NKW. Heater series HEATERS

Similar documents
Series VENTS VUT R WH ЕС

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Duct electric heater with temperature controller

Duct electric heater with heating. capacity from 0.6 kw up to 2.4 kw and an integrated. temperature controller

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

CAW Ceiling-mounted fan heaters for hot water

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

VENTS КАМ. Series CHIMNEY CENTRIFUGAL FANS

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

Chapter 14, Problem 27.

HEATING AND COOLING DEVICE AGC

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Energy. The Energy ducted units have been designed. Heat Recovery Unit

Swegon CASA. duct coils for heating. the supply air

OXeN. Ductless ventilation with heat recovery.

Technical Data. Danfoss DHP-C. Provides heating, cooling and hot water TWS technology provides hot water quickly with low operating

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

PGDX Rectangular duct coolers with DX coil

Technical data. Danfoss DHP-L

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

Dirt and Air Separators

SINGLE-ROOM VENTILATION. for schools and public spaces

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Cata-Dyne LH Line Heater & Micro Line Heater

City of Duluth Festival Center 04/25

USER S MANUAL. VKP Series INLINE FAN

Fan heater SWT Ceiling mounted fan heater with water heat

USER S MANUAL DN-2. Drain pump

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Technical data. Danfoss DHP-A

Planning guide. (2010/09) en

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Heat Recovery Units. Heat Recovery 1

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

Technical documentation: S1 S2 S3 S4

H4T R410A. refrigerant

PROMAX XL MODELS CIRCULATING LOOP HEAT EXCHANGER MANUAL. Installation. Operation. Maintenance. Fill in the Rating Pate Information Here:

KOMFORT EC DB Suspended heat recovery air handling units

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

ErP OPERATIONS MANUAL FOR СOMMERCIAL CURTAINS PROTON HEAT DOOR C2. Safety precautions Construction and dimensions Technical parameters Installation

1.1 VTS: number 1 in the world pillars of success

Air Conditioning Clinic

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

CE311 Fall 2016 Mid-Term Exam 1

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

ENTROPIE boiler TT300

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

TopMaster Air Handling unit. Technical data

HOTEL CHILLED BEAM IQ STAR SILENCIA

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

1

EHH SERIES DRAW THROUGH FAN COILS CFM

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS

DC INVERTER AIR TO WATER HEAT PUMP AC series Heating & Cooling series CX45

Air heater/cooler in combination with ground source heat pump

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

UNIT 5 COOLING SYSTEMS OF IC ENGINES

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Heating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT

Cylinders for Domestic Purposes Heat Pumps

ENERGY FROM THE SUN. SOLAR THERMAL TECHNOLOGIES EDUCATION MODULE (sth01pp)

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Air handling units with an integrated heat pump and rotary heat exchanger

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Air curtain.

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

Centrifugal air heaters hot water or electrical supply

Contact, Overview, Index. Ceiling Heating/Chilled. Plexus. Professor. Pilot. Architect. Polaris I & S. Plafond. Podium. Celo. Cabinett. Capella.

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

lindab we simplify construction Lindab Modular air handling units Connection, start-up and commissioning manual

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

"HC" AIRFLO. In-duct firing line burner

42CW/CH. Fan Coil Unit (High Static Pressure) 42CW/CH. Welcome to Carrier Website w w w. c a r r i e r. c o m. c n

Shunt groups and protection against freeze damage

ATC Heating Devices. P. 1 ATC Heating Devices

VEX100 series Air handling units with cross-flow heat exchanger

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

Halton CHB Active chilled beam with boost function for bulkhead installation

Pressure Enthalpy Charts

Technology for life. Unit heater LH

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Plate Coil Heat Exchangers

Bulletin (Jan 2011) And User s Guide

"NP" & "RG" AIRFLO. In-duct firing line burner

RECOVERY COILS AND ECODIRECTIVE 2018: CONTROL AND DEFROST

Transcription:

HEATERS Heater series Applications Duct electrical heaters are designed for heating of supply air in rectangular ventilating system and are applicable in supply or supply and exhaust units. Design The heater casing is made of galvanized steel, the manifold is made of copper tubes and the heat exchange surface is made of aluminium plates. The heaters are available in 2, 3 or 4 rows modifications and designed for operation at maximum operating pressure 1,6 MPa (16 bar) and maximum operating temperature +100 С. The exhaust manifold of the heater has a branch pipe for submersible temperature sensor or iicng protecting device. The heater has a nipple to provide the system deaeration. Mounting The heater design ensures its mounting by means of a flange connection. The water heater can be installed in any position to enable its deaeration. The air stream shall match the pointer on the heater; The heater shall be installed in such a way as to enable the uniform air distribution along the entire cross section; the air filter shall be installed at the heater inlet to provide protection against dust and dirt; the heater can be installed both at the fan inlet or outlet. If the heater is located at the fan outlet the air duct length between the heater and the fan shall be at least 1-1.5 m to ensure the air flow stabilization as well as permissible air temperature level inside the fan; The heater shall be connected on the counterflow principle, otherwise its efficiency can drop by 5-15%. All the nomographic charts in the catalogue are valid for such connection; If waters serves as a heat transfer agent the heaters are designed for indoor installation only. For outdoor installation use antifreeze mixture (i.e. ethylene glycol solution); To ensure the correct and safe heater operation use the automation system that provides the complex control and freezing protection: automatic control of heating elements capacity and air heating temperature; Switching ventilating system on with preliminary heating by the heater; use of air curtains equipped with spring-loaded actuator; filter checking by means of differential pressure sensor; fan shutdown in case of water coils freezing danger. Connection against air flow Connection along air flow Designation key: Accessories Series Flange designation (WxH) [mm] - Number of water coil rows 400х200; 500х250; 500х300; 600х300; 600х350; 700х400; 800х500; 900х500; 1000х500 2; 3; 4 page 280 268

WWW.VENTILATION-SYSTEM.COM Overall dimensions: Type Dimensions [mm] B B1 B2 B3 H H1 H2 H3 L L1 L2 K Number of water coil rows 400x200-2 400 420 440 565 200 220 240 150 200 43 43 G 3/4 2 7,6 400x200-4 400 420 440 565 200 220 240 150 200 38 65 G 3/4 4 8,1 500x250-2 500 520 540 665 250 270 290 200 200 43 43 G 3/4 2 15,8 500x250-4 500 520 540 665 250 270 290 200 200 38 65 G 3/4 4 16,3 500x300-2 500 520 540 665 300 320 340 250 200 43 43 G 1 2 11,5 500x300-4 500 520 540 665 300 320 340 250 200 38 65 G 1 4 12,0 600x300-2 600 620 640 765 300 320 340 250 200 43 43 G 1 2 21,8 600x300-4 600 620 640 765 300 320 340 250 200 38 65 G 1 4 22,3 600x350-2 600 620 640 765 350 370 390 300 200 43 43 G 1 2 22,4 600x350-4 600 620 640 765 350 370 390 300 200 38 65 G 1 4 22,9 700x400-2 700 720 740 865 400 420 440 350 200 36 47 G 1 2 27,8 700x400-3 700 720 740 865 400 420 440 350 200 42 58 G 1 3 28,4 800x500-2 800 820 840 965 500 520 540 450 200 36 47 G 1 2 36,5 800x500-3 800 820 840 965 500 520 540 450 200 42 58 G 1 3 37,2 900x500-2 900 920 940 1065 500 520 540 450 200 36 47 G 1 2 40,4 900x500-3 900 920 940 1065 500 520 540 450 200 42 58 G 1 3 41,2 1000x500-2 1000 1020 1040 1165 500 520 540 450 200 36 47 G 1 2 44,3 1000x500-3 1000 1020 1040 1165 500 520 540 450 200 42 58 G 1 3 45,2 Mass [kg] HEATER VENTS. Industrial and commercial ventilation 11-2010 269

HEATERS Air Speed. Starting from 950 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.35 m/s. in/out temperature curve (90/70 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+23 С). intersection of water in/out temperature curve (e.g., 90/70 С). From this point draw a vertical line up to the scale of heating coil capacity (13.5 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.14 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (1.5 kpa). Air Speed. Starting from 950 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.35 m/s. in/out temperature curve (70/50 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+29 С). intersection of water in/out temperature curve (e.g., 70/50 С). From this point draw a vertical line up to the scale of heating coil capacity (16.0 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.2 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (2.1 kpa). 270 VENTS. Industrial and commercial ventilation 11-2010

WWW.VENTILATION-SYSTEM.COM Air Speed. Starting from 1450 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.2 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -15 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (90/70 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+24 С). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., -15 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 90/70 С). From this point draw a vertical line up to the scale of heating coil capacity (21.5 kw). water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.27 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (3.2 kpa). HEATER Air Speed. Starting from 1450 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.2 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -25 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (70/50 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+28 С). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., -25 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 70/50 С). From this point draw a vertical line up to the scale of heating coil capacity (31.0 kw). water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.38 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (9.8 kpa). VENTS. Industrial and commercial ventilation 11-2010 271

HEATERS Air Speed. Starting from 2000 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.75 m/s. in/out temperature curve (90/70 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+22 С). intersection of water in/out temperature curve (e.g., 90/70 С). From this point draw a vertical line up to the scale of heating coil capacity (28.0 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.35 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (3.8 kpa). Air Speed. Starting from 2000 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.75 m/s. in/out temperature curve (70/50 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+31 С). intersection of water in/out temperature curve (e.g., 70/50 С). From this point draw a vertical line up to the scale of heating coil capacity (35.0 kw). water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.43 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (9.0 kpa). 272 VENTS. Industrial and commercial ventilation 11-2010

WWW.VENTILATION-SYSTEM.COM Air Speed. Starting from 2000 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.75 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -20 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (90/70 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+20 С). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., -20 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 90/70 С). From this point draw a vertical line up to the scale of heating coil capacity (37.0 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.46 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (6.7 kpa). HEATER Air Speed. Starting from 2500 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.75 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -20 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (70/50 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+29 С). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., -20 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 70/50 С). From this point draw a vertical line up to the scale of heating coil capacity (48.0 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.6 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (14.0 kpa). VENTS. Industrial and commercial ventilation 11-2010 273