Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

Similar documents
K 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection.

, ClO 2. K 100 Cl 2. , SCl 2 , O 2 , O 3 , H 2. O 2 K 100 W Cl 2. Manual

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Concise catalogue Water-Industry

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

Steam and Water Analysers

SECTION Free/Available Chlorine Analysis System

Process Alarm Module RTA 421

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Multi-Gas-Controller MGC2

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Turbimax CUE21 / CUE22

Speed and Frequency Seite 1 von 7

Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253

UDC 700 Universal Digital Controllers and Indicator Specifications

F4 Process Controller Installation and Operation Guide

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

WIO200 Water In Oil measuring instrument

Danfoss gas detection unit Type GD Heavy Duty

Two-Channel Gas Controller

WIO200 Water in oil sensor

Series Temperature Controller Instruction Sheet

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Static differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa

portable gas analyser

Danfoss gas detection units

SCHMIDT LED Measured Value Display MD Instructions for Use

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

portable gas analyser

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Oxygen (O2) Single-Point Gas Detection System

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

ST Wiring diagram. Product description. Standard temperature controller. Order number

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h

Mark 25 Ultrapure Water Conductivity Analyzer

Universal controller for panel mounting Models CS6S, CS6H, CS6L

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Toxic Gas Detection. Model F12. Toxic Gas Detection

Turbimax CUE21 / CUE22

WIO 200B and WIOI200B Water in oil sensor

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Installation Manual Tracker 221

I/A Series 716C 1/16 DIN Temperature Controller

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Poolcontrol DYNAMICS. Operating Instructions for users

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

CTT8 TEMPERATURE MONITOR DEVICE

Model D12-IR. Digital Gas Transmitter...

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Dissolved Oxygen Measurement liquisys S COM 223 / 253

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

1.7. Insulation fault evaluators EDS460/490 EDS461/491

MO n : 12JMC rév A

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

Danfoss gas detection units

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

ETO 2 - Controller for ice and snow melting

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

High Pressure Conductivity Monitor

Toroidal Conductivity Transmitters Series APT4000 Specifications

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Gas Controller Module GC-06

EasyTronic III MANUAL SERVICE

Operator's Manual Dielman Rock Island Industrial Dr. St. Louis, MO Tel:(314)

Level gauges Series LS Level indicator, switch and transmitter for liquids

Temperature Controllers

Table of Contents SECTION PAGE

MEAS CAL ALARM WASH CONF APT4000 TC

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

General Specifications

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation.

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

JW SERIES. Three Phase Thyristor Regulator PSE-351

Dew point set DS 400

PRODUCT CONFORMITY CERTIFICATE

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Call stations and extensions

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Product data sheet AIRWIN additional modules Accessories AIRWIN

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

Transcription:

Low maintenance by automatic sensor cleaning Pressure-proof up to 6 bar at 20 C Higher safety by integrated flow monitoring applications Drinking Water / Beverages Food Industry Disinfection Cooling And Boiler Feed Water description Ready for use and tested en bloc system to measure and control of Free Chlorine.

particular characteristics Inclusive instrument, single rod sensor, PMMA flow assembly (with sampling point, stop cocks for inlet and outlet, flow monitoring and temperature sensor), automatic sensor cleaning ASR and all necessary cables Plain text menu guidance Password function 2 limit values with delay, assigned to alarm relay 2 separate PI-controllers Dosage check Background illuminated two-line LC-Display for measured value and temperature Serial interface RS 485 Scaleable, glavanically isolated 0/4.. 20 ma output Display of relay status and error messages Invertible alarm output, permanent or pulse contact information The measuring system Krypton K is also available in 117 VAC and 24 VAC - without additional charge

technical data measuring parameter free Chlorine 0.00.. 4.00 mg/l Cl2 input characteristics temperature measuring range -30.. +140 C flow monitoring Flow monitor with integrated Pt 100 conditions max. pressure 6 bar (at 20 ), constant flow ~ 30..200 l/h, constant ambient temperature 0..50 C ph-range ph 6..8, constant min. conductivity >150 µs/cm output characteristics output signal 0/4.. 20 ma (scaleable, galvanically isolated) load max. 500 Ohm registration range adjustable within measuring range serial interface RS 485 baud rate 9600 data format 8 bit power supply line voltage power consumption ambient conditions ambient temperature relative humidity protection class 24 / 117 / 230 VAC, +6 / -10 %, 40.. 60 Hz 10 VA operation 0.. +50 C, storage -20.. +65 C exception sensors 0.. 30 C max. 90% rh at 40 C (non-condensing) wall mounted housing IP 65 controller control response on/off controller (adjustable hysteresis) P/PI controller (pulse-pause, pulse-frequency or continuous output) relays 2 relays each with potential-free NO contact, max. 250 V, 6 A, 550 VA 1 alarmrelay each with potential-free NO/CO contact, max. 250 V, 6 A, 550 VA onset delay digital input o.. 200 sec until controller active controller stop via external contact certificates and approvals CE-symbol Declaration of conformity: The product meets the requirements of the harmonized European standards. It thus complies with the legal requirements of the EC directives.

mechanical construction material dimensions sampling point water coupling board: PVC, assembly: PMMA, cocks: PP/PVC instruments: ABS, sensors: glass 700 x 395 mm 1/4'' female threat with stop cock inlet/ outlet: 1/2'' female threat (with stop cock) tube connection DN 6/8 order information name description article number measuring system (230 V), Free Chlorine 70005200K accessories sensors AuAu-600-OO-2-1-PG Pt-55-W AuAu-600-OO-2-1-PG is a single rod sensor with integrated counter electrode. This potentiostatic double gold sensor is in combination with our instruments suitable for measuring free Chlorine, Chlorine Dioxide and Ozone. The temperature sensor Pt 100 is a temperature probe which is based on the resistance change of platin at temperature influence. accessories CHECKIT Comparator EC-CIRC 15-700 The CHECKIT Comparator is a compact handy colorimeter unit which is suitable for both mobile and static analysis work. CHECKIT Comparator is a colorimetric rapid test for easy determination of Free Chlorine, Total Chlorine, Chlorine Dioxide or Ozone concentrations that can be used as an indication measurement for our amperometric measuring systems. Naturally, regarding resolution and accuracy, the rapid test does not come close to the Krypton systems, and it cannot replace a fotometric measurement. However, it provides a quick orientation and can therefore prove helpful during installation or routine comparison. The CHECKIT Comparator comes in a robust plastic casing with all necessary equipment. - spherical motor - 230V/50Hz, 25 W - circulation capacity: ca. 1m³/h - pressur: max. 10 bar (at 20 C) - temperature: max. 110 Cr - hydraulic connection: 1/2'' internal screw thread

PKV 30-DPS Converter for PROFIBUS-DP for max. 32 instruments of the K 100 oder dialog series. Converting of RS 485 to PROFIBUS-DP interface, instrument in a housing for installation on a top hat trail, dimension 105 X 105 x 80 mm (HxBxT), connectioncable inclusive S-341 data logger The bus data logger S-341 on the base of the RS-485 with Kuntze protocol reads, shows, and stores measuring data of up to 10 Kuntze instruments with up to 8 parameters each.