Model SPA-308 HOT TUB OPERATING INSTRUCTION

Similar documents
Model SPA-516 HOT TUB OPERATING INSTRUCTION

Model SPA-8138 HOT TUB OPERATING INSTRUCTION

PROGRAMMING INSTRUCTIONS

USER MANUAL OF KL8300 SYSTEM

HOT TUB. Model SPA-313. Serial No: POPERATING INSTRUCTION

User manual Whirlpool

beyond 260VAC, then LED shows. In these two kinds of situation, the system will not go into normal operation.

Massage Bathtub. Instructions of Installation and Use. Preparations MT-RT1804. Cleaning & Maintaining

Installation Instruction of AM124ETL-L TS-series Control panel

Preparations MT-RT1806. Cleaning & Maintenance. Precautions

Installation Instruction of AM168 TS-series Control panel

15,000 BTU Portable Air Conditioner

SG User Manual

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

DIGIHEAT IN LINE HEATERS

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

INSTALLATION AND USER MANUAL

System. For a better understanding of this product, please read this user manual thoroughly before using it.

WINE COOLER INSTRUCTION MANUAL

I. U881 Series Structure...1 II. Security Advice...2 III. Technical Parameter...3 IV. Install U881 Sauna Room V. Electricity Supply And Water

INSTALLATION AND USER MANUAL

OPERATOR S MODEL HHC-901 HHC-904 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

99 F PREHEAT. C d. Topside Controls for Spas with Three Pumps

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

TC-NHP01-A, TC-NAC01-A Comfort Series Non- Programmable Thermostat. Owner s Manual

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

Wired Controller XK60

ML550, 551, 554 Panel Operation

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Briza Line. Digital Display Unit (Room Thermostat) Model BLC 13-RS Wall Mounting Cat Model BLC 33-RS Semi Flush Mounting Cat.

Installation and Operation Manual

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

Installation and Operating Manual

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

Portable Air-conditioner

Wine Cooler. Instruction Manual PWC-24ZWX

HT-2 / 9600 Series Control Contents

No advanced advice will be submit before we change our design and size. The pictures may be a little different from the real products.

SERVICE MANUAL UNI SPLIT SERIES. ASC-xxBI, ASD-xxBI, ASF-xxBI, ASGE-xxBI, ASGE-xxBI-3

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

No advanced advice will be submit before we change our design and size. The pictures may be a little different from the real products.

C&H NORDIC Commercial 4 SERVICE MANUAL

Europa Shower Cabinet

Inverter Swimming Pool Heat Pump

Oceanic Sauna Heater Manual

Installation and user s manual Read carefully and keep it for later reference

Reverse Cycle Split System Air Conditioner

PORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING

HEALTH POT MODEL: EHP-E1881G(WH) EHP-E1882G(OR) Owner s Manual. Please read this manual carefully before operating your set.

Xcelsior Spa Pool System

LEVENS STEAM SHOWER ENCLOSURE

Part 8 PROBLEMS AND SOLUTIONS

EL/GL Series - Mach 3 ML550 User Guide

Portable Air-conditioner Use and Care Manual

OWNER S MANUAL DUCTED INVERTER. (English) (SDHV SERIES)

FPC-02 Series. Installation and Operating manual

Medical Refrigerator

USER MANUAL

spatouch Menued Control Panels

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

E1000 Portable gas detector

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Swimming pool värmepump Heat Dragon

FAN COILS wall mounted

155mm. 820mm. 540mm E D. 940mm. 600mm

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

Packing list. Packing 1. Packing 2. Packing 3. Spare parts list

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Harmo Powerpack Horizontal Units Installation & instruction manual

Bubble Massage Bath (Include Electronic Drain)

Operator: Save these instructions for future use!

EL/GL Series - Mach 3 MLM990S User Guide

E-17 Flammable Gas Detection and Alarm System

OFFICE PRO 36 and OFFICE PRO 60 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE AND READ ALL SAFEGUARDS

PDA20DX Air Purifying Dehumdifier Manual

IMR EX610. Portable Gas Detector. Operation Manual

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

220V 3200 WATT COMMERCIAL SINGLE INDUCTION COOKTOP OPERATION MANUAL

FREWIN STEAM SHOWER ENCLOSURE

CoziStat. 1. Introduction and Brief Description COZISTAT INSTALLATION I NSTRUCTIONS &OPERATING MANUAL

OPERATION & INSTRUCTION MANUAL. itouch GS08M(9kW & 18kW)

KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4.

Luxury Spas Inc. Instruction Manual E-35 Steam Shower. Instruction Manual 1

ARLEY STEAM SHOWER ENCLOSURE

Genus III Pool and Spa Controller

Hand Dryer Installation & User Manual

HEALTH POT MODEL: EHP-G1583G(RD) EHP-G1584G(RD) Owner s Manual. Please read this manual carefully before operating your set.

/ De Longhi Appliances via Seitz, Treviso Italia

VADA - Rain2Main Automatic Rainwater Controller

Owner s Manual 33-bottle Under-Counter Wine Cooler Model: WC-3302US

PORTABLE AIR CONDITIONER

Sauna & Steam. SAUNA HEATER with OCSB/LB CONTROLLER Assembly and operating manual PRODUCT IMAGE

Transcription:

Model SPA-308 HOT TUB OPERATING INSTRUCTION 1

1. I Illustration to buttons Fig.1:Control Panel Frequency up- searching / Minute On-off/Setting confirm Frequency down- searching/ Hour Radio or CD Switch/ On-off + Volume up/ Set switch Blower On-off/ or Switch - Volume down/ Open Spa Light On-off MEM Radio channel Memory/ Lock Surfing pump 1 On-off SET Radio channel read / Close Surfing pump 2 On-off Lasting Circulation Cleaning On-off Surfing pump +circulaltion pump 3 On-off/Set Circulation Cleaning Time Heating On-off / Set Pre-heating Set Temperature Note:.The functions listed with bule letters only works on the condition of on-off Chart 1 II Function Summary 1 Max. with 6 KW heating system, pre-heating seting, water temperature displaying and setting 2 Max. with 2 pcs surfing pumps,1 pc circultion pump, and one pc air blower. 2

3 Spa light and ozone setting 4 CD audio-input / Display of radio frequency,it can be preserved 10 channels 5 Volume display and 87 volume adjusting 6 Circulation cleaning/ time set circulation cleaning 7 24 hours display and setting 8 Memory preserve once power off 9 Fahrenheit & Celsius can be mutually switched 10 Antifreezing functions 11 Keys with backlight 12 Lock settingl 13 Three-phase or single-phase available,can be choosed 110-120VAC or 220-240VAC 14 Choice with offering a AC for circumscribing DVD or TV 15 Choice of power controlled III Operation Fig.3::Normal Temperature Display Fig.4:Senor on/short circuit Display 1 When you first turn on the spa, the backlight control panel is dim and LCD shows current time and temperature. If spa happen with the short circuit the panel will display code E1. When the radio frequency is displayed ---- it indicates that the spa is in power off mode, and pre-heating and circulation cleaning function are in off status. 2 Lock memory Mode: It is an optional function. Key board will be locked by pressing MEM once when panel is in off mode. Pressing continuous twice of MEM to unlock the panel, the word LOCKED will disappear. 3 Time Adjusting: In the status of Power off and unworking of pre-heating and circulation cleaning. Pressing or your desired time. to start time adjusting. When Minute and Hour flashing, you can adjust It will be added one hour when pressing each time and the hours can be adjusted continually when pressing without stopping. The hour adjustment range is 00-23. 3

It will add one minute when pressing each time and the minutes could be adjusted continually when pressing without stopping. The minute adjustment range is 00~59 The system will quit the time-setting status automatically after 6 seconds without pressing any buttons 4 Pre- circulation-cleaning Setting: The display will show clearly whether circulation clearning is work or not. See following Fig 5-6: AM AM Fig.5:Circulation-cleaning off Fig.6:Circulation-cleaning on Pre- circulation-cleaning Setting should be under the power off status. just turn on the spa, LCD will display --- 1) Press to start Circulation-cleaning setting mode, LCD showes and it is flashing.you can set the pre-circulation time simultaneously(refer to chart 2 and illustration 2). Press again to turn off the circulation cleaning,and the will disappear. 2) Press (minutes)and (hours)to adjust the time. It will add 1 hour when pressing each time and the hours could be added continually when pressing without stopping. The adjustment range is 00-23. It will add 1 minute when pressing each time and the minutes could be added continually when pressing without stopping. The adjustment range is 00~59. 3) Press to set lasting time of circulation. 4

It will be added 5 minutes by pressing and 1 hour by pressing each time The maximum working time is 19 hours and 55 minutes. 4) Finally Press to confirme all settings. Notice: The system will be exit automatically by pressing key of 1) Pre-circulation setting be turn off 2) starting time of circulation 3) Lasting time of circulation 4) Finished Chart 2 ***Notice*** 1 All the setting of Circulation-cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not working while setting the circulation cleaning. 5

: 5 Preheating Setting (if required): The display will show clearly whether preheating work or not. See following Fig 7-8: ON OFF Fig.7:Pre-heating On 图 8:Pre-heating Off Pre- heating setting should be under the power off status. just turn on the spa, LCD will display --- 1) Press to start Pre-heating setting mode, LCD flashes of ON, You can set the pre-heating time simultaneously (refer to chart and illustration 3). Press to turn off the pre-heating,and the will disappear on panel. 2) Press (minutes)and (hours)to adjust the time. It will be added 1 hour when pressing each time and hours could be added continually when pressing the without stopping. The adjustment of hours is 00-23 It will be added 1 minute when pressing each time and minutes could be added continually when pressing the without stopping. The adjustment range is 00~59 3) Press to set lasting time of circulation. It will be added minutes by pressing and 1 hour by pressing each time The maximum working time is 19 hours and 55 minutes. 4) Press again to set the water temperature(please refer to Chart 3 and illustrate 4). Press button to change the temperature. The range of temperature setting is: 15~43 5) Press to confirm all settings. Notice: The system will be exit automatically by pressing key of 6

1) Pre-heating setting is turn off 2) Starting time of pre-heating 3) Lasting time of circulation 4) Preset temperature 5) Finished Chart 3 ***Notice*** 1 All setting of preheating must be in Power OFF mode, just turn on the spa,the LCD will display --- 2 Please note that it shows "on" or "off" on the LCD. "on" means preheating is turned on mode. when the time reaches your desired time, heater will work. If panel shows "off", means that heater not be set. 3 Circulation PUMP and HEATER not working while setting preheating. 6 About Pre-heating When the time reaches your desired time, LCD shows ON and the tub is filled with water, heater works. circulation pump works simultaneously. The count down time will be shown on the LCD screen, till the preset time finished. The preheating will be turned off automatically once the preset time is finished. 7

Or Pressing the key can stop preheating. ***Notice*** i. When setting temperature is lower than or equal with current water temperature, Even preheating is on status, the circulation PUMP and HEATER are not working ii. When the HEATER is a I type frame,the power of circulation PUMP must reach 1HP Otherwise the heater don t work due to not enough water pressure to drive pressure switch. iii. If above two condiction still not make the heater work, Please short the line of water pressure switch 7 Circulation-cleaning: As the current time is as same as the preseting time, the preset is on too and the tub is filled with water, the circulation cleaning will start, the circulation pump works at the same.. The LCD shows the countdown time. All the surfing pumps and blower will work for 30 seconds at every 30 minutes. The Ozonier works at every 15 minutes. The circulation cleaning will be turned off automatically once the countdown time is finished or By pressing the key to turn off directly. 8 Operation to Power ON/ OFF Pressing the key in power-off status to enter the power-on status. To pressing the in the status of power-on to enter the power-off status. The LCD screen shows the on or off.see following Fig.9-10 AM OFF AM OFF Fig.9:Power Turn OFF Status Fig.10:Power Turn ON Status 9 Temperature setting: In the status of Power-on and HEATER is working.it will add 1 centigrade by press each time,the temperature will be added continually till reach 43 centigrade(109 Fahrenheit ) by press without stop.press again,and the temperature is show 15 (59 Fahrenheit) The range of adjustment is: 15~45 (59~109 Fahrenheit) 10 Operation Radio & CD: 8

AM Fig.11:Radio frequency is 105.2 MHZ,Save the present frequency to channel 3 (Save channel) or Exchange the frequency form channel 3 to the present (Searching channel) PUMP3 I key is the ON/OFF key of radio and CD and it is only available in the status of power on. The first pressing is turning on the radio,the second pressing will turn off the radio and turn on the CD at the same time,and the third pressing,will turn off the radio and CD simultaneously. Ⅱ LCD will show present frequency and volume of the radio after turning on the radio Ⅲ In the working of radio, The volumle of the present radio frequency can be changed by pressing and Ⅳ Pressing the key SET will take out the memorized radio frequency,pressing the key SET continually will take out the memorized radio frequency from channels will be saved at present channel by pressing this key continually If none of the channel, LCD will display --- MEM MEM Ⅴ Press the key could memorize the present radio frequency,pressing the key continually will memorize the present radio frequency in different channel The channel of max is 10,Name of channel is 0-9 Ⅵ The volume can be changed by pressing key 11 Operation of Pump: VOL+ SET and OPEN The Button, operates pump 1;The Button PUMP2 operates pump 2;The button PUMP3 operates pump 3,Also the pump 3 is the circulation pump When pump 3 is turned on the LCD will show, whether the heating and circulation is on or off. The LCD will show when pump3 is off and the heating, including pre-heating and circulation is about to start 12 Operation of lasting circulation cleaning: Press the key at any time to turn on or off the lasting circulation cleaning, work mode is like the preset circulation cleaning. The surfing pumps and blower work for 30 seconds at every 30 minutes. Ozonizer works for 15 minutes at every 105 minutes,and repeat in this program. Ozonater only work under the circulation cleaning works. IMPORTANT: Please ensure that the ozone function is not in use whilst bathing in the spa 9

During the lasting circulation cleaning,press key can stop the heating,but start again the heating. 13 Operation of spa lights: Press the key to turn ON/OFF of the the LED lights and the Fiber optic lights. 14 Setting the constant Temperature Settings: 1) Pressing the button will start the constant temperature heating. 2)With the setting above, the circulation pump will work automatically. 3) If the temperature is set at 35, when the water temperature reaches or exceeds 36, the heater will be turned off automatically and the circulation pump will stop after 5 seconds. When the water temperature reaches or lower than 34, the heater will start up again. 4) In the case of an error the LCD shows E1 or FF. If this happens, the thermostatic heating sytem will NOT be available, the heater doesn t work. 15 Operating the Air Blower: Press controls the blower 16 Fahrenheit & Celsius Temperature shift: In the status ofpower off pressing the key can change the mode of Fahrenheit & Celsius degree 17 When there is no water in the spa. All surfing pumps, and heating system can not start up. However the corresponding signals will flash on the LCD. 18 Prevent freezing function: This function is only available while the spa is on normal power supply.the heater & circulation pump will work automatically once the water temperature is at below 5, when the water temperature is reach at 10, heating will stop. IV Electric parameters 1 Performance index: Rated voltage: 220V/50Hz Maximum working current:60 A/220V-240V~ Voltage-resistance:1250V/1 minute without penetration Isolative resistance: 10MΩ Water resistance grade:ipx5 Electric shock resistance:first grade ((2) Output loading index Heater: AC220V/3KW x 1. Air pump:ac220v/700w 1 Spa light: AC12V/20W Radio: 1) Frequency Range: FM: 87.0~108.0MHz Water pump: AC220V/2 HP 2 Ozone: AC12V/15W 10

2) Maximum Output Power: 10W 3) Speaker:8Ωdamp proof speaker 5.Warning Information a. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. b. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. c. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. d. Children should be supervised to ensure that they do not play with the appliance. e. Details concerning cleaning and other maintenance f. Maintenance of water purity, especially PH values and chlorine concentrations. g. Cleaning and disinfection h. Use and installation of a cover. i. Disposal of water j. Precautions to avoid damage due to water freezing k. Precautions to avoid damage when the appliance is left empty for extended period. 2.2 Sub-clause 7 The installation instruction shall state the substance of the following: - Earthed appliances must be permanently connected to fixed wiring; - The appliance should be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 ma. - The floor has to be capable of supporting the expected load. - An adequate drainage system has to be provided to deal with overflow water. - Details of how to follow the wiring rules, for example, specifying that parts are installed in the correct zone and that equipotential bonding is carried out. 1 DANGER:RISK OF ELECTRIC SHOCK,Connect only to a circuit protected by a Ground WARNING Fault Circuit lnterrupter. 2 Grounding is required. The unit should be installed by a qualified service representative and ground. 3 FOR YOUR SAFETY-This product should be installed by a professional service technician,qualified in hydrotherapy bath installation. 4 lt s prohibited to cover the instrument with something while opeating. 5 when using at the first time,be sure there is water in heater pipe before staring. 6 parts containing live parts, except parts upplied with safety extra-low voltage not Exceeding 12V,must be inaccessible to person in the bath; 8 earthed appliances must be permanently connected to fixed wiring; 9 the appliance should be supplied through a residual current device (RCD)having a rated residual operating current not exceeding 30 ma. 10 If the mains cord of this appliance is damaged,it must only bereplaced by our service representative,as special tools and/or parts are required 11

Solutions of Fault Phenomenon Reason How to Solve the problem No power supply 1. The electric leakage switch was breaked off 2. The Fuse be break off 1. Check and eliminate the malfunction, restart the spa 2. Please change fuse No display on control panel LED light not work Ozone not work Displaied E1 FF in control panel being incapable of activate water pump,and water pump icon flashing Heater not work, and heating icon on panel flashing Leakage 1. The plug which connected with the panel loose or disconnected 2. The Panel happened with malfunction 1. Power of the light be break off 2. Fuse be break off 3. light be burn 1. Ozonater burn 2. Fuse be break off 3. Cable of the ozonater be cut off 1. temperature detector be cut off or shortcirculate 2. plug of the temperature detector be nundated by water 1.water not achieve the appointed level 2. water detector not connect well 1. setting water temperature lower then the water temperature 1. silicon plaster not good 2. PVC plaster not good 3. Blow out of the water pipe 1. to connect the plug of the control panel and the main box 2. Change a new control panel 1. To check if cable of the light is well connected with main box or not 2. Change a fuse 3. Change a new lampwick 1. Change a new ozonater 2. change a fuse 3. check if the cable of the main power is connected with the main box or not. 1. Connect the temperature detector 2.Change a new temperature detector 1. To add more water to make it up to the water detector 2. To re-connect the line of water detector 1. set the temperature degrees higher than the water in tub temperature(between 15 and 43 C 1. To remove the jets then re-install one 2. To plaster once again Change water pipe 12

13

14

15