ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

Similar documents
O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

ONRB ONRB. Narrow Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

DELI MODELS: PMNUM, PMFNUM, PMN2UM, PMFN2UM INSTALLATION & OPERATION HANDBOOK. Featuring. Technology P902077H. Rev 4 1/07 COMPONENT

REAR LOAD DAIRY INSTALLATION & OPERATION HANDBOOK P056170D. Rev /10 COMPONENT

DELI MODEL: OSA & OSAG INSTALLATION & OPERATION HANDBOOK P052392H. Rev /09 COMPONENT

HANDBOOK O3EIF MEAT CASES INSTALLATION & OPERATION

RM with INNOVATOR Doors

OWIZ/OWIZV OWEZ/OWEZV

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

ORZ ORZH ONRZ. Table of Contents (ALSO INCLUDES ONRZH) Airflow & Defrost... 9 Fans & Case Cleaning Appendix... 11

3-DECK ISLAND PRODUCE INSTALLATION & OPERATION HANDBOOK. P053096D Rev. 9 11/10 COMPONENT

DELI MODELS: OSI, OWSI, OSIO & OWSIO INSTALLATION & OPERATION HANDBOOK. P052971K Rev. 8 7/04 COMPONENT

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

QLV5V-A - Glass Door Eliminator - Frozen Food. QIV5V-A - Glass Door Eliminator - Ice Cream. Applications: Specification Sheet 2 DR 3 DR 4 DR 5 DR

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

RL with INNOVATOR II No Heat Doors

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

MULTI-DECK FROZEN FOOD MERCHANDISER INSTALLATION & OPERATIONS MANUAL. Table of Contents

RLT with INNOVATOR Doors

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

Engineering Plan Views

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

ISLAND PRODUCE MODELS: OIP, OIPB, &OIPBB INSTALLATION & OPERATION HANDBOOK. P054956H Rev. 7 11/06 COMPONENT

QDV5V - 1 Door Standard (Gemtron)

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

RLNIE with INNOVATOR II

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

Installation & Service Manual

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

FG-L Technical Data Sheet

P/N _F NSF Certified June 2010

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

ORIZ ORIZH ONRIZ TABLE OF CONTENTS (ALSO INCLUDES ONRIZH) AIRFLOW & CASE TEMPERATURE... 9 FANS & CASE CLEANING APPENDIX...

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

PWEE Technical Data Sheet

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

Nosing Heater. Return Grill Heater

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

RMN with INNOVATOR Doors Technical Data Sheet

QC BEVERAGE/DAIRY/DELI

Installation & Service Manual

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

DAIRY/DELI PRODUCE C A S E S O5DMA INSTALLATION & OPERATION HANDBOOK. P056442G Rev /13

Case Study of Adding Glass Doors to Multi-Deck Meat Case

IMPORTANT KEEP IN STORE FOR FUTURE USE

CDC-R & CDC-D BAKERY MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents

MODEL RD-8 Self Contained MODEL RD-2

INSTALLATION & OPERATION MANUAL

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

INSTALLATION & OPERATION MANUAL QDV5V-A QDV5VT-A QIV5V-A, QIV5VT-A QLV5V-A, QLV5VT-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE

Low Flow Unit Coolers

Unico Training. Welcome to Unico!

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

INSTALLATION & OPERATION MANUAL QDV6V-A QIV6V-A, QLV6V-A REACH-IN DISPLAY CASES IMPORTANT KEEP IN STORE FOR FUTURE USE. Part No. 31E11043 Date: 1/5/15

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

NFW, NCW, NFWG, NCWG, NFWE, NCWE

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

Installation & Operation Manual. STRATUS Multi- Deck Display Case. Stratus Multi Deck Installation and Operations. Manual

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

INSTALLATION and OPERATION INSTRUCTIONS

S2SGC MEAT/SEAFOOD MULTI-DECK MERCHANDISER I N S TA L L AT I O N & O P E R AT I O N S M A N UA L. Table of Contents

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

Installation & Service Manual

COMMERCIAL AIR HANDLER

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

HVI-4-406R/HVI-4-408R

Bulletin , March Electric Hot Gas Bypass Valves

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

Energy Efficient. Flexible Design Options.

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

FOOD CABINETS. heated refrigerated ambient FOOD CABINETS

Transcription:

GENERAL NOTES "---" indicates that the feature is not an option with this case model and/or the data is not available at this time. SHIPPING WEIGHT --- Weight

ELECTRICAL DATA Fans Per High Effciency Fans 120 Volts Length Amps Watts 4' 1 0.16 11.0 6' 2 0.32 22.0 8' 2 0.32 22.0 12' 3 0.48 33.0 LIGHTING DATA Length Lights per row Lights Length Clearvoyant LED Lighting (Per Light Row) Standard Power (Cornice or Shelf) High Power (Cornice) 120 Volts 120 Volts Amps Watts Amps Watts 4' 1 4' 0.05 5.9 0.12 14.9 6' 2 3' 0.08 9.4 0.20 23.8 8' 2 4' 0.10 11.8 0.25 29.8 12' 3 4' 0.15 17.7 0.37 44.7 GUIDELINES AND CONTROL SETTINGS Front Sill BTUH/ft Superheat Set Evaporator Discharge Discharge Air Application Height Conventional Parallel Point @ Bulb ( F) ( F) Air ( F) Velocity (FPM) Dairy/Deli/Produce All 1175 1070 6-8 28 31 180 DEFROST CONTROLS Timed-Off Defrost Defrosts Per Day Fail-Safe 6 30 47 Listed BTUH/ft data represent unlighted shelves. For LED lighting, add 9 BTUH/ft per row of lighted shelving. BTUH load increases by 123 BTUH/ft when aftermarket merchandising accessories are utilized. Listed evaporator temperature represents unlighted shelves. For lighted shelves and/or aftermarket merchandising accessories, reduce the listed evaporator temperature by 2 F. Conventional Discharge Air Control - Recommended Settings: Cut-in Temp + Discharge Air + 2 F; Cut-Out Temp = Discharge Air - 2 F. Listed discharge air velocity represents the average velocity immediately after defrost. Tempertaure and defrost settings listed above are recommended start-up settings. Final operational settings may need to be adjusted for the store conditions in which the case operates. The recommended evaporator temperatures may need to be adjusted based on system setup, store conditions, etc. The minimum recommeded evaporator temperature is 4 F below the listed evaporator temperature.

SECOND NATURE DATA BTUH/FT (DR) GPM/ft Supply Fluid Discharge Air Model Coils Application Front Sill Type Conventional Parallel (DR) 1 Deli/Produce All Fronts 1015 930 0.26 20 31 1 Deli/Produce All Fronts 1015 930 0.67 25 31 SECOND NATURE DATA Coils Application Front Sill Type Defrost Timed-Off Defrost Fail Safe Warm Fluid Defrost Fail Safe Model 1 Deli/Produce All Fronts 6 60 47 26 49 1 Deli/Produce All Fronts 6 60 47 26 49

OPTIONS REAR SILL OPTIONS ORIGIN 2 FLAT FLAT TOP STANDARD REAR SILL 8 9/16" [21.7 cm] 12 1/2" REAR SILL 12 7/16" [31.7 cm] 16" REAR SILL (REAR DISCHARGE) 16 1/16" [40.7 cm] 27 1/16" [68.7 cm] 33 1/8" [84.2 cm] 32 15/16" [83.7 cm] 30" [76.2 cm] 28 1/8" [71.4 cm] 27 1/4" [69.3 cm] 27 1/8" [68.8 cm] 24 3/16" [61.4 cm] FLAT ANGLED TOP 22 5/16" [56.7 cm] 32 7/16" [82.3 cm] 30" [76.2 cm] 33" [83.8 cm] 33 1/8" [84.2 cm] 27 1/16" [68.7 cm] 27 1/4" [69.3 cm] 27 1/16" [68.8 cm] 24 1/8" [61.3 cm] 26 5/16" [66.9 cm] 27 1/16" [68.7 cm] 33 1/8" [84.1 cm] 32 15/16" [83.7 cm] 30" [76.2 cm] 33 7/16" [84.9 cm] 27 3/8" [69.5 cm] 33" [83.8 cm] 27" [68.6 cm] 27 1/4" [69.1 cm] 27 1/16" [68.8 cm] 24 1/8" [61.3 cm] Front and rear sill heights vary with base frame height.

12 3/8" [31.4 cm] 41 7/8" [106.3 cm] 66 5/8" [169.2 cm] CASE HEIGHT 37 1/2" [95.3 cm] INTERIOR HEIGHT 1 1 10" 10" LOAD LIMIT 12" 16" 24 7/8" [63.2 cm] COIL PLENUM THROAT DISPLAY STANDARD 60 3/4" [154.3 cm] CASE HEIGHT 12" 16" COIL PLENUM 11" [27.9 cm] 24 3/16" [61.5 cm] 25 1/8" [63.9 cm] 35 7/8" [91.1 cm] 22 7/8" [58.1 cm] 27 1/8" [68.9 cm] 5 1/8" [13.0 cm] 4" [10.2 cm] 29 3/8" [74.6 cm] 17" [43.2 cm] 21 1/4" [54.0 cm] 11" BASEFRAME 5" BASEFRAME ELECTRICAL JUNCTION BOX 2" MINIMUM AIR GAP 4" [10.2 cm] REAR REFRIGERATION LOCATED 18" [45.7 cm] ABOVE FINISH FLOOR 35 7/8" [91.1 cm] 29 3/8" [74.6 cm] 5" BASEFRAME 25 1/8" [63.8 cm] 11" BASEFRAME 26 7/8" [68.3 cm]** 5" BASEFRAME 11 1/4" [28.6 cm]** 11" BASEFRAME 23 1/8" [58.7 cm] 23 7/8" [60.6 cm] 1 1/2" PVC DRAIN CONNECTION REFRIGERATION 1 1/2" [3.8 cm] 8 5/8" [21.9 cm] 48" [121.9 cm] 72" [182.9 cm] 96" [243.8 cm] 144" [365.8 cm] * :STUB-UP AREA ** :RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS 1 :AVAILABLE SHELF SIZES: 10", 12", 14", 16", & 18" Ends add approximately 1" to case height, 1" to the front and 1/2" to the back Product on top shelf should be 3" below discharge.