SECURIT 700L PLUS ENGINEERING MANUAL

Similar documents
INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

SECURIT 703 USER MANUAL

SECURIT 700L USER MANUAL

Securit 7 Alarm Panel

USER MANUAL CEF AP28 CONTROL PANEL

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

Racal-Guardall. Countess. User Instructions. Countess

Installation Manual Premier 412/816/832. Issue 10

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

Advantage 6 Alarm Panel

IDS816 User Manual H Issued January 2009

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

USER GUIDE HARDWIRED CONTROL PANELS

THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

USER GUIDE. Security Control Panels INS046-7

THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels 1 INS167

Contents. Glossary

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Contents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

Intruder - Fire - Water Combined Alarm

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

LS800S Intruder Alarm System. Engineering Manual

Installation Manual RINS1211-4

HARDWIRED CONTROL PANELS

GARDTEC 580. Installation Instructions

L900 series USER MANUAL

TS700. Intruder Alarm Control Panel OPEN ENT 0 ESC

Scantronic Leading the way in security

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

5 Sounds and Indications

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Intruder alarm system Operating Instructions

2200 and 2200L ALARM CONTROL SYSTEMS

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Watchguard WGAP864 User Manual

Master User Guide Premier Elite Series

Gen4 Domestic Intruder Panels RELIABLE AND FLEXIBLE INTRUDER PANELS. Domestic applications

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

HILLS Series LED Code Pad User Manual

TABLE OF CONTENTS TABLE OF CONTENTS 1

PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England

16 and 16 plus User s Guide

Installation & Programming Guide

HARDWIRED CONTROL PANELS

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

M800, M800iD Plus, M1000 and M3000. User's Guide

Installation, Operating and Maintenance Manual

Intruder alarm system Operating Instructions

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Control/Communicator Installation Manual

User Operation Manual

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

Contents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2

TS700. Intruder Alarm Control Panel ENT 0 ESC

CPA6. Installation & User Guide. Intelligent Security & Fire Ltd. Compatible Equipment

NETWORX TM. User manual NX-4

Digiplex LED Keypads User s Manual

5000 SERIES 8 ZONE INSTRUCTION MANUAL

Version 1.03 January-2002 USER S MANUAL

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

PARAGON PLUS USER INSTRUCTIONS USER INSTRUCTIONS J?>5 J?>5 J?>5 J?>5 J?>5 J?>5 B??=

Microprocessor Intruder Alarm System User Guide

EC-P Zone Intruder Alarm System

ADE Gen4. Speech Dialler Engineering Information. Description. Features

INSTALLATION MANUAL PC56O. Version 1.OA

NetworX NX-8V2. LED Keypad User Manual

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

IDM4 CARAVAN ALARM. Operating instructions

USER GUIDE HARDWIRED CONTROL PANELS

System 800 Addressable Fire Detection & Alarm System

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Manager Guide. Indications on the system. Using System. Indications

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

AXI LED USER MANUAL (REV. 1.0)

Fire Command Keypad. XR5 User s Guide

USER GUIDE HARDWIRED CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

FM4000 ALARM SYSTEM TRAINING MANUAL. FM Electronics Ltd FIRE PANIC ZONES FULL SET PART SET OFF TAMPER SIGNALLING LOW BATTERY ALARM MAINS ON

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System


SPECTRA 1727 USER S GUIDE

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Transcription:

SECURIT 700L PLUS ENGINEERING MANUAL C & K Systems Ltd 13/03/97 C031-096-02 NEW ENHANCED FEATURE SET

Securit 700L PLUS Engineering instructions INTRODUCTION The Securit 700L is a microprocessor intruder alarm panel. It features seven zones of which six are programmable plus a dedicated tamper zone. A non volatile memory holds the programming options. These will be retained in total power failure. Its designed to be simple to program and allow flexibility in use. SPECIAL FEATURES Zone 7 programmable as Alarm, Fire or PA Adjustable entry/exit warning sound level Omit user disable option Omit user part set disable option Show panel status using remote LED Optional remote signalling Trigger Engineer output test facility SYSTEM PLANNING When the panel reaches you it will be factory programmed. This is done for testing purposes but can also be used for installation if required. This present program is referred to as 'factory defaults'. It is advised that the engineer should be familiar with all the features & options before attempting to program. The Securit 700L should ideally be installed out of sight but remain accessible. It should be mounted within the area covered by the alarm system. Up to 3 remote keypads can be used on the system. The positioning of these should be agreed with the user once the entry/exit routes and the Night set functions have been explained. USER/CUSTOMER CODE DEFAULTS If at any stage you want to restore the default user/customer codes, place the small link supplied with the spare fuse, on the memory default link (positioned below the microprocessor in the centre of the PCB) then remove the mains and battery supply. When the supply is restored, the panel will sound the accept tone and the factory user/customer code defaults will be restored. Remove the link. NOTE... The programming defaults will not be affected, see engineer mode 9-9. 1

FACTORY DEFAULTS User/customer Code 1 1234 User/customer Code 2 Disabled (0000) Engineer Code 7890 Circuit 1 Entry Circuit. (Fixed) Circuit 2 Alarm Circuit isolated in Night set. Circuit 3 Alarm Circuit. Circuit 4 Alarm Circuit. Circuit 5 Alarm Circuit. Circuit 6 Alarm Circuit. Circuit 7 P.A. Circuit. Full Set Exit Time 30 Seconds Night set Exit Time 15 Seconds Entry time 30 Seconds Bell Ring Time 15 Minutes Chimes Disabled SPECIFICATION A B Power Supply Mains Supply Voltage PSU output voltage Maximum output current Aux. current Battery Fuse Panel Quiescent Keypads Supply Voltage Quiescent Current Active Maximum Cable Run 100 M etres 230 V AC Nom 13.6 V Nom 1 A (total) 500 ma Max. 1 A (20 mm) 40 ma 12 V 20 ma 45 ma C (D) General Operating temperature -15 C to 50 C Humidity Up to 80% non condensing Dimensions 263 mm (W) 223 mm (H) 82 mm Control Panel Weight Stand by Battery 2.7 kg Excluding Battery 2.6 Ah 12 V Rechargeable 6 Ah max. Mounting a b c Remove the lid screws and remove lid. Remove the PCB and keypad packaging, check the contents... Unplug the AC mains supply. 2

d e Place the panel in the selected position and mark the three fixing holes. Mount the Panel securely using all three positions. WIRING THE CONTROL PANEL 1 Mains connection The mains supply should be connected via one of the separated cable entries provided. Connections should be made to the 3 way terminal block located in bottom left of panel and wired in accordance with the relevant IEE regulations via a fused spur. The panel must be earthed. IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN. 2 Battery connection. The Securit 700L requires a standby battery to be fitted to provide power in the event of the mains failure. A sealed lead acid battery should be fitted. Batteries up to 6 Ah may be used. 3 Detector circuits Connections are provided for up to seven detector circuits of which normally closed detection devices should be used. A common tamper loop is provided for all detection devices marked as 24 HR Tamper. One or more devices may be connected to each alarm circuit. These should be connected in series. These circuit connections are located to the bottom right of the PCB (see diagram B). 4 PIR Latch Line (L+) In the event of two or more PIR detectors being fitted to any single zone, latching detectors should be used. The 'L+' connection provides this function. It is low (0 V) when unset and high (12 V) when set. It should be connected to the appropriate SET or LATCH terminal in the detector. 5 AC power connector Make sure after Mounting the panel and replacing the PCB that you connect the white plug with the 3 wires to the 3 pins located in the top left hand corner of the PCB. This will ensure AC power gets from the transformer to the PCB. 6 Detector reset (ID) Some detectors require the removal of power to reset (e.g. Viper Plus or Smoke detectors). The 'ID' output should be used as the negative supply for these devices. The positive supply should be taken from the AUX +. This output can be programmed to signal mains fail by selecting option 7-5. When selected it will signal 10 minutes after the removal of the mains power and restore one minute after the mains power returns. 3

7 Internal sounders (AC driven 16 ohm Speakers) ** DIAGRAM A ** The control panel is not fitted with a speaker in the box. It is recommended that an extension speaker is fitted as it will greatly improve not only volume but also the range of sounds you will get from the control panel. If internal speakers are required they should be connected to the terminals marked EXT. SPK. A maximum of two 16 ohm speakers may be fitted in parallel. (see diagram A) 8 External Sounder & Strobe. Connection for external sounder and strobe are shown in diagram B. Please note bell trigger shown is with output for applied negative. (Negative bell ring). i ST- Strobe switched negative. ii S - Bell switched negative trigger iii + Bell hold off/strobe positive supply. iv - Bell hold off negative supply & bell tamper v -R Bell tamper return. 9 AUX DC - Detector power. The auxiliary power is provided from connections marked 'AUX'. This is to provide the 12 V supply for detectors e.g. PIR's. The auxiliary power output is rated 500 ma max. (12 V nominal). 4

** DIAGRAM B ** MOUNTING THE REMOTE KEYPAD a the b c Having agreed the position of any remote keypads to be fitted, mark holes for the mounting position. Screw the backbox in the agreed position making sure it is not twisted Note the rear entry of cabling WIRING THE REMOTE KEYPAD a The remote keypads require 6 core cable for their connection to the main control panel. b Connect the cable as shown below in diagram C Making sure each wire goes to a like named terminal in the panel. C goes to C, D goes to D, + goes to + and - goes to -. The tamper wires are wired in series with your existing tamper loop. c Individual keypads do not need to be identified to the system. ** DIAGRAM C ** 5

INITIAL POWER UP NOTE The lid should be kept off the main control panel. The keypad tamper may also be used to enter engineer mode. i ii Switch the mains supply on, the internal sounder will start. Enter 1 2 3 4 followed by # button - this will silence sounder - The TAMPER LED will then flash on the remote keypad. IF NO PROGRAMMING IS REQUIRED, REPLACE THE LID. REFER TO USER HANDBOOK FOR USER OPERATING INSTRUCTIONS. iii out To enter programming mode enter 7 8 9 0 - The TAMPER LED will go The MAINS LED will flash. To EXIT engineering, confirm any options you have selected with the * (STAR) key. Then either close ALL tamper circuits and wait for approximately 60 seconds whereby the panel will jump out of engineering mode automatically. Pressing # (HASH) key will manually exit engineering. To re-enter engineering, with ALL tampers closed, enter your engineering code and then press the # (HASH) key. This will now force the panel into engineering and if left unattended for approximately 60 seconds it will revert back to day mode. If for any reason you need to stay in engineering for longer unattended periods, once in engineering mode open a tamper circuit. The easiest way to do this is to remove the lid of the panel or keypad. EXIT TIME 3 0 range 10-90 Seconds. Enter 3-0. This has been preset for factory default - at 30 seconds. A new time may be programmed by entering one key from the following table. Once program is set press * to confirm. The accept tone will sound. Enter 1 Enter 2 Enter 3 Enter 4 Enter 5 Enter 6 10 Seconds. Led 1 on. 15 Seconds. Led 2 on. 30 Seconds. Led 3 on. 45 Seconds. Led 4 on. 60 Seconds. Led 5 on. 90 Seconds. Led 6 on. 6

ENTRY TIME 3-1 range 10-90 seconds. Enter 3-1. Again this has been preset for factory default at 30 seconds. To reprogram the entry time follow exactly the same directions as for the EXIT. Again press * to confirm option. The accept tone will sound. Enter 1 Enter 2 Enter 3 Enter 4 Enter 5 Enter 6 10 Seconds. Led 1 on. 15 Seconds. Led 2 on. 30 Seconds. Led 3 on. 45 Seconds. Led 4 on. 60 Seconds. Led 5 on. 90 Seconds. Led 6 on. BELL DURATION (Bell ring time) 3-2 range 3-20 minutes Enter 3-2. This has been preset for factory default at 15 minutes. A new time may be programmed by entering one key from the following table. Once program is set. Press * to confirm. The accept tone will sound. Enter 1 3 minutes. Led 1 on. Enter 2 4 minutes. Led 2 on. Enter 3 5 minutes. Led 3 on. Enter 4 10 minutes. Led 4 on. Enter 5 15 minutes. Led 5 on. Enter 6 20 minutes. Led 6 on. NIGHT SET EXIT TIME 3-3 RANGE 0-90 seconds. Enter 3-3. This has been preset for factory default 15 seconds. A new time may be programmed by entering one key from the following table. Once program is set. Press * to confirm. The accept tone will sound. Enter 0 0 Seconds. All LED's off ( Instant set in Night set ). Enter 1 10 Seconds. Led 1 on. Enter 2 15 Seconds. Led 2 on. Enter 3 30 Seconds. Led 3 on. Enter 4 45 Seconds. Led 4 on. Enter 5 60 Seconds. Led 5 on. Enter 6 90 Seconds. Led 6 on. NOTE: If extension speakers are fitted then the exit sounder volume can be altered in Night set only by the control marked NIGHT SET VOLUME. The level can be reduced to almost zero. When the control sets an accept tone will sound. 7

CIRCUIT PROGRAMMING Circuits 2-6 can be reprogrammed to suit your requirements. Circuit 1 is fixed as a Final exit circuit. Circuit 7 can be used to set SOME options. The method of programming is as follows: ENTER PROGRAM ZONE 4-2 2 4-3 3 4-4 4 4-5 5 4-6 6 4-7 7 Select the circuit you wish to alter. That circuit may then be programmed by entering one key from the following table. Once program is set press * to confirm. The accept tone will sound. OPTION NUMBER IF USED ON ZONE 2-6 IF USED ON ZONE 7 1 Alarm Alarm 2 Alarm with walk through Fire 3 Alarm & Isolate in Night Set PA 4 Alarm, Walk through & Isolate in N/S 5 Alarm, Walk through & N/S Entry 6 Fire 7 Entry Route SEE GLOSSARY OF TERMS FOR DESCRIPTIONS OF ZONE TYPES etc. EXTENDED PROGRAMMING OPTIONS These options are available to compliment your existing set-up. They control various aspects of the usage and control of the panel. Enter 7-1 Night set external bell disable. Enter 7-2 Chime Enable ( See user manual for zone allocation). Enter 7-3 Full set door sense setting. Enter 7-4 Output mains fail to ID- Enter 7-5 Allow Manual Isolation of Zone 1 (Entry/Exit) In night set. Enter 7-6 Remote Keypad PA Enable ( Operated by * & # ) Enter 7-7 L+ signals first to alarm Enter 7-8 Pass all low priority sounds through volume control. Enter 8-1 Customer MANUAL isolate inhibit. Enter 8-2 Customer Night set Inhibit. Enter 8-3 Output Panel Status to ID- Enter 8-4 L+ polarity invert. Enter 8-5 Strobe test Inhibit Press * to confirm. The accept tone will sound 8

Please note that option 7-5 ALLOWS the user to manually isolate zone 1 in part set. It does not AUTOMATICALLY isolate zone 1 in part set. ENGINEER ACCESS CODE The engineer access code is programmed to 7890 as a factory default. To change this code: i Enter 7 8 9 0 and remove the panel lid or keypad cover. The internal sounder will stop when the case tamper is opened - the MAINS LED will flash. ii Enter 1-1 - LEDs 1, 2, 3 and 4 will light up. Enter the new 4 digit code. After each keypress one LED will go out. The speaker will emit an accept tone if the new code is acc epted. If the speaker emits an error tone and all LEDs are extinguished the old access code is still valid. Repeat the procedure using a different code. ENGINEER EVENT LOG REVIEW The engineer log is organised into SET and UNSET events. The log will show the first to alarm and subsequent alarms as well as isolated circuits. First to alarm is shown by the LED being 'on' continuously. Subsequent alarms are shown by the LED(s) flashing and isolated circuits are shown by LED(s) pulsing slowly. The buzzer will sound whilst reviewing the 'SET' logs and will be silent whilst reviewing the 'UNSET' logs. To view the engineer logs proceed as follows: From the program mode press the '5' key. The log routine will start with DAY 1 SET. The remaining logs are viewed by pressing the relevant key '2' for 2nd, '3' for 3rd etc. on to log 9. Pressing the '0' key gives the last alarm condition. The # key will alternate between 'SET' and 'UNSET' logs and can be used at any time. To exit logs press the * key. 9

ENGINEER TEST OPTIONS The engineer has available to him some test facilities so he can test bells etc. without having to come out of engineering. These new options are accessed by pressing 6 from the engineering mode and then selecting another option below. Enter 2 Internal buzzer ( entry exit sound etc. ) Enter 3 Internal Sounder ( Alarm sounds from speaker / keypad ) Enter 4 External Bell Enter 5 External Strobe Enter 6 L+ ( Latch Terminal for Latching Detectors ) Enter 7 ID- ( Impact Detector Reset ) Enter 9 FULL LOAD ( Everything on ) Press * to finish FACTORY PROGRAMMING DEFAULTS 9-9 Factory defaults have been split into two sections, programming and codes. To return to factory programming defaults enter 9-9 the sounder will give a rapid pipping sound (the entry hurry up warning). Then enter the engineer code. If entered correctly an accept tone will sound and the factory programming defaults will be restored. If any error is made an error tone will sound and the programming will not be altered. The user and engineer codes are not changed. If at any stage you want to return the panel to factory default user/customer codes, place the small link supplied with the spare fuses, on the memory link (positioned below the microprocessor in the centre of the PCB) then remove the mains and battery supply. When the supply is restored, the speaker will omit the accept tone and the factory user code defaults will be restored. Remove the link. 10

GLOSSARY OF TERMS FULL SET This is a setting method normally related with leaving the premises. NIGHT SET This is a setting method normally used when going to bed ALARM This is a zone that will trigger the panel when it triggered WALK THROUGH This zone will trigger the panel if seen however it will ignore any activation if an entry route has been previously triggered. ISOLATE IN NIGHT SET This simply means the zone will be disabled when the panel is NIGHT SET. NIGHT SET ENTRY This means when the panel is NIGHT SET the zone, when triggered, will start the entry timer and the panel must be disarmed. If the panel is FULL SET then this zone will simply act as an ALARM zone ENTRY CIRCUIT This will start the entry timer when set. FIRE This is a zone that when triggered will emit an ascending sound from the extension speakers. If the panel is set, external sirens and strobes Will also sound but in an unset state only internal sounders will ring. TAMPER This is a loop that should run through every device on your system. If broken by a cable cut or device tampered with it will trigger the internal speakers and if the panel is set it will trigger external sounders and strobes as well. CHIME Chime is similar to a doorbell. It can be used to alert a user to a certain zone being triggered for example a front door contact can be used to know when a door is opened or a detector can alert a user to a room being entered. CHIME is only active when the panel is UNSET ass when it is SET the zones functions take over. DOOR SENSE SETTING This allows you to have variable FULL SET EXIT TIME. You can set your EXIT time to 90 seconds and when you are setting your system to leave the premises the exit time will drop to 8 seconds as soon as the EXIT door has closed. This means in affect you have an 8-90 second exit time. THE * KEY (STAR) This is commonly used as an ACCEPT or CHANGE button THE # KEY (HASH) This is commonly used as RESET, CANCEL or EXIT 11

SERIES AND PARALLEL Here is a simple example of SERIES and PARALLEL wiring. Notice how the Power and C & D lines are in parallel and the Tamper lines are in series. Manual Version 1.2 13/03/97 C&K Systems Ltd. Unit 24 Walkers Road North Moons Moat Industrial Estate Redditch Worcs. B98 9HE Tel : +44 (0)1527 68111 Fax : +44(0)1527 68222 Technical Support : 0345 660533 9am - 5pm weekdays Local rate call only - UK Only ZONE ZONE USE / LOCATION RESISTANCE 1 Ω 2 Ω 3 Ω 4 Ω KEYS ENTERED 12

5 Ω 6 Ω 7 Ω TIMER VALUE KEYS ENTERED FULL SECONDS NIGHT SECONDS EXT SOUNDER MINUTES TICK BOX 1 2 3 4 5 6 7 CHECKED EXTENDED OPTIONS BATTERY VOLTAGE V AUX. VOLTAGE V INSTALLED BY THIS INFORMATION SHOULD BE KEPT EITHER INSIDE THE CONTROL PANEL OR WITH THE INSTALLER. IT CAN BE USED TO REFER TO PROGRAMMING DETAILS WHEN NEEDED. 700L CONTROL PANEL ST- NO BELL+ 0V -R SONADE 2000 STROBE- B D A T FLASHGUARD XL+ STROBE- SIREN- SUPPLY+ SUPPLY- TAMPER OUT STARLIGHT 2000 ST -R +H -H RTN ACTIVEGUARD STB- -S +12V -12V RIGHT HAND TAMPER ACTIVE GUARD 3 ST- -SW V+ V- RET SECURIGUARD STROBE- S- SUPPLY+ SUPPLY- LEFT HAND TAMPER NOVA GUARD 2+T STROBE- S- 12V+ 12V- R SPIRIT AU1000 STB- TRG- HOLD OFF + HOLD OFF - RTN- GENERAL TERMINALS STROBE TRIG - SIREN TRIG - SUPPLY+ SUPPLY- TAMPER RETURN 13