LINEAR HEAT SERIES FIBER OPTIC LINEAR HEAT DETECTION SYSTEM

Similar documents
FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

Flexible Air-sampling Smoke Detection

For Complete Fire and Gas Solutions

PIPELINE LEAKAGE DETECTION

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

OH110, OP110, HI110 Automatic fire detectors

Praetorian Fibre Optic Sensing

WELL & RESERVOIR MONITORING

Praetorian Fibre Optic Sensing

Sensing Technology. A company of the BRUGG Group

Automated Fire Detection and Suppression in a Retrofitted Tunnel Using Fiber-Optic Linear Heat Detection

Searchpoint Optima Plus

SIMPLE AND RELIABLE FIRE DETECTION IN ROAD TUNNELS

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Industrial Strength Leak Detection

Danfoss gas detection unit Type GD Heavy Duty

LINEAR HEAT SENSING DETECTION. System Sensor India 2014

RESEARCH PAPERS FACULTY OF MATERIALS SCIENCE AND TECHNOLOGY IN TRNAVA, SLOVAK UNIVERSITY OF TECHNOLOGY IN BRATISLAVA, 2016 Volume 24, Number 39

Aspiration Systems for Smoke Detection

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

OOH740, OOHC740 Automatic fire detectors

WHITE PAPER FIBER OPTIC SENSING. Summary. Index. Introduction. About Fischer Connectors

Buys Time. Aspirating Smoke Detection

Temperature Monitoring and Leakage Detection for a Broad Portfolio of Industrial Assets

CEIA THS/PH21. series HIGH PERFORMANCE PHARMACEUTICAL METAL DETECTION SYSTEMS. Superior and Consistent Detection Enhanced Product Throughput Rate

Industrial Fire Detection

What guarantees a safe passage here?

Danfoss gas detection units

Asset Integrity Monitoring

Flame Detection Jon Sarfas

Industrial fire alarm systems

AV6419 BOTDR. Product Overview. Main Features

UniVario Industrial Fire Detectors Versatile in Application

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Chapter 1. Introduction

Praetorian Fibre Optic Sensing

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

LaserFOCUS VLF-250 Engineering Specification

Buys Time. Aspirating Smoke Detection

Safety vacuum drying oven for flammable solvents

Bernstein product overview

RaySense. Fiber Optic Distributed Vibration Sensing (DVS) for Pipeline Security and Leak Detection

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

MHD 535. General functions and specific requirements

Maxline 2 Thermal Imaging Solutions for Manufacturing

SMD601 Plus. The most Sensitive Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities. Threat Detection through Electromagnetics

PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY.

OH720, OP720, HI720, HI722

Dome Fiber Optic Closure SC-221

Aspirated Smoke Detectors

HI-PE HIGH PERFORMANCE WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics

Talentum - Why use our Flame Detectors?

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Panel Mounted Fault Annunciator Series

Dräger Flame 2500 Flame Detection

Danfoss gas detection units

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

Product Specification

TrueAlarm Smoke Detectors

AlarmLine Linear Heat Detector

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

SDAV VIA DETECTORS FOR HIGH-SPEED LINES

SPECIFICATIONS OM- ARA- NET OM- ARA- TF CONTROLLER OPTICAL FIBER NET INTRUSION DETECTION SYSTEM

Turbimax CUE21 / CUE22

The World's No. 1 Brand of Air-sampling Smoke Detector

RSL Fiber Systems, LLC

Extended Range DUAL TEC Motion Sensor

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Environmental simulation chamber for complex alternating climate profiles

Presented By. BEI Security

CCU Family of Modules

Quick Selection Guide Analog Addressable Fire Systems

Fire Detection systems. UniVario industrial fire detectors for every job

Analogue addressable devices

FAAST PRODUCT RANGE Aspirating Smoke Detection

Dräger Flame 2100 Flame Detection

Open-area Smoke Imaging Detection (OSID)

CEIA THS 21 series INDUSTRIAL METAL DETECTION SYSTEMS. Superior Detection Capabilities. Maximum Configurability

Leak Detection - Application Note

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

FAAST. Fire Alarm Aspirating Sensing Technology

PMD2 Plus ENHANCED WALK-THROUGH MULTI-ZONE METAL DETECTOR. Threat Detection through Electromagnetics. Superior Detection and Throughput

Mine Automation Technologies. know-how performance reliability

Quick Selection Guide Fire Systems LSN Periphery

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

YOUR PARTNER IN FIRE & GAS DETECTION

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Process Alarm Solutions

Notice of Proprietary Rights

Rules for Intruder Alarm Systems

Linear Heat Detection for Coal Conveyors. Application Guide

HART XL High Sensitivity Smoke Detection

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

talentum Flame detection across the spectrum Range Brochure

Transcription:

InnoVfoam B.V. Lorrie 9 1724 BL Oudkarspel T. +31 (0)88 9112 112 F. +31 (0)88 9112 119 www.innovfoam.com info@innovfoam.com

InnoVfoam s Linear Heat Series has been designed to minimize your operational costs and to work with maximum reliability under severe environmental conditions like: Dirt, Dust, Corrosive Atmospheres High Humidity Dynamic Temperature Fluctuations Solvent Vapors, Radioactive Radiation ATEX Classified Areas WOULD YOU LIKE TO MINIMIZE MAINTE- NANCE EFFORTS IN LARGE SCALE FACILI- TIES? In general safety systems demand highly reliable and extremely quick fire detection. Solutions need to be immune to interference and free of false alarms. They should continue to monitor regardless of the enormous heat and rapid spread of smoke. With conventional means, fulfilling these requirements requires complicated installation, commissioning and maintenance efforts. This is particularly the case in large, distributed manufacturing facilities, refineries, power plants, silos, warehouses, cold stores, conveyor belt systems, cable trays and tunnels. InnoVfoam s DTS systems address these problems by using standard fiber optic cable as a precise, distributed heat sensor. They are easy to install and virtually maintance free. The fiber optic cable can withstand extremely high temperatures and can be several thousand meters long. 2

Return Signal INNOVFOAM S - PERFECT FOR YOUR MISSION No doubt, InnoVfoam s fire protection technology suits your fire safety demands and saves you money, especially for large scale applications in hazardous environments. APPLICATION Tunnel / Large Sized Facility Cable Tray / Transformer / Generator Conveyor Belt / Silo False Floor / Inaccessible Area Cold Store Mining / Refinery / Floating Roof Tanks Nuclear Power Plant / Disposal SOLUTION just one cable immune to EMC immume to dirt and dust maintenance free immume to humidity ATEX certified immune to radiation and corrosive atmospheres All InnoVfoam s systems are designed and proven to ensure maximum quality with the lowest failure rate in the industry. Brillouin scattering Incident light Brillouin scattering Fiber is the distributed sensor Raman anti-stokes Signal Temperature dependent Raman Stokes Signal Temperature dependent Return Signal Wavelength SENSITIVITY IS A MATTER OF YOUR INDIVIDUAL SETTINGS In large scale applications the sensor cable will often run through different areas with various temperature conditions. The portal areas of tunnels, for example, are more effected by daily or seasonal temperature fluctuations than areas inside the tunnel. To cover various temperature conditions efficiently and accurately, InnoVfoam s Linear Heat Series enables you to configure different sensitivities on the same cable run, regardless of how long your sensor cable actually is. The fastest fire detection and lowest false alarm rate are in balance even with difficult conditions and different applications. All alarm conditions are met using various alarm criteria simultaneously such as maximums, rates-of-change, and an intelligent adaptive maximum criteria which takes the ambient temperature into account. 3

FIRE MONITORING, NOT JUST DETECTION InnoVfoam s Linear Heat Series capabilities are far beyond conventional fire detection systems. The systems have the capacity to not only detect fires quickly; but, to also detect individual fires precisely within a few meters. The systems are unaffected by wind and able to determine the size and direction of a spreading fire over time. No other fire detection system is able to withstand temperatures up to 1000 C, 1832 F, without losing monitoring capability. Fiber optic based fire detection and monitoring systems allow fire fighting counter measures to be used effectively before and throughout the fire event. Activation of suppression System Fire in tunnel Temperature [ C] 500 C 300 C Monitoring of fire size and spreading 100 C Alarm Trigger Zone A Time Zone B Location in tunnel Zone C Zone D 30s 300s 600s WE OFFER THE RIGHT SENSOR CABLES FOR YOUR APPLICATION Regardless of dirt, dust, corrosive environments, organic vapors, extreme temperatures or radiation we offer the sensor cable that best fits your needs. InnoVfoam s solutions include cables for low cost, standard or specialized applications. All cables have an expected lifespan of 30 years and are maintenance free. EASY INTEGRATION INTO YOUR MANAGEMENT SYSTEM The system can be integrated easily into your management platform (e.g. SCADA systems) by either directly communicating over Ethernet (TCP/IP), using SCPI (Standard Commands for Programmable Insruments), or Modbus RS 232, RS 422, RS 485 and TCP/IP. Additionally, it can be combined with a relay extension module which can trigger up to 256 relays per channel. If needed, these relays are used to extend the 20 embedded relay outputs offered by the instrument. 4

SAFETY FEATURES InnoVfoam s Linear Heat Series is designed for worry free operation in hazardous environments. FEATURES Fast, accurate and reliable fire detection Industry leading technology, quality and lifespan BENEFITS Highest safety and lowest false alarm rate even in hazardous environments Reduced service and support costs Freely programmable alarm criteria per zone Sensor cables are imperishable against environmental influences and maintenance free Sensor cables are ligh, flexible and easy to install Sensor cables offer highest durability against temperatures up to 1000 C (1832 F) Easy system integration, scalability, standard interfaces and protocols Low power semiconductor laser and single receiver design Different alarm sensitivities on the same cable run allows precise and selective trigger of counter measures. Worry-free permanent operation even in hazardous areas with lowest cost of ownership. Reduced installation efforts and easy deployment in cable route, underground conveyor belts, storage facilities and false floors. Fire spread and size assessment at the scene of accident to activate and supervise counter measures effectively. Plug & Play capabilities, regardless of the given technical environment Enables inherently safe operation with maximum lifespan, widest operating temperature range and lowest power consumption. Up to 256 freely configurable alarm zones with up to 5 alarm parameters per zone: static maximum adaptive maximum (takes ambient temperature into account) three individual temperature gradients to cover different heat risings Fiber break detection and localization Real loop / dual ended measurement mode with automatic fiber break recovery Direct triggering of alarms can be performed with up to 256 potential-free relay outputs, can be used for direct activation of sprinklers, horns, ventilation system andmuch more DTS Calibration Wizard allows easy calibration of each fiber segment, accounting for splices, connectors, or variances in fiber properties Provides an easy to understand loss (db) trace like an OTDR 5

Temperature ( C) Alarm Alarm Alarm Av. temp > 11 C > 13 C 40s Distance (m) Distance (m) Time (s) Exceeding a maximum temperature Exceeding the average temperature Exceeding a temperature increase within > 50 C by > 15 C a certain time > Δ 13 C / 40s CERTIFICATIONS VdS EN54-5, lass A1 Product Safety: IEC 61010-1:2001 and deviations acc. to CAN/CSAC22.2 No. 61010-04; UL 61010-1:2004 Laser Safety: IEC 60825-1:2001 FDA ackn. for Laser Sources: Class 1M; FDA 21CFR 1040.10+ Laser Notice No. 50 Electro-Magnetic Compatibility: IEC 61326:2002 Environmental Testing: IEC 60068-2-6/-64; IEC 60068-2-27 ISO 9001:2000 UL 521, ULC S530 Contact: InnoVfoam B.V. Lorrie 9 1724 BL Oudkarspel T. +31 (0)88 9112 112 F. +31 (0)88 9112 119 www.innovfoam.com info@innovfoam.com 6