Company Acme HVAC Inc. Customer James Allen Preparer J White Address 3652 Shady LaneAnywhere, Earth Phone

Similar documents
UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

Commercial load calculator instructions (all measurements are imperial)

Air System Sizing Summary for AHU/CU-1 Project Name: Wilton Manors Fire Station#16 06/26/2016 Prepared by: L.N.I.

MANUAL J/S Summary One summary sheet for each system

Air System Sizing Summary for Lobby System Project Name: Existing Lobby 04/04/2005 Prepared by: psuae

Controlling Indoor Humidity in High Performance Homes. Danny Gough, Energy Solutions, LP

A GUIDE TO PASSING THE HVAC EXAM

IMPORTANT STUFF. Optional references

A/C Cooling Load calculation and measurement

Residential HVAC System Design

A GUIDE TO PASSING THE HVAC EXAM COVERS MANUALS J.D. AND N. INT. MECHANICAL CODE INTERNATIONAL FUEL GAS CODE INTERNATIONAL ENERGY CODE BUSINESS

Fundamentals of Psychrometrics. By James L. Murphy, Colorado Building Environments Sales Engineer

Welcome. High Performance Mechanicals for Houses That Work. Energy Design Conference - Duluth, MN. February 21 st, 2018

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

INSTALLATION INSTRUCTIONS

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM

Reviewing HVAC Designs for Compliance with ACCA Manual S

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Standards and Guidelines. Presented by: Aric Murray December 12, 2014

RESNET Rating Field Inspector Field Evaluation Form

CHAPTER IV AIR DISTRIBUTION AND BALANCE

ENERGY STAR Qualified Homes

UPGRADES. [Energy Efficiency] Base Points

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series


RESNET HERS Rater Sample Test Questions 2

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

97.501B. Prepared by: (415) Sponsored By: Final Report. Author: Presented at: ASHRAE. Meeting SF Me!

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

The evil that men do lives after them; the good is oft interred with their bones.

In the past, contractors sized heating and cooling systems GETTING HVAC RIGHT

Ventilation for New Low-Rise Residential Buildings July 20, 2015

Why Doesn t My HVAC System Work?

Residential Energy Use ME 416/516

FirstEnergy Program Overview

New Jersey Home Performance with ENERGY STAR Home Performance Audit/ Software Data Collection-2011

HVAC Systems What the Rater Needs to Know in the Field CALCS-PLUS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Residential Heating and Cooling Loads

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

REQUIRED CONTRACT DETAIL. $2, , Direct DC Fuel Cell Power System, Stationary PACE Power output < 40 kw

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

TECHNICAL SPECIFICATIONS

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

PACKAGE AIR CONDITIONER

FG7T (C and L Series)

ACCA Manual J Load Calculations

C13-Series Engineering Guide

August 15, 2013 Page 1 of 19

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Deemed Savings, Installation & Efficiency Standards

IES Whole-Building Energy Model Baseline Energy Model Input/ Output Report. East Liberty Presbyterian Church East Liberty Presbyterian Church

ENERGY COST AND FEATURE REPORT

R4H4. Product Specifications

INDEX. ADDITIONS AND ALTERATIONS Defined Requirements ADMINISTRATION AND ENFORCEMENT... Chapter 1 AIR ECONOMIZERS

2009 Washington State Energy Code Residential Sections

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

Duct Design and Installation

wattsmart New Homes Contractor-Certified HVAC Quality Assurance (HVAC-QI)

R4H4. Product Specifications

COOLING LOAD CALCULATION SHEET

Unit Features & Benefits RQPM/RQRM Series

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Chilled Beam and Radiant Cooling Basics. Salt Lake City, UT ASHRAE Chapter December 2013 Nick Searle

Effects of Kitchen Ventilation on Residential Dwellings

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

ENGINEERING. Edition No. 13 October 2002

HOME PERFORMANCE ENERGY ANALYSIS

90% Design Submittal Mechnical Equipment Calculations Parking Garage CDRL

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Worksheet for Small Commercial Air System Design

RG7D 1-Stage Heat Series

RSG16**S1M. Split System Air Conditioner 16 SEER

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

PhEn-602 Pharmaceutical Facility Design. Notes #7 J. Manfredi

ENERGY STAR v3.0 HVAC Checklists

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

TDSHS Air Change Requirements and the Basics of Psychrometrics. Presented by: Aric Murray December 06, 2013

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

303 Garibaldi Ave, Roseto, PA Phone: Fax: Web: License: PA007413

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

ApacheHVAC User Guide Part F: Loads Analysis and Reporting Tools

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

C+ %RH R22. CUH Series Cooling capacity range kw. Ceiling Concealled Type Air Conditioner For Precision Temperature & Humidity Controls

Uniform Dwelling Code 2017 Updates SPS 323

Richard Hiles ClimateMaster

Transcription:

Company Acme HVAC Inc. Customer James Allen Preparer J White Address 3652 Shady LaneAnywhere, Earth Phone 252-555-7493 Phone 555-576-3764 Date 12/9/10 This HVAC load calculation has been performed using sound engineering principles as prescribed by Manual J seventh and eighth abridged editions and ASHRAE Fundamentals. Duct sizing has been performed as prescribed by Manual D. 1. Design Conditions Indoor Outdoor Temp. Diff. Winter 70 20 50 Summer 75 92 17 2. How would you describe the summer humidity in your area? Moderately Humid 40 3. Volume of building (cubic feet) 12992 4. How tight is the house? Average-over 1500 Sq. Ft. 0 5. Number of occupants 4 6. Overhang Characteristics (this section optional) East West S/SE/SW Distance of overhang from top of window (Ft.) 0 0 0.5 Length of overhang 0 0 1.5 7. Solar gain through glasses Facing Total area-sq. Type of glass HTM Linear ft. Unshaded Shaded BTUH Ft. N/Shaded 65 Double 24 below OH 65 NE/NW 0 0 South 60 Double 40 9 29 30 1176 SE/SW 0 0 0 0 0 0 East 24 Double 75 0 24 0 1800 West 22 Double 75 0 22 0 1650 Total North and Shaded 95 2294 Skylight 0 150 0 Total solar gain 6920 Adjust for tinted or reflective window coating NO 1 6920 8. Ducts/Pipes Location Enclosed in unconditioned space 0.7 Insulation R-8 0.08 Duct Loss/Gain 0.056

9. Load Calculation Elements of Load Insulation Area/lin.ft. U-value BTUH Loss BTUH Gain Gross Wall 1376 sq. ft. Glass Solar Gain 6920 Glass 1 Trpl or Low-E 171 sq. ft. 0.42 3591 Glass 2 0 sq. ft. 0 0 Skylights 0 sq. ft. 0 0 Doors Insulated or Storm 33 sq. ft. 0.4 660 224 Net walls R-11 1172 sq. ft. 0.08 4688 1593 Ceilings R-19 1624 sq. ft. 0.055 4466 4019 Floors R-11 1624 sq. ft. 0.08 3248 0 Open Floors 0 sq. ft. 0 0 0 Slab Floors 0 lin. ft. 0 0 0 Infiltration 8336 2834 People 1200 Appliances btuh 1200 Sub total 24989 17992 Ducts 1399 1007 Sub total 26388 19000 Latent load 4122 TOTAL BTUH 26388 23122 Basement Calculation Elements of Load Insulation Area/lin.ft. U-value BTUH Loss BTUH Gain Walls above grade 0 Glass 0 0 0 North 0 0 0 South 0 0 0 East 0 0 0 West 0 0 0 Doors 0 0 0 0 Net walls above 0 0 0 0 Walls below grade 0 0 0 0 Ceilings 0 0 0 0 Floors 0 0.024 0 0 Infiltration 0 0 0 Number of people 0 300 0 Appliances 0 Sub total 0 0 Latent load 0 Total BTUH 0 0 Total whole house load including basement 26388 23122

Energy Cost Analysis Heat Loss 26388 Heating degree days (from map) 3300 Heat Gain 23122 Cooling degree days (from map) 1500 Summer Design Temp. 92 Summer Design Temp. Diff. 17 Winter Design Temp. 20 Winter Design Temp. Diff. 50 System #1 (less efficient) Efficiency Fuel Cost Price Air Conditioning 10 0.14 $431 Heating PROPANE GAS 0.8 2.25 $1284 Total annual operating cost of system 1 $1716 System #2 (more efficient) Efficiency Fuel Cost Price Air Conditioning 15 0.14 $287 Heating HEAT PUMP 8.5 0.14 $589 Total annual operating cost of system 2 $876 Payback and ROI Cost of new or more efficient system $7650 Cost of less efficient system $0 Rebates or credits $1500 Net or Additional investment $6150 Yearly savings $839 Payback (years) 7.3 Return on Investment (ROI) 13.7%

Total Heat Loss 25927 Total Heat Gain 22547 System CFM 800 Room name Kitch en din room m bebro om m bath bath 2 bedro om 2 office bedro om 1 Gross Wall Sq. Ft. 224 128 72 208 40 40 200 112 North Windows Sq. Ft. 10 15 15 15 10 0 0 0 NE/NW Windows Sq. Ft. 0 0 0 0 0 0 0 0 South Windows Sq. Ft. 0 0 0 0 0 0 12 24 SE/SW Windows Sq. Ft. 0 0 0 0 0 0 0 0 East Windows Sq. Ft. 0 0 0 12 0 0 12 0 West Windows Sq. Ft. 10 0 0 0 0 0 0 0 Skylight Sq. Ft. 0 0 0 0 0 0 0 0 Doors Sq. Ft. 11 0 0 0 0 0 0 0 Net Walls Sq. Ft. 193 113 57 181 30 40 176 88 Ceiling Sq. Ft. 196 224 146 168 50 70 132 196 Floor-crawl Sq. Ft. 196 224 146 168 50 70 132 196 Floor-open Sq. Ft. 0 0 0 0 0 0 0 0 Floor-slab Lin.. Ft. 0 0 0 0 0 0 0 0 Volume Cu.Ft. 1568 1792 1168 1344 400 560 1056 1568 People Number 0 0 1 1 0 0 1 1 Appliance BTUH 1200 0 0 0 0 0 0 0 Duct Loss 187 166 111 165 46 47 140 156 Duct Gain 187 81 75 140 27 19 138 123 Latent 497 568 370 426 126 177 335 497 Heat Loss 3536 3147 2097 3116 870 899 2653 2949 Heat Gain 4039 2109 1800 3082 646 547 2950 2828 Cooling CFM 143 74 63 109 22 19 104 100 Heating CFM 109 97 64 96 26 27 81 91

Room name liv room Gross Wall Sq. Ft. 352 North Windows Sq. Ft. 0 NE/NW Windows Sq. Ft. 0 South Windows Sq. Ft. 24 SE/SW Windows Sq. Ft. 0 East Windows Sq. Ft. 0 West Windows Sq. Ft. 0 Skylight Sq. Ft. 0 Doors Sq. Ft. 21 Net Walls Sq. Ft. 307 Ceiling Sq. Ft. 420 Floor-crawl Sq. Ft. 420 Floor-open Sq. Ft. 0 Floor-slab Lin.. Ft. 0 Volume Cu.Ft. 3360 People Number 0 Appliance BTUH 0 Duct Loss 352 Duct Gain 184 Latent 1066 Heat Loss 6655 Heat Gain 4543 Cooling CFM 161 Heating CFM 205

Total measured length of duct 64 Total equivalent length of fittings 182 Available static pressure for duct 0.19 Friction loss 0.077 Room name No. outlets Outlet CFM Room CFM Duct diam. Air vel. Supply trunk 0 16 573 1st section Supply trunk 408 12 519 2nd section Supply trunk 0 2 0 3rd section Return trunk 0 16 573 1st section Return trunk 0 2 0 2nd section Return trunk 0 2 0 3rd section Kitchen 1 109 109 7 408 din room 1 97 97 7 363 bedroom 1 1 64 64 6 329 m bebroom 1 96 96 7 360 m bath 1 26 26 4 307 bath 2 1 27 27 4 318 bedroom 2 1 81 81 7 306 office 1 91 91 7 340 liv room 2 102 205 7 384

Equipment selection as per Manual S Indoor Outdoor Winter 70 20 Summer 75 92 ID design RH 50%, 63F WB altitude 1500 BTUH Nom. tons Total heat loss 26388 Total heat gain 23122 1.9 Sensible heat gain 19000 Latent heat gain 4122 sensible/total ratio 0 target cooling TD 19 approx. cooling CFM 909 Equipment size limits (BTUH output) Air conditioner / heat pump Furnance Boiler cool climate heat climate output output Maximum size 26591 28903 36944 36944 Selected size Ok Ok Ok Ok Manufacturer's Equipment Specifications Equipment Manufacturer Model No BTUH output (heating) furnance acme 9040 36000 Clg. Capacity @ OD design temp. boiler 0 total sensible latent heat pump N/A 0 0 0 air conditioner 23800 19500 4300 evaporator acme AC030 air handler Total capacity with altitude correction 33840 23264 19061 4203

Blower CFM (heating) 700 Blower CFM (cooling) 900 Temp rise (heating) 46 Temp drop (cooling) 19 Available static pressure for duct system Supplemental heat needed for heat pump Blower ext. static press. 0.5 HP capacity @ 47F 0 coil pressure drop 0.1 HP capacity @ 17F 0 filter pressure drop 0.15 HP capacity @ ODDT 0 register pressure drop 0.03 BTUH supplemental heat 0 grille pressure drop 0.03 KW supplemental heat 0 other 0.05 other 0 other 0 Available SP for duct 0.14