Technical Data. Dimensions

Similar documents
Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

PEPPERL+FUCHS GmbH

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Inductive slot sensor

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 5 mm

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR DP 7060 Supplementary Instructions

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

MANUAL Oil Level Sensor

VERSAFLOW VORTEX Supplementary instructions

EU DECLARATION OF CONFORMITY

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

SEK-3 Marine Grounding System

MANUAL Overflow sensor NVF-104/34-PF

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Temperature Measurement Transmitters for field mounting

4) Intrinsic Safety Certification

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Safety instructions VEGAPULS 64

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Dual certification! Air handling units for potentially explosive atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

INSTRUCTION MANUAL (ATEX / IECEx)

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Operating Instructions Edition 02/2007

Ultrasonic Level Measurement nivopuls FDU 10 S

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

DB5 Intrinsically Safe Sounder Type DB-5

Earth-Rite II PLUS Static Earthing System

Gas cylinder scale Model GCS-1

Annubar Flowmeter Series

Rosemount 752 Fieldbus Remote Indicator

INSTRUCTION & SERVICE MANUAL

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

DICTATOR Hold-Open Systems for Hazardous Areas

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

OPTIWAVE X500 Supplementary Instructions

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

Assembly. Host Sub-D Alarm

Installation and Operating Instruction

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

Product Information to the manual

Guide for hazardous areas

User s Manual YTA610 and YTA710 NEPSI Certification

Certificate of Compliance

Operating Manual MS220Vi and MSR220Vi

INSTRUCTION MANUAL (ATEX / IECEx)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

IECEx Certificate of Conformity

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Manual Power relay SR853

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

IECEx Certificate of Conformity

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Model 144H. Product Data Sheet , Rev DB February Content

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Model 144H. Product Data Sheet , Rev DB February Content

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Rosemount 2090P Pulp and Paper Pressure Transmitter

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

ATM Lighting sp. z o.o

Druck DPI 705/DPI 705 IS Series

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

OOH740-A9-Ex Multi-sensor fire detector

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

OOH740-A9-Ex Multisensor fire detector

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

FDOOT241-A9-Ex Multisensor fire detector

SET Installation and Operating Instructions. Level switch for one sensor

ATM Lighting sp. z o.o

Transcription:

0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR Assured operating distance s a 0... 40.5 mm Actual operating distance s r 45... 55 mm typ. Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions A 40 mm B 150 mm F 240 mm Nominal voltage U o 8.2 V (R i approx. 1 kω) Switching frequency f 0... 80 Hz Hysteresis H 0... 5 typ. 3 % Reverse polarity protection reverse polarity protected Short-circuit protection yes Current consumption Measuring plate not detected 3 ma Measuring plate detected 1 ma Time delay before availability t v 20 ms Switching state indicator LED, yellow Ambient conditions -25... 100 C (-13... 212 F) Storage temperature -40... 100 C (-40... 212 F) Mechanical specifications Connection type screw terminals Core cross-section 2.5 mm 2 Housing material PBT/metal Sensing face PBT Degree of protection IP67 information Use in the hazardous area see instruction manuals Category 1G; 2G; 1D Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibility NE 21:2007 Standards EN 60947-5-2:2007 IEC 60947-5-2:2007 Approvals and certificates FM approval Control drawing 116-0165 UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval CCC approval / marking not required for products rated 36 V Dimensions LED ø 9.5 80 11 65 40 1/2 NPT 65 ø 5.3 7 1

Electrical Connection 1 L+ 2 L- 2

ATEX 1G Device category 1G for use in hazardous areas with gas, vapour and mist PTB 00 ATEX 2032 X II 1G Ex ia IIC T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007 Ignition protection "Intrinsic safety" and in this instruction manual. The has to be observed. The special conditions must be adhered to! The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. Note: Use the temperature table for category 1!!! The 20 % reduction in accordance with EN 1127-1:2007 has already been accounted for in the temperature table for category 1. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy the requirements of category ia. Due to the possible danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation of the power supply and signal circuit is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. Protection from mechanical danger When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The apparatus is provided with an outer lacquered metallic screen, which must be protected from electrostatic charging. The metal housing parts are coated. If a conductive connection is required, this coating must be electrically bridged by suitable means. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. 3

ATEX 2G Device category 2G for use in hazardous areas with gas, vapour and mist PTB 00 ATEX 2032 X II 1G Ex ia IIC T6 T1 Ga Standards EN 60079-0:2012, EN 60079-11:2012 Ignition protection "Intrinsic safety" and in this instruction manual. The has to be observed. The special conditions must be adhered to! The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. Protection from mechanical danger When used in the temperature range below -20 C the sensor should be protected from knocks by the provision of an additional housing. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The apparatus is provided with an outer lacquered metallic screen, which must be protected from electrostatic charging. The metal housing parts are coated. If a conductive connection is required, this coating must be electrically bridged by suitable means. Additional requirements for gas group IIC. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS 60079-32-1. 4

ATEX 1D Device category 1D for use in hazardous areas with combustible dust ZELM 03 ATEX 0128 X Standards Maximum housing surface temperature II 1D Ex iad 20 T 108 C (226.4 F) IEC 61241-11:2002: draft; pren61241-0:2002 type of protection intrinsic safety "id" and in this instruction manual. The has to be observed. The special conditions must be adhered to! The maximum surface temperature of the housing is given in the EC-Type Examination Certificate. must be observed. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety. The associated apparatus must satisfy at least the requirements of category ia IIB or iad. Because of the possibility of the danger of ignition, which can arise due to faults and/or transient currents in the equipotential bonding system, galvanic isolation in the power supply and signal circuits is preferable. Associated apparatus without electrical isolation must only be used if the appropriate requirements of IEC 60079-14 are met. The intrinsically safe circuit has to be protected against influences due to lightning. When used in the isolating wall between Zone 20 and Zone 21 or Zone 21 und Zone 22 the sensor must not be exposed to any mechanical danger and must be sealed in such a way, that the protective function of the isolating wall is not impaired. The applicable directives and standards must be observed. To avoid sliding contact discharges, which are associated with applications involving high charges (e.g. electrostatic enamelling, film manufacture, anti-dust precautions, processes involving mechanical friction, etc.), the surface area of the plastic housing, which is exposed to this charging should be limited to approx. 15 cm2 by appropriate installation measures Electrostatic charging due to the flow of media during operation must be excluded. This can be achieved by limiting the surface area of the plastic housing exposed to the electrostatic charging to less than 100 cm 2. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. The apparatus is provided with an outer lacquered metallic screen, which must be protected from electrostatic charging. The metal housing parts are coated. If a conductive connection is required, this coating must be electrically bridged by suitable means. 5