Dust Concentration Meter

Similar documents
Snifter ATEX22 VERSION. User Manual. Distributor

Sintrol Snifter A1+ Manual. Version 1.2.2

PARTICULATE EMISSION MONITORING

Oil Leak Detector NAR300 System

Sitron s CF Line of Flow Switch Monitors

Snifter. User Manual. Distributor

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Oil Leak Detector NAR300 System High Temperature

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA)

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

INTRINSICALLY SAFE S314X AND S315X

SIMRAD GD10PE IR GAS DETECTOR

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

DB5 Intrinsically Safe Sounder Type DB-5

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

GAS DETECTOR ST400EC PART.NO

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

SET-2000 Hi Level/Oil

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

BC-R10 Series. Burner Controllers

Dust Alert 75. *shown with optional external keypad and display

Lecture 5 Particulate emission control by electrostatic precipitation

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

INSTRUCTION MANUAL (ATEX)

Arc Fault Protection System D1000

General Specifications

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

Bristol Babcock Oil Content Monitor "oil in water"

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

OEM Sensors for HVAC manufacturers Heat recovery Chiller

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Dräger Polytron 5720 IR Detection of carbon dioxide

Analog Transmitter AT1000 AT1

PolyGard 2-channel Gas Controller MGC-03

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Dräger Polytron 7000 Fixed gas detector

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

4) Intrinsic Safety Certification

OilSET-1000 (12 VDC)

Model OEM-2 INSTRUCTIONS FOR USE

D1000 Arc-fault Protection System

Zircomat Oxygen Analyzers

Power Supply Display Module PSDM. Installation and Operation Manual

Dräger Polytron 5100 EC Detection of toxic gases and vapors

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

HYGROPHIL H process hygrometer

Zirconia Oxygen Gas Analyzers

Operating Manual MS220KA and MSR220KA

Dräger Polytron 5100 EC Detection of toxic gases and vapors

ACCURATE ELECTRONICS INC

High Pressure Conductivity Monitor

Certificate of Compliance

INSTRUCTION MANUAL FLOAT TYPE LEVEL SWITCHES HITROL CO., LTD.

IN-SITU ZIRCONIA OXYGEN ANALYZER

Earth-Rite II PLUS Static Earthing System

Dräger Polytron 5720 IR Toxic Gas Detection

DICTATOR Hold-Open Systems for Hazardous Areas

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Operating Manual MS220DA

Heated Gas Sampling Probe PSG Basic

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Transmitter for O 2 ZD21. Operation Manual

Hazardous Area Zirconia Oxygen Systems

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Class 1 laser beam sensor safe for your eyes

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Class 1 laser beam sensor safe for your eyes

THE INDUSTRIAL APPROACH TO DUST MONITORING

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

SIMRAD GD10 IR GAS DETECTOR

Instructions for the BASIC BCRW Fan, Sizes General

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Using the DewTrak II Dew Point/ Humidity Transmitter

Flostop TS D7E and A8E. Operation Manual

Quick Start Guide For the

Sensepoint XCL Fixed Gas Detector

Flopurge TS. Operation Manual

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

DAIKIN Modular Inverter Air Cooled Chiller

Users Manual Pury 250e Gas Purification System

FTW04. Application. Types Available. Security Advice Caution. Surface mounting room sensor for relative humidity and temperature.

SET-2000 Oil/Sludge 12 VDC

OPTIBAR P 1010/2010 C Supplementary instructions

RS Pro Infrared Temperature Sensor

Models TX-KE and TX-KP Toxic Gas Transmitters

Control Panel Basics Volume 1

Transcription:

Dust Concentration Meter To Sense Breaks or Tears in Filter Bags, to Improve Product Quality, and to Eliminate related Environmental and Safety Risks Triboelectric Dust Monitor

Particles in the air are a concern for the production lines of each and every industry. Leakage and mixing of particles such as dust are serious concerns for environmental quality, traceability of products, and improvements in productivity. Since dust deposits have been recently recognized as a safety issue, the timely detection of leaks and the continuous monitoring of dust concentrations are crucial. The Matsushima PFM dust monitors can be used to measure the concentration of dust and other air particles under various conditions. High Performance Produces the same high performance as optical systems at lower cost. Nine monitoring levels of dust concentration. Detects solid particles with diameters from 0.3 μm to 100 μm. Provides level alarm signal (1C with compact type, 2C with remote type) as well as fault alarm signal (1C). Requires no additional equipment such as an air purge and cooling system (Max process temperature: 250 C) For high-pressure applications up to 200 kpa. Easy to use Requires no special training or skills. Easy to install and to adjust. Simply use the switches to select the monitoring level of dust concentration and to adjust the sensitivity. Easily adjust concentration monitoring levels with a digital display for viewing (standard). Two styles are available: a sensor with an integrated transducer or a non-integrated type. Changeable probe length from 300 mm to 1000 mm. (Can be extended to 1000 mm for special orders.) : Measurement range, integration time, and contact output can be adjusted. * Easy Maintenance All components are made in Japan for ensured high quality and excellent customer service. Requires only periodic cleaning of the probe for maintenance. (Approximately every three months under normal operation conditions.) Uses advanced digital technology for high quality and reliability. Speedy and accurate service including calibration support. Easy replacement of damaged probes. High Level of Dust Concentration (Broken Filter) Dust Monitor with Optical Sensor (Other Company) High Level of Dust Concentration (Broken Filter) PFM Triboelectric Dust Monitor (Matsushima) Comparison of Dust Concentration Levels The Matsushima PFM dust monitor can measure the dust concentration as accurately as a high-cost optical sensor under the same conditions.

Operation Principles When solid particles such as dust in gas emissions come into contact or pass through the triboelectric probe, a charge transfer is produced in the probe. The charge is converted to a current signal, and a measurement signal ranging from 4 ma to 20 ma DC in proportion to the amount of particles is output. R1 Attachment Screw Transducer Insulated Part Probe Exhaust Gas Containing Dust Flow Applications for Dust-collecting Equipment and Others Possible to monitor multiple dust collectors It is possible to monitor multiple dust collectors by utilizing timing of periodical backwashing impulse. Dust collector 1 Dust collector 12 Dust monitor Dust collector 13 Impulse Dust collector 2 Impulse Vent Cement Factories For coal ash and other raw materials. For cement and concrete products. For kilns, AQC(Air-quality Control) systems, and other equipment. For slug- and fly ash. Ironworks For steel sintering. For casting. For coke ovens. For recycling-related facilities such as those for waste disposal of plastics. Chemical Factories For catalyzation. For smoke removal. Automobile Factories For casting. Waste incineration Plants For monitoring the environment. For incinerators. For fusion furnaces. For high-temperature incinerators used to cut emissions such as dioxins. Rubber and Carbon Factories For monitoring of dust accumulation in ducts. For handling raw materials. Fertilizer Plants For preventing mixture of fertilizers. Spice and Paint Factories For traceability-related equipment. Gas Extraction Equipment for Boilers For generators. Other Dust-collecting Equipment Optional probe Teflon-coated probe Dramatically improved anti-corrosion performance Life of the probe can be extended dramatically with this teflon-coated probe even in emission of corrosive gas (chlorine, sulfurous, nitric acid, and others). Teflon coating is also effective for reducing dust adhesion. Item Range of coating Coating material Coating thickness Details Probe (part exposed to gases) Conductive Teflon 40 μm Sensor after Teflon-coating

D u s t M o n i t o r P F M S e r i e s Triboelectric dust monitor with concentration-level correction Easy correction to a close approximation of values obtained by JIS-equivalent methods By simply entering a concentration correction factor to the current signal representing the amount of particles measured by the sensor, the output value can be corrected to an actual dust concentration level approximation that may be obtained by lab measurement standard.(range of correction: 0.1 to 2.0 times) Continuous monitoring is possible at a lower cost compared with the lab and optical systems. Before Correction After Correction Adjusted to match lab measurements Transducer for Remote Type PFM-KCU12, PFM-KCU14 Actual concentration levels Concentration measurements Triboelectric dust monitor for high-temperature applications Can be used in applications at a maximum process temperature of 400 C! Radiation fin protect the sensor from the heat, so the concentration levels of dust can be measured at a process temperature of 400 C. The probe can be used for dust collectors installed at waste incinerators and fusion furnaces where measuring dust is difficult. Dust particles Radiation fin protect the sensor from the heat Sensor for Remote PFM-M11PT

Specifications Sensor Sensor Type Model Number Sensor with Integrated Transducer Standard PFM-M01E Standard PFM-M11P Remote Type Sensor High-temperature Applications PFM-M11PT Explosion-Proof Type (Ex ib IIB T4) PFM-M01PEX Construction Approx. Mass Power Supply Power Consumption Dedicated Signal Cable Length Concentration Level Display Contact Sensor and transducer are Sensor,transducer& Zener Barrier are separately installed. separately installed 2.1 kg 1.3 kg 2.1 kg 1.3 kg From transducer Sensor with integrated transducer 80 to 240 VAC 50/60 Hz 4 VA 10-segment LED (Lights up at every change of 10%) 1a for limit 1b for fault Contact capacity: 250 VAC, 2 A 30 VDC, 2 A 5 m (standard). Can be extended to 100 m for special orders. On remote transducer From transducer Analog Enclosure Ambient Temperature Equipment Particle Size Particle Concentration Process Temperature Gas Flow Velocity Humidity Pressure Measurement Range Data Averaging Probe Length Mounting Transducer for Remote type Transducer Type Model Standard Number Explosion-Proof Type 4 ma to 20 ma DC (Load resistance: 500Ω max) 9 levels Time setting up to 30 seconds : Housing cover and lead outlet must be closed. * Standard PFM-KCU11 PFM-KCU01 Protection rating: IP65 20 to +65 C (Without condensation) From transducer 0.3 μm min. 0.1 to 1000 mg/m 3 (Reference concentration) 250 C max. 400 C max. 60 C max. 4 m/s min. (Constant velocity) 40% max. 200 kpa max. Use transducer to make settings Use transducer to make settings 300 to 1000 mm (When length of insulator is 58 mm) R1 screw with one-inch socket With Concentration-level Correction PFM-KCU12 PFM-KCU02 PFM-KCU14 PFM-KCU04 Dust-proof&drip-proof* 20 to +60 C (Without condensation) Z961/Z964 Approx. Mass Power Supply Power Consumption Ambient Temperature Enclosure Concentration Level Display 0.7 kg 110 VAC or 220 VAC, 15 to +10%, 50/60 Hz* 7 VA 20 to +50 C (Without condensation) Protection rating: IP20 4 digit 7 seg LED Unit of measurement % mg/m3 Contact Analog Correction Range Measurement Range Data Averaging Mounting Equipment : Specify the power voltage when you order. * 1cX2 for limit 1c for fault (Contact capacity: 250 VAC, 2 A) 4 ma to 20 ma DC (Load resistance: 500Ω max) 0.1 to 2.0 times (at 0.1 intervals) 9 levels Time setting up to 30 seconds Wall or DIN rail mounting Explosion-proof enclosure Protection class Ratings Ambient Temperature Ambient humidity Mass Ex ia II IP20 Uo 17.4 V Io 190.3 ma Po 430 mw Um250 VAC 50/60 Hz 250 VDC 20 to +60 (Without condensation and freeze) 75 max. 150 g Note: For a single detector, 2 zener barriers are the system configuration of explosion-proof intrinsic safety. Connecting the earth of the zener barrier to the DIN rail & connect the earth separately by A-class grounding.

Dimensions (mm) Sensor with Integrated Transducer Standard PFM-M01E Wiring AC AC NC COM NO COM + Power Supply Alarm Contact 4 to 20 ma DC One-inch Socket: 43 mm Long Housing: Aluminum Casting Mounting Boss R1 Probe: SUS316L (Note3) M5 Bolt 10 dia. 18 dia. 104.5 dia. Insulator: A (Note1) PTFE Earth Terminal M4 (Note4) 300 (Note2) 58 (Note2) (57) (134.5) (26) Indication window Closing plug Lead Outlet: M20 1.5 104 134 (26) Sensor for Remote Standard/Explosion-Proof Type PFM-M11P/M01PEX Sensor for Remote High-temperature Applications PFM-M11PT Transducer for Remote type PFM-KCU 80 66 Mounting Holes: 4 5-mm dia. (82) (82) Indicator Lead Outlet: G1/2 (30) (85) Lead Outlet: G1/2 (30) (85) 146 35 160 Setting Buttons Signal cable: 5m signal cable included (Note5) Housing: Aluminum Casting Earth Terminal M4 (Note4) Wiring (standard*) Transducer TB 4 TB 1 TB 2 TB 3 F.G AC AC COM NO NC COM NO NC COM NO NC OUT 5P GND GND 5N Power Supply M5 Bolt Mounting Boss R1 One-inch Socket:43 mm Long Insulator: PTFE 18 dia. Probe: SUS316L (Note3) Alarm Contact 1 Explosion-proof type must have * : Zener Barrier between Sensor and Transducer. A (Note1) 10 dia. (90) (57) 300 58 (Note2) (Note2) Contact 2 Specially Designed Cable OUT 5P GND GND 5N Probe Signal cable: 5m signal cable included (Note5) Housing: Aluminum Casting Earth Terminal M4 (Note4) Radiation fin: Aluminum Mounting Boss R1 One-inch Socket: 43 mm Long Fixing screws for board Insulator: Ceramic Probe: SUS316L (Note3) + 4 to 20 ma DC To cable glands FG FG 98 dia. 18 dia. M5 Bolt 34 dia. A (Note1) 10 dia. (90) (121) 150 300 (Note2) DIN rail (35mm) Rail Socket Zener Barrier Z961/Z964 60 68 Signal cable 12.512.5 Standard 0.4m (Cable included) (Note5) 115 8 7 6 5 43 43 21 21 Safety area terminal Earth Terminal screw:m3 Hazardous area terminal Signal cable(note5) Signal Cable (Note5) Earth terminal (Note6) 115.7 Zener TYPE:Z961ExibB Barrier Uo=17.4V,Io=190.3mA,Po=430mW PFM-SYS-EX Lc0.1mH,Cc0.1uF Um=AC250V 50/60Hz DATE DC250V SER.NO -20Ta+60 Please set it up in (25.6) the nonhazardous Please area. refer TC20399 to the manual. Arbitrary conversions or are modifications not permitted. Please comply to the A-class ground grounding resistance MATSUSHIMA (with of 10 or machinery less) alone. Lab Co.,Ltd. Notes: 1. The minimum space (A) between the socket and the insulator must be 10 mm. 2. The length of Insulator and Probe can be changed at option. 3. Do not touch the probe with bare hands. 4. Be sure to ground the ground terminal. 5. Use a shielded cable for the signal cable. 6. Please connect earth terminal separatery. A-class grounding(with the ground resistance of 10Ω or less) 8 7 6 5 Caution Read the instructions to ensure correct and suitable application of products. Contact our nearest sales office when using our products for any systems used in situations which may be life threatening. C45A0456-1 Kitakyushu Japan DIN rail (35mm) Distributor HEAD SALES OFFICE / FACTORY 1-8-18, Norimatuhigashi, Yahatanishi-ku, Kitakyushu, 807-0837, Japan Tel: +81-(0)93-691-3731 Fax: +81-(0)93-691-3735 POHANG REPRESENTATIVE OFFICE Oddyssey Bldg. 1F, 41, Jukdo-ro, 28beon-gil, Buk-Gu, Pohang-Si, Gyeongsangbuk-do, 791-841, Korea Tel: +82-(0)54-274-3731 Fax: +82-(0)54-274-3731 http://www.matsushima-m-tech.come-mail:info@matsushima-m-tech.com SHANGHAI DAHONG MATSUSHIMA MACHINERY CO., LTD. 70 Hengcang Road, Dahong, Malu, Jiading, Shanghai 201818, China Tel: +86-(0)21-59514138 Fax: +86-(0)21-59514139