[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

Similar documents
CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

TRANSACTIONS ON ADVANCEMENTS IN SCIENCE AND TECHNOLOGY (TASTONLINE)

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

Heat Transfer in Evacuated Tubular Solar Collectors

Experimental Study and Analysis of Flat Plate Solar Water Heater with Different Flow Rates using of Circulating Pump

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

Design and Experimental Studies on Modified Solar Dryer

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Design And Analysis Of Centrifugal Pump

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Improving Fired Heaters Reliability using Inclined Firing Technology

Mallikarjun 1, Anandkumar S Malipatil 2

Effect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower

Effect of the Use Pattern on Performance of Heat Pump Water Heater

Study on Performance Evaluation of Forced Convection Solar Dryer for Turmeric (Curcuma Longa L.)

Numerical Analysis of Water Temperature Distribution in the Tank of. ASHPWH with a Cylindrical Condenser

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2

Design, Development and Experimental Investigation of Volumetric Air Receiver

Experimental Investigation of Flat Plate and V- Trough Solar Water Heater by using Thermal Analysis

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Modification of Passivation Unit in Galvanizing Line

Compression of Fins pipe and simple Heat pipe Using CFD

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

To investigate the surface properties for increasing efficiency of solar water heater

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Study of air circulation inside the oven by computational fluid dynamics.

Heat transfer and heating rate of food stuffs in commercial shop ovens

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Indoor Air of a Double-Storey Residential House in Malaysia

Numerical study of heat pipe application in heat recovery systems

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

CHAM Case Study Numerical Simulation of a Air-to-air Cross-flow Heat Exchanger

Design Optimization of Atmospheric Water Generator

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Solar Drying Techniques And Performance Analysis: A Review

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Dae-Hyun Jin. 8/2018-Present Assistant Professor of Mechanical Engineering, Taylor University, USA

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Performance analysis of overlapped solar air heater using CFD

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Performance analysis of solar water heater in NEH region of India

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Performance Analysis of Centrifugal Fan by CFD

Basic CFD model of heat pipe

FABRICATION AND COMPARISON OF SOLAR WATER HEATER WITH AND WITHOUT SEMI CIRCULAR TROUGH

The Role of Computational Fluid Dynamic and Aeroacoustic Simulations in Reducing the Noise of a Forward-Curved Blade Radial Fan

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER

Air Flow Study inside the Supermarket Refrigeration System

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

Design Optimization of Variable Geometry Microchannel Heat Exchangers

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

Heat transfer enhancement in an air process heater using semi-circular hollow baffles

ANALYSIS ON EFFECT OF TEMPERATURE ON MOISTURE SEPARATION IN AIR COMPRESSOR

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Vertical Distribution of Air Temperatures in Heated Dwelling Rooms

DESIGN, ANALYSIS AND FABRICATION OF THERMOELECTRIC COOLING AND HEATING SYSTEM FOR WATER DISPENSER

Fabrication & Performance Analysis of Solar Water Heater Using Porous Medium & Agitator

Temperature Control of Heat Exchanger Using Fuzzy Logic Controller

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope

Faculty of Mechanical and Manufacturing Engineering Universiti Tun Hussein Onn Malaysia Pt. Raja, Batu Pahat, Johor, MALAYSIA

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Effect of Inclination Angle on Temperature Characteristics of Water in- Glass Evacuated Tubes

ISSN: [Agcaoili S. O., 7(3): March, 2018] Impact Factor: 5.164

Advantages and Disadvantages of Fire Modelling

American International Journal of Research in Science, Technology, Engineering & Mathematics

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 12, 2016 ISSN (online):

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Simulation of solar biomass hybrid dryer for drying cashew kernel

A Method of Heat Exchange Structure Optimization of the Cricoid Plastic Parts

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

CFD Analysis of Co-current Spray Dryer with Swirler at Air Inlet

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Analysis of CPU cooling using liquid with different type of heat sinks

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Transcription:

IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY Numerical Study on Solar Water Heater using CFD Analysis S.Eswaran *1,M.Chandru 2,M.Vairavel 3, R.Girimurugan 4 *1 Assistant professor, Department of Mechanical Engineering,Nandha Engineering College, Erode, India 2,3,4 Department of Mechanical Engineering, Nandha Engineering College, Anna University, India eswaranlecturer @gmail.com Abstract Solar water heater plays an important role in energy conservation. Because of its efficiency is comparatively more than the electrical energy conversion. It has become the well proven and established appliance for providing hot water requirements in lacks of families in India. Solar water heater is a very simple device and efficient way to absorb energy from the sun rays and use it. Therefore improvement in their operating condition & geometrical would definitely result in saving conventional fuel and cost. The objective of this study is to validate the mass flow rate of water inside the collector tube in an ado-ekidi natural circulation solar water heater system. The existing solar water heating systems the optimum mass flow rate is 0.1 kg / m2.the numerical analysis is carried out with CFD software and the results shows maximum mass flow rate inside the collector tube is 0.6 kg / m2,dynamic pressure of 4.30 105 Pa, flow velocity of 5.91 105 l/m2 & relative temperature of K. Keywords - Ado-Ekidi, CFD, mass flow rate, solar water heater, uniform flow. Introduction According to [1] a solar water heater (SWH) is an environmentally friendly device which absorbs free and renewable solar energy to reduce hot water, economically, reducing the use of conventional energy such as electricity by up to 80%. The solar hot water system produces hot water of 50 C to 70 C depending upon the season, location, solar intensity and number of solar collector panels. According to [2] solar water heaters are characterized by its thermal performance that depends on the transmittance, absorption and conduction of solar energy and the conductivity of the working fluid. According to [2] Solar water heating system with capacity of 50 to 100 liters per day has been installed in more than 30,000 homes throughout India the requirement of hot water per day for industrial and commercial sector is around 2, 40,000 liters. According to [2] the overall installed capacity of thermal collectors in India is capable of producing around 25 million liters of hot water per day at 60-70 C.In this study the already existing solar water heater panel model has reengineered and the new model has been created by using solid works software. Finally the whole assembly is imported to ANSYS FLUENT software and the mass flow rate inside the collector tube is calculated numerically by using it. Methodology Fig.1 Methodology of this study Methodologies of this study starts with the product selection (ado-ekidi solar water heater) and continue with problem identification it refers to the problem in mass flow rate inside the collector tube then collection of geometric data from an already existing solar water heater systems (adoekidi) and goes to creation of model using solid works software finally it ends with the CFD analysis to optimize the mass flow rate.

[Eswaran, 3(3): March, 2014] Existing Models solid works software to get the rate inside the collector tube. ISSN: 2277-9655 maximum mass flow Three Dimensional Model Fig.2 Flat plate solar collector with water pipes obtained from [3] Fig.3 Section at A-A obtained from [3] Fig.5 3D Model The above three dimensional model of solar water heater panel was created by solid works software. Over all dimensions of this panel is same as obtained from [3] Problem Identification The existing solar water heating systems the overall thermal performance reduces due to nonuniform flow in riser tubes. The overall thermal performance and efficiency is higher in variable header system due to uniform velocity. Optimization of Mass Flow Rate In this paper mass flow rate of water is optimized with respect to the total relative temperature at constant level ( K) by using ANSYS 14.5/CFD.Turbulance flow is selected for this optimization and K-ϵ solving equation is governed with the help of first order equation. Fig.4 Storage tank obtained from [3] CFD Analysis CFD analysis is carried out to optimize the mass flow rate of water inside the collector tube by means of the following steps. 1) Model creation We have already discussed about the three dimensional model creations. Created model is imported to ANSYS. 2) Mesh generation After importing the three dimensional model, the imported model is meshed with help of mesh options. Meshed model is shown in Fig.5 The above geometric models are obtained from [3] and the help of these geometric models the following models has been created by using

Fig.5 Mesh model 3) Applying boundary condition After mesh generation boundary conditions are given to this system. In this solar water heater there are two boundary conditions well defined. (Inlet & Outlet). Fig.7 Solution converged plot Results In table 1 computed result are tabulated at different mass flow rate. These values are obtained from ANSYS/CFD. Mass flow rate is optimized keep with the total temperature is constant Fig. 6 Boundary conditions Fig.8 Contour plot of dynamic pressure 4) Initialization The solver functioning areas its initialization values in constant mass flow rate 300 k,pressure distribution analysis insert 1bar,velocity magnitude 0.6m/s its initialized it. 5) Solution converged plot In solver stage optimum results computed with the solution converged plot. Fig.7 shows the solution converged plot which is taken from ANSYS/CFD. If optimum result reached at that time the above mentioned solution converged plot is appeared. Fig.8 Contour plot of flow velocity

[Eswaran, 3(3): March, 2014] ISSN: 2277-9655 2) Mass flow rate Vs Flow velocity Fig.9 Contour plot of total temperature Table 1 Effect of mass flow rate at different pressure and velocity Mass flow rate Dynamic Pressure Flow Velocity Total relative temperature (kg / m 2 ) (Pascal) ( l / m 2 ) (K) 0.3 0.4 0.5 0.6 0.7 1.15 10 5 6.45 10 5 2.04 10 5 1.83 10 3 2.99 10 5 2.28 10 3 4.30 10 5 5.91 10 5 6.28 10 5 3.20 10 5 1) Mass flow rate Vs Dynamic pressure Fig.10 Effect of mass flow rate at different dynamic pressure condition Fig.11 Effect of mass flow rate at different velocity level 3) Mass flow rate Vs Total temperature Fig.12 Effect of mass flow rate at total temperature Discussion 1) Mass flow rate Vs Dynamic pressure Fig.8 shows clearly increasing mass flow rate causes the increased value of dynamic pressure. Maximum dynamic pressure of 4.30 10 5 Pa has been obtained at the mass flow rate of 0.6 kg / m 2. 2) Mass flow rate Vs Flow velocity Fig.9 shows the effect of velocity of water flow at different mass flow rates. At the mass flow rate value of 0.3 kg / m 2 initial flow velocity of water is high then its velocity suddenly gets the drastic changes at mass flow rate of 0.4 & 0.5 kg / m 2 again the flow velocity suddenly increased at the mass flow rate of 0.6 kg / m 2.Finally the maximum velocity can be obtained at the mass flow rate of 0.6 kg / m 2. Summary In this study numerical analysis is carried out in reengineered Ado-Ekidi solar water heater by using CFD software. Results show that maximum mass flow rate is achieved more than experimental values. At the mass flow rate of 0.6

kg / m 2 maximum velocity has been obtained 5.91 10 5 l / m 2.The simulated velocity at the different mass flow rate compared and the results are discussed in detailed manner. Results proved that the maximum mass flow rate of these systems can be obtained up to 0.6 kg / m 2. References [1] G.N. Okonkwo and A.O.C. Nwokoye, Experimental Investigation and Performance Analysis of Thermosyphon Solar Water, Advances in Natural and Applied Sciences, 6 (2), 2012, 128-137. [2] Jaisankar Subramanian, Senthilkumar Tamilkozhndu, and Thulasi Selvam, Experimental Studies on Variable Header Solar Water Heating System: Proc. 2nd International Conference on Mechanical, Production and Automobile Engineering, Singapore, April 28-29, 2012,258-261. [3] Bucola.O.Bolaji, Flow design & collector performance of natural circulation solar water heater, Journal of Engineering & applied Sciences 1(1), 2006, 7-13.