Technical

Similar documents
New Power Vented Rheem FVIR Tanks

Guardian PowerVent Training Manual. Flammable Vapor Ignition resistant (FVIR) compliant PowerVent water heater manufactured after 1 January 2006

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Ultra Low NOx PowerVent with Honeywell Electronic Control California Only

Technical

Technical

Technical

Technical

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

Operator: Save these instructions for future use!

21D83M-843 Integrated Single Stage Furnace Control Replacement Kit INSTALLATION INSTRUCTIONS

Hot Surface Ignition (HSI) System Booklet


Figure 10 or Figure 6

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

24 VAC Direct Spark Gas Ignition

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

Interrupted Ignition Series Oil Primary Control

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

DOMESTIC HOT WATER Follow operational sequence

Model 60200FR Gas Primary Control Data Sheet

USER S INFORMATION MANUAL

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

24 VAC Intermittent Pilot Gas Ignition Control

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

CSD-1 COMMERCIAL BOILER CONTROLS

A-1106 ACCESSORY KIT INSTALLATION INSTRUCTIONS IGNITION CONTROL P/N S , S , S

2017 OUTDOOR CONTROL SYSTEM WEATHER BEATER ELECTRONIC CONTROL SYSTEM

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

CAUTION WARNING. 50T Integrated Furnace Control INSTALLATION INSTRUCTIONS DESCRIPTION PRECAUTIONS

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

Operator: Save these instructions for future use!

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

RESIDENTIAL POWER VENT GAS-FIRED WATER HEATERS (EQUIPPED WITH FVIR TECHNOLOGY) OWNER S MANUAL SUPPLEMENT

A.O. Smith Water Products Company

BOSCH CONDENS 5000W ZSB18-2A

Operator: Save these instructions for future use!

EUROBOX SERIES TYPES CM... SM... MM...

Technical by adjusting

Flame Safeguard Fault Code Diagnostics

BGH Series Hot Surface Ignition Control

USER'S INFORMATION MANUAL

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

TO DO IF YOU SMELL GAS

Operator: Save these instructions for future use!

MG & SG SERIES BOILERS

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

PDV(S,T) MODEL SERIES AND INDUCED DRAFT (D80T725, D65T625) MODEL SERIES WATER HEATERS WITH HONEYWELL INTEGRATED CONTROL SYSTEM

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

SERVICE MANUAL. PV Series. Power Vent Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

USER S INFORMATION MANUAL

USER'S INFORMATION MANUAL

50M TYPICAL WIRING DIAGRAM 24 VAC CLASS II TRANSFORMER 24 VAC 50M COOL PARK HEAT LO HEAT HI LINE XFMR EAC HUM

LAE10 LFE10. Use. Series 02

USER'S INFORMATION MANUAL

SERVICE MANUAL. TTW Series Through-The-Wall Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

50A Integrated Furnace Control

OWNER S MANUAL SUPPLEMENT

SERVICE MANUAL. PDV Series. Power Direct Vent Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

50A Integrated Furnace Control

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

Typical Mount Height. Combustion Chamber

SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.)

Quickheat 30 weather compensated boiler control

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

USER'S INFORMATION MANUAL

Technical Manual MAY 2008 Edition

Q - Series Boiler. Troubleshooting Manual

50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

4.6 Advanced Propane Appliance Service and Troubleshooting Performance-Based Skills Assessment 2019

SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.)

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

COMMERCIAL GAS WATER HEATERS

USER'S INFORMATION MANUAL

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Service Guide. Service Guide NATIONAL COMFORT PRODUCTS GAS & ELECTRIC MODELS. 2nd Edition

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

SERVICE MANUAL. Residential D Series. Gas Water Heaters. Troubleshooting Guide and Instructions for Service. Models Covered by This Manual:

Service Handbook COMMERCIAL GAS WATER HEATERS

Flame Safeguards LFE10. Building Technologies HVAC Products

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

AXIAL HEATER TROUBLE SHOOTING GUIDE. Models: AX24 N/PV, AX24 N/PV LT, AX24 LP AX26 N/PV, AX26 N/PV LT, AX26 LP AX28 N/PV, AX28 N/PV NT, AX28 LP

EUROBOX SERIES TYPES CM...N SM...N MM...N

GAS UNITS KITS AND ACCESSORIES 505,172M 08/06

User s Information Manual

EUROFLAT SERIES TYPES C... S... M...

Service Handbook COMMERCIAL GAS HIGH EFFICIENCY WATER HEATERS

COMMERCIAL 24 VOLT FLUE DAMPER

Transcription:

S SEQUENCEE OF OPERATIONS All voltage inputs are 120V. Neither a surge protector nor GFI circuit is recommended or required. All electrical connectors are Molex and fit one way. The word control in this sequencee will normally refer to the electronicc control module on the gas valve. The control constantly monitors the water temperature via the thermistor so that the water temperature is within the user-selected temperature range. Control monitors the inputs for any fault conditions and presence of flammable vapors. If Call for Heat hass not initiated for more then 6 hours, the control will automatically decrease the differential by 5 F. If the temperature is still not less than the set temperature minus differential, the control continues in Stand-by mode. Tank is cold and full of water. Gas supply is connected. Gas valve is set to ON position. Unit is plugged into a 3- prong plug. Unit is polarity sensitive. Turn temperature dial down to LOWEST position. Turn rocker switch to ON position. Fill tank. Connect gas. Turn valve ON. Must be plugged into a 3-prong wall socket. Socket must be wired polarity correct. Black wire to brass screw; white wire to silver screw. Rocker switch controls all power inputs to blower motor, gas valve, and control module in gas valve. You will always have 120V at the red #3 wire. At power ON and a demand for heat, the control performs a self-test diagnostic routine. If the self-check fails, the control locks out with a solid ON LED light. - 1 -

Turn temperature dial to temperature selection. Initiates a call for heat. The white triangle next t to WARM is the 120-degree setting. Temperature is sensed electronically by the Thermistorr in the sensing bulb. It is the two whitee wires at the RED Molexx connector. (See Fig 3 on page 10.) ) 120V power is passed from the red # 3 wire thru the control to the yellow #5 wire and to the blower motor. This is the only source of AC power for the blower motor. (1st Safety) Control checks for OPEN vacuum switch. blue #8-vacuum switch wire. Note: The over-temp switch in the blower is wired in series. If the vent temp exceeds 180 0 F, then the over-temp switch will activate. LED will flash 3/3. In normal operation, thee switch is OPEN at beginning of call for heat. If no blower motor, then check: 120V power at the #5 yellow wire Vacuum switch tubing Vacuum switch Vent over-temperature switch is not activated If vacuum switch has failed in the closed position, the control attempts to openn the switch by cycling (turning off blower, then on) thee blower motor. After 5 cycles (attempts), the control will lockout. LED code is 3/ /1. - 2 -

(2nd Safety) Control turns on blower motor. This creates enough venting to close the vacuum safety switch. Blower is in pre-purge stage for about 15 seconds. yellow (#5-blower motor) wire. If you hear spark, then there is 120V power at the yellow # 5 location. Ignition attempt Spark ignitor begins to spark. (Orange wire) 120V voltage opens pilot vein of gas valve. yellow #7 pilot valve wire. In normal operation, thee control checks for a closed vacuum switch within 12 seconds before starting the pre-purge time. The vacuum switch measures the vacuum created by the blower and verifies the blower is operating at speed. Thee control attempts to close the switch by cycling (turning off blower, then on) thee blower motor. After 5 cycles (attempts), the control will lockout. LED flashed 3/3. Listen for spark ignitor. Visually verify spark att the pilot electrode. Check to make sure thee valve is turned ON. Check for voltage to thee pilot valve yellow #7 wire connection. Visually verify pilot flame is present. - 3 -

(3rd Safety) Flame is rectified. Pilot lights. After pilot flame has been recognized (rectified), the spark will stop Main valve is energized. Note: Theree is always a flame rectification circuit check while the main burner is operating. When the main burner fails, the unit will recycle and attempt ignition. Main valve on gas valve opens. blue #6 main valve wire. The trial for ignition will last for 75 seconds. If the control is not able to establish a pilot flame, it will initiate the inter-purge. This is a 30 second purge without spark or gas to clear thee combustion chamber. Then the unit will retry for ignition. The unit will try 3 times total for ignition. If ignition fails, it will initiate a post-purge (30 seconds) ) to clear the combustion chamber; then go into lockout. LED flashes 1/ /1. - 4 -

Main burner ignition. The flame rectification circuit is constantly ON during pilot and main burner. If the control module thinks flame is suppose to be present, then the circuit constantly looks for the presence of flame. Water heats to thermostat setting. (4th Safety) Blower motor thermal safety switch is monitoring venting temperatures. Flammable Vapor (FV) sensor is monitoring. Check for 120V power to the main valve (blue wire) side of the gas valve. If the unit rectifies flame for at least 10 seconds, the internal counter resets to zero. If the flame is established and then lost, the control will turn off the main and pilot valve, execute an inter-purge and then start a (30 seconds) new trial for ignition sequence. ECO is monitoring water temperature. Blower motor thermal safety switch set to 180 F withh automatic reset. FV Sensor is monitoring local environment for presence of flammable vapors - 5 -

Water is heated. Thermostat and control module shuts off all power to the unit. Unit is in stand-by mode. (The electronic control checks to see if the water temp is close to the set point. If so, it will attempt to turn the main burner on. For instance, if the set point is 120 0, then after 6 hours, the control module will adjust the set point back to 115 0 to see if it can fire off the main burner.) Unit is in Stand-by mode In stand-by mode, the control module constantly monitors the water temperaturee via the thermistor to ensure thee water inside the tank is within the user-selected d range. In addition, the control will monitor the inputs to look for any other fault conditions such as a control health, false flame or faulty switches. Unit monitors control health and the local environment for flammable vapors as long as there is 120 VAC to the water heater. False sensing The blower will turn on immediately if flame is sensed when no flame should be present. Flame with gas valve off - If there is proof of flame for 10 seconds with the gass valve off, the control will go into lockout. The blower motor will run during lockout if there is prooff of flame. If there is proof of flame for less than 10 seconds, the unit will post- purge. LED flashes 4/3. - 6 -

ECO High Limit:(>200 0 F) The high limit switch opens after flame is established. That means the water inn the tank got over 200 0 F. The pilot valve, main valve, and spark ignition are turned off, but the blower will remain on. LED flashess 4/2. The ECO has a one-time use. D DIAGNOSTIC FLASH CODES System condition Stand-by mode Call for heat present Internal control failure/ miswiring Ignition failure Flammable vapors present Flammable Vapor Detector failure/ miswiring Vacuum switch fails to open Vacuum switch fails to close Line/ neutral polarity failure ECO failure False flame Vacation mode active Primary pattern Slow blink Fast blink ON Solid 2 blinks 2 blinks 4 blinks 4 blinks 4 blinks 5 blinks When a fault occurs within the water heater, the control will output a code using an LED. The LED willl have a variety of statuss conditions: ON is definedd as constantly on with no blinking patterns. Slow Blink is defined as a one blink per second. Fast blink is defined as five blinks per second. There will be a 1 second period between primary y and secondary pattern when LED will be off. (blink-one second-blink) After the secondary pattern completes, there will be a 3 second period when LED will be off before patterns repeat. (blink-one second-blink - - three seconds - - blink-one second- blink) Secondary pattern s 2 blink - 7 -