AxxonSoft. Operation Manual TROMBONE. Fire and Security Alarm Integration Module. Version 1.1. Moscow

Similar documents
Configuration and Operation Manual for the Unipos

Paradox Integration Module Settings Guide

Interfacing with the ADAM Module

Bosch TCU Integration Module Administrator's Guide

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Network Hardware and wiring (quiz)...

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Home center 2.7 Windows client Installation guide

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Ademco Vista Alarm Panel

Follett Performance Plus

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Weekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

USER S GUIDE. AXIS Cross Line Detection

MultiSite Manager. Setup Guide

IP-based Building Management Control

Installing ProSeries 2005

The Nucleus of Quality Air Monitoring Programs. Global Air Sampler Data Acquisition Software Program GASdaq

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

System Galaxy Quick Guide

This technical update applies to Pro-Watch Software Release 3.5 and later.

Laptop / PC Programming Manual

TV2 Room Pressure Monitor Quick Start Guide

Fire Operator Workstation (Fire OWS) User s Guide

Patriot Systems Limited

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3

INSTALLATION INSTRUCTIONS

Weekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture

IndigoVision. GAI-Tronics Integration Module. Administrator's Guide

Added password for IP setup page : Password must be in IP format!

Ion Gateway Cellular Gateway and Wireless Sensors

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

wireless. web-based. worthy of the name RACO.

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

Simplex Panel Interface Guide

Section 5. Control Systems

LineGuard 2300 Program User Manual (FloBoss 107)

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

CompleteView SightLogix Sensor Setup Manual. CompleteView Version 4.7.1

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Honeywell Total Connect Remote Services

GLOBAL. InstallatIon & operation manual

Galaxy. Galaxy Robot Sampler Page 1

Model 4880 Status Output Display Module Manual

FieldServer Driver - Serial FS Notifier NCA

Using the Dome Leak Sensor with SmartThings. Table of Contents

SIMATIC IPC DiagBase SIMATIC. Industrial PC SIMATIC IPC DiagBase. Introduction. DIAG software components. Quick-Start Guide

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

ONYXWORKS AND FIRSTVISION. Version 4

"VOICE OF SECURITY: Trends In Intercom, Public Address, and Mass Notification Emergency Communications

Installing ProSeries 2004

SIMATIC IPC DiagBase SIMATIC. Industrial PC. Introduction. DIAG software components. Quick-Start Guide. Hardware and software requirements

Raytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

RFT CARES Android App User Guide

Section 9 System Operation

Avigilon Control Center System Integration Guide

«Smart Home Technology» by Quadrobit: security energy comfort

TORO SENTINEL APPLICATION NOTE AN04: ACTIVITY / ALARM MONITOR

IP & SMS Alarm Communicator

Integration with Mobotix Q24

TV2 Clean Room Monitor

Contact ID as of 2/2/2015

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

QA16 Addressable System

Section 8 System Operation

IntesisBox BACnet/IP Server - Notifier ID3000 series

Total Solution Sirius Cooling Control Unit (CCU) Sirius CONFIGURATION TOOL. (Windows -based configuration application.)

ThermoControl 0 C - 10 C - 20 C - 30 C

Avigilon Control Center System Integration Guide

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Ethernet General Purpose

Exercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

PHD Dolphin Installation

Table of Contents. i-vu CCN Standard 4.2

1.1 Remote Annunciator Controller (RAC) using the one ATC-300+ connected via RS-485 network.

Situational Awareness for Life & Fire Safety. October 10, 2013

Moxa Proactive Monitoring User s Manual

Avigilon Control Center System Integration Guide

Program version Alarm Control Panels PROGRAMMING GDAŃSK. versa_p_en 03/09

Avigilon Control Center 5 System Integration Guide

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

SETTING UP DSC INTEGRATION THROUGH ENTRAPASS

CSP-204 CSP-208 CSP-104 CSP-108

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

User Manual. Dryer Controller M720

Architectural and Engineering Specification for a Security Management System. StarNet 2

SIMATIC. Industrial PC SIMATIC IPC DiagBase V Introduction. SIMATIC IPC DiagBase software components. Quick-Start Guide

Integration Test Plan

OVEN INDUSTRIES, INC.

Cow Monitoring Solutions

TECHNOLOGY TECHNOLOGY

Galaxy Pulsar Plus Digital Battery Plant Controller

Transcription:

AxxonSoft Operation Manual TROMBONE Fire and Security Alarm Integration Module Version 1.1 Moscow 2012 1

Contents 1 LIST OF TERMS... 3 2 INTRODUCTORY NOTES... 4 2.1 Purpose of the Manual... 4 2.2 Purpose of Axxon Soft Intellect Fire and Security Alarm Subsystem... 4 2.3 Trombone Integration Module Overview... 4 3 SETTING UP TROMBONE INTEGRATION MODULE... 5 3.1 Setup... 5 3.2 Setting Up Connection... 5 3.3 Reading Trombone-CP8 Device Configuration... 6 4 TROMBONE INTEGRATION MODULE OPERATION... 8 4.1 Trombone Integration Module Basics... 8 4.2 Handling Trombone-CP8 Device... 8 4.3 Alarm Input Control... 8 4.4 Sound Output Control... 9 2

1 List of terms Server a preconfigured PC running Axxon software. Sound input a terminal intended for the input of audio notification signal. Power relay a 220V AC output terminal controlled by Trombone BP reserve power supply unit. The audio amplifiers are powered up if Trombone CP-8 switches to: Alarm, Emergency Startup, Emergency Services and Audio Notification. Zone a marked area on the site map. Sound output a terminal outputting 250 mv rated signal for further audio amplification. Light output a terminal to connect visual notification signaling devices. Alarm in a binary alarm input terminal. 3

2 Introductory Notes 2.1 Purpose of the Manual The Trombone Fire and Security Alarm Integration Module Setup and Operation Manual provides comprehensive setup and operational guidance for Trombone module operators. The module itself is a part of the Axxon Soft fire and security alarm sybsystem. The Manual includes: 1. Trombone module overview; 2. Setup guide; 3. Operation guide. 2.2 Purpose of Axxon Soft Intellect Fire and Security Alarm Subsystem The Axxon Soft Intellect fire and security alarm subsystem has been designed for: 1. Processing data collected from fire/alarm panels, sensing devices and other annunciators. 2. Automated control of executive devices, such as audio and visual notifiers (sounders and LEDs), gate bars and turnstiles, etc. Fire and security alarm subsystem consists of hard- and software components. In larger subsystems, a third party alarm subsystem operates as a hardware component integrated into Axxon Soft system. The software component consists of Integration Modules responsible for successful interaction between the security system and hardware. 2.3 Trombone Integration Module Overview Being a part of fire and security alarm subsystem, the Trombone Integration Module has been designed to manage alarms. Note: Details on Trombone Fire and Security Alarm system (FSA) can be found in its manuals (manufacturer: OOO OPTECH, Russia) Before setting up the Trombone Integration Module, you need to do the following: 1. Install all the needed equipment; 2. Configure all hardware components according to their reference manuals; 3. Connect the Trombone FSA to the system server PC. 4

3 Setting up Trombone Integration Module 3.1 Setup 1. Set up the connection between the system and the Trombone Fire and Security Alarm system (Trombone FSA). 2. Read the configuration parameters from the Trombone-CP8 device. 3.2 Setting Up Connection Axxon Soft system provides Trombone FSA connection setup by means of a dedicated settings panel for a SGPS Trombone object. This object is created on the basis of the parent Computer object (the Hardware tab in the System settings window) (See Fig. 3.2 1). Fig. 3.2 1 Creating a SGPS Trombone object To set up the connection, you should do the following:: 1. In the SGPS Trombone object settings window, use the up/down arrows to specify a COM port used for linking the subsystem to the server (See Fig. 3.2 2). Fig. 3.2 2 Setting up the connection 2. Using the SGPS Trombone as a parent, create a child object Trombone CP-8. Click the newly created object's name to open its settings panel (See Fig. 3.2 3). 5

Fig. 3.2 3 Trombone CP-8 object settings panel 3. Enter the address of Trombone-CP8 device (See Fig. 3.2 3). 4. Click Apply. After connection setup is completed, several child objects will be automatically created under the Trombone-CP8 object, each reflecting an actual executive device within Trombone FSA. Any manually created extra objects will be ignored by the system (See Fig. 3.2 4). Note: If you occasionally remove an actual child object, you will have to add it back manually, otherwise its physical counterpart (a hardware component) will be ignored by the system. Fig. 3.2 4 A set of child objects automatically created within Trombone-CP8 parent object Now, the connection setup is finished. 3.3 Reading Trombone-CP8 Device Configuration To download the Trombone-CP8 device configuration parameters set, you should: 1. Click the newly created object's name to open its settings panel (See Fig. 3.3 1). 6

2. Click Read Info (See Fig. 3.3 1, 1). Fig. 3.3 1 Reading Trombone-CP8 device configuration After downloading the parameter set from the device, the Name and Version fields will be updated (See Fig. 3.3 1, 2 and Fig. 3.3 1, 3). You have successfully read Trombone-CP8 device configuration. 7

4 Trombone Integration Module Operation 4.1 Trombone Integration Module Basics The following UI objects are used to operate the Integration Module: 1. Map; 2. Events journal. Detailed instructions on setting up the Map and Events Journal UI objects can be found in the Axxon Soft Intellect Software Package documentation: Administrator Manual. Also please refer to the Axxon Soft Intellect Software Package documentation: Operator Manual for detailed instructions on how to handle these and other system objects. 4.2 Handling Trombone-CP8 Device You can handle the Trombone-CP8 device via the Map interactive window and the Trombone-CP8 object menu (See Fig. 4.2 1 and Tab. 4.2 1). Fig. 4.2 1 Trombone-CP object menu commands and corresponding functions Tab. 4.2 1 Trombone-CP object menu commands and corresponding functions Menu c om mand Device reset Emergency signals transfer Disable emergency signals transfer Emergency start mode Arming the device Fu n ct io n Engaging emergency services communication mode. If this Brigade Called more is activated, emergency responders are automatically notified by the fire alarm system. Disabling emergency services communication mode. If this Brigade Called more is nota ctivated, emergency responders are not automatically notified by the fire alarm system Activating emergency start mode 4.3 Alarm Input Control The alarm input is handled via the Map interactive window and the Alarm input object functional menu (See Fig. 4.3 1). If you click Enable Alarm mode, the corresponding zone switches to the Alarm mode. Fig. 4.3 1 Alarm input object menu 8

4.4 Sound Output Control The sound output is handled via the Map interactive window using the Sound output object functional menu (See Fig. 4.4 1 and Tab. 4.4 1). Fig. 4.4 1 Sound output object menu commands and corresponding functions Tab. 4.4 1 Sound output object menu commands and corresponding functions Menu command Enable Sound notification mode Disable Sound notification mode Function Enabling audible notification for the given zone Disabling audible notification for the given zone 9