family and friends.

User Manual. Tumble Dryer ZDC8202P

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

INSTRUCTION FOR ASSEMBLY

Instructions for the Use and Care and Installation of ORC97G ORC98G. Glass Canopy Rangehoods

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

GETTING STARTED? EASY.

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

#8 Maintaining your heating system

PER-EKO type KSW & KSW PLUS Instruction Manual

104 MK II WOOD-BURNING STOVE

CANOPY RANGEHOOD. instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY

Transcription:

Installation and Operating Instructions Puu Pipe heater 04/2016

Contents 2 1 General safety instructions 3 2 Puu Pipe heater 4 Parts of the heater 4 3 Technical specifications 5 Nominal power, efficiency, emissions, average temperatures of flue gases 5 Dimensions of the heater and the quantity of stones 5 4 Sauna room 6 Ventilation of the sauna room 6 Hygiene of the sauna room 6 Protecting the floor 6 Safety distances 7 Light protection 8 5 Assembly and installation of the heater 9 Before installing 9 First heating 9 Piling of stones 10 Fuel 10 Connecting of the heater to a masonry chimney flue via the rear connection opening 11 Connecting of the heater to a masonry chimney flue via the upper connection opening 11 Change the opening direction of the door 12 6 Use of the Puu Pipe heater 12 Heating up the heater 12 Adjusting the flue draw 13 Steam water 13 Chimney flue 14 Maintenance and service 14 Maintenance, spare parts 14 Warranty 14 Replacement of heater stones 14 7 Troubleshooting 15 The flue does not draw, smoke is coming into the sauna 15 The sauna does not heat 15 Heater stones do not heat 15 The heater produces odor 15 The effect of heating on the sauna room 15 8 Service history 16

1. General safety information For safe use of sauna, please read these safety instructions first! Always check the adequacy of fire protection distances! Failure to observe the connection instructions may result in a fire risk! Always check the sauna room before heating! Do not use the sauna for a drying room for clothes or towels due to fire hazard. Be careful around the hot heater because the stones and metal parts may burn your skin. The water steam of the heater is burning hot and may cause burn injuries. Children, the disabled and the sick should be subject to surveillance when in the sauna. The benches and floors may be slippery, so move with caution in the sauna. Do not enter a hot sauna under the influence of intoxicating substances (alcohol, medicines, narcotic substances, etc.) Improperly filled stone compartment causes a fire hazard. The covering of the heater causes a fire hazard. 3 Prolonged sitting in a hot sauna will raise your body temperature, which may be dangerous. Maritime and humid climate may corrode the metal surfaces of the heater. This device is not intended for the use of children or other persons whose reduced physical, sensory or mental capabilities, or lack of experience and knowledge prevents them from using the appliance safely, unless the person responsible for their safety monitors them or has instructed them in the utilization of the device. Children should be supervised so that they would not play with this device. This device complies with the following requirements: To enable continuous product development, Mondex reserves the right to change the visual and technical characteristics of the products without prior notice.

2. Puu Pipe heater Mondex Puu Pipe heater 4 Parts of the Puu Pipe heater 1) The firebox door (door hinge is changeable) 2) Ashtray 3) Upper connection opening 3 4 5 4) Rear connection opening 5) Sweeping door 1 2

3. Technical specifications Nominal power, efficiency, emissions, average temperatures of flue gasses* Stove Puu Pipe 16 Size of sauna 8-16 m³ Nominal power 13 kw Efficiency 71 % CO- content with 13% oxygen content 0,51 % Temperature of the flue gasses 379 C Total amount of wood / fillings / heating time 9,5 kg / 3 / 90 min Table 3.1 * Mondex Puu Pipe heater is tested according to EN 15821. Test report no. VTT-S-15.2015 Dimensions of the heater and the quantity of stones Model Height (mm) Diameter (mm) Firebox cover thickness (mm) Flue Ø (mm) Amount of stones (kg) Puu Pipe 16 750 460 8 115 70 Table 3.2 460 mm 5 750 mm Ø 115 mm 113,5 mm

4. Sauna room Ventilation of the sauna room Natural ventilation The fresh supply air is just above floor level from the heater, and the air is removed as far as possible from the heater, near the ceiling. The heater circulates the air efficiently so that the task of the outlet opening is mainly the removal of moisture from the sauna after bathing. Mechanical ventilation Fresh supply air is led approx. 500 mm above the heater and is removed from near the floor, for example, from under the benches. Hygiene of the sauna room When using the sauna, we recommend using bench covers, so the sweat would not drain onto the benches.sauna benches, walls, and floor are recommended to be washed at least once every six months. For washing of the sauna should be used a scrubbing brush and a cleaning agent meant for washing the sauna. Protecting the floor A B C 6 300 mm 300 mm 400 mm 300 mm 60 mm 60 mm Concrete floor, no tiling (A) The heater can be installed directly on a concrete floor, if the concrete slab has a thickness of at least 60 mm. Make sure that the cast concrete below the heater has no electrical cables or water pipes in it. Combustible material for the floor (B) Protect the floor with at least 60 mm thick slab of concrete that extends from side to side and rear at least 300 mm away from the heater (if not limited to the wall) and in front of at least 400 mm from the heater door. Support the slab a little bit off the surface of the floor in order to keep the floor material dry. Tiled floor (C) Floor glues and plasters and waterproofing materials used under the tiles cannot withstand the thermal radiation of the heater. Protect the floor with a fireplace safety pad or with similar heat radiation protection.

500 Safety distances 50 1250 mm 50 A B C C 250 50 D Ceiling (A) The minimum safety distance from the upper surface of the heater to the ceiling is 1250 mm. Masonry walls (C) Leave a 50 mm air gap between the heater and the wall. This requires that the front and one side of the heater are open for air circulation. The space required for operation and maintenance (D). The user of the heater needs at least 1m 2 space in front of the heater 100 100 100 B 250 7 C 250 250 D 500 B D B The heater in a recessed wall If the heater is installed in a recessed wall, leave a 100 mm air gap between the heater and the walls. The space required for operation and maintenance (D). The user of the heater needs at least 1m 2 space in front of the heater. The walls and the benches of combustible materials (B) The minimum safety distances of the heater for combustible materials: on the sides and behind 250 mm, in front 500 mm. The space required for operation and maintenance (D). The user of the heater needs at least 1m 2 space in front of the heater. Model to the sides to front behind up Volume Puu Pipe 16 250 500 250 1250 8-16 m³ Table 4.3 Safety distances for a combustible material (in mm). Safety distances are measured from the outer surfaces of the product.

Light protection Safety distances to combustible materials may be reduced by half with a single and a quarter of double ignition protection. Simple light protection (1x) can be done from at least 7 mm thick non-combustible, fiber-reinforced cement board (minerit board, etc.) or at least 1 mm thick metal plate. Double light protection (2x) can be made of the two above-mentioned plates. Fastening points must be sufficiently dense so that the structure would be stable. Leave at least 30 mm air gap between the surface to be protected and the board/boards. Light protection should extend at least 600 mm above the heater. Single light protection equals at least to 55 mm in masonry. Double light protection equals at least to 110 mm in masonry. Masonry must be open at the edges and at least 30 mm away from the protected surface. The adjustable legs of the heater allow you to install the heater directly and firmly also on an inclined floor surface. The adjustment range is 0-30 mm. Leave a generous air gap between the heater and the floor. Screw the adjustable feet on downwards so much that you can rotate them, e.g., with an open-end wrench when the heater is in place. NOTE! Adjustable legs can scratch the surface of the floor if the heater is moved on the floor. 8 A B 1x A 30 600 B 2x A (min) B (min) 1x 125 250 2x 62,5 250 30 30

5. Assembly and installation of the heater Storage Until assembly the heater shall be stored in an upright position in a warm and dry location. Delivery content Heater stones are not included in the delivery. Inspect the heater visually. If you notice any discrepancies, please contact the store from where you purchased. Be careful when taking the heater out of its package to avoid dents or other mechanical damage on the heater. The sauna s floor surface should be properly protected before beginning of the installation. Before installation 1) Prior to installation make sure that the protection distance requirements are met. 2) Within the safety distances of the heater should not be electrical equipment or wiring and flammable materials. 3) Please also note the safety distances of the chimney flue! If the safety distance requirements are not met, you must use additional protection. 9 4) For more detailed instructions on the fire safety provisions, please contact the fire authorities. First heating Pre-heat the heater outdoors or in a well-ventilated area. The surface of the heater has been treated with paint, part of which burns out during the first heating. This results in the smoking of the frame. When the smoke no longer forms, the heater is ready for use. If the heater is preheated outdoors, smoke pipes should be fitted to provide the draw and also to burn the protective material from them. The surface treatment of the heater achieves the final strength during the first heating of the heater. Avoid rubbing or wiping the painted surfaces of the heater before the first heating. For the first heating, one load (about 5 kg) of wood is sufficient. Pre-heat the heater without stones. Stack the stones into the heater only when the heater has cooled down completely after the first heating. Always keep the firebox door closed during the heatings! Do not throw water on the heater during the first heating. The paint surface may become damaged. On installation of the heater, adhere to the distances in accordance with the instructions of combustible material (see page 7).

Stacking of the stones Use only stones that are meant for sauna heaters. Suitable stones are for instance olivine diabase, peridotite or olivine. To make assure sufficient air circulation the most suitable stone size on the fireplace is of 10-15 cm diameter. Between the frame and the fireplace use 5-10 cm diameter stones. Of the both sizes you will need 2 boxes. Stone collected from the nature surface are not suitable as heater stones. Rinse the heater stones from dust before stacking these to the heater. Stack bigger stones on the bottom and the smaller stones on the surface. Stack the stones loosely so that air can pass them. The stones are stacked loosely, in order to make a good air circulation. This way the heating of the sauna is also quicker! The stones should be stacked this way in layers until all stones have been placed. When stacking the stones, please do not batter on the heater s metal surfaces in order to avoid damage. Dents caused by the user are not covered by the manufacturer s warranty or other product liability. For further information about the warranty and changing of the stones please look at page 14. Fuel Since the wood moisture significantly affects the cleanliness of the combustion as well as in the efficiency of the heater, only dry wood should be used to fuel the heater. Dry logs can be identified by their clinking sound when knocking against each other. 10 For kindling is suitable, for example, bark or newspaper. Store the fuel in the fuel storage. A small amount of firewood can also be stored in the vicinity of the heater, as long as their temperature does not exceed 80 C. In the heater must not be burned: - Chipboard, plastic, coal, briquettes, pellets, or other such fuels whose calorific value is very high. - Painted or impregnated wood. - Waste (e.g., PVC plastics, textiles, leather, rubber, disposable diapers) - Garden waste (e.g., grass, tree leaves)

Connecting of the heater to a masonry chimney flue via the rear connection opening Make a hole into the firewall for the flue connection. Note the height of the possible floor protection at the height of the hole. Make the hole a little bigger than the flue connection pipe. A suitable sealing gap around the connection pipe is about 10 mm. The inner corners of the flue hole should be rounded so that the flue gasses have full access to the flue. Attach the flue connection pipe into the rear connection opening of the heater. Make sure that the connection pipe is tightly and firmly attached. If necessary, tap with a hammer. Push the heater into place. Do not push the flue connection pipe too far into the flue - the flue can become clogged. Shorten the pipe if necessary. Seal the flue connection pipe in the hole of the firewall for example with a fireproof mineral wool. Ensure the tightness of the flue connection and if necessary, add more fire-resistant mineral wool. 613 mm 11 Connecting of the heater to a masonry chimney flue via the rear connection opening The upper connection can be carried out with a straight 45 or 90 flue pipe. Move the cover plate to the rear connection opening. Attach the flue connection pipe into the upper connection opening of the heater. Make sure that the connection pipe is tightly and firmly attached. Push the heater into place. Do not push the flue connection pipe too far into the flue - the flue can become clogged. Shorten the pipe if necessary. Seal the flue connection pipe in the hole of the firewall, for example with fireproof mineral wool. Ensure the tightness of the flue connection and if necessary, add more fire-resistant mineral wool. Straight 45 90

Changing of the opening direction of the door You can install the door of the firebox to open either right or left. 1) Remove the hinge shaft 2) Raise the door from its place and turn 180 3) Place the hinge shaft into its position 1 2 3 12 6. Use of the Puu Pipe heater Heating up of the heater Before heating up the heater, make sure that that in the sauna or inside the safety distances of the heater are no foreign objects that could create a fire hazard when heated. Empty the ash drawer to allow for the efficient and clean combustion. Pile the firewood to the fire site loosely so that the combustion air can be reached between them. Place the larger wood on the bottom and the smallest on top. Use the wood with a diameter of about 8-12 cm. Fill about 2/3 of the fire site with wood. Place the kindling on top of the firewood. Lighting taking place from the top causes the least emissions. Light the kindling and close the door. The door knob and the ash tray door handle may become hot and burn the skin when heating the heater. Use the tool supplied with the heater or equivalent for handling them when the heater is hot.

Adjusting the draw The draw is adjusted by loosening the ash tray. During the early stages of heating of the heater, you may want to keep the ash tray slightly ajar to enhance combustion by a good draw. During the using of the sauna and when the sauna is already hot, the ashtray may be closed or at least reduce the gap to curb the combustion and wood consumption. During the excessive draw, the stove body starts burning up throughout until red-hot. As a result, the lifetime of the heater will be shortened significantly. If necessary, add more wood to the fire site when the embers start to fade. Use the wood with a diameter of about 10 15 cm. For maintaining the sauna temperature, a couple of logs at a time are sufficient. Prolonged intense heating can cause a fire hazard! It can be considered a rule of thumb that the temperature of more than 100 C in the sauna is too much. Adhere to the amounts of wood indicated in the heating instructions. Let the heater, the flue, and the sauna cool off if necessary. The draw control plate under the sweeping door In the heater under the sweeping door is a draw control plate which can either increase or limit the draw. Due to a high chimney or others like that, the draw can be too strong, in which case the opening is adjusted to be smaller by the draw control plate. Similarly, if a sauna is located, e.g., on a downhill slope, a better draw may be needed in which case the opening of the draw control plate is increased. After the adjustment, make sure that the draw control plate is tightened securely so that it cannot move as a result of thermal expansion. 13 Steam water For the steam water should be used clean drinking water. Make sure of the quality of the steam water, as salty water or water containing lime, iron or humus may cause corrosion of the heater - fast! The use of seawater will corrode the heater in an instant, and so neither this or any other saltwater may be used. Quality standards of the steam water Humus content < 12 mg/l Calsium content < 100 mg/l Iron content < 0,2 mg/l Manganese content < 0,05 mg/l

Chimney flue The heater can be safely installed in a T600 temperature rated chimney flue, unless other instructions have been given. The inside diameter of the chimney flue pipe must be 115 mm. The draw of the chimney flue is recommended to be approx. -12 Pa. The heater can be connected to a chimney flue either from behind or on top of the heater. An un - necessary opening in the heater is closed with the supplied closing cap. The heater also comes with a short connecting flue pipe with which the heater can be connected in the rear to the flue pipe. The connecting flue pipe cannot be installed too deeply into the chimney flue because it prevents the draw. Also, leaks in the flue weaken the draw of the heater, and, therefore, the flue connection must always be sealed with a fire-proof sealing material. If the flue connection is leaking, the risk may be that the combustion gasses produced by the heater ignite in the chimney. The chimney flue and the connection pipes must regularly be swept, according to the instructions of the law. Maintenance and service Drain the ash tray of the heater always before each new heating, so that the combustion air directed through the ash tray would cool the grate and lengthen the service life of the grate. For the ashes, use a container made of metal, preferably with feet. The ash container must not be stored in the vicinity of flammable materials, as among the removed ash may be glowing embers causing a risk of fire. The soot and ash accumulated in the smoke ducts of the heater must be removed periodically through the sweeping hole in the middle smoke ducts. 14 Due to the strong thermal fluctuations, heater stones erode and crumble during operation. Pile the stones again at least once a year, more frequently under heavy use. At the same time, replace the disintegrated stones with new ones. When changing the sauna stones, remove the stone debris accumulated in the stone compartment. Wipe the dust and dirt off the heater with a damp cloth. Maintenance, spare parts If in the heater is an apparent unexplained fault, please contact the technical support department of the manufacturer. Spare parts are readily available from Mondex vendors and manufacturers. On purchase of spare parts, it is necessary to make a note of the name and power of the heater so that the correct spare parts can be supplied. Warranty For heaters and control units in private use, the manufacture, grants a warranty of one (1) year from date of purchase when the assembly, usage and service has been done according to instructions. The firebox door might change color when heating the heater, which is normal for stainless steel. The warranty does not cover this color change. Keep the sales receipt or warranty card. The warranty does not cover external or internal mechanical damage caused by, for example, impacts with a stone or the heater falling over. Changing the sauna stones It is important to keep an eye on the stove and the condition of the stones at regular intervals. The top layer of the stones may seem in good condition, but further down the stones are exposed to much higher stress and temperatures. Crumbled stones block the flow of air through the heater which shortens the lifetime of the heating elements. Annually change the position of the stones and replace any broken pieces (in commercial use every 6 month). Warranty does not cover heating elements that brake before their normal lifetime due to above caused blocked airflow.

7. Troubleshooting The flue does not draw, smoke is coming into the sauna - The flue connection leaks > Seal the connection. - Cold brick chimney. - Underpressure in the apartment caused by a cooker hood, another furnace or other equipment > Ensure the supply of replacement air. - Ashtray is full. - The smoke ducts of the heater are blocked. - The flue connection pipe is too far into the flue. - The hole in the draw control plate is too small > Increase the hole The sauna does not heat up - The sauna is too large for the heating capacity of the heater. - The sauna has a lot of uninsulated wall surface. - The wood used as fuel is wet or low quality. - The draw of the flue pipe is poor - The smoke ducts of the heater are blocked. Heater stones do not heat up - The sauna is too small for the heating capacity of the heater. - The draw of the flue pipe is poor - The wood used as fuel is wet or low quality. - The smoke ducts of the heater are blocked. - Check the placement of the stones. Remove stone debris accumulated in the stone compartment and the too small stones (diameter less than 10 cm) from the top of the firebox. Change the disintegrated stones for larger, intact heater stones. 15 The heater produces odor - The hot heater may emphasize the odors mixed in the air, but which are not originating from the sauna or the heater. Examples: Paints, glues, heating oils, spices. The effect of the heating of the heater on the sauna room - Darkening of the wood surfaces due to the ashes dripping from the heater, the stone chippings and metal flakes is normal. For this reason, we recommend the use of dark floor coverings and seam materials. - Darkening can be added by direct sunlight, the heat radiated to the heater wall surfaces, protective materials meant for wall surfaces (poorly heat-resistant), fine stone aggregates crumbling from the stone and the smoke, which enters the sauna for example when adding the firewood. - When installing the heater follows the installation instructions provided by the manufacturer, the heater does not heat the combustible materials of the sauna room dangerously hot.

The heater s service history We recommend replacing the heater stones once a year. Date Action Mondex Oy 15 EN 15821:2010 Multi-firing sauna stoves fired by natural wood logs for space heating in residential buildings Mondex Wood Pipe Fire safety: (ignition, fire risk) - including the declared safety distance to combustible materials: Combustion emissions to the back to the side to the ceiling Approved 250 mm 250 mm 1250 mm Approved The heater s manufacturer: Surface temperature Release of hazardous substances Approved NPD Clean-ability Approved Flue gas temperature 379 C Mechanical strength Approved Premec Oy Kettukallionkatu 4 84100 Ylivieska Finland info@mondex.fi www.mondex.fi Rated power and efficiency, stated - carbon monoxide emissions with 13 % oxygen concentration (O 2 ) - overall efficiency - the flue duct draws 12 Pa - rated power 13 kw - fuel increases 4.0 kg + 3.0 kg + 2.5 kg = 9.5 kg Durability Approved (0.51 %) Approved (71 %) Approved VTT-S-01932-15