Up to 10 zones. Spray directly into the space for high ceiling applications (approximately 30ft/9m)

Similar documents
Custom modular design to fit any application

Since 1976, Neptronic has been committed to

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

Since 1976, Neptronic has been committed to

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

STEAM TO STEAM HUMIDIFIER

RESISTIVE STEAM HUMIDIFIER

STEAM TO STEAM HUMIDIFIER

Advantages. Evaporation Chamber. Evaporate water, not money! No tools required. Limits lifting and simplifies handling

CONDAIR ME. In-duct evaporative humidifier and cooler Very low energy operation. Humidification and Evaporative Cooling

PART 1 - GENERAL 1.1 WORK INCLUDED

The SKD direct steam injection system uses low pressure steam from an in-house boiler to humidify the air.

JETSPRAY. Compressed air and water spray humidifier Guaranteed drip free. Humidification and Evaporative Cooling

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

SKG Advantages. Typical Applications. Typical Installation

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

SKH High-Pressure Atomizer

PART 1 - GENERAL 1.1 WORK INCLUDED

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall

humifog Pressurized water humidifi ers

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Tried, true, and trusted for over 40 years. EL Series Electrode Steam Humidifier. Humidification and Evaporative Cooling. humidity.

The SK300 humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

The SK300 humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

INTELLIGENT SOLUTIONS FOR ADIABATIC COOLING IN DATA CENTERS

EvaPack SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

HIGH-PRESSURE ATOMIZING SYSTEM. Humidification and adiabatic cooling. Energy efficient Reduces cooling load Multiple zone capabilities

Cool, Clean and Comfortable Nortec HP-Series. Adiabatic In-Duct High Pressure Humidification System... Simply Awesome

Water atomiser through compressed air

Getting Rid of Scale. Nortec RS Series Steam humidifier with patented scale management. Humidification and Evaporative Cooling

EVAPACK SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

FORMULA. Rotary screw compressors. kw 5,5-7, , bar

INTELLIGENT HUMIDIFICATION. Two adiabatic humidification methods intelligently combined Condair DL. Humidification and evaporative cooling

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

Atomizing Nozzle Humidifiers. Designed for Air Handling Systems, and Manufacturers, Processors and Distributors of Humidity Sensitive Products.

Double Intelligence Two adiabatic humidification methods intelligently combined. Humidification and Evaporative Cooling. humidity.

FOGGING & HUMIDIFICATION PAPER STORAGE TEXTILE MILLS LIQUID STORAGE TANKS AIR DUCTS PRODUCE STORAGE ROOMS GREENHOUSES HATCHERIES CONCRETE PIPE CURING

FOGGING & HUMIDIFICATION PAPER STORAGE TEXTILE MILLS LIQUID STORAGE TANKS AIR DUCTS PRODUCE STORAGE ROOMS GREENHOUSES HATCHERIES CONCRETE PIPE CURING

humisonic direct Climate Business Unit Adiabatic System Platform

Rotary screw compressors

Key benefits. Why Condair Dual2?

The SKE humidifier generates mineral free, odorless, sterile steam without the replacement cost associated with electrode cylinders.

Humidification Systems Product Guide

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Flexible & Innovative. Cooling Solutions

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

Rotary screw compressors

Evaporative Humidifier SKV Series

RSW D / RSWF D water-injected, with direct drive

VENTURI NOZZLE SYSYTEM Specification Sheets ALL STAINLESS STEEL COMPRESSED AIR NOZZLE HUMIDIFIERS. With ON/OFF or Proportional Controls

OPERATION AND MAINTENANCE MANUAL. Electrode Steam Humidifier Nortec EL Series

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

High pressure water atomizing humidifier 30.3 (770) Energy saving! 32 (810) 1.5 (40) max 1 (24) 14 (355) 1 (22,6) 1.5 (38) .

SEQUENCE OF OPERATIONS

A SYSTEM FOR HIGH-PERFORMANCE HUMIDIFICATION

QUALITY STEAM. Electrode Steam Humidifier Condair EL. Humidification and evaporative cooling

Humidity matters! CAREL solutions for your humidification needs. carel.com. air humidification systems. isothermal and adiabathic humidification

High-Pressure Atomizing System

NH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

2012 Product Handbook

READ AND SAVE THESE INSTRUCTIONS

Help. Help Software Tutorial. Building a Load Sizing Project with an NH-EL Humidifier and CSD Distributor.

heatersteam unprecedented precision and reliability

TR 0603mc U Solar Controller

electric steam gas steam atomizing nozzles high pressure nozzles evaporative steam injection steam exchange 2011 Product Handbook

StableClimate Stability Chambers

Colt CoolStream Adiabatic Cooling & Ventilation System

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

Humidifier CERTO. How today s room humidifiers work

Direct Room Humidifiers. Humidification and Evaporative Cooling. humidity.com

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Siemens RDY2000BN. Start Up Guide

& EC Fan Retrofit Kit

OPTIMIZING PERFORMANCE IN SPRAY OPERATIONS

mc multizone simple and robust, ideal for large industrial environments

LE Series. Electrode Steam Humidifiers

PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM

State of the Art. Exceptional Reliability

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Cultivator & Hybrid Cultivator

ACMVTECH HIGH EFFICIENCY UNITARY AHU

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

EN 1508 OPERATION MANUAL. Steam humidifier Condair RS. Humidification and Evaporative Cooling

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

NH-EL. The evolution of the industry s most trusted electrode steam humidifier NH SERIES. humidity.com

TrilliumSeries. Condenser

EN aquatech.piovan.com

air humidification systems adiabatic humidification humifog multizone high pressure atomised water humidifier carel.com

HumidiClean Series HC-6000 Humidifier Revolutionary ionic bed technology that carries a lot of weight

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

IntrCooll. Cool large buildings at 80% lower running costs

BAC-4000 Series AppStat

New standard in compressed air treatment, providing Energy Savings up to 99%

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Reliability & efficiency without compromise

Transcription:

The SKH pumps water at high pressure through a series of nozzles to produce a fine mist. By way of the adiabatic process, the SKH uses energy (heat) from the surrounding air to evaporate the fine mist (water droplets). This evaporative cooling/humidification process provides a very low energy impact with power consumption values of 2 HP to 10 HP (1.5 kw to 7.5 kw), which is less than other technologies of equivalent capacity, such as compressed air. Up to 21.5 F (12 C) of free cooling Close control humidity Uses energy from ambient air Up to 10 zones View and control from any zone Fast and easy maintenance Typical Applications With capacities from 66 to 4,738 lb/hr (30 to 2,108 kg/h), multi-zone capability and its low energy impact, the SKH High Pressure Humidifier is ideal for applications such as: 4Commercial Space 4Wood Processing 4Paint Spray Booths 4Greenhouses 4Textile Industry Typical Installation (or "Distribution") Custom nozzle racks, make it ideal for use in AHUs 1 to 4 stages for sequential control 1 st stage modulates for close control Droplet separator if required Spray directly into the space for high ceiling applications (approximately 30ft/9m) Flexible nylon high-pressure hoses or hydraulic high-pressure hoses With stainless steel quick connect fittings Spray directly into the space with a fan (MDU: Mist Distribution Unit) for low ceiling applications (minimum 15ft/4.6m) Horizontal air flow assists in the evaporation process

System Overview Nozzles Anti-drip nozzles produce droplets of less than 20µm. Variable Frequency Drive (VFD) Regulates motor and pump RPMs to ensure greater energy savings and longer pump life. Intelligent Controller Networkable (BACnet MS/TP), field configurable controller manages sequences of operation and provides close control for up to 4 stages and 10 zones. Pressure Regulator and Gauge Water inlet pressure regulator and gauge to adjust the appropriate water inlet pressure. Pre-filter and Silver Ion Cartridge Water pre-treated with 5µm pre-filter and antibacterial silver ions prevent microbial growth. High Pressure Water Pump High efficiency, water cooled axial piston pump (maintenance free). Pump 4Very high efficiency, small and compact 4All stainless steel design 4Water cooled 4Axial piston pump 4Maintenance free (no oil to change) High Pressure Water Outlet Ranges varying from 66 to 4,738 lb/h (30 to 2,108 kg/h) per pump station depending on model. 4Extreme recirculation capability (up to 90%) without overheating 4Fulfils most stringent hygiene requirements, such as VDI 6022 Controller 4Microprocessor based, field configurable controller 4Real-time clock with flexible scheduler 4Simple viewing and exporting of trending log and alarm log BACnet MS/TP Communication 4Select MAC address via menu or network 4BACnet scheduler (up to 6 events) 4Firmware upgradeable via network 4 In-field firmware upgradeable via micro SD card 4LCD (128 x 64) with context-driven, userfriendly menu 4COV (change of value) 4Automatic baud rate detection 4Automatic device instance configuration

Multi-Zone System A single pumping station can be used to supply pressurized water to up to 10 zones. The master controller, located in the master pumping station, communicates with each zone controller via a proprietary network. The zone controller communicates its local readings and status to the master controller as well as to the local wallmount user interface. Using the data received, the master controller manages the distribution and atomization system to maintain close control humidity. 4Up to 10 zones 44 sequential stages per zone including 1 proportional stage. 4Connect to any zone with a computer to view and control the system 4BMS Integration via BACnet MS/TP @ 9600, 19200, 38400, or 76800 bps Maintain optimal humidity levels in every zone, with only one unit. Each zone has an independent humidistat Zone 1: Storage 40-45% RH Mechanical Room SKH Humidifier Zone 2: Processing 50-55% RH Zone 3: Assembly 50-60% RH Zone 4: Packing & Shipping 40-45% RH Zone 5: Offices 35-40% RH

Remote System Control 4Each SKH unit has an integrated system controller that manages all sequences of operation for each zone. 4Unique to Neptronic, you can tap into the system directly from within the zone by connecting to the zone's thermostat/humidistat. 4With its BACnet MS/TP communication, integrate the system with your Building Management System (BMS) Building Managenment System Zone 1: Storage 40-45% RH Zone 2: Processing 50-55% RH Zone 3: Assembly 50-60% RH Zone 4: Packing & Shipping 40-45% RH Connect directly to any zone Zone 5: Offices 35-40% RH Models and Capacities Model Capacity Motor lb/h kg/h HP kw SKH100 66-660 30-300 2 1.5 SKH200 141-1126 64-512 3 2.25 SKH300 231-1454 105-661 5 3.75 SKH600 453-2343 206-1065 7.5 5.6 SKH900 585-3645 266-1657 10 7.5 SKH1200 805-4738 366-2108 10 7.5

Hygienic and Safe 4RO water recommended to - increase hygienic performance - minimize maintenance - avoid nozzle blockage - eliminate the introduction of dust into the space - eliminate use of biocide and chemical disinfectants 4The systems contain no standing water 4Automatically activated rinsing of the system prevents standstill contamination, and this without any downtime 4System design ensures only inert materials come in contact with the water 4Auto reduction of output in case air absorption capacity is lower than design condition 4Water pre-treated with 5μm pre-filter and anti-bacterial silver ions prevent microbial growth 1) Silver ions break through the cell wall 5μm Pre-filter Silver ions 2) Silver ions disrupt respiration of the microbe 3) Silver ions attach to the DNA of the microbe to stop cell replication Energy Efficient 4By combining a high pressure water pump with the adiabatic process, the SKH uses less energy than other humidifier types that require more expensive air compressors to evaporate the water. 4Misting without expensive compressed air saves on energy costs, compressor maintenance and installation. 4Humidifying in the winter reduces heating costs. Providing free cooling in the summer reduces cooling costs. 4VFD regulates pump performance to best match the current humidity demand, which ensures greater energy savings. Fast and Easy to Service and Install 4The master controller displays all maintenance intervals and status messages via a multi-functional display screen. An indication also appears on the wall-mount user interface. Operating and fault signals can be integrated into your Building Management System (BMS). 4Monitoring and troubleshooting can be done remotely via the BACnet network. 4The water pump is water cooled and lubricated and therefore maintenance is further minimized since there is no oil to change in the pump. 4The nozzle rack is custom made to fit duct or AHU dimensions 4The SKH system features quick connects between the nozzle rack, or MDU and pump station.

SKH-EBL-180727