1. Product description

e.control Function overview

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Product and Applications Description

UP 258E11 OPTISENS OFFICE

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Light & Motion. Sample applications 259. Ceiling sensors. Wall sensors. Outdoor sensors. Motion. Light &

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

B.E.G. LUXOMAT. Find the right detector.

Room Temperature Sensors

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

EBDSPIR-PRM-LV Product Guide

Detailed operating instructions

compact office 24V compact office 24V Lux

Data sheet. Function description. Benefits

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

Detailed operating instructions

Installation Guide. Ceiling PIR Detector (311) Features and Connections

compact office 24V compact office 24V Lux

Products. World Edition

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

, ,

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

02/11/2015

SMART BASIC BASIC-IR DAYLIGHT

FlowJam Bulk Flow Detection

2. Safety. 4. Function

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Integrated PIR detectors

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Product and Applications Description

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Busch-Watchdog presence. Overview and applications of presence detectors.

LPC3BSP65 & LPC3BDP65

Detector switch - Dual Tech SCS

FR-A180 FR-A360. Occupancy detector. Use

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

02/11/2015

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

Sensors and Detectors

Tri-level Control Sensor

Increased safety and reducing energy consumption with the motion control RPI 01

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

DALI MSensor 02 Multi-sensor for DALI system

LUXOMAT Application examples for electricians and planners

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

Passive infrared ceiling sensor

Operating instructions

SMARTER BUILDING. Busch-Presence detectors Energy saving the easy way

B.E.G. STILL EVEN BETTER!

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

Save energy. ARGUS presence detectors

Fire Damper Interface (24V)

PIR movement and presence detectors 10 A

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G.

LPCMPIRM65 & LPCMPIRDSI65

EBMHS (standard & slim-line PSU)

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

for relative humidity and temperature with calibration certificates

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Ceiling Microwave presence/absence detector 12-24V AC/DC

DALI MSensor 02 Multi-sensor for DALI system

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

Danfoss gas detection units

>WIRELESS> ALARM SYSTEM CR200

Fire Damper Interface (230V)

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

SCS motion sensors Surface/wall mounting - PIR

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Duct Air Quality Sensors

EasyAir SNH200. Sensors. Datasheet. EasyAir SNH200

B.E.G. LUXOMAT net. DALISYS Intelligent Lighting Control and more

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

Connections, displays and operating elements C D E G H. Installing the control unit

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

DETECTION AREA OA-FLEX AIR T. Active Infrared Sensor FLEX EYE A X B C D E F G. Emitting area

Danfoss gas detection units

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Plant growth chambers

ACS-30-EU-EMDR- 10-MOD

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

Retroreflective sensor with polarization filter

Transcription:

1. Product description Technical data The is a combination of occupancy sensor, two light sensors and infrared remote control receiver. An external temperature sensor can be connected. The sensitive 4-element-PIR sensor technology for occupancy detection guarantees reliable detection of occupants even when they are seated. Therefore lumina MS4 is ideally suited for occupancy related control functions within LON networks. The light sensors provide the basis of automatic lighting functions, such as constant light control or daylight switching. One light sensor measures the global room brightness whereas the second light sensor measures the brightness directly beneath the multisensor (spot measurement). Lights or blinds can be operated and scenes can be selected by means of the optional IR remote control. Additionally, a fan stage can be selected manually. Optional external temperature sensors for ceiling mounting or pendular temperature sensors can be connected. Alternatively presence detectors of type (order no.: 910 121 or 910 122) can be connected for expanding the presence detection range. The multisensor is available in two versions. The EB version is suitable for installation in suspended ceilings, ceiling sails or recessed junction boxes. The AP version allows surface mounting. For configuration purposes, comfortable LNS plug-ins are available. Version 1.04 Page 1 of 6 Dec 10, 2014

2. Mounting 2.1. Dimensions installation variant 2.2. Dimensions surface mount variant Version 1.04 Page 2 of 6 Dec 10, 2014

2.3. Connections Pin Meaning 1 24V ~/+ power supply 2 24V ~/- power supply 3 LON A 4 LON B 5 RTD (temperature sensor or presence detector ) 6 2.4. Note for connecting a temperature sensor When connecting an external temperature sensor, the installation distance between its cable and potential disturbing sources, e.g. mains supply lines, must be considered. Disturbances have an negative impact on the measuring accuracy. 2.5. Note for connecting a presence detector When connecting an external presence detector, the installation distance between its cable and potential disturbing sources, e.g. mains supply lines, must be considered. Disturbances can cause a faulty presence detection. It is allowed to connect only one presence detector directly to the multisensor (see connection scheme). 2.6. Connection example for The following scheme shows an installation of a multisensor and several presence detectors. Please note that only one presence detector may be connected directly to the multisensor. For more information please see the data sheet of the presence detctor (order no.: 910 121 / 910 122). Version 1.04 Page 3 of 6 Dec 10, 2014

Out In Out In 24V AC/DC LON LON RTD Out In Out In Out In /RC 2.7. LON Service-Pin After the multisensor is connected you can commission the device by entering the neuron id manually or receiving it in the LON tool. Sending the neuron id (service pin message) can be triggered with a standard infrared remote control. For that press any button for at least 3 seconds. Note: The remote control must use the popular NEC8 or NEC16 protocol. When the spega remote control dialog DRC-10 is used, sending the neuron id (service pin message) can be triggered by holding the temperature button and pressing the right menu button fan + for 2 seconds. Version 1.04 Page 4 of 6 Dec 10, 2014

3. Technical data Supply operating voltage, power 24V DC ±15%, ca. 30mA, max. 65mA, power 0.7W 24V AC ±15%, ca. 35mA, max. 80mA, power 1.2VA Network type of network Connections Network Power supply Temperature sensor Display LED FTT TP/FT-10 (78kbps) 6-pin detachable plug-in terminal connection for wire cross sections 0.2-1.5 mm² (solid and flex), two lines can be connected to each pin Multi color status led Sensors Occupancy Detection range, sitting Detection range, walking PIR Sensor 6m Ø, at 3m installation height 12m Ø, at 3m installation height Light 10 1000 Lux, Daylight and artificial light, V-Lambda-curve, 2 sensors for global and spot measurement Angular aperture global 180 Angular aperture spot 30 Switchable input for temperature sensor or presence detector Temperature -10-50 C, Accuracy approx. ± 0.5 C, for external 2-wire sensor of type PT1000, NI1000DIN or NI1000TK5000 Presence input for presence detector (order no.: 910 121 / 910 122) Remote control Infrared Range ca. 5m Housing Type of protection IP 20 (EN 60529) Dimensions installation variant 84 x 68 mm (Ø x Height) Fitting dimensions installation variant 68 x 40 mm (Ø x Depth) Dimensions surface mount variant 89 x 80 mm (Ø x Height) Ambient conditions Operating temperature Transport temperature Relative humidity Installation height CE-Conformity -25 C... +60 C -25 C... +60 C Max 93% (w/o condensation) up to 2000 m above sea level 2004/108/EC Electromagnetic Compatibility 2006/95/EC Low voltage directive 4. Products Version 1.04 Page 5 of 6 Dec 10, 2014

4.1. Order information Order number Description 911 113 W -EB, for suspended ceiling mounting, pure white 911 114 W -AP, for surface mounting, pure white 910 112 dialog DRC-10, infrared remote control with LC display, compatible with multisensors, /RC and clima DMS-20 5. Support The information given in this manual has been carefully collated. Should you have any further questions relating to this product, please contact: spega - Spelsberg Gebäudeautomation GmbH Zechenstr. 70 47443 Moers Germany Fon: +49 (2841) 88049-70 Fax: +49 (2841) 88049-49 Email: support@spega.com Version 1.04 Page 6 of 6 Dec 10, 2014