www. ElectricalPartManuals. com I N S T R u C T I 0 N S WESTINGHOUSE RADIATORS INSTALLATION MAINTENANCE

Similar documents
www. ElectricalPartManuals. com \/' INSTRUCTIONS WESTINGHOUSE RADIATORS DESCRIPTION '- INSTALLATION MAINTENANCE

www. ElectricalPartManuals. com INSTRUCTIONS DRY TYPE TRANSFORMERS OPERATION AND MAINTENANCE OF

SECTION AIR HANDLING UNIT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

OWNERS GUIDE TO INSTALLATION AND OPERATION

Series 1140 and 1141 Temperature Regulators

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

Ceiling Sweep Fan Assembly Instructions

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

Lifetime Limited Warranty

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

Food Waste Disposer Instruction Manual

WAILEA OWNER S MANUAL

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

CEILING FAN OWNER'S MANUAL

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

Fan Motor. user manual INSTALLATION - OPERATION - MAINTENANCE

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

CEILING FAN OWNER S MANUAL

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Installation and operating instructions. E.2 Series high efficiency circulator

COLMAC COIL. Installation, Operation, and Maintenance ENG Rev A. Air Cooled Fluid Coolers. Contents. When you want Quality, specify COLMAC!

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

SECTION STEAM CONDENSATE PUMPS

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

SECTION (15833) - HVAC POWER VENTILATORS

Larson by Hampton Bay

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

installation and operation manual for Hunter Ceiling Fans

30-YEAR LIMITED WARRANTY

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

installation and operation manual for Hunter Ceiling Fans

#ADENCE4- $ESIGNED )NCLUDES #OOL4OUCH4- +ICHLER )NSTRUCTION #USTOMER KHA

READ AND SAVE THESE INSTRUCTIONS

Installation & Maintenance Instructions

Lifetime Limited Warranty

PRO Series Energy Star Ceiling Fan Owner's Manual

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

OTO BONDER OWNER S MANUAL WITH CIRCULATING SYSTEM MACHINERY DIVISION - - L to R Unit Shown

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

E.2 series high efficiency circulator. Installation and operating instructions

CEILING FAN OWNER'S MANUAL

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

VERTICAL GLANDLESS PUMP

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

CEILING FAN OWNER S MANUAL

CEILING FAN OWNER'S MANUAL

568X, 587X, 588X Series

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

Enviro KES INSTALLATON MANUAL

CF654AW00 CF654ORB00 CF654WB00 CF654WW00

Owner s Guide and Installation Manual

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

Power Washer Maintenance

SUNSEEKER BY INSTRUCTION MANUAL WARRANTY CERTIFICATE

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

SuperKlean Washdown Products

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

REPAIR PARTS LIST. Model Nos (White On White) (Bisque) (Black) (Graphite) REFRIGERATOR

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

Rotary XL (558 Series) and Classic (548 Series)

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

MASTERPIECE /THERMADOR PROFESSIONAL SERIES BUILT-IN OVEN

ST. KITTS CEILING FAN

52 STRATHMERE CEILING FAN

XPS-ProDry User s Guide Dryer Base

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

INSTRUCTION MANUAL with Replacement Parts

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Type 2 Models. Owner s Guide and Installation Manual. English Español

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

Parts and Service Manual

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

Patterson Fan Manual. Operating, Installation & Parts Manual (OIPM) Patterson Fan Company, Inc Blythewood, SC

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

Transcription:

FIG. 1. Westinghouse Single Radiators Mounted Perpendicular to the Wall of a Form-Fit Tank THE WESTINGHOUSE RADIATOR is a highly efficient cooling unit which is designed for use on large self-cooled transformers where high cooling capacities are required. It is detachable and may be removed for shipment, which reduces shipping clearances and relieves tank wall stresses which might develop due to sudden shocks in transportation. DESCRIPTION The radiator is of all-welded sheet metal construction, with vertical cooling sections through which the oil circulates and is cooled. A formed metal header, welded to each end of the assembly of sections, complete the structure and provides connections for the fittings which attach the radiator to the tank. The individual sections are made from two flat sheets of steel of the same length, each of which SUPERSEDES I.L. 46-734-1 I.L. 46-734-lA DESCRIPTION INSTALLATION MAINTENANCE I N S T R u C T I 0 N S WESTINGHOUSE RADIATORS is 115/s inches wide. To secure different lengths of radiators, these assemblies are made in lengths from four feet to fourteen feet, varied in steps of approximately one foot. The side edges of these sheets are welded together by an automatic resistance seam welding machine. Welded seams are made along the centerline the entire length of the section except for about six inches at each end. Air pressure is applied at one end of an element so that the sheets are forced apart and given a permanent set, where not restrained by the welds, to limits imposed by a restraining mould, thus forming the ducts for oil circulation. The ends are then sheared off and formed as shown in Fig. 3. This forming of the ends provides a means for proper spacing of sections, external welding surfaces and a "hip roof" shape which eliminates horizontal surfaces between sections and insures complete drainage. The formed header is welded to the formed ends of the section assembly, thus completing the structure and providing means of attaching the radiator to the transformer tank. FIG. 2. Westinghouse Double Radiators Mounted Perpendicular to the Wall of a Form-Fit Tank APRIL, 1954

WESTINGHOUSE RADIATORS, FIG. 3. Radiator Section Showing Joints Formed With Outside Welds All joints are formed with outside edge welds which are reliable, easy to make, and permit a damaged joint to be repaired easily. Edges are trimmed and rounded for better paint adhesion. In order to produce an all over better paint job, each radiator is given a heavy phosphate coating. Then it is given one coat of primer, followed by two coats of finish paint. Each coat of paint is applied by the flow coat method and baked on in an infrared lamp oven. In flow coat painting, the paint is actually flowed over the surface and the surplus allowed to drain back into the main paint reservoir. This method insures complete and even paint coverage with a maximum thickness. The "hip roof" surfaces between sections and the sloping surfaces on the caps contain no flat surfaces where water can collect and cause rusting. The weld between the sections and the header is scalloped between sections so that any bead formed by the welding operation will be depressed, insuring that no water can collect at this point. INSTALLATION Receiving, Hanclling and Storing. The usual practice is to ship all radiators with all openings on the tank and radiators protected with blind flanges. The blind flanges and shipping gaskets are for shipment only and must be replaced by the gaskets supplied for permanent mounting. Sufficient gasket cement Mjj 7386 and cadmium plated bolts, nuts and lock washers are also furnished for permanent mounting. Important: Do not remove the blind flanges until ready to install the radiators. Dirt and moisture must be kept out of the radiators. 2 Unpacking. When unpacking, lifting or handling the radiators, care must be taken to prevent scratching the paint or damaging the radiator elements. An ample supply of grey touch-up paint is furnished to repaint any minor scratches. This paint should be applied as the radiators are being prepared for mounting. It is recommended that the radiators be lifted from the shipping crate using manila rope with sling spreaders to prevent damaging the radiator elements. Installing Single Radiators. It will be found most convenient to place the radiator across suitable supports when preparing it for mounting to the tank. First, remove the blind flanges from a radiator and clean the gasket grooves and flange faces of all paint, varnish, gasket material, etc. Second, remove the blind flanges from a set of valves on the transformer tank and clean the gasket grooves and flange faces. Apply a liberal coating of gasket cement Mjj 7386 to the gasket grooves, gaskets and mating surfaces of the radiator flange; again allow the cement to become tacky before mounting the radiator to the tank. Be sure the 3,4 inch studs are screwed tight against the shoulder on the stud before mounting the radiator. Now lift the prepared radiator by the lifting eye in the top header and swing it into position over the valves. Lifting of the radiator can be accomplished by using an overhead crane, an A-frame with block and tackle or by block and tackle to the station superstructure. The weight of a single radiator assembled with elbows is 540 pounds (6 feet length); 760 pounds (9 feet); 980 pounds (12 feet); 1120 pounds (14 feet). Installing Double Radiators. The procedure for mounting double radiators is essentially the same as for single radiators. The end spacer strips may cause some difficulty if they are not bolted into position before the radiator assembly is drawn down tightly to the tank. Caution must then be exercised to insure a good metal-to-metal contact between the header and the tank valve body. All other preparation and mounting details remain the same as for single mounted radiators. Filling of Radiators. To fill a radiator, turn the bottom valve to the open position as indicated on the operating arm and thus allow the liquid from the main tank to flow into the radiator. Secure the valve in this open position by means of the brass thumb screw. Next, open the top valve and allow the entrapped air to escape. Care must be taken that the terminal boards or bridge work of the transformer are not exposed above the liquid in this operation. If there is danger of exposing the terminal boards or bridge, liquid should be added to replace that required to fill each radiator. '

1NESTINGHOUSE RADIATORS ---- -L -46-n4-1-A After all radiators have been filled the normal liquid level should be restored as soon as possible or within a couple of hours. Radiator Removal. Should it become necessary to remove a radiator, first close the valves top and bottom. Lock the operating arm in the closed position with the brass thumb screw. Finger tightness will provide sufficient pressure to seat the valve. Next, drain the liquid from the radiator by removing the % inch drain plug from the bottom header and the % inch vent plug from the top. After the liquid has been removed from the radiator, proceed to dismantle. If the radiator is to be left off for any length of time the transformer valves should be gasketed and covered with blind flanges. The openings in the radiators should also be gasketed and flanged to keep out dirt and moisture. MAINTENANCE The only maintenance required for the radiators consists of repainting or touch up, to keep the surface free from rust. The radiator element wall is of a necessity thin in section for proper cooling, and being of steel construction, is susceptible to rust and possible rupture, unless protected by a good paint finish. The open element construction permits thorough cleaning of all surfaces for repaint or touch up. This ease of accessibility insures a better finish, longer radiator life and the least possible cost of maintenance. Standard finish paint for transformer tanks can be applied as touch-up paint. A special cleaning tool has been developed for removing rust spots or preparing the radiator surface for painting. For information about this tool, refer to Transformer Renewal Parts Catalog E-1-11. If the packing gland at the valve operating arm leaks and requires tightening it is necessary to remove the external arm (remove one screw) to get access to the gland nut. WESTINGHOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA. Printed in U.S.A.

'

FIG. 1. I. L. 46-735-lD DESCRIPTION INSTALLATION OPERATION INSTRUCTION S FORCED-AIR COOLING EQUIPMENT Bank Type Radiator Forced-Air Equipment. Westinghouse manufactures three types of forcedair cooling equipment for use on OA/FA (oilinsulated air-cooled, forced air-cooled) transformers: The bank type for radiators, the cooler tube type, and the portable type. The control equipment for all types is the same. An occasional inspection and greasing of motors is required after installation, as described later. Standard unit fan assemblies are furnished with 1/4 HP motors, single or three-phase. Single-phase motors are capacitor-start, capacitor-run, with SUPERSEDES I.L. 46-735-1 C UNIT FAN ASSEMBLY the capacitor mounted in a cylindrical case attached to the motor. Both single and three-phase motors are equipped with internally placed thermoguards for protection. Fan motors are wired in parallel; each motor is equipped with a polarized weatherproof attachment plug that can be disconnected from the supply line by turning counterclockwise and pulling out. Individual motors may be disconnected without disturbing the wiring in the supply line. Bank Type Radiator Forced-Air Equipment. The bank or multi-fan unit type forced-air equipment consists of a number of fans mounted on the side of the first of a group of radiators. Such an arrangement is shown in Fig. 1. The Westinghouse type radiator with its expanded cooling elements arranged in parallel rows provides a group of continuous ducts. The blast of air from the fans is directed through this duct system, thereby greatly increasing the normal convection characteristics. This type of forced-air equipment is applicable only to the Westinghouse radiator. The radiators must be mounted in alignment in banks to provide the proper duct system. Tube Cooler Type Forced-Air Equipment. The tube cooler type forced-air equipment consists of unit fans which are mounted near the bottom of the tank and under the tubular cooling elements. The air stream is directed upward so that the natural convection of both the tubes and tank wall is increased. Fig. 2 shows the arrangement of this type of auxiliary equipment. Portable Type Forced-Ail" Equipment. The portable type forced-air equipment consists of a complete fan and guard assembly mounted on a MAY, 1953

FORCED-AIR COOLING EQUIPMENT --- FIG. 2. Tube Cooler Type Forced-Air Equipment. fabricated steel stand. The unit is designed for use as an auxiliary source of forced-air equipment for miscellaneous types of apparatus. It may be used with effect for any type of radiator or cooling system that normally depends upon natural convection for heat dissipation. The air stream may be directed at any angle from downward to upward by adjusting the fan mounting. Fig. 3 shows this type of equipment. The unit may be placed in service as a temporary or permanent installation for either indoor or outdoor use. Standard automatic or manual control is available for Westinghouse transformer application. INSTALLATION It is usually necessary to remove radiators for shipment due to railroad clearance limitations. Before the radiators are assembled on the transformer, a careful study of the outline drawing and the actual job should be made. The outline shows the proper height for the location of banked fans. Banked fans are usually shipped properly located and attached to one or more radiators, depending upon the number of banks. Some shipments of assembled fans and motors are made with the fan and shaft braced to prevent vibration during shipment. Be sure all shipping straps or braces are removed, and that the fan turns freely when it is put into operation. 2 Mount the radiators and cooling fans, the control cabinet, conduit and connections as shown on the outline drawing. The hot oil thermometer (which also contains the thermal switch for activation of air blast fans) is sometimes removed for shipment. In this case it is necessary to install the thermometer in the well on the side wall of the transformer and connect the flexible alarm cable to the conduit or tank brace. An oil-tight well is provided to permit installation and removal of the thermometer without lowering the level of the oil inside the transformer tank. This is a close, smooth fitting well and requires no liquid between the bulb and the wall. See Fig. 4. The power connections to the panel are to be made as shown on the forced-air wiring diagram, a copy of which is included in the complete Transformer Instruction Book. Control Panel. The forced-air control panel is located in a weatherproof cabinet which is attached to the tank wall. There are two types of panels: Type A, (For Standardized Transformers). The 220 volt, 60 cycle, single-phase panel for auto- FIG. 3. Portable Type Forced-Air Equipment.

FORCED-AIR COOLING EQUIPMENT..:;I :..L:;: 4:;; 6,;;.; -7.:;35-1::;D ;; TEMPERATURE INDICATOR WITH THERMAL SWITCHES FIG. 4. CONDUIT BOX Thermometer and Well Construction. matic control of standardized transformers consists of a "De-ion" type AB line breaker, a Type N contactor and a flip-on switch. For manual control only the AB breaker is supplied, with provision for the future addition of the contactor and flip-on switch. Type B (For Non-Standard Application}. The 220 volt, 60 cycle, three-phase panel for automatic control consists of a "De-ion" type AB line breaker, a type N contactor, a flip-on switch and additional terminals. There are auxiliary contacts for lamp or alarm indication available at terminals on the panel. For manual control, the same panel is provided, the only difference being that the thermal switch is not supplied on the thermometer. OPERATION The thermal trip AB breaker provides short circuit protection and a means of de-energizing the panel for inspection and for maintenance. A thermally actuated switch included in the hot oil (or hot spot} thermometer controls the solenoid of a magnetic contactor which in turn starts and stops the fan motors in response to a change in oil (or hot spot) temperature. The circuit is energized from the load side of the panel power circuit. The manually operated flip-on switch provides a means of starting the fans independently of the position of the thermal switch. With the thermal switch in the closed position, the fans may be stopped by simply opening the AB breaker. Control by Bimetal Thermometer (Hot Oil Type). The bimetal type thermometer projects into the hot oil through a well and a fitting on the wall of the transformer case. A special set of contacts on the thermometer is supplied to control the fans, and is set to close at 60 C oil temperature. This setting is adjustable over a small range to accommodate the requirements of actual loading or for seasonal changes. See Instruction Leaflet pertaining to the thermometer for method of adjustment. A constant differential of soc is provided between the temperature of closing and opening of the thermal switch contacts to prevent too frequent stopping and starting of fans. Control by Bimetal Thermometer (Hot Spot Type). This is the same type of thermometer as the hot oil type, except that the well is surrounded by an auxiliary heating coil. Current proportional to the load on the power transformer is supplied to a heating coil from a current transformer. The heating coil and current transformer are designed to include compensation for duplicating the hot spot winding temperature of the transformer. Factory setting of the thermal switch on the thermometer is 7S C, with a soc differential between closing and opening temperatures. Adjustment of the 7S0 setting is possible, see Instruction Leaflet pertaining to the thermometer. Control by Special Thermostat. In special cases control is obtained from an individual thermostat with the bulb mounted through the cover of the transformer case and extending into the oil. This control may be from hot oil or hot spot temperatures. Contacts are set at the factory, are adjustable and are wired to a relay in the control cabinet for starting and stopping fans. Control by TRO Thermal Relay. This type of control operates from winding temperature by means of a TRO thermal relay. The relay is wallmounted in a well near the oil level. For details oi this type of control, see TRO relay instruction leaflet. MAINTENANCE Greasing. The motors have ball bearings designed to operate for long periods of time without greasing. Over-greasing a ball bearing assembly 3

FORCED-AIR COOLING EQUIPMENT --- is an invitation to trouble. It is recommended that the threaded plug at each bearing hub be removed at one to two-year intervals. Fill the plug hole with grease, press in firmly with the thumb and replace the plug. Do not use pressure guns that will force the grease past the bearings into the windings. A high grade of grease, such as Westinghouse grease '# 5612-2 should be used as a lubricant. This grease may be obtained from the Lima Motor Division, through the nearest Westinghouse Office. Painting. Good practice dictates that apparatus should be kept protected with paint. The entire air blast equipment, except the propeller, should be painted at regular intervals. Inspection. A regular thorough inspection should be made of the equipment to insure the best service. Renewal Parts. When ordering renewal parts, send a complete description of the particular part and the transformer serial number to the nearest Westinghouse Office. WESTING H 0 USE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA. Printed in U.S.A.

FIG. 1. I. L. 46-735-lE _ DESCRIPTION INSTALLATION OPERATION INSTRUCTION S FORCED-AIR COOLING EQUIPMENT Bank Type Radiator Forced-Air Equipment. Westinghouse manufactures three types of forcedair cooling equipment for use on OA/FA (oilinsulated air-cooled, forced air-cooled) transformers: The bank type for radiators, the cooler tube type, and the portable type. The control equipment for all types is the same. An occasional inspection and greasing of motors is required after installation, as described later. Standard unit fan assemblies are furnished with single or three-phase motors. Single-phase motors are capacitor-start, capacitor-run, with the capacitor SUPERSEDES I.L. 46-735-1 D UNIT FAN ASSEMBLY mounted in a cylindrical case attached to the motor. Both single and three-phase motors are equipped with internally placed thermoguards for protection. Fan motors are wired in parallel; each motor is equipped with a polarized weatherproof attachment plug that can be disconnected from the supply line by unscrewing counter-clockwise and pulling out. Individual motors may be disconnected without disturbing the wiring in the supply line. Rotation of the fan blade is counter-clockwise when looking at the motor from the lead end. Pipe plugs are omitted from the underside of each end cap to eliminate condensation inside the motor. Bank Type Radiator Forced-Air Equipment. The bank or multi-fan unit type forced-air equipment consists of a number of fans mounted on the side of the first of a group of radiators. Such an arrangement is shown in Fig. 1. The Westinghouse type radiator with its expanded cooling elements arranged in parallel rows provides a group of continuous ducts. The blast of air from the fans is directed through this duct system, thereby greatly increasing the normal convection characteristics. This type of forced-air equipment is applicable only to the Westinghouse radiator. The radiators must be mounted in alignment in banks to provide the proper duct system. Tube Cooler Type Forced-Air Equipment. The tube cooler type forced-air equipment consists of unit fans which are mounted near the bottom of the tank and under the tubular cooling elements. The air stream is directed upward so that the natural convection of both the tubes and tank wall is increased. Fig. 2 shows the arrangement of this type of auxiliary equipment. AUGUST, 1954

FORCED-AIR COOLING EQUIPMENT --- FIG. 2. Tube Cooler Type Forced-Air Equipment, Portable Type Forced-Air Equipment. The portable type forced-air equipment consists of a complete fan and guard assembly mounted on a fabricated steel stand. The unit is designed for use as an auxiliary source of forced-air equipment for miscellaneous types of apparatus. It may be used with effect for any type of radiator or cooling system that normally depends upon natural convection for heat dissipation. The air stream may be directed at any angle from downward to upward by adjusting the fan mounting. Fig. 3 shows this type of equipment. The unit may be placed in service as a temporary or permanent installation for either indoor or outdoor use. Standard automatic or manual control is available for Westinghouse transformer application. INSTALLATION It is usually necessary to remove radiators for shipment due to railroad clearance limitations. Before the radiators are assembled on the transformer, a careful study of the outline drawing and the actual job should be made. The outline shows the proper height for the location of banked fans. Banked fans are usually shipped properly located and attached to one or more radiators, depending upon the number of banks. 2 Some shipments of assembled fans and motors are made with the fan and shaft braced to prevent vibration during shipment. Be sure all shipping straps or braces are removed, and that the fan turns freely when it is put into operation. Mount the radiators and cooling fans, the control cabinet, conduit and connections as shown on the outline drawing. The hot oil thermometer (which also contains the thermal switch for activation of air blast fans) is sometimes removed for shipment. In this case it is necessary to install the thermometer in the well on the side wall of the transformer and connect the flexible alarm cable to the conduit or tank brace. An oil-tight well is provided to permit installation and removal of the thermometer without lowering the level of the oil inside the transformer tank. This is a close, smooth fitting well and requires no liquid between the bulb and the wall. See Fig. 4. The power connections to the panel are to be made as shown on the forced-air wiring diagram, a copy of which is included in the complete Transformer Instruction Book. FIG. 3. Portable Type, Forced-Air Equipment.

FORCED-AIR COOLING EQUIPMENT----------------- ' - L _._ 4 _ 6... -7.o.35..o-1;.. E TEMPERATURE INDICATOR WITH THERMAL: SW ITCHES FIG. 4. Thermometer and Well Construction. Control Panel. The forced air control panel is located in a weatherproof cabinet which is attached to the tank wall. Automatic control consists of a "De-ion" type AB line breaker, a type N contactor, a manual flip-on switch and additional terminals for alarm or lamp indication. For manual control only the AB breaker is supplied. OPERATION The thermal trip AB breaker provides short circuit protection and a means of de-energizing the panel for inspection and for maintenance. A thermally actuated switch included in the hot oil (or hot spot) thermometer controls the solenoid of a magnetic contactor which in turn starts and stops the fan motors in response to a change in oil (or hot spot) temperature. The circuit is energized from the load side of the panel power circuit. The manually operated flip-on switch provides a means of starting the fans independently of the position of the thermal switch. With the thermal switch in the closed position, the fans may be stopped by simply opening the AB breaker. Control by Bimetal Thermometer (Hot Oil Type). The bimetal type thermometer projects into the hot oil through a well and a fitting on the wall of the transformer case. A special set of contacts on the thermometer is supplied to control the fans, and is set to close at 60 C oil temperature. This setting is adjustable over a small range to accommodate the requirements of actual loading or for seasonal changes. See Instruction Leaflet pertaining to the thermometer for method of adjustment. A constant differential of soc is provided between the temperature of closing and opening of the thermal switch contacts to prevent too frequent stopping and starting of fans. Control by Bimetal Thermometer (Hot Spot Type). This is the same type of thermometer as the hot oil type, except that the well is surrounded by an auxiliary heating coil. Current proportional to the load on the power transformer is supplied to a heating coil from a current transformer. The heating coil and current transformer are designed to include compensation for duplicating the hot spot winding temperature of the transformer. Factory setting of the thermal switch on the thermometer is 7S C, with a soc differential between closing and opening temperatures. Adjustment of the 7S0 setting is possible, see Instruction Leaflet pertaining to the thermometer. Control by Special Thermostat. In special cases control is obtained from an individual thermostat with the bulb mounted through the cover of the transformer case and extending into the oil. This control may be from hot oil or hot spot temperatures. Contacts are set at the factory, are adjustable and are wired to a relay in the control cabinet for starting and stopping fans. Control by TRO Thermal Relay. This type of control operates from winding temperature by means of a TRO thermal relay. The relay is wallmounted in a well near the oil level. For details of this type of control, see TRO relay instruction leaflet. MAINTENANCE Greasing. The motors have ball bearings designed to operate for long periods of time without greasing. Over-greasing a ball bearing assembly is an invitation to trouble. It is recommended that the threaded plug at each bearing hub be removed at one to two-year intervals. Fill the plug hole with grease, press in firmly with the thumb and replace the plug. Do not use pressure guns that will force the grease past the bearings into the windings. A high grade of grease, such as Westinghouse grease fl, S612-2 should be used as a lubricant. This grease 3

FORCED-AIR COOLING EQUIPMENT --- may be obtained from the Lima Motor Division, through the nearest Westinghouse Office. Painting. Good practice dictates that apparatus should be kept protected with paint. The entire air blast equipment, except the propeller, should be painted at regular intervals. Inspection. A regular thorough inspection should be made of the equipment to insure the best service. Renewal Parts. When ordering renewal parts, send a complete description of the partigular part and the transformer serial number to the nearest Westinghouse Office. WESTINGHOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA. Printed in U.S.A.

FIG. I. I. L. 46-735-lF DESCRIPTION INSTALLATION OPERATION INSTRUCTIONS FORCED-AIR COOLING EQUIPMENT Bank Type Radiator Forced-Air Equipment Westinghouse manufactures three types of forcedair cooling equipment for use on OA/F A (oilinsulated air-cooled, forced air-cooled) transformers: The bank type for radiators, the cooler tube type, and the portable type. The control equipment for all types is the same. An occasional inspection and greasing of motors is required after installation, as described later. Standard unit fan assemblies are furnished with single or three-phase motors. Single-phase motors are capacitor-start, capacitor-run, with the capacitor SUPERSEDES I.L. 46-735-1 E UNIT FAN ASSEMBLY mounted in a cylindrical case attached to the motor. Both single and three-phase motors are equipped with internally placed thermoguards for protection. Fan motors are wired in parallel; each motor is equipped with a polarized weatherproof attachment plug that can be disconnected from the supply line by unscrewing counter-clockwise and pulling out. Individual motors may be disconnected without disturbing the wiring in the supply line. Rotation of the fan blade is counter-clockwise when looking at the motor from the lead end. Pipe plugs are omitted from the underside of each end cap to eliminate condensation inside the motor. Bank Type Radiator Forced-Air Equipment. The bank or multi-fan unit type forced-air equipment consists of a number of fans mounted on the side of the first of a group of radiators. Such an arrangement is shown in Fig. 1. The Westinghouse type radiator with its expanded cooling elements arranged in parallel rows provides a group of continuous ducts. The blast of air from the fans is directed through this duct system, thereby greatly increasing the normal convection characteristics. This type of forced-air equipment is applicable only to the Westinghouse radiator. The radiators must be mounted in alignment in banks to provide the proper duct system. Tube Cooler Type Forced-Air Equipment. The tube cooler type forced-air equipment consists of unit fans which are mounted near the bottom of the tank and under the tubular cooling elements. The air stream is directed upward so that the natural convection of both the tubes and tank wall is increased. Fig. 2 shows the arrangement of this type of auxiliary equipment. JUNE, 1960

FORCED-AIR COOLING EQUIPMENT --- FIG. 2. Tube Cooler Type Forced-Air Equipment. Portable Type Forced-Air Equipment. The portable type forced-air equipment consists of a complete fan and guard assembly mounted on a fabricated steel stand. The unit is designed for use as an auxiliary source of forced-air equipment for miscellaneous types of apparatus. It may be used with effect for any type of radiator or cooling system that normally depends upon natural convection for heat dissipation. The air stream may be directed at any angle from downward to upward by adjusting the fan mounting. Fig. 3 shows this type of equipment. The unit may be placed in service as a temporary or permanent installation for either indoor or outdoor use. Standard automatic or manual control is available for Westinghouse transformer application. INSTALLATION It is usually necessary to remove radiators for shipment due to railroad clearance limitations. Before the radiators are assembled on the transformer, a careful study of the outline drawing and the actual job should be made. The outline shows the proper height for the location of banked fans. Banked fans are usually shipped properly located and attached to one or more radiators, depending upon the number of banks. 2 Some shipments of assembled fans and motors are made with the fan and shaft braced to prevent vibration during shipment. Be sure all shipping straps or braces are removed, and that the fan turns freely when it is put into operation. Mount the radiators and cooling fans, the control cabinet, conduit and connections as shown on the outline drawing. The hot oil thermometer (which also contains the thermal switch for activation of air blast fans) is sometimes removed for shipment. In this case it is necessary to install the thermometer in the well on the side wall of the transformer and connect the flexible alarm cable to the conduit or tank brace. An oil-tight well is provided to permit installation and removal of the thermometer without lowering the level of the oil inside the transformer tank. This is a close, smooth fitting well and requires no liquid between the bulb and the wall. See Fig. 4. The power connections to the panel are to be made as shown on the forced-air wiring diagram, a copy of which is included in the complete Transformer Instruction Book. I FIG. 3. Portable Type Forced-Air Equipment

FORCED-AIR COOLING EQUIPMENT.. I--L --4-.6--735;.;...; -1-.F TEMPERATURE INDICATOR WITH THERMAL SWITCHES L----"'" conouit BOX FIG. 4. Thermometer and Well Construction Control Panel. The forced air control panel is located in a weatherproof cabinet which is attached to the tank wall. Automatic control consists of a "De-ion" type AB line breaker, a type N contactor, a manual flip-on switch and additional terminals for alarm or lamp indication. For manual control only the AB breaker is supplied. OPERATION The thermal trip AB breaker provides short circuit protection and a means of de-energizing the panel for inspection and for maintenance. A thermally actuated switch included in the hot oil (or hot spot) thermometer controls the solenoid of a magnetic contactor which in turn starts and stops the fan motors in response to a change in oil (or hot spot) temperature. The circuit is energized from the load side of the panel power circuit. The manually operated flip-on switch provides a means of starting the fans independently of the position of the thermal switch. With the thermal switch in the closed position, the fans may be stopped by simply opening the AB breaker. Control by Bimetal Thermometer (Hot Oil Type). The bimetal type thermometer projects into the hot oil through a well and a fitting on the wall of the transformer case. A special set of contacts on the thermometer is supplied to control the fans, and is set to close at 60 C oil temperature. This setting is adjustable over a small range to accommodate the requirements of actual loading or for seasonal changes. See Instruction Leaflet pertaining to the thermometer for method of adjustment. A constant differential of soc is provided between the temperature of closing and opening of the thermal switch contacts to prevent too frequent stopping and starting of fans. Control by Bimetal Thermometer (Hot Spot Type). This is the same type of thermometer as the hot oil type, except that the well is surrounded by an auxiliary heating coil. Current proportional to the load on the power transformer is supplied to a heating coil from a current transformer. The heating coil and current transformer are designed to include compensation for duplicating the hot spot winding temperature of the transformer. Factory setting of the thermal switch on the thermometer is 7S C, with a soc differential between closing and opening temperatures. Adjustment of the 75 setting is possible, see Instruction Leaflet pertaining to the thermometer. Control by Special Thermostat. In special cases control is obtained from an individual thermostat with the bulb mounted through the cover of the transformer case and extending into the oil. This control may be from hot oil or hot spot temperatures. Contacts are set at the factory, are adjustable and are wired to a relay in the control cabinet for starting and stopping fans. Control by TRO Thermal Relay. This type of control operates from winding temperature by means of a THO thermal relay. The relay is wallmounted in a well near the oil level. For details of this type of control, see THO relay instruction leaflet. MAINTENANCE Greasing. The motors have ball bearings designed to operate for long periods of time without greasing. Overgreasing a ball bearing assembly is an invitation to trouble. Motors Without Pressure Grease Fittings. It is recommended that the threaded plug at each bearing hub be removed at one to two-year intervals. Fill the plug hole with grease, press in firmly with the thumb and replace the plug. Do not use pressure guns that will force the grease past the bearings into the windings. 3

FORCED-AIR COOLING EQUIPMENT --- Motors With Pressure Grease Fittings. The motor is designed with a pressure and relief fitting at both bearings. They have ball bearings with a seal on the winding side of the motor and a shield on the opposite side. These bearings should be greased at one to two-year intervals using only the necessary pressure to show grease coming from the relief fitting. A high grade of grease, such as Westinghouse Grease fl, 5612-2 should be used as a lubricant for either motor. This grease can be obtained from Lima Motor Division through the nearest Westinghouse Office. Painting. Good practice dictates that apparatus should be kept protected with paint. The entire air blast equipment, except the propeller, should be painted at regular intervals. Inspection. A regular thorough inspection should be made of the equipment to insure the best service. Renewal Parts. When ordering renewal parts, send a complete description of the particular part and the transformer serial number to the nearest Westinghouse Office. WESTING HOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA. Printed in U.S.A.