SPEEDY CARBONIUM TECHNICAL DATA SHEET

Similar documents
EUROSPRINT NEXT TECHNICAL DATA SHEET

ALTURA 619 EXTRA TECHNICAL SHEET

Instructions for Coating Fimbel Garage Door Panels

PRODUCT DATA KEFA AIRLESS 8125 and 8125B

Page 1 - MAINTENANCE OIL

Rhinoskin Spray On Insulation Ceramic Insulation Coating

Ekopel 2k. 2K bathtub resurfacing coating. pabrec.com. Description. Package. Advantages. Technical data sheet

STUCCO ITALIANO DI POLISTENA GIOVANNI. Viale S. Agostino, 346/A Vicenza - Italia Tel

VELVET MARMORINO. Fine natural mineral lime finish

Use a dry, soft-bristle brush to dust fabric weekly to remove dirt before it becomes embedded.

Coatings for protection of FRP structures with heavy rain erosion loads

SYSTEM DATA SHEET Sikafloor MultiDur ES-44 ESD

Application Instructions

Instructions for Coating Cellular PVC Solid Color (brushing and spraying)

Product Data Sheet. NeverStrip UV Resilient. Matte. A NeverStrip Instant Film Coating. UV Resilient Matte

Pot Belly Black. Overview. Suitable Surfaces

SLS Etch Primer. 300g aerosol, 250ml tin, 500ml tin, 1L tin, 4L tin

Maitenance guide N 3. for oiled DI LEGNO parquet floors white finishing

What you need to know...

MetaAlloy CI Primer Repair System

USED OIL RE-REFINING UNIT PRESENTATION. Manufactured by GADGIL & COMPANY PUNE

E-ZION - AUTO SHAMPOO CONCENTRATED CAR SHAMPOO

1542 Jefferson Street, Teaneck NJ TEL: FAX:

USING THE REFRIGERATOR COMPARTMENT

chiang mai What It Means To Be Green VINYL WALLCOVERING High Durability (Fed. Spec. CCC-W-408D) Fire Testing Type II

REGULAR MAINTENANCE AND CARE

HOW TO OPERATE THE REFRIGERATOR COMPARTMENT

Electron Microscopy Sciences

Professional cleaning detergents

SpectraPrime Color Primer Surfacer

PIZZA & BRACE WOOD FIRED OVEN

Reference Guide for DC 333

Dry Ice Blasting Frequently Asked Questions

The Heidelberg Integrated 14 CO 2 Sampler Institute of Environmental Physics, ICOS CRL

SpectraSeal 2.1 VOC Color Primer Sealer

Storage stable liquid urea-formaldehyde adhesive for the furniture and wood industry

MaxCel PLANT GROWTH REGULATOR COMMERCIAL CAUTION KEEP OUT OF REACH OF CHILDREN READ THE LABEL BEFORE USING

APPLICATION INSTRUCTIONS FOR MASCOAT SOUND CONTROL-dB

ACC is suitable for all types of diesel engines. The ACC / fresh water mixture has no flash point and cylinder lubrication is not impaired.

Safety Data Sheet. according to Regulation (EC) No 1907/2006 WICKES SMOOTH MASONRY

Now there's fresh air in your life!

The multi-layering continues throughout the whole pan ensuring excellent heat conduction performance from base to rim preventing hot-spots.

Handling, care, and correct ventilation

PROLAQ. New product for Cleaning solution for water & solvent based paints, varnishes & inks MAKING GREEN WORK.

HIT150221_RiceCooker_Cover_R3.pdf 1 11/4/16 4:55 PM

Equipment Specifications / Applications Guidelines

Laboratory Equipment Pty Ltd Instruction Manual Incubator IWJ Page 1

Dehumidifier. Instruction Manual. Model DH-320/A

ARRAY MODULAR FURNITURE Installation and Aftercare Instructions

Processing instructions V 400. REFRAMIX GP, REFRARAM GP: Basic multi-purpose mixes. REFRAMIX GP, REFRARAM GP: Basic multi-purpose mixes

Operating instructions Wine storage cabinet Page 16

KARCHERS POLISHERS OPERATOR MANUAL

Handheld Training Manual

MAINTENANCE SEAL MAINTENANCE PREVENTING WINDOW CONDENSATION. Kohltech.ca

SINGLE COMPACT DISC METALLIZATION TYPE SINGULUS III / 3

SPØ1 OUTDOOR CARE INSTRUCTIONS

Small nonprofit technical organization established in 1989 Identifies, develops, tests and demonstrates safer alternatives in consumer product and

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

Buehler Cast N Vac 1000 Embedding System

EY

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

BOOMER SYSTEMIC FUNGICIDE

Pro6 Duo. Stampa Novaprint - Tel cod USER MANUAL

The intense pleasure of wood

PULIZIA MANUTENZIONE PIANI

Maintenance Guide. for your Mercier prefinished floor PRINTED IN CANADA SP-CAREGUBIL 11-17

chlorination evolved FEEDERS New Design HIgh Efficiency Made in the U.S.A.

GENERAL PRODUCT CARE

Specification Document # page 1

PALLET CARD PROGRAM LABORATORY REPORT

IFU 005 CLEANING / PREPARATION OF OUTDOOR HEAT EXCHANGE SURFACES & COILS. Date Approved

J-PRO-22 Pump Proportional Feed Hydrogen Peroxide Installation & Start-Up Guide

Safety Data Sheet. according to Regulation (EC) No 1907/2006. SECTION 1: Identification of the substance/mixture and of the company/undertaking

R2310. Infrared Thermometer. Instruction Manual

LINOLEUM FLOOR CARE MANUAL

1.01 General requirements of the Project Manual shall apply to all work specified in this section.

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

Requests for Daily Care and Maintenance

2. PROCEDURE DESCRIPTION AND PROCESS FLOW

CARE INSTRUCTIONS BOOKLET

STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout

1. Table of Contents VisiJet Materials Overview Disclaimer Ispropyl Alcohol (IPA) and Polypropylene Glycol

TECHNICAL DATA 3% AR-AFFF

FOOD AREA SOLUTIONS Cleaning Spray & Wipe Disinfectant Skin Care Vegetable Cleaning Beerline Cleaning Sanitisers

For routine maintenance of polished granite installations with a cleaner and protector:

INFRARED RADIANT GAS SYSTEMS FOR THERMAL TREATMENTS

Photolithography SOPs

ST-1 Surface Treatment

Surface Preparation For Coatings

DS English... 5 Français Español CONSUMO DE ENERGIA. 1. En Operación: 287,82 Wh 2. En Modo de Espera: N/A Modelo: DS 5.

Table of Contents. English

Care and maintenance instructions for products supplied by VEKSØ A/S

smardy - pure water Reverse osmosis system YR100-A 75 GPD

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

Raw Copper Rust. Finish: Honed Recycled materials: 65% Variation: Size/thickness: 6 x 24 x 3/8 nominal 1. PRODUCT NAME 2. PRODUCT DESCRIPTION

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

Drop-In Specifications INTEGRATED DRAINAGE SYSTEM GEOMEMBRANE

Caractéristiques Unités Valeurs Méthodes. Appearance - Colourless Visual. Density (at 20 C) kg/cm³ 1,52 - Purity % 99,8 -

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Wallpaper Hanging Instructions

Transcription:

Product description Two-component medium-hard matrix antifouling based on the use of carbon as an active component to enhance performance. Quick drying (two coats in a day) and smooth film. It is applied by spray. After application, the film can be wet sanded with 600 grade abrasive paper to obtain an extra-smooth surface. It complies with the IMO (AFS/CONF/26) antifouling requirements and contains active substances appropriate to the BPR Regulation (Regulation (EU) No 528/2012). Product information Finish Matt Colour Black.708, Grey.712 The colour of the antifouling paint after diving may be slightly different. Small tinting differences may occur between different production batches: in case mix them before the application. Solids (by volume) ASTM D2369 53 ± 2 % Specific gravity UNI EN ISO 2811-1 1,60 1,70 g/cm³ Flash point UNI EN ISO 13736 30 C Typical Shelf life 3 anni VOC (calculated avarage content) ISO 11890-2/2006 461 g/l Packaging 0,75 2,5 Lt Application and use SURFACE PREPARATION This antifouling product is to be applied on itself, on new or renewed surfaces. On Speedy Carbonium: pressure wash, correct any defects and let it dry. New hulls in gelcoat: degrease with a detergent and rinse with fresh water; if there are still mould wax residues, we recommend a light wet sanding with 400 grade abrasive paper until the gelcoat is matt. Primerize with Adherglass or Adherpox. New wooden hulls: sanding with 80-120 grade paper. Primerize with Adherpox. 1

New hulls in steel and light alloy: sandblast SA 2½ or alternatively discing ST3 is recommended. Primerize with Adherpox. It is recommended to completely remove old antifouling every 3-4 years using an Aquastrip paint remover. APPLICATION PROCEDURE Stir the components for a few minutes to ensure a uniform consistency. Add component B to component A in the proportions indicated*, mix thoroughly and allow the mixture to rest for an induction time of about 1 hour. Apply the product by spray (5-10% dilution with Thinner 6470). Wait at least 4 hours (at 20 C) before applying the second coat and reinforce the whole waterline and the rudder with a third coat. If wet sanding is deemed necessary, wait until 24 hours after the last coat and use 600 grade abrasive paper until a completely uniform surface is achieved. For brush/roller applications, apply 2 coats, 5% diluted with Thinner 6470. It can stay exposed to air for up to 30 days without altering its performance. APPLICATION METHODS Professional use Application method (spray application is permitted using individual protective devices in suitable environments) Conventional Pressure 3,5 bar Nozzle 1,7 1,9 mm Airless Pressure 150 bar Nozzle 0.3 0.6 mm APPLICATION DATA Mixing ratio 2:1 by volume 67:33 by weight 2

Pot-life 48 hrs at 20 C Thinner/Cleaning tools 6470 Dry film thickness Wet film thickness Theoretical coverage at the recommended thickness N coats Recommended primers Standard application range 40-60 µm Recommended 50 µm Standard application range 80-120 µm Recommended 100 µm Application range at the 10,6 m recommended thickness 2 /liter 2 coats for a seasonal protection. Apply an extra coat in areas subjected to higher consumption/friction ADHERPOX suitable for all substrates TICOPRENE AL usable as primer on wood, iron, fiberglass or as insulator on old antifouling paints (Adherglass, Unikote PRO) Drying time 10 15 20 30 Temperature C Min Max Min Max Min Max Min Max Overcoating interval 18 hrs N.L. 12 hrs N.L. 6 hrs N.L. 4 hrs N.L. (50 µm) 1-6 1-3 1-3 1-2 Launching 24 hrs 18 hrs 12 hrs 8 hrs months months months months N.B. The drying times and the overcoating intervals increase with higher thickness of the applied film. Always check that the existing painting film is perfectly dry before applying a further product coat. 3

CONDITIONS DURING THE APPLICATION To avoid the formation of condensation, the temperature of the surface should be at least 3 C above dew point. During the application and curing the min. ambient temperature must not be lower than 10 C or higher than 30 C; substrate temperature must not be lower than 5 C, since curing is remarkably reduced at lower temperatures. Application is not advisable when relative humidity exceeds 80%. The term-hygrometric survey should be carried out near the surface to be coated. Make sure there is enough ventilation when the application takes place in closed areas. Storage It is recommended to avoid exposure to air and extreme temperatures. To maximize the shelf life in the can, it is good to check that the container is well closed during the storage and the temperature is between 5 C and 35 C. Avoid exposure to direct sunlight. Safety rules Observe the provisions of DPR 303 and 547. Avoid contact with the skin, for example. Operate in wellventilated places and, if in closed areas, use vacuum cleaners, fans and air conveyors. During the application use appropriate protections (masks, gloves, glasses, etc.). Before using, read sections 7-8 of the SDS. INSTRUCTIONS FOR THE DISPOSAL OF THE BIOCIDAL AND PACKAGING PRODUCT Empty packagings containing biocidal products: Dispose of empty packagings according to the requirements of the waste disposal law, for example by conferring them in the recycling center. Packages containing the unused biocidal product: Dispose of the product not used in accordance with the law of disposal of such waste, for example by conferring it in a recycling center, recycling of packaging is prohibited in this case. Do not empty into drains or watercourses. INSTRUCTIONS FOR THE SAFE SECURITY OF THE BIOCIDAL AND PACKAGING PRODUCT. Empty containers and containers still containing the biocidal product: Packaging must be disposed of as hazardous waste under the full responsibility of the holder of such waste. Do not empty into drains or watercourses. 4

Notes The values indicated in the present technical sheet can have slight variations from one batch to another. The applied product must not come in contact with water, chemicals or subjected to mechanical stress before the curing is complete. The wet film thickness is referring to the undiluted product. In case of dilution, this value increases. The above information is the result of accurate laboratory tests and practical experience, however, since the product is predominantly used outside the manufacturer's control, Boero Bartolomeo S.p.A. can only guarantee their quality. The information contained in this sheet may be subject to revision by the Company. For clarification, updates or further information, it is recommended to contact Boero Bartolomeo S.p.A. directly. The present datasheet annuls and replaces every other precedent to this one. Recommendations After the application of the last coat the maximum launching period of the antifouling is one month; with top quality copper oxide based products and with the agreement with our technical staff, the launching time may extend up to 3 months, providing that the hull is protected from moisture, rain or atmospheric agents with plastic or similar material. 5