SERVICE MANUAL. Split Air Conditioner VERITAS INVERTER Series

Similar documents
SERVICE MANUAL. Split Air Conditioner VERITAS INVERTER Series CH-S18FTXQ (WI-FI)

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

ALICE HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL


SERVICE MANUAL. Split Air Conditioner Arctic Series mod. A

Split Air Conditioner

Change for Life. Service Manual

Owner s Manual. Wall Mounted Unit. Models LIMI-12 / LIMO-12 LIMI-18 / LIMO-18 LIMI-24 / LIMO-24

Thank you for selecting LENNOX air conditioners.

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

Split Air Conditioner. Model: GSA609AE GSA609AC GSA612AE GSA612AC GSA618AE GSA618AC GSA624AE GSA624AC

AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT

GWH09QB-K3DNC6D GWH12QB-K3DNA1D GWH12QB-K3DNA2D GWH12QB-K3DNA3D GWH12QB-K3DNA6D GWH12QB-K3DNB2D GWH12QB-K3DNB4D GWH12QB-K3DNB6D GWH12QB-K3DNB8D

Split Air Conditioner

OWNER S MANUAL. Split Air Conditioner IAPH301A / OAPH301A IAPH361A / OAPH361A

OWNER S MANUAL. Split Air Conditioner AIR-MASTER Series MODELS: CH-S07RX4 CH-S09RX4 CH-S12RX4 CH-S18RX4 CH-S24RX4

Split Air Conditioner

AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

Split Air Conditioner

Split Air Conditioner

Room Air Conditioners

Split Air Conditioner

SERVICE MANUAL. Room Air Conditioner Split Wall-Mounted Type. Models:

Change for Life. Service Manual GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI

Change for life. Service Manual GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

Change for Life. Service Manual. Models: MULTI18HP230V1BO MULTI24HP230V1BO GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI

Service Manual. Models: MWM09Y1J/MRM09Y1J MWM12Y1J/MRM12Y1J (Refrigerant R410A)

OWNER S MANUAL. Split Air Conditioner Arctic Series. For proper operation, please read and keep this manual carefully.

Split Air Conditioner

Service Manual & Installation Manual

Troubleshooting & Reference

DESHUMIDIFIER MH-V5 Service manual

Lillehammer Service Manual Indoor

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

Part Ⅰ : Technical Information

OWNER S MANUAL. Heat Pump Air To Air Split Air Conditioner ICY II Series

Service Manual. Model: ACZEM4C4R18/ACZCI4C4R18 ACZEM4H4R18/ACZCI4H4R18 ACZEM4C4R24/ACZCI4C4R24 ACZEM4H4R24/ACZCI4H4R24 (Refrigerant:R410A)

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

Split Air Conditioner

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Split Air Conditioner

Split Air Conditioner WAM24MH21S/I. Thank you for choosing our product. For proper operation, please read and keep this manual carefully.

INSTALLATION INSTRUCTIONS R 410A

Service Manual & Installation Manual

INVERTER SPLIT - TYPE

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB

Change for Life. Service Manual. Models: CH-S24FTXE Wi-Fi (Refrigerant R410A)

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

Split Air Conditioner. Thank you for choosing our product. For proper operation, please read and keep this manual carefully.

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

ROOM AIR CONDITIONER INSTALLATION MANUAL

Condensing Unit Service Manual (T1/R410a/60Hz)

Split Air Conditioner

Installation Instructions

Split Air Conditioner

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Service Manual. Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB

MAFX/GRFX DC INVERTER

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Choosing the installation site. Installation. 07 Choosing the installation site

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

PORTABLE AIR CONDITIONER

Split Air Conditioner. Thank you for choosing our product. For proper operation, please read and keep this manual carefully.

ΚΛΙΜΑΤΙΣΤΙΚΟ ΤΟΙΧΟΥ ΤΥΠΟΥ INVERTER WALL MOUNTED AIR CONDITIONER INVERTER TYPE

Service Manual. Air Conditional

Service Manual "X" SERIES 18K - 24K - 208/230V INVERTER-DRIVEN AIR CONDITIONING UNITS PLEASE READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS

Installation Instructions

Service Manual "P" SERIES 30K - 36K 220V INVERTER-DRIVEN AIR CONDITIONING UNITS IMPORTANT:

Room Air Conditioner Service and Parts Manual

HEAT PUMP INSTALLATION MANUAL

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

Service Manual A16EW4H4R09 A16EW4H4R12 A16EW4H4R18

DAIKIN AIR CONDITIONER

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL

TECHNICAL DATA & SERVICE MANUAL

Installation Instructions

HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

YC ON-OFF SERIES. Service Manual

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

Please read this manual carefully before installation and keep it for future reference. CONTENTS. Installation Manual. DIY Series

FAN COILS wall mounted

Split Air Conditioner

Air Conditioner. user installation & manual manual. imagine the possibilities

Owner s Manual Super-Slim Four-Way Cassette

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

Owner s Manual Window Air Conditioner

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

MODELS INSTALLATION INSTRUCTIONS AND HOMEOWNER S MANUAL COND COND INSTALLER / SERVICE TECHNICIAN: HOMEOWNER: CAUTION

WALL MOUNT DUCTLESS AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

Transcription:

E SERVICE MAUAL Split Air Conditioner VERITAS IVERTER Series MODEL: CH-S09FTXQ (WI-FI) For proper operation, please read and keep this manual carefully. Designed by Cooper&Hunter International Corporation, Oregon, USA www.cooperandhunter.com

Part Ⅰ : Technical Information 1. Summary Indoor Unit Outdoor Unit Remote Controller

2. Specifications 2.1 Specification Sheet Model CH-S09FTXQ (WI-FI) Product Code CB470001002 Rated Voltage V~ 220-240 Power Rated Frequency Hz 50 Supply Phases 1 Power Supply Mode Outdoor Cooling Capacity W 2600 Heating Capacity W 2800 Cooling Power Input W 718 Heating Power Input W 733 Cooling Current Input A 3.60 Heating Current Input A 3.50 Rated Input W 1400 Rated Current A 6.70 Air Flow Volume(SH/H/M/L/SL) m 3 /h 480/370/320/210/- Dehumidifying Volume L/h 0.80 EER W/W 3.62 COP W/W 3.82 SEER 6.10 SCOP 4.10 Application Area m 2 12-18 Indoor Unit Model CH-S09FTXQ (WI-FI) Indoor Unit Product Code CB47001000 Indoor Unit Fan Type Cross-flow Fan Diameter Length(DXL) mm Ф98X580 Cooling Speed(SH/H/M/L/SL) r/min 1300/1200/1050/800/- Heating Speed(SH/H/M/L/SL) r/min 1300/1200/1050/900/- Fan Motor Power Output W 20 Fan Motor RLA A 0.21 Fan Motor Capacitor μf 1 Evaporator Form Aluminum Fin-copper Tube Evaporator Pipe Diameter mm Ф5 Evaporator Row-fin Gap mm 2-1.4 Evaporator Coil Length(LXDXW) mm 584X22.8X266.7 Swing Motor Model MP24AA Swing Motor Power Output W 1.5 Fuse Current A 3.15 Sound Pressure Level(SH/H/M/L/SL) db (A) 38/35/26/23/- Sound Power Level(SH/H/M/L/SL) db (A) 50/47/44/39/- Dimension(WXHXD) mm 790X275X200 Dimension of Carton Box(LXWXH) mm 850X339X262 Dimension of Package(LXWXH) mm 852X355X273 et Weight kg 9 Gross Weight kg 11

Outdoor Unit Model of Outdoor Unit Product Code of Outdoor Unit Compressor Manufacturer/Trademark Compressor Model Compressor Oil Compressor Type CH-S09FTXQ (WI-FI) CB427W04802 ZHUHAI LADA COMPRESSOR CO., LTD QXA-A091zE190A 68EP Rotary L.R.A. A 16.5 Compressor RLA A 4.5 Compressor Power Input W 942 Overload Protector Throttling Method Operation temp Ambient temp (cooling) Ambient temp (heating) Condenser Form 1T11L-6233 Capillary o C 16~30 o C -24~48 o C -15~24 Aluminum Fin-copper Tube Pipe Diameter mm Ф7 Rows-fin Gap mm 1-1.4 Coil Length (LXDXW) mm 710X19.05X506 Fan Motor Speed rpm 900 Output of Fan Motor W 30 Fan Motor RLA A 0.4 Fan Motor Capacitor μf / Air Flow Volume of Outdoor Unit m 3 /h 1600 Fan Type Axial-flow Fan Diameter mm Ф400 Defrosting Method Climate Type Isolation Moisture Protection Automatic Defrosting T1 I IPX4 Permissible Excessive Operating Pressure for the Discharge Side MPa 4.3 Permissible Excessive Operating Pressure for the Suction Side MPa 2.5 Sound Pressure Level (H/M/L) db (A) 49/-/- Sound Power Level (H/M/L) db (A) 60/-/- Dimension (WXHXD) mm 782X540X320 Dimension of Carton Box (LXWXH) mm 820X355X580 Dimension of Package (LXWXH) mm 823X358X595 et Weight kg 25.5 Gross Weight kg 28 Refrigerant R410A Refrigerant Charge kg 0.70 Length m 5 Gas Additional Charge g/m 20 Outer Diameter Liquid Pipe mm Ф6 Connection Outer Diameter Gas Pipe mm Ф9.52 Pipe Max Distance Height m 10 Max Distance Length m 15 ote: The connection pipe applies metric diameter. The above data is subject to change without tice; please refer to the nameplate of the unit.

2.2 Operation Characteristic Curve Cooling Heating Current (A) 11 10 Conditions 220V 10 220V 9 Indoor:DB27 C/WB19 C 9 8 Outdoor:DB35 C/WB24 C 8 Indoor air flow:super High 7 Pipe length:5m 7 230V 6 6 5 230V 5 240V 4 4 Conditions 3 3 Indoor:DB20 C/WB15 C 2 240V 2 Outdoor:DB7 C/WB6 C Indoor air flow:super High 1 1 Pipe length:5m 0 0 0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90 100 110120 Compressor speed (rps) Compressor speed (rps) Current (A) 11 2.3 Capacity Variation Ratio According to Temperature Heating operation ambient temperature range is -15ºC~24ºC Cooling Heating Capacity ratio(%) 130 120 110 100 90 80 70 Condition Indoor:DB27 C WB19 C 60 Indoor air flow: High Pipe length:5m 50 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 Outdoor temp. ( C) Capacity ratio(%) 110 100 90 80 70 Conditions Indoor:DB20 C 60 Indoor air flow:super High Pipe length:5m 50 15 10 5 0 5 7 10 40 Outdoor temp.( C)

Heating operation ambient temperature range is -22ºC~24ºC Cooling Heating Capacity ratio (%) 105 100 95 90 85 80 75 70 65 Conditions Indoor:DB27 C/WB19 C 60 Indoor air flow:super High 55 Pipe length: 5m 50 32 33 34 35 36 37 38 39 40 41 42 43 Outdoor temp.( C) 2.4 Cooling and Heating Data Sheet in Rated Frequency Cooling: Rated cooling condition( o C) (DB/WB) Model Pressure of gas pipe connecting indoor and outdoor unit 120 110 100 90 80 70 60 50 40 30 Conditions Indoor:DB20 C/WB15 C Indoor air flow:super High Pipe length: 5m -22-15 -10-5 0 7 15 20 24 Inlet and outlet pipe temperature of heat exchanger Indoor Outdoor P (MPa) T1 ( o C) T2 ( o C) Fan speed of indoor unit Outdoor temp.( o C) Fan speed of outdoor unit Compressor frequency (Hz) 27/19 35/24 09K 0.8 ~ 1.1 11 to 14 38 to 41 Super High High 52 Heating: Rated heating condition( o C) (DB/WB) Model Pressure of gas pipe connecting indoor and outdoor unit Inlet and outlet pipe temperature of heat exchanger Fan speed of indoor unit Fan speed of outdoor unit Compressor frequency (Hz) Indoor Outdoor P (MPa) T1 ( C) T2 ( C) 20/15 7/6 09K 2.8 ~ 3.2 38 to 41 2 to 5 Super High High 65 Instruction: T1: Inlet and outlet pipe temperature of evaporator T2: Inlet and outlet pipe temperature of condenser P: Pressure at the side of big valve Connection pipe length: 5 m.

2.5 oise Curve 70 Outdoor side ise 50 Indoor side ise 60 oise/db(a) 40 30 oise/db(a) 50 40 30 20 Low Middle High Supper High 20 0 20 40 60 80 100 Indoor fan motor rotating speed Compressor frequency/hz

3. Outline Dimension Diagram 3.1 Indoor Unit 168.5 462 159.5 09 Φ55 Φ55 54 54 150 90 104 685 181 Unit:mm Models W H D 09K 790 275 200 Φ55 Φ55 18/24K 38 38 190 140

286 3.2 Outdoor Unit 712 257 540 782 320 510 Unit:mm

4. Refrigerant System Diagram Cooling and heating model Indoor unit Outdoor unit Gas pipe side Valve 4-Way valve Discharge Heat exchanger (evaporator) Liquid pipe side Valve Suction Accumlator Compressor Strainer Capillary Strainer Heat exchanger (condenser) COOLIG HEATIG Connection pipe specification: Liquid pipe:1/4" (6mm) Gas pipe:3/8" (9.52mm) 09/12/18K Gas pipe:5/8" (16mm) 24K

5. Electrical Part 5.1 Wiring Diagram Instruction Symbol Symbol Color Symbol Symbol Color Symbol ame WH White G Green CAP Jumper cap E ellow B Brown COMP Compressor RD Red BU Blue Grounding wire EG ellow/green BK Black / / VT Violet OG Orange / / ote: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model. Indoor Unit 6363222005

Outdoor Unit 63610000309

5.2 PCB Printed Diagram Indoor Unit Top view 1 2 3 4 5 6 7 14 13 12 8 9 10 o ame 1 eutral wire terminal 2 Interface of health function neutral wire 3 Motor needle stand 4 Interface of health function live wire 5 Auto button 6 Up&down swing motor 7 Interface of PG feedback 8 WIFI 9 Temperature sensor 10 Terminal for display board connection 11 Jump Terminal with outdoor unit communication 12 wire 13 Live wire terminal 14 Fuse Bottom view 11

Outdoor Unit Top view 3 4 5 2 6 7 8 o. ame 1 Interface of compressor wire 2 Interface of reactor Terminal of power supply live wire 3 terminal 4 Interface of 4-way valve 5 Terminal of power supply neutral wire 6 Grounding wire 7 Live wire 8 eutral wire 9 Communication wire 10 Overload interface of compressor 11 Interface of temperature sensor 1 9 Bottom view 11 10

Part Ⅱ : Installation and Maintenance 7. otes for Installation and Maintenance Safety Precautions: Important! Please read the safety precautions carefully before installation and maintenance. The following contents are very important for installation and maintenance. Please follow the instructions below. The installation or maintenance must accord with the instructions. Comply with all national electrical codes and local electrical codes. Pay attention to the warnings and cautions in this manual. All installation and maintenance shall be performed by distributor or qualified person. All electric work must be performed by a licensed technician according to local regulations and the instructions given in this manual. Be caution during installation and maintenance. Prohibit incorrect operation to prevent electric shock, casualty and other accidents. Warnings Electrical Safety Precautions: 1. Cut off the power supply of air conditioner before checking and maintenance. 2. The air condition must apply specialized circuit and prohibit share the same circuit with other appliances. 3. The air conditioner should be installed in suitable location and ensure the power plug is touchable. 4. Make sure each wiring terminal is connected firmly during installation and maintenance. 5. Have the unit adequately grounded. The grounding wire cant be used for other purposes. 6. Must apply protective accessories such as protective boards, cable-cross loop and wire clip. 7. The live wire, neutral wire and grounding wire of power supply must be corresponding to the live wire, neutral wire and grounding wire of the air conditioner. 8. The power cord and power connection wires cant be pressed by hard objects. 9. If power cord or connection wire is broken, it must be replaced by a qualified person. 10. If the power cord or connection wire is t long eugh, please get the specialized power cord or connection wire from the manufacture or distributor. Prohibit prolong the wire by yourself. 11. For the air conditioner without plug, an air switch must be installed in the circuit. The air switch should be all-pole parting and the contact parting distance should be more than 3mm. 12. Make sure all wires and pipes are connected properly and the valves are opened before energizing. 13. Check if there is electric leakage on the unit body. If, please eliminate the electric leakage. 14. Replace the fuse with a new one of the same specification if it is burnt down; dont replace it with a cooper wire or conducting wire. 15. If the unit is to be installed in a humid place, the circuit breaker must be installed. Installation Safety Precautions: 1. Select the installation location according to the requirement of this manual.(see the requirements in installation part) 2. Handle unit transportation with care; the unit should t be carried by only one person if it is more than 20kg. 3. When installing the indoor unit and outdoor unit, a sufficient fixing bolt must be installed; make sure the installation support is firm. 4. Ware safety belt if the height of working is above 2m. 5. Use equipped components or appointed components during installation. 6. Make sure foreign objects are left in the unit after finishing installation. Refrigerant Safety Precautions: 1. Avoid contact between refrigerant and fire as it generates poisous gas; Prohibit prolong the connection pipe by welding. 2. Apply specified refrigerant only. ever have it mixed with any other refrigerant. ever have air remain in the refrigerant line as it may lead to rupture or other hazards. 3. Make sure refrigerant gas is leaking out when installation is completed. 4. If there is refrigerant leakage, please take sufficient measure to minimize the density of refrigerant. 5. ever touch the refrigerant piping or compressor without wearing glove to avoid scald or frostbite. Improper installation may lead to fire hazard, explosion, electric shock or injury.

To ensure safety, please be mindful of the following precautions. When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury. When installing or moving this unit, do t charge the refrigerant which is t comply with that on the nameplate or unqualified refrigerant.otherwise, it may cause abrmal operation, wrong action, mechanical malfunction or even series safety accident. When refrigerant needs to be recovered during relocating or repairing the unit, be sure that the unit is running in cooling mode. Then, fully close the valve at high pressure side (liquid valve).about 30-40 seconds later, fully close the valve at low pressure side (gas valve), immediately stop the unit and disconnect power. Please te that the time for refrigerant recovery should t exceed 1 minute. If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury. During refrigerant recovery, make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe. If compressor starts running when stop valve is open and connection pipe is t yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury. When installing the unit, make sure that connection pipe is securely connected before the compressor starts running. If compressor starts running when stop valve is open and connection pipe is t yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury. Prohibit installing the unit at the place where there may be leaked corrosive gas or flammable gas. If there leaked gas around the unit, it may cause explosion and other accidents. Do t use extension cords for electrical connections. If the electric wire is t long eugh, please contact a local service center authorized and ask for a proper electric wire. Poor connections may lead to electric shock or fire. Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the wires so that their terminals receive external stresses. Electric wires with insufficient capacity, wrong wire connections and insecure wire terminals may cause electric shock or fire.

Main Tools for Installation and Maintenance 1. Level meter, measuring tape 2. Screw driver 3. Impact drill, drill head, electric drill 4. Electroprobe 5. Universal meter 6. Torque wrench, open-end wrench, inner hexagon spanner 7. Electronic leakage detector 8. Vacuum pump 9. Pressure meter 10. Pipe pliers, pipe cutter 11. Pipe expander, pipe bender 12. Soldering appliance, refrigerant container R410A

8. Installation 8.1 Installation Dimension Diagram At least 250cm At least 15cm At least 300cm Space to the obstruction At least 50cm Space to the floor Space to the ceiling Space to the wall At least 15cm At least 15cm Space to the wall Space to the obstruction Space to the obstruction At least 30cm At least 30cm Drainage pipe Space to the wall Space to the obstruction At least 200cm At least 50cm Space to the obstruction

Installation procedures Start installation Preparation before installation Read the requirements for electric connection select installation location Prepare tools Select indoor unit installation location Select outdoor unit installation location Install wall-mounting frame, drill wall holes Connect pipes of indoor unit and drainage pipe Connect wires of indoor unit Install the support of outdoor unit (select it according to the actual situation) Fix outdoor unit Install drainage joint of outdoor unit (only for cooling and heating unit) Bind up pipes and hang the indoor unit Make the bound pipes pass through the wall hole and then connect outdoor unit Connect pipes of outdoor unit Connect wires of outdoor unit eaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installation ote: this flow is only for reference; please find the more detailed installation steps in this section.

8.2 Installation Parts-checking o. ame o. ame 1 Indoor unit 8 Sealing gum 2 Outdoor unit 9 Wrapping tape 3 Connection pipe 10 Support of outdoor unit 4 Drainage pipe 11 Fixing screw 5 Wall-mounting Drainage plug(cooling 12 frame and heating unit) 6 Connecting Owners manual, 13 cable(power cord) remote controller 7 Wall pipe ote: 1.Please contact the local agent for installation. 2.Dont use unqualified power cord. 8.3 Selection of Installation Location 1. Basic Requirement: Installing the unit in the following places may cause malfunction. If it is unavoidable, please consult the local dealer: (1) The place with strong heat sources, vapors, flammable or explosive gas, or volatile objects spread in the air. (2) The place with high-frequency devices (such as welding machine, medical equipment). (3) The place near coast area. (4) The place with oil or fumes in the air. (5) The place with sulfureted gas. (6) Other places with special circumstances. 2. Indoor Unit: (1) There should be obstruction near air inlet and air outlet. (2) Select a location where the condensation water can be dispersed easily and wont affect other people. (3) Select a location which is convenient to connect the outdoor unit and near the power socket. (4) Select a location which is out of reach for children. (5) The location should be able to withstand the weight of indoor unit and wont increase ise and vibration. (6) The appliance must be installed 2.5m above floor. (7) Dont install the indoor unit right above the electric appliance. (8) The appliance shall t be installed in the laundry. 3. Outdoor Unit: (1) Select a location where the ise and outflow air emitted by the outdoor unit will t affect neighborhood. (2) The location should be well ventilated and dry, in which the outdoor unit wont be exposed directly to sunlight or strong wind. (3) The location should be able to withstand the weight of outdoor unit. (4) Make sure that the installation follows the requirement of installation dimension diagram. (5) Select a location which is out of reach for children and far away from animals or plants.if it is unavoidable, please add fence for safety purpose. 8.4 Requirements for electric connection 1. Safety Precaution (1) Must follow the electric safety regulations when installing the unit. (2) According to the local safety regulations, use qualified power supply circuit and air switch. (3) Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring may result in electric shock,fire hazard or malfunction. Please install proper power supply cables before using the air conditioner. (4) Properly connect the live wire, neutral wire and grounding wire of power socket. (5) Be sure to cut off the power supply before proceeding any work related to electricity and safety. (6) Do t put through the power before finishing installation. (7) For appliances with type attachment,the instructions shall contain the substance of thefollowing.if the supply cord is damaged,it must be replaced by the manufacturer,its service agent or similarly qualified persons in order to avoid a hazard. (8) The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube. (9) The appliance shall be installed in accordance with national wiring regulations. 2. Grounding Requirement: (1) The air conditioner is first class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. (2) The yellow-green wire in air conditioner is grounding wire, which cant be used for other purposes. (3) The grounding resistance should comply with national electric safety regulations. (4) The appliance must be positioned so that the plug is accessible. (5) An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring. (6) Including an air switch with suitable capacity, please te the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuitshort and overload. (Caution: please do t use the fuse only for protect the circuit) Air-conditioner 09/12/18K 24K 8.5 Installation of Indoor Unit Air switch capacity 10A 16A 1. Choosing Installation Iocation Recommend the installation location to the client and then confirm it with the client. 2. Install Wall-mounting Frame (1) Hang the wall-mounting frame on the wall; adjust it in horizontal position with the level meter and then point out the screw fixing holes on the wall. (2) Drill the screw fixing holes on the wall with impact drill (the specification of drill head should be the same as the plastic expansion particle) and then fill the plastic expansion particles

in the holes. (3) Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and then check if the frame is firmly installed by pulling the frame. If the plastic expansion particle is loose, please drill ather fixing hole nearby. 3. Install Wall-mounting Frame (1) Choose the position of piping hole according to the direction of outlet pipe. The position of piping hole should be a little lower than the wall-mounted frame.(as show in Fig.1) 09/12/18K Wall Wall Mark in the middle of it Level meter Space to the wall above 150mm Left Φ55mm Rear piping hole 24K Space to the wall above 150mm Right Φ55mm Rear piping hole 5. Connect the Pipe of Indoor Unit (1) Aim the pipe joint at the corresponding bellmouth.(as show in Fig.5) (2) Pretightening the union nut with hand. (3) Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union nut with torque wrench.(as show in Fig.6) (4) Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it with tape.(as show in Fig.7) Pipe joint Union nut Pipe Fig.5 Torque wrench Indoor pipe Open-end wrench Union nut Fig.6 Pipe Wall Space to the wall above 150mm Mark in the middle of it Level meter Space to the wall above 150mm Wall Fig.1 Insulating pipe Fig.7 Left Φ55/70mm Rear piping hole (2) Open a piping hole with the diameter of Φ55mm on the selected outlet pipe position.in order to drain smoothly, slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5-10.(As show in Fig.2) ote: Indoor 5-10 Outdoor Right Φ55/70mm Rear piping hole Φ55mm Fig.2 (1) Pay attention to dust prevention and take relevant safety measures when opening the hole. (2) The plastic expansion particles are t provided and should be bought locally. 4. Outlet Pipe (1) The pipe can be led out in the direction of right, rear right, left or rear left.(as show in Fig.3) (2) When selecting leading out the pipe from left or right, please cut off the corresponding hole on the bottom case.(as show in Fig.4) Refer to the following table for wrench moment of force: 6. Install Drain Hose (1) Connect the drain hose to the outlet pipe of indoor unit.(as show in Fig.8) (2) Bind the joint with tape.(as show in Fig.9) Fig.8 ote: Hex nut diameter(mm) Tightening torque(.m) Φ6 15~20 Φ9.52 30~40 Φ12 45~55 Φ16 60~65 Φ19 70~75 Outlet pipe Drain hose Drain hose Outlet pipe Tape Fig.9 (1) Add insulating pipe in the indoor drain hose in order to prevent condensation. (2) The plastic expansion particles are t provided. (As show in Fig.10) Fig.3 Right Rear right Left Rear left Drain hose Left Right Insulating pipe Fig.10 Cut off the hole Fig.4

7. Connect Wire of Indoor Unit (1) Open the panel, remove the screw on the wiring cover and then take down the cover.(as show in Fig.11) Fig.11 Panel Screw Wiring cover (2) Make the power connection wire go through the cable-cross hole at the back of indoor unit and then pull it out from the front side.(as show in Fig.12) Cable-cross hole 8. Bind up Pipe (1) Bind up the connection pipe, power cord and drain hose with the band.(as show in Fig.14) (2) Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose.(as show in Fig.15) (3) Bind them evenly. (4) The liquid pipe and gas pipe should be bound separately at the end. Indoor unit Indoor and outdoor power cord Gas pipe Power connection wire Fig.14 Band Liquid pipe Drain hose ote:this step only applicable for.american models. Fig.12 Connection pipe Drain hose Band (3) Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; tighten the screw and then fix the power connection wire with wire clip.(as show in Fig.13) Indoor power cord Fig.15 (1) 2 3 blue black brown yellowgreen ote: (1) The power cord and control wire cant be crossed or winding. (2) The drain hose should be bound at the bottom. ote: The wiring connect is for reference only, please refer to the actual one. (4) Put wiring cover back and then tighten the screw. (5) Close the panel. ote: Fig.13 Outdoor unit connection (1) All wires of indoor unit and outdoor unit should be connected by a professional. (2) If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself. (3) For the air conditioner with plug, the plug should be reachable after finishing installation. (4) For the air conditioner without plug, an air switch must be installed in the line. The air switch should be all-pole parting and the contact parting distance should be more than 3mm. 9. Hang the Indoor Unit (1) Put the bound pipes in the wall pipe and then make them pass through the wall hole. (2) Hang the indoor unit on the wall-mounting frame. (3) Stuff the gap between pipes and wall hole with sealing gum. (4) Fix the wall pipe.(as show in Fig.16) (5) Check if the indoor unit is installed firmly and closed to the wall.(as show in Fig.17) Indoor Wall pipe ote: Fig.16 Outdoor Sealing gum Fig.17 Upper hook Lower hook of wall-mounting frame Do t bend the drain hose too excessively in order to prevent blocking.

8.6 Installation of Outdoor Unit Refer to the following table for wrench moment of force: Hex nut diameter(mm) Φ6 Φ9.52 Φ12 Φ16 Φ19 1. Fix the Support of Outdoor Unit(Select it According to the Actual Installation Situation) (1) Select installation location according to the house structure. (2) Fix the support of outdoor unit on the selected location with expansion screws. ote: (1) Take sufficient protective measures when installing the outdoor unit. (2) Make sure the support can withstand at least four times the unit weight. (3) The outdoor unit should be installed at least 3cm above the floor in order to install drain joint.(as show in Fig.18) (4) For the unit with cooling capacity of 2300W~5000W, 6 expansion screws are needed; for the unit with cooling capacity of 6000W~8000W, 8 expansion screws are needed; for the unit with cooling capacity of 10000W~16000W, 10 expansion screws are needed. Tightening torque(.m) 15~20 30~40 45~55 60~65 70~75 5. Connect Outdoor Electric Wire (1) Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; fix the power connection wire with screws.(as show in Fig.23) 24K 09/12/18K (1) 2 blue 3 L black (1) yellow- green (green) brown(black) blue(white) brown yellowgreen Indoor unit connection 2 3 L blue black brown brown blue (black) L yellowgreen L POWER yellowgreen POWER Indoor unit connection Handle ote: the wiring connect is for reference only, please refer to the actual one. Drain vent Chassis Outdoor drain joint Drain hose At least 3cm above the floor Fig.18 Fig.19 2. Install Drain Joint(Only for cooling and heating unit) (1) Connect the outdoor drain joint into the hole on the chassis. (2) Connect the drain hose into the drain vent.(as show in Fig.19) 3. Fix Outdoor Unit (1) Place the outdoor unit on the support. (2) Fix the foot holes of outdoor unit with bolts.(as show in Fig.20) Foot holes Screw Foot holes Fig.23 (2) Fix the power connection wire with wire clip. ote: (1) After tightening the screw, pull the power cord slightly to check if it is firm. (2) ever cut the power connection wire to prolong or shorten the distance. 6. eaten the Pipes (1) The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. semidiameter of bending the pipe is 10cm. (2) If the outdoor unit is higher than the wall hole, you must set a U-shaped curve in the pipe before pipe goes into the room, in order to prevent rain from getting into the room.(as show in Fig.24) Handle Fig.21 Fig.20 4. Connect Indoor and Outdoor Pipes (1) Remove the screw on the right handle of outdoor unit and then remove the handle.(as show in Fig.21) (2) Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe.(as show in Fig.22) The drain hos can't raise upwards Wall Fig.25 U-shaped curve Liquid pipe Liquid valve Drain hose Pipe joint Fig.24 gas pipe gas valve Union nut Fig.22 (3) Pretightening the union nut with hand. (4) Tighten the union nut with torque wrench. ote: (1) The through-wall height of drain hose shouldnt be higher than the outlet pipe hole of indoor unit.(as show in Fig.25) (2) Slant the drain hose slightly downwards. The drain hose cant be curved, raised and fluctuant, etc.(as show in Fig.26)

(3) The water outlet cant be placed in water in order to drain smoothly.(as show in Fig.27) The drain hose can't be fluctuant The drain hose can't be fluctuant Fig.26 Liquid valve Gas valve Refrigerant charging vent ut of refrigerant Charging vent The water outlet can't be fluctuant Piezometer Valve cap Inner hexagon spanner The water outlet can't be placed in water 8.7 Vacuum Pumping and Leak Detection 1. Use Vacuum Pump (1) Remove the valve caps on the liquid valve and gas valve and the nut of refrigerant charging vent. (2) Connect the charging hose of piezometer to the refrigerant charging vent of gas valve and then connect the other charging hose to the vacuum pump. (3) Open the piezometer completely and operate for 10-15min to check if the pressure of piezometer remains in -0.1MPa. (4) Close the vacuum pump and maintain this status for 1-2min to check if the pressure of piezometer remains in -0.1MPa. If the pressure decreases, there may be leakage. (5) Remove the piezometer, open the valve core of liquid valve and gas valve completely with inner hexagon spanner. (6) Tighten the screw caps of valves and refrigerant charging vent.(as show in Fig.28) Fig.28 Lo Vacuum pump Close Open Fig.27 Hi 8.8 Check after Installation and Test Operation 1. Check after Installation Check according to the following requirement after finishing installation. o. Items to be checked Possible malfunction 1 Has the unit been The unit may drop, shake or installed firmly? emit ise. 2 Have you done the It may cause insufficient cooling refrigerant leakage test? (heating) capacity. 3 Is heat insulation of It may cause condensation and pipeline sufficient? water dripping. 4 Is water drained well? It may cause condensation and water dripping. Is the voltage of power 5 supply according to the It may cause malfunction or voltage marked on the damage the parts. nameplate? 6 7 8 9 10 11 12 Is electric wiring and pipeline installed correctly? Is the unit grounded securely? Does the power cord follow the specification? Is there any obstruction It may cause malfunction or damage the parts. It may cause electric leakage. It may cause malfunction or damage the parts. It may cause insufficient cooling in air inlet and air outlet? (heating) capacity. The dust and sundries caused It may cause malfunction or during installation are damaging the parts. removed? The gas valve and liquid It may cause insufficient cooling valve of connection pipe (heating) capacity. are open completely? Is the inlet and outlet of piping hole been covered? It may cause insufficient cooling (heating) capacity or waster eletricity. 2. Test Operation (1) Preparation of test operation The client approves the air conditioner installation. Specify the important tes for air conditioner to the client. (2) Method of test operation Put through the power, press O/OFF button on the remote controller to start operation. Press MODE button to select AUTO, COOL, DR, FA and HEAT to check whether the operation is rmal or t. If the ambient temperature is lower than 16, the air conditioner cant start cooling. 2. Leakage Detection (1) With leakage detector: Check if there is leakage with leakage detector. (2) With soap water: If leakage detector is t available, please use soap water for leakage detection. Apply soap water at the suspected position and keep the soap water for more than 3min. If there are air bubbles coming out of this position, theres a leakage.

9. Maintenance 9.1 Malfunction Analysis ote: When replacing the controller, be sure to insert the wire jumper into the new controller, otherwise the unit will display C5 Trip of breaker or The breaker trips at once when it is set to O. Measure insulation resistance to ground to see if there is any leakage. Air conditioner can t start up blow of fuse The air conditioner does t react after it is powered ( after the plug is inserted, the buzzer does t sound and the remote startup has response) The breaker trips in few minutes when it is set to O. o power Power plug is t well plugged in and poor connection. Fuse of controller burnt out The transformer connection is loose or has bad contact or the transformer has malfunction. The circuit or the part of the air conditioner has malfunction. They heat and break the insulation and lead to short circuit or creepage. Measure the insulation resistance or eliminate the malfunction one by one. If the breaker itself has malfunction, then replace the breaker. Check power supply circuit. Check if the plug is properly plugged in and make the loose contact firm. Change controller fuse Fasten the wiring; measure the output voltage of the transformer, if it is incorrect, change the transformer. Controller is broken Check remote controller Remote controller is short of power Change batteries The remote controller does t receive signals (after it is powered, the buzzer will sound, unless it has malfunction) Remote controller malfunction Receiver loose or poor connection Receiver is broken First, press the manual switch button AUTO,if there is response,check based on the above methods. If it runs rmally after pressing the button, check again whether the installation position and the connection wire of the reception head is correct. If it is correct,then replace the receiver or the remote controller. Power voltage is too low Check the voltage. If it is lower than 10% of the rated voltage, check the cause, improve the power supply condition and add the stabilized voltage power supply.

Improper set of temperature Adjust set temperature If cooling (heating) load is proper Check the forecasted load of cooling (heating) Malfunction of refrigerant flow The refrigerant has leakage or is insufficient Leakage between the high pressure and the low pressure inside the compressor Malfunction of four-way valve Check and fill the leakage, then vacuumize it and supplement the refrigerant as required Replace the compressor Replace the four-way valve Local block of capillary Replace the capillary Poor COOL(HEAT) operation Judge whether the system is blocked by observing the condensation of evaporator and the pressure value of the high Blockage of cooling system pressure mameter and take measures to deal with the system. Heat insulation for the connection Make sure that heat insulation for the thick and thin pipes pipes of the indoor unit and the outdoor unit is bad. is good. Heat insulation must also be provided for the joint andthe exposed part of the copper pipe. Block of outdoor heat exchanger the heat Clean the dust accumulated on the surface of exchanger. Air circulation is insufficient Air filter were blocked Fan speed was set too slow Fan rotation speed becomes low Clean the filter To set the fan speed to high or middle speed Capacitor Replace the capacitor damage Motor damage Replace the motor The installation position of the outdoor unit is t appropriate. Good ventilation must be provided for the installation position of the outdoor unit. The outdoor temperature is too high. The air tightness is t eugh. People come in and out too frequently. There are heating devices indoors. Properly install the rainproof plate or the sunproof plate. If the maximum cool air still can t meet the requirement, it is suggested to replace the air conditioner. Keep certain air tightness indoors, try t to use electricalappliance with large quantity of heat

Improper set of temperature Adjust set temperature If cooling (heating) load is proper Check the forecasted load of cooling (heating) Malfunction of refrigerant flow The refrigerant has leakage or is insufficient Leakage between the high pressure and the low pressure inside the compressor Malfunction of four-way valve Check and fill the leakage, then vacuumize it and supplement the refrigerant as required Replace the compressor Replace the four-way valve Local block of capillary Replace the capillary Poor COOL(HEAT) operation Heat insulation for the connection pipes of the indoor unit and the outdoor unit is bad. Blockage of cooling system Block of outdoor heat exchanger Judge whether the system is blocked by observing the condensation of evaporator and the pressure value of the high pressure mameter and take measures to deal with the system. Make sure that heat insulation for the thick and thin pipes is good. Heat insulation must also be provided for the joint andthe exposed part of the copper pipe. Clean the dust accumulated on the surface of the heat exchanger. Air circulation is insufficient Air filter were blocked Fan speed was set too slow Fan rotation speed becomes low Clean the filter To set the fan speed to high or middle speed Capacitor Replace the capacitor damage Motor damage Replace the motor The installation position of the outdoor unit is t appropriate. Good ventilation must be provided for the installation position of the outdoor unit. The outdoor temperature is too high. The air tightness is t eugh. People come in and out too frequently. There are heating devices indoors. Properly install the rainproof plate or the sunproof plate. If the maximum cool air still can t meet the requirement, it is suggested to replace the air conditioner. Keep certain air tightness indoors, try t to use electricalappliance with large quantity of heat

The torque of the swing motor is t eugh The swing fan does t run. Wrong connection The controller is damaged(ic2003 is damaged, the swing relay can t close, etc) First, check whether the connection is wrong. If, replace the parts In cool, heat mode, the outdoor unit and compressor will t run. Controller malfunction (IC2003 broken, creepage of parallel capacitor of relay loop, relay is broken etc.) Wire loose or wrong connection Improper setting of temperature Change controller Correctly wire according to the drawing Adjust setting temp. Water leakage Drainage pipe blocked or broken Wrap of refrigerant pipe joint is t close eugh. Change drainage pipe Re-wrap and make it tight. Fan of indoor unit contacts other parts Adjust fan location Foreign object in indoor unit Take out the foreign object Abrmal sound and shake Compressor shakes too much Touch of pipeline of outdoor unit Touch of inner plates Adjust support washer of compressor, and tighten loosen screws Separate the touching pipeline. 1. Tighten connect screw. 2. Stick absorbing clay between plates. Louver of outdoor unit touched outer case. Adjust location of louver. Abrmal sound inside compressor Change compressor

9.2 Flashing LED of Indoor/Outdoor Unit and Primary Judgement Display Method of Indoor Unit Indicator Display (during Malfunction O. Dual-8 blinking, O 0.5s and OFF ame Code 0.5s) Display Operation Cool Heating Display Method of Outdoor Unit Indicator has 3 kinds of display status and during blinking, O 0.5s and OFF A/C status 0.5s ellow Red Green Indicator Indicator Indicator Indicator Indicator Indicator Possible Causes 1 High pressure protection of system E1 OFF 3s once During cooling and drying operation, except indoor fan operates, all loads stop operation. During heating operation, the complete unit stops. Possible reasons: 1. Refrigerant was superabundant; 2. Poor heat exchange (including and bad radiating environment ); Ambient temperature is too high. 2 3 4 Antifreezing protection System block or refrigerant leakage High discharge temperature protection of compressor E2 E3 E4 twice 3 times 4 times 3 times 7 times and blink 9 times During cooling and drying operation, compressor and outdoor fan stop while indoor fan operates. The Dual-8 Code Display will show E3 until the low pressure switch stop operation. During cooling and drying operation, compressor and outdoor fan stop while indoor fan operates. During heating operation, all loads stop. 1. Poor air-return in indoor unit; 2. Fan speed is abrmal; 3. Evaporator is dirty. 1.Low-pressure protection 2.Low-pressure protection of system 3.Low-pressure protection of compressor Please refer to the malfunction analysis (discharge protection, overload). 5 Overcurrent protection E5 5 times 5 times During cooling and drying operation, compressor and outdoor fan stop while indoor fan operates. During heating operation, all loads stop. 1. Supply voltage is unstable; 2. Supply voltage is too low and load is too high; 3. Evaporator is dirty. 6 Communication Malfunction E6 6 times OFF During cooling operation, compressor stops while indoor fan motor operates. During heating operation, the complete unit stops. Refer to the corresponding malfunction analysis. 7 High temperature resistant protection E8 8 times 6 times During cooling operation: compressor will stop while indoor fan will operate. During heating operation, the complete unit stops. Refer to the malfunction analysis (overload, high temperature resistant). 8 EEPROM malfunction EE 15 times 11 times During cooling and drying operation, compressor will stop Replace outdoor control panel AP1 while indoor fan will operate; During heating operation, the complete unit will stop 9 Limit/ decrease frequency due to high temperature of module EU 6 times 6 times All loads operate rmally, while operation frequency for compressor is decreased Discharging after the complete unit is de-energized for 20mins, check whether the thermal grease on IPM Module of outdoor control the radiator is inserted tightly. If its use, please replace control panel AP1. 10 Malfunction protection of jumper cap C5 15 times Wireless remote receiver and button are effective, but can t dispose the related command 1. o jumper cap insert on mainboard. 2. Incorrect insert of jumper cap. 3. Jumper cap damaged. 4. Abrmal detecting circuit of mainboard.

O. Malfunction ame Display Method of Indoor Unit Indicator Display (during Dual-8 blinking, O 0.5s and OFF Code 0.5s) Display Operation Cool Heating Display Method of Outdoor Unit Indicator has 3 kinds of display status and during blinking, O 0.5s and OFF 0.5s ellow Red Green Indicator Indicator Indicator Indicator Indicator Indicator A/C status Possible Causes 11 Gathering refrigerant Fo 1 times 1 times When the outdoor unit receive signal of Gathering refrigerant,the system will be forced to run under cooling mode for gathering refrigerant ominal cooling mode 12 Indoor ambient temperature sensor is open/short circuited F1 once During cooling and drying operation, indoor unit operates while other loads will stop; during heating operation, the complete unit will stop operation. 1. Loosening or bad contact of indoor ambient temp. sensor and mainboard terminal. 2. Components in mainboard fell down leads short circuit. 3. Indoor ambient temp. sensor damaged.(check with sensor resistance value chart) 4. Mainboard damaged. 13 Indoor evaporator temperature sensor is open/short circuited F2 twice AC stops operation once reaches the setting temperature. Cooling, drying: internal fan motor stops operation while other loads stop operation; heating: AC stop operation 1. Loosening or bad contact of Indoor evaporator temp. sensor and mainboard terminal. 2. Components on the mainboard fall down leads short circuit. 3. Indoor evaporator temp. sensor damaged.(check temp. sensor value chart for testing) 4. Mainboard damaged. 14 15 16 17 Outdoor ambient temperature sensor is open/short circuited Outdoor condenser temperature sensor is open/short circuited Outdoor discharge temperature sensor is open/short circuited Limit/ decrease frequency due to overload F3 F4 F5 F6 3 times 4 times 5 times for 6 times and blink 6 times and blink 5 times and blink 7 times and blink 3 times During cooling and drying operating, compressor stops while indoor fan operates; During heating operation, the complete unit will stop operation During cooling and drying operation, compressor stops while indoor fan will operate; During heating operation, the complete unit will stop operation. During cooling and drying operation, compressor will sop after operating for about 3 mins, while indoor fan will operate; During heating operation, the complete unit will stop after operating for about 3 mins. All loads operate rmally, while operation frequency for compressor is decreased Outdoor temperature sensor hasnt been connected well or is damaged. Please check it by referring to the resistance table for temperature sensor) Outdoor temperature sensor hasnt been connected well or is damaged. Please check it by referring to the resistance table for temperature sensor) 1.Outdoor temperature sensor hasnt been connected well or is damaged. Please check it by referring to the resistance table for temperature sensor) 2.The head of temperature sensor hasnt been inserted into the copper tube Refer to the malfunction analysis (overload, high temperature resistant) 18 Decrease frequency due to overcurrent F8 8 times and blink once All loads operate rmally, while operation frequency for compressor is decreased The input supply voltage is too low; System pressure is too high and overload

O. Malfunction ame Display Method of Outdoor Display Method of Indoor Unit Unit Indicator has 3 kinds of Indicator Display (during display status and during Dual-8 blinking, O 0.5s and OFF blinking, O 0.5s and OFF Code 0.5s) 0.5s Display Operation Cool Heating ellow Red Green Indicator Indicator Indicator Indicator Indicator Indicator A/C status Possible Causes 19 Decrease frequency due to high air discharge F9 9 times and blink twice All loads operate rmally, while operation frequency for compressor is decreased Overload or temperature is too high; Malfunction of electric expansion valve (EKV) 20 Limit/ decrease frequency due to antifreezing FH 2 times 2 times and blink 4 times All loads operate rmally, while operation frequency for compressor is decreased Poor air-return in indoor unit or fan speed is too low 21 Voltage for DC bus-bar is too high PH 11 times and blink 13 times 1. Measure the voltage of position L and on wiring board (XT), if the During cooling and drying voltage is higher than 265VAC, turn operation, compressor will stop on the unit after the supply voltage while indoor fan will operate; is increased to the rmal range. 2.If the AC input is rmal, During heating operation, the measure the voltage of electrolytic complete unit will stop capacitor C on control panel (AP1), operation. if its rmal, theres malfunction for the circuit, please replace the control panel (AP1) 22 Voltage of DC bus-bar is too low PL and blink 21 times 12 times During cooling and drying operation, compressor will stop while indoor fan will operate; During heating operation, the complete unit will stop 1. Measure the voltage of position L and on wiring board (XT), if the voltage is higher than 150VAC, turn on the unit after the supply voltage is increased to the rmal range. 2.If the AC input is rmal, measure the voltage of electrolytic capacitor C on control panel (AP1), if its rmal, theres malfunction for the circuit, please replace the control panel (AP1) 23 Compressor Min frequence in test state P0 (during (during blinking, blinking, O O 0.25s 0.25s and OFF and OFF 0.25s) 0.25s) Showing during min. cooling or min. heating test 24 Compressor rated frequence in test state P1 (during (during blinking, blinking, O O 0.25s 0.25s and OFF and OFF 0.25s) 0.25s) Showing during minal cooling or minal heating test 25 Compressor maximum frequence in test state P2 (during (during blinking, blinking, O O 0.25s 0.25s and OFF and OFF 0.25s) 0.25s) Showing during max. cooling or max. heating test

O. Malfunction ame Display Method of Outdoor Display Method of Indoor Unit Unit Indicator has 3 kinds of Indicator Display (during display status and during Dual-8 blinking, O 0.5s and OFF blinking, O 0.5s and OFF Code 0.5s) 0.5s Display Operation Cool Heating ellow Red Green Indicator Indicator Indicator Indicator Indicator Indicator A/C status Possible Causes 26 Compressor intermediate frequence in test state P3 (during (during blinking, blinking, O O 0.25s 0.25s and OFF and OFF 0.25s) 0.25s) Showing during middle cooling or middle heating test 27 Overcurrent protection of phase current for compressor P5 15 times During cooling and drying Refer to the malfunction operation, compressor will stop analysis (IPM protection, loss while indoor fan will operate; of synchronism protection and During heating operation, the overcurrent protection of phase complete unit will stop current for compressor. operation. 28 Charging malfunction of capacitor PU 17 times During cooling and drying operation, compressor will stop Refer to the part three charging while indoor fan will operate; malfunction analysis of capacitor During heating operation, the complete unit will stop 29 Malfunction of module temperature sensor circuit P7 18 times During cooling and drying operation, compressor will stop while indoor fan will operate; Replace outdoor control panel AP1 During heating operation, the complete unit will stop 30 Module high temperature protection P8 19 times During cooling operation, compressor will stop while indoor fan will operate; During heating operation, the complete unit will stop After the complete unit is deenergized for 20mins, check whether the thermal grease on IPM Module of outdoor control panel radiator is inserted tightly. If its use, please replace control panel AP1. 31 Decrease frequency due to high temperature resistant during heating operation H0 10 times All loads operate rmally, while operation frequency for compressor is decreased Refer to the malfunction analysis (overload, high temperature resistant) 32 Static dedusting protection H2 twice 33 Overload protection for compressor H3 3 times 8 times During cooling and drying 1. Wiring terminal OVC-COMP operation, compressor will stop is loosened. In rmal state, the while indoor fan will operate; resistance for this terminal should During heating operation, the be less than 1ohm. complete unit will stop 2.Refer to the malfunction analysis ( operation. discharge protection, overload)