Understanding total measurement uncertainty in power meters and detectors

Similar documents
CALIBRATION HOW IT WORKS

CALIBRATION HOW IT WORKS

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Development of a variable output LED-365 irradiance standard

818 Series Low-Power Detectors

CALIBRATION HOW IT WORKS

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

An FT-NIR Primer. NR800-A-006

PM-200 Power Module Operating Instructions

Temperature dependent Components within the Pyroelectric Detector

Construction of a Calibration System for Power Responsivity of Optical detectors Using Different Laser Sources

POWER METER INSTRUCTION MANUAL

Laser Distance Sensor Type M Analog-Output

International comparison of validation methods for dust concentration measurement

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Publication American Institute of Physics. Reprinted with permission.

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

gray Laser Power Detectors For fast and accurate measurements

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Spectrum Detector, Inc.

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

CCD and CID solid-state detectors

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

LM-80V , h V LM-30V h V

Instruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

UV LED Measurement Status Update

CO2 Carbon Dioxide Sensor

Application Note. Application Note for BAYEX

Compression of Fins pipe and simple Heat pipe Using CFD

Laser Power and Energy Meters

Diode-Pumped Solid-State Blue Lasers

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Models S310 & S310D Laser Power and Energy Meters Setup and Operating Procedures

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Specifications Wavelength Range: 190 nm to 800 nm continuous

TESTS OF ADSIL COATING

Certificate: / 29 April 2014

APPLICATION NOTE. 1. Introduction Application Considerations

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Basics. Conversion principle and parameters of pyroelectric detectors

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

DAWN Electronics, Inc.

Model 835 Laser Pico-Watt Digital Power Meter

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

Measuring THz Radiation choose a Pyroelectric Detector or Golay Cell?

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

FIRERAY 5000 range USER GUIDE

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

Bunch Length Interferometer System

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Available online Journal of Scientific and Engineering Research, 2017, 4(10): Research Article

REVIEW OF ULTRAVIOLET AND HIGH POWER LASER MEASUREMENT STANDARDS AT NIST *

Measuring Couch Motion Accuracy with X-ray Beam Fluence

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Technical data sheet TDS0060

Measurement of Light. Photosensors

Lighting Measurement Solutions

Defense Technical Information Center Compilation Part Notice

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Temperature Data Logging

OFF-GRID COMMERCIAL DIRECT CURRENT GRID SYSTEM

Technical Information OUSAF44

NTC THERMISTOR SENSOR PERFORMANCE

Equipment specifications (D6)

SmartClass and SmartPocket Optical Handhelds. Portfolio of Optical Handhelds for Fiber Field Test

Polarized Light Scattering of Smoke Sources and Cooking Aerosols

Questionnaire on activities in radiometry and photometry. Reply from: Korea Research Institute of Standards and Science (KRISS)

PRODUCT CONFORMITY CERTIFICATE

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Environmental Radiation Monitoring System

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

Stand-off Detection of Trace Explosives by Infrared Photothermal Imaging. Trace Contamination

A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Infrared Moisture Balance (FD-800)

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Identify the key elements of the laser source, regardless of the type of measurement or sensor required;

Investigation of the Potential Use of Blue Light in Forward Scattering Optical Smoke Chambers to Detect all UL217 Fires in the New Standard

(PT-A1-AC ) Surface Mount Ambient Visible Light Sensor. Electronics Tech. Direct Electronics Industry Co., Ltd. Version: July 31, 2017

Temperature Sensors & Compression Seal Fittings

HYDROGEN DETECTION INSTRUMENTATION FOR THE SIAC HYDROGEN RECOMBINERS. Summary

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

COMPACTNESS 34.1 PERFORMANCE ANTICIPATION

OWNER S MANUAL ULTRAVIOLET SENSOR. Model SU-100

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Transcription:

Understanding total measurement uncertainty in power meters and detectors Jay Jeong, MKS Instruments. Inc. INTRODUCTION It is important that users of calibrated power meters and detectors understand and take into consideration the total uncertainty or error that exists in their measurements. Often, users assume that the rated calibration uncertainty of the Newport detector or power meter is the only error in their measurements, however, other factors also contribute to measurement uncertainty. Total measurement error is the sum of all possible sources of error, with detector or meter uncertainty being one of multiple sources of error in the measurement. While it is always a challenge to know exactly how much error the measurement system has, there are certain identifiable factors that should be taken into consideration when estimating total measurement uncertainty in detectors or power meters. These include (where applicable): Detector Calibration Uncertainty Sensor Uniformity Active Area of the Sensor Angular Dependence Linearity Temperature Meter Accuracy Meter Range This discussion will review the different contributors to measurement error and how they may be incorporated into an estimate of the total measurement uncertainty. Detector Calibration Uncertainty Newport s production detector calibration uncertainty is determined from calibration data correlated against a NIST (National Institute of Standards and Technology )-traceable Working Standard and the statistical figure of merit known as Gauge Repeatability and Reproducibility (GR&R) as applied to Newport s calibration system. Newport s Working Standard Detectors Light Source Entrance Optics Monochromator Exit Optics Detector PC Signal Readout Figure 1. Detector calibration system block diagram. [1] 1

Newport s Working Standard Detectors are calibrated against a NIST-Calibrated Reference Detector (the golden standard detector) every three months. NIST-Calibrated Reference Detectors are calibrated for Newport by the NIST and have tabulated uncertainty vs. wavelength. One or two of each type of Newport detector are sent to NIST for calibration and used thereafter as golden standards for calibrating Working Standard Detectors of that type. Newport s Working Standard Detectors are used for calibrating new production units and for re-calibrating customer s detectors. Following calibration with the Working Standard Detector, a report is provided with each new production or re-calibrated detector that contains a record of the measurement of spectral responsivity in amperes/watt (A/W) of incident radiation in 10 nm increments over the entire spectral range of the detector. Calibration Procedure Calibrations are performed in a stringently controlled environment using a broadband light source, a tunable monochromator, a working standard detector, a power meter and the detector undergoing calibration (Figure 1). When in use, the detector is positioned to ensure that the beam hits the center of the detector element with a pre-defined spot size. The monochromator-based calibration system typically measures only one power level during calibration, even though the level can vary slightly over time as the lamp in the light source ages. In the initial step of the calibration procedure, the appropriate Working Standard Detector is placed in the detector position of the calibration system shown in Figure 1. Using an automated program, the optical power of the broadband light source is measured with this detector at 10 nm increments. This calibrates the optical power output of the system to the accuracy of the NIST Calibrated Reference Detector plus any error introduced in transferring the NIST calibration to the Working Standard Detector. Following calibration of the system with the Working Standard Detector, the production or customer detector (the Detector Under Test or DUT) is put into the system and the same procedure followed as was used for the Working Standard Detector measurement, with the exception that the data collected from the DUT is the current (Amps) output by the device. Since the Working Standard Detector calibrated the system s optical power at 10 nm intervals, this data can be used to determine the DUT s responsivity as detector current vs. optical power (A/W). Gauge Repeatability and Reproducibility Gauge Repeatability and Reproducibility is a statistical method that distinguishes the variation in a measurement arising from the detector (repeatability) vs. the operators taking the measurement (reproducibility) when a measurement of the same parameter is performed under the same conditions of temperature, environment and operating procedure. Repeatability measures the variability in detector measurement of the same parameter under the same conditions over repeated measurements by the same operator. As such, it measures the inherent variability of the detector. Reproducibility measures the variability in a detector measurement that is due to the variations in the errors introduced by different operators of the calibration system. High GR&R numbers indicate instability in a measurement system while lower numbers indicate low measurement uncertainty. Newport s calibration facilities maintain the highest standards in their calibration systems, guaranteeing low GR&R numbers. Specified Accuracy Using NIST s and Newport s standard uncertainties and standard deviations from calibration measurements and the GR&R numbers calculations based on the calibration system and process, Newport specifies the accuracy of its detectors with a 95% confidence level. Calibration information, including responsivity data, calibration date, model number, and serial number, is saved in an EEPROM which is supplied with the detector. 2

When a detector is calibrated at Newport facilities, it does not include errors arising from factors outside of the detector calibration uncertainty. These include: Sensor Response Uniformity Active Area of the Sensor Angular Dependence of the Sensor Variations in Linearity Temperature Sensitivity Power Meter Accuracy Power Meter Range Calculation of the total error in detector measurements must include consideration of these factors. They are described in more detail in the following sections. Sensor Response Uniformity Detector calibration systems require a fixture to precisely and repeatably position new production detectors and customer units so that the light beam is always positioned at the exact center of the detector. The reason for this lies in the fact that the light sensing element in the detector exhibits a spatially non-uniform electrical response to light over its surface, by as much as ±2%. This nonuniformity is a consequence of unavoidable and small local variations that occur in all sensor fabrication processes; there is always some spatial nonuniformity of response in all kinds of detector, including photodiode, thermopile, and pyroelectric. The nature of the nonuniformity is different, depending on the materials and the processing techniques used to fabricate the sensor. Nonuniformity in a sensor is defined as the variation in responsivity (A/W) to a small diameter (~1 mm) laser beam over the surface of the sensor s active area. Since the granularity of the variations over a sensor surface can be quite small, of the order of microns rather than millimeters, measurement nonuniformity is inversely proportional to the spot size of the laser beam used to make the measurement. Newport specifies the nonuniformity of the sensor in its optical detector products. Not all photodiode manufacturers publish a specification for sensor response uniformity. Active Area of the Sensor Nonuniformity of the sensor response is impacted by the fact that the active area of the sensor may not be precisely defined, owing to wirebonding and other design features that exist on the sensor periphery. As well, the responsivity of the detector falls sharply near the edge of the photosensitive area. and some amount of current may be generated even when photons land outside of the designated active area of the sensor. Therefore, if the spot size of the input beam is close to the active diameter of the photodiode, users should always employ a detector aperture diameter that is smaller than the specified active diameter of the sensor. Angular Dependence of the Sensor The responsivity of the sensor in a detector exhibits an angular dependence. This is due to the presence of protective coatings on the surface of the sensor, especially photodiodes. The latter type of sensor is typically coated with a protective clear epoxy and an anti-reflective coating. The stacked thin films of these materials exhibit a strong angular dependence for the amount of light that is reflected from the surface and from the interface between the films. During calibration, the sensor housing is precisely positioned so that the light beam coming from the monochromator impinges on the sensor 3

surface at a 90 to that surface (Figure 1). (Note that photodiodes are normally positioned at a slight angle to the front face side of the detector housing, to avoid backreflection of the beam into the laser cavity. This configuration results in minimum reflection of the incoming light from the surface and interface between the protective and anti-reflective films. As the angle of the incoming light beam departs from 90, more and more light is reflected from the surface and interface, reducing the measured power of the optical signal. Many detectors with photodiode sensors employ a neutral density (ND) filter to attenuate the incoming light beam and avoid saturation of the photodiode sensor. ND filters exhibit issues with angular dependence of the degree of light reflected from the surface of the filter material as are seen with the coatings on sensors. For these reasons, the user must always take care to position the sensor surface at an angle as close as possible to normal to the incoming light beam. Variations in Linearity Optical sensors have a defined range in which the electrical output (amps or volts) responds linearly to the optical power input (watts). Beyond this range, the response becomes increasingly nonlinear as the sensor approaches saturation. The user must carefully select the detector type for a given application in order to ensure that the detector will not saturate within the range of power levels expected for the measurement. As well, the user must be aware of the fact that, even within the linear range, every detector exhibits a characteristic error in its responsivity. The calibration procedure measures the responsivity at only one current level at each tested wavelength. Typically, each detector type will have specifications for the error in the linear range that the user must take into account when calculating total error. Temperature Sensitivity Temperature affects measurement accuracy for all types of optical sensors. Photodiode sensors exhibit a wavelengthdependent change in optical responsivity with temperature. Figure 2 shows the variation of the temperature coefficient of sensitivity for different semiconductor materials used in optical sensors. The chart illustrates how this change varies with the wavelength of the laser light impinging on an optical sensor fabricated with the different semiconducting materials. These materials exhibit different maximum wavelengths below which the optical responsivity does not change with changes in temperature. As the laser wavelength approaches and passes through this maximum, the output of the sensor becomes increasingly sensitive to the temperature of the photodiode sensor due to the inherent bandgap structure. Most of the Newport s 918D series detectors employ an internal temperature sensor. Advanced power meter models such as 841-PE-USB, 1919-R, and 1936-R/2936-R can read the temperature and compensate for the responsivity differences that arise from the difference between the temperature during calibration and at measurement by the user. These optical power meters are equipped with a proprietary responsivity calculation algorithm. If a detector without a temperature sensor is used with lasers operating at wavelengths beyond the wavelength maximum, they MUST be used only under constant temperature conditions. Any comparisons of data from different photodiode sensors used for measurements of similar lasers operating beyond the wavelength maximum are only valid if the data is collected at exactly equal temperatures. Otherwise, photodiode sensors should not be employed with lasers operating at wavelengths near or beyond the semiconductor material maximum. Thermal optical sensor measurements can be affected by variations in ambient temperature. In thermal sensors, the heat flow between the center of a thermal disk, where the laser beam impinges, and the cooler periphery of the disk generates a voltage proportional to the optical power of the laser beam being measured. A thermal sensor s output is independent of ambient temperature, provided that the sensor is in equilibrium with its surroundings. However, if the temperature of the 4

sensor differs from ambient, that difference will manifest as an offset on the meter readings. For example, a thermal sensor moved from a hot car into an air-conditioned office will indicate a negative offset on any measured reading until the sensor is at the same temperature as the ambient environment. Similarly, radiating high temperature sources (e.g. the laser system) will be detected by the sensor, producing a positive offset in measured readings. In general, a user should measure the power on the sensor before applying the laser beam to make sure no additional sources are influencing the power. Figure 1. The change in optical responsivity for different photodiode sensor materials Power Meter Accuracy A power meter is essentially a highly sensitive ammeter or voltmeter and different power meters have different characteristic accuracy specifications. The optical sensor in a detector generates either a current or a voltage output signal and the inherent error in the power meter that reads this signal must be considered for total error calculations. Power Meter Range The power meter accuracy specification is only valid so long as the measurement is performed within the correct power range. Each power meter has several ranges within which the amplified signal is properly matched to the meter circuitry. Once the optimal range has been determined, it is normally recommended that the user stay in that range to obtain the most reliable data. The Auto range setting on a power meter is a convenient feature that can ensure that the meter is set to the proper range for the power measurement no matter what the laser power level is. Since it normally takes a finite amount of time for a range change, care should be taken that measurements are not made in the transient period to avoid inaccurate or invalid measurements. 5

Calculation of the Total Error When dealing with simultaneous sources of error in a measurement, the RMS noise is calculated as the square root of the sum of the squared errors. For example, consider a measurement that is carried out under conditions that are very close to the maximum power rating of the detector with the physical set-up such that the measurement is made slightly off-center on the sensor (but still within 50%). In this case, the total error is a combination of all the known error sources. For example: ±3% due to the basic calibration uncertainty in the detector (95% confidence level), ±1% additional error due to the nonlinearity of measurements at high power, ±2% additional error due to the laser beam not being centered on the sensor. Any other known sources or errors The total error in this case is calculated as at least ±3.7 %: Total Error = ± 3 2 +1 2 +2 2 = ± 14 = ±3.7 % It is noteworthy that, even in a case with multiple sources of error, the total error is often not a great deal more than the basic calibration uncertainty. There can be other unknown or unaccounted sources of error, but in most cases their contributions are insignificant. However, once a previously unaccounted error source, such as a fluctuation of the input laser beam, proves to be significant, its contribution to the total amount of error must be estimated and added in the calculation. Conclusion The total uncertainty of a measurement must always be considered when using calibrated power meters and detectors in optical measurement systems. Calculations of the total uncertainty of a measurement are not limited to just the inherent calibration error of the detector; total uncertainty must include estimates for all other known sources of error in the measurement system. Detector calibration errors do not include sources of error in the measurement system such as the temperature, active area and angular dependence of the sensor responsivity, nonuniformity of responsivity over the sensor area, variations in linearity of the sensor response at high optical power, and the range and accuracy of power meters. Calculation of the total error in optical measurements must consider all these factors plus any other known sources of error in the system. 6