Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs. Hauck Part No. Voltage Mounting Base Flame Detectors Display Units Amplifiers Flameout Response RM7890A 302263 RM7890B 302264 RM7840E* 57251 120 VAC 50-60 Hz 120 VAC 50-60 Hz 120VAC 50-60 Hz Q7800A-BASE C7027A-1049-UV C7035A-1023-UV Flame Rod (Consult Hauck) S7800A-DISPLAY R7849A-UVAMP R7847A-FRAMP 3 sec Q7800A-BASE C7061A-1012-SC S7800A-DISPLAY R7861A-SCAMP 3 sec Q7800A-BASE C7027A-1049-UV C7035A-1023-UV Flame Rod (Consult Hauck) S7800A-DISPLAY R7849A-UVAMP R7847A-FRAMP 3 sec * Separate purge timer must be specified (see FRU-1.2). The RM7890A and RM7890B provide microprocessor-based burner control for automatically fired gas, oil or combination fuel single burner applications. Expanded annunciation, remote reset, flame signal strength and other options are available. The RM7890B also contains a self-checking scanner and is recommended for systems which operate for more than 24 hours. The RM7840E provides complete system sequencing for single burner applications. The RM7840E will, upon a heat demand or input from the burner controller, start the burner blower, purge the system and initiate ignition and burner operation. No external purge circuit is necessary. The RM7840E is commonly applied to package burner systems. FRU-1, P.O. Box 90, Lebanon, PA 17042 Phone: 717-272-3051, Fax: 717-273-9882 www.hauckburner.com 2007 Printed in U.S.A. 06/07
Flame relay accessories are required for safe operation of combustion applications. Additionally, some accessories provide helpful troubleshooting and convenience features. Flame Relay Mounting Bases Hauck Part No. Applicable Flame Relay Enclosure Rating Q7800A-BASE 56649 All RM 7800 Series NEMA 1 Hauck Part No. Color Code R7849A-UVAMP 56650 Purple R7847A-FRAMP 60786 Green Flame Relay Amplifiers Applicable Flame Relays RM7890A RM7840E RM7890A RM7840E Applicable Flame Detectors C7027A-1049-UV C7035A-1023-UV Minimum Acceptable Maximum Expected 1.25 VDC 5 VDC Flame Rod 1.25 VDC 5 VDC R7861A-SCAMP 62659 Purple RM7890B C7061A-1012-SC 1.25 VDC 5 VDC FRU-1.1, P.O. Box 90, Lebanon, PA 17042 Phone: 717-272-3051, Fax: 717-273-9882 www.hauckburner.com 2007 Printed in U.S.A. 06/07
Flame relay display units provide annunciation on unit operation and system status information. Fault history is retrievable. Flame signal strength is also displayed on the unit. Display Unit Hauck Part No. Applicable Flame Relays S7800A-DISPLAY 302268 RM7890A RM7890B RM7840E Purge Timers Hauck Part No. Purge Time (sec) ST7800-2 57253X001 2 ST7800-7 57253X002 7 ST7800-10 57253X003 10 ST7800-30 57253X004 30 ST7800-40 57253X005 40 ST7800-60 57253X006 60 ST7800-90 57253X007 90 ST7800-150 57253X008 150 FRU-1.2, P.O. Box 90, Lebanon, PA 17042 Phone: 717-272-3051, Fax: 717-273-9882 www.hauckburner.com 2007 Printed in U.S.A. 06/07
Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs. Hauck Part No. Voltage Mounting Base Flame Detectors Programmer Amplifiers Flameout Response MEC120RC 300143 120 VAC 50-60 Hz 61-5042 UV1A6 MEP104 MEUV4 3 sec The MEC120RC provides microprocessor-based burner control for automatically fired gas, oil or combination fuel single burner applications. Expanded annunciation, remote reset, flame signal strength and other options are available. FRU-2, P.O. Box 90, Lebanon, PA 17042 Phone: 717-272-3051, Fax: 717-273-9882 www.hauckburner.com 2001 Printed in U.S.A. 07/01
Flame relay accessories are required for safe operation in combustion applications. Flame Relay Mounting Bases Hauck Part No. Applicable Flame Relay Enclosure Rating 61-5042 63290 MEC120RC NEMA 1 Dimensions (Inches) Flame Relay Amplifiers Flame signal strength may be obtained by use of an AC/DC multimeter through test leads inserted into the test jacks on the amplifier module. Hauck Part No. Color Code Applicable Flame Relay Applicable Flame Detector Minimum Acceptable Flame Signal Maximum Expected Flame Signal MeuV4 300144 N/A MEC120RC UV1A6 4 VDC 10 VDC FRU-2.1, P.O. Box 90, Lebanon, PA 17042 Phone: 717-272-3051, Fax: 717-273-9882 www.hauckburner.com 2001 Printed in U.S.A. 07/01
Flame relay programmer units provide annunciation on unit operation and system status information. A coded sequence under lockout condition will indicate the type of fault detected. Flame signal strength is also displayed on the unit. Programmer Unit Hauck Part No. Applicable Flame Relay MEP104 300145 MEC120RC FRU-2.2, P.O. Box 90, Lebanon, PA 17042 Phone: 717-272-3051, Fax: 717-273-9882 www.hauckburner.com 2001 Printed in U.S.A. 07/01