Maluna Unhinged vs Yeti Tundra Thermal Performance Comparison January 2017

Similar documents
Oral Syringe Product Stability &

quick start guide Product features RF195/197** RF215/217** Moving Tray Surround Multi Flow Twin Cooling System Digital Display & Temperature Control

SERVICE INSTRUCTION. DYNAMIC COOLING with 0 zone REFRIGERATION. Fridge/freezer with. Publication number

quick start guide Product features RF195/197** RF215/217** Moving Tray Surround Multi Flow Twin Cooling System Digital Display & Temperature Control

quick start guide Product features RF4287HA English Surround Multi Flow

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

quick start guide Product features RFG298HD* RFG297HD* RFG296HD* RFG29PHD* RFG29THD* English Surround Multi Flow 16" Pizza Corner Twin Cooling System

quick start guide RFG237AA RFG238AA

Warm-a-Matic Hot Cup. Team Yamagochi International. Michael Brupbacher, Tara Feller, Ian Levy, Craig Sobin, Alex Vanarelli

quick start guide Product features English RFG293HA Surround Multi Flow Secure Auto Close Door System Twin Cooling System Easy Handle System

Sustainable Techniques in Refrigerated Space

BACK BAR REFRIGERATION SERIES

FRIDGE FREEZERS BUILT BETTER BUILT TOUGHER BUILT SMARTER. Serious performance, quality and strength...the smartest choice in portable refrigeration!

LIQUID CHILLING PRODUCTS 2019 PRODUCT CATALOG

Using Adaptive Defrost Control Technology to Improve Energy Savings in the Food Service Industry.

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

GUIDE BOOK FROSTIE FROST FIGHTING CONTROLLER

GLYCOL CHILLER INSTRUCTIONS IMPORTANT: BEFORE OPERATING PLEASE SEE INSTRUCTIONS ON PAGE 5

- Essay Control Functions and Benefits

quick start guide Product features RFG26M*** English Counter Height Design Surround Multi Flow Secure Auto Close Door System Twin Cooling System

SMT Quick-Tips: selecting a reflow oven. Robert Voigt, DDM Novastar

A Design for True Performance and Energy Savings In Refrigerated Compressed Air Dryers The Digital Scroll Dryer

TUNDRA & ROADIE OWNER S MANUAL

Scotsman Technical Training. CU50 Cube Ice Machine

Installation & Operations Manual for. MSC-A & MSF-A Model. Display Freezers. 5/16 Rev. A

Tempra Series WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS. Whole House Comfort. Germany

What is Commercial Refrigeration? When do you need a Commercial Refrigerator?

Heat Pumps for Swimming Pools

The Digital Scroll Dryer

PRIMUS IMPORTANT. User Manual and Product Specifications. Portable Fridge/Freezer. Part No. PRI18LP - 18 Litre. Read instructions before operation.

Bottled Water Dispenser

Ultra low temperature freezers. -40 C and -86 C. Green Line

Changes of State. Lesson 1

THERMAL ICE STORAGE: Application & Design Guide

Better Design, Better Control, Better Systems.

Ice Cone Freezing Experiment. OilExTech LLC

Laboratory refrigerators and freezers

Portable Refrigerator

11/2016. Mod: CCE10. Production code: CCB-10

Hydronic & HVAC Control Systems

PQS Independent type-testing protocol

Cold Weather Operation Of Cooling Towers

laboratory & sterilization technology

Incubator Set-up Instructions

Impact of Manual Defrost vs. Auto Defrost Freezers on Sample Temperature

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

Variable Refrigerant Flow (VRF) Systems

A Comparison of Aspirated Smoke Detectors

The Book of AERMEC NRL Sequence of Operation

ER MANUAL FOR YOUR BAUMATIC

2008 Refrigeration Specifications

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

Brewmaster Edition Chronical Fermenter 1 Barrel Supplemental Report

GENERAL PURPOSE LABORATORY GRADE REFRIGERATORS AND FREEZERS. Versatile 4 C and -20 C preservation for laboratory research and life science materials.

Conductive Heating Technologies for Medical Diagnostic Equipment. Russell Strehlow, Manager of Research and Development, Minco

Head Pressure Control Application Guide

Electric radiator test

Congratulations on your Guide Gear purchase

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

TCW 2000 Ice liner refrigerator and freezer PIJ

Setting the Benchmark

Refrigerator Freezer HD-368RWEW

1. SAFETY WARNINGS INSTALLTION Location Reversing the Door Swing Levelling the Unit... 3

Discover ebm-papst in commercial kitchen equipment. Durable and reliable products for constant use.

Well Insulated Houses: Helping to Stay Warm in Winter and Cool in Summer

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

REVCO MECHANICAL CRYOGENIC FREEZER

The Ultimate Guide to Vaccine Storage. TrueBlue.

Undercounter Refrigerator Operation Manual i.series and Horizon Series

TESTS OF ADSIL COATING

WCB Ice Cream. Introduces the. CREAM Freezer

REFRIGERATOR USER S MANUAL MODEL: HS-306LN

State of the Art. Exceptional Reliability

Ultra-Thin Flexible Heaters

WWSD. Power. DHW Demand. Maximum. Supply. Minimum Boiler DHW. Zone 1 / Cooling. Pump / Vlv. System Pump. UnOccupied. of full output NRTL/C LR 58223

Refrigerated Cool Box by Gerald Fitton

A heat pump that redefines comfort and efficiency.

YBC-5 Passive Vaccine Storage Device User Manual

Couverture B80 oneway seb.qxd:couverture B80 oneway seb.qxd. USA: CANADA :

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Cooling test results C-side replacement detector

Design and Build a. Solar House. Introduction. Design a model house that uses as little energy as possible to keep it warm.

The New Ice Age. Electrolux Professional Refrigeration. Pure. Zero waste. Sustainable. Electrolux Pebble Ice Makers

Cold Storage Management Standard Operation Procedure

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

Thermo Scientific ULT Freezers: Superior Thermal Performance

KE2 EvaporatorEfficiency Theory of Operation

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

INSTALLATION INSTRUCTIONS

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

Advances in Liquid Nitrogen (LN 2 ) Based Lyophilization Technologies

SAMPLE. added benefit of reduced operating costs during low demand periods, such as spring and fall.

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

USING THE REFRIGERATOR COMPARTMENT

Transcription:

Maluna Unhinged vs Yeti Tundra Thermal Performance Comparison January 2017 Abstract A Maluna Unhinged cooler was tested and measured for performance relative to a Yeti Tundra cooler. Three identical tests were performed in a controlled laboratory environment and conditions were set to create a typical user case scenario to keep beverages cold during hot Summer weather. The Maluna cooler was determined to outperform the Yeti cooler by more than 20%. Maluna Unhinged 50 (52.5 quart capacity) and Yeti Tundra 65 (57 quart capacity) in a 100 f thermal chamber with a case of beer and 22 pounds of ice each: Hours to 45 f Hours to 50 f Hours to 55 f Yeti Maluna Improve Yeti Maluna Improve Yeti Maluna Improve Test 1 69.7 86.8 24.5% 75.2 93.4 24.2% 81.5 100.8 23.7% Test 2 70.2 88.1 25.5% 75.6 94.6 25.1% 81.8 102.2 24.9% Test 3 69.5 86.7 24.7% 74.8 92.9 24.2% 81.2 100.2 23.4% Page 1

Introduction Maluna Unhinged coolers were designed in 2016 to compete in the high performance cooler market where cooler construction is made up with a rotomolded shell and pressure injected polyurethane insulation. The generally accepted market leader for these coolers (as defined by brand recognition and perceived thermal performance) is the Yeti Tundra series of coolers. Maluna coolers were designed to be unmatched in performance, features and value. While there have been unscientific and uncontrolled performance tests by the consumer community, Maluna set out to create a cooler that outperforms a comparable Yeti cooler in a controllable, measurable and scientific manner. This test document outlines work that Maluna has performed which measures relative performance differences between a Maluna Unhinged cooler versus a comparable Yeti Tundra cooler, and provide evidence that these measurements are repeatable. The Maluna Unhinged cooler was designed to outperform Yeti coolers and other competition through innovation: Unhinged design: A primary source of improved performance is the patent pending Unhinged design. This design creates a floating lid with an oblong hinge pin hole that provides the lid freedom of vertical movement on every edge of the cooler when it is shut. It has rear tensioning straps that when shut, provides downward tension along the rear edge to match the same tension from the front straps and create a uniform seal. Seal design: While the competition uses freezer style gaskets to seal between the lid and tub, the Maluna Unhinged cooler has designed a seal that was tested and optimized to be a high performance cooler gasket, not a freezer gasket. Tapered walls: Maluna coolers have walls that taper up from a standard wall thickness at the bottom of the cooler to increase wall thickness toward the top of the cooler to increase wall thickness by 50%. This provides more insulation at the top of the cooler where it is most important, and also provides a larger footprint for the specially designed high performance cooler gasket. Material selection: The materials sourced for the construction of Maluna coolers include a proprietary blend of additives to improve performance and durability. The polyurethane insulation has additives to eliminate or minimize any air bubbles and create a uniform and optimal density of insulation throughout the cooler. The polyethylene shell was designed to minimize thermal conductivity through the shell. Insulated drain plugs: Maluna Unhinged coolers come with a standard drain plug and an optional patent pending thermometer drain plug. Both of Page 2

these drain plugs are manufactured with insulation inside to ensure complete and optimal thermal protection. A scientific and controlled environment is required to properly measure relative performance. Controlled: There are many variables that determine how long a cooler will hold temperature. To compare thermal performance between two coolers, it is necessary, among other things, to control identical ambient temperature environments, mass of payload, specific heat of payload, starting temperature of payload (including temperature of ice), pre-conditioning of coolers, arrangement and form factor of payload (ice shape and size), exposure to sunlight, and of course temperature data capture. Relative: It is not reasonable to state an absolute amount of time that a cooler will hold ice without qualifying the environment. All else held equal, the amount of time that a superior cooler will outperform an inferior cooler is relative to the temperature difference between outside ambient temperatures and the temperature inside the cooler. As an example, if the temperature difference outside and inside the coolers double, the absolute amount of time that the coolers hold ice will be halved, but the relative percentage of time difference between the two will stay constant. It is reasonable and acceptable to state a relative percentage difference of time that two coolers will hold ice in a controlled environment. Purpose This test is intended to establish and quantify the relative thermal protection performance between the Maluna Unhinged cooler and the Yeti Tundra cooler. Scope This test will determine and control a typical user case scenario of keeping beverages cold during hot weather, and will calculate the percentage difference of time that the coolers will hold temperature in that single user case scenario. In this scenario, the only differences are the coolers. This test is not designed to evaluate relative performance differences as controlled variables are changed or stressed. Differences from effects of sunlight, wind, different ambient environments, or anything else are not changed or considered. The effect of fluctuating temperature between day and night cycles is not considered, and also would not be practical for calculating relative thermal protection performance differences. Materials & Methods Materials Thermal chamber with thermostat control designed to hold a constant temperature and accept two coolers in identical fashion at the same time. Maluna Unhinged 50 cooler (52.5 quarts actual volume) Page 3

Yeti Tundra 65 cooler (57 quarts actual volume) 24 Cold beers each cooler 22.0 Pounds of ice for each cooler (approximately 1.0 cubes) 13 Probed temperature recorders with new batteries Deltatrak model 20902 1 in each cooler: 12oz cold bottle of water prepared with an internal temperature probe 1 in each cooler: Drain plug prepared with a temperature probe to the inside of the plug Methods Symmetrical chamber: The thermal chamber used is designed to have perfectly symmetrical characteristics to perform A/B tests. Thermal chambers can have varying temperatures in different areas within the chamber, but a symmetrical chamber mitigates these conditions because it is the same differences for either cooler placement within the chamber. In this case, heat inlet and heat exhaust are directly across from each other, in the middle and between each cooler placement. Each cooler placement is exposed to identical conditions. Each cooler is placed equal distance from each side wall with similar distance from each other. Chamber seams where the lid opens and may create temperature changes are also symmetrical between the two sides. Multiple probes are placed symmetrically to confirm identical conditions for each cooler. Pre-conditioning: Care is taken to pre-condition the coolers and payload identically. Both empty coolers are pre-conditioned for a minimum of 48 hours next to each other in room temperature conditions (68 f -70 f) with lids open, drain plugs removed, away from any direct sunlight exposure. Payload must be exact same beginning temperature. This is accomplished with a splitting method; for instance, 48 pre-chilled beers in a refrigerator can have different temperatures depending where they are in the fridge (colder in the back, or warmer in the front by the door). Rather than removing the front 24 and place in one cooler and remove back 24 into the other cooler, splitting method removes them and places one for me one for you routine while placing into the coolers. Same is done as the ice is removed from freezer. Exactly 22 pounds of ice is measured for each cooler. It is also important that both payloads have exact same treatment during measurement and transport into controlled environment (time of exposure and handling methods must be identical). Pre-conditioning target temperature for ice is 0 f, and the target pre-conditioning temperature for beers and probed water bottles is 36 f. Thermal chamber is not pre-heated, it is conditioned to room temperature with the lid open because the heat up cycle is very fast. Page 4

Data recorder placements: 8 temperature data recorders are placed around the chamber, 4 on each side and completely symmetrical from each other. One above the cooler, one to the side wall of the cooler, one on the front wall in front of the cooler, and one on the back wall behind the cooler. All of them symmetrical to the placement of the probes of the other cooler. This is to confirm chamber symmetry and create redundancy for any failed data recorders. One additional data recorder is placed in the center of the chamber at the heat inlet source. 1 data recorder each is placed through each drain plug to measure internal temperature just inside the wall of the cooler. 1 data recorder each is placed with the probe inside a 12oz water bottle placed in the direct middle bottom of the cooler. Payload placement: 24 pre-chilled beers are placed standing up in the bottom of the cooler, surrounding the single pre-chilled probed water bottle. Any of the 24 beers that do not have room to stand up are placed on their side on top of the other beers. The ice is scattered over the top of the beers and water bottle until is it level across the entire cooler, while we make sure there is no mounding or ice stuck together during the process. The ice is not tamped, it is poured in to settle itself. Payload exposure during placement is exactly the same and the lids to the coolers are closed and strapped down at the same time. Data recording settings: Each data recorder is set manually to start data recording and to capture temperature readings every 2.5 minutes for up to 6.5 days which is maximum capacity for data points recorded, and most granular frequency for expected potential duration. Data recorders are set to begin capturing data as soon as cooler lids are strapped shut, chamber is shut and heater is turned on. Temperature setting: The temperature of the thermal chamber is set to a constant 100 f. Duration: Conditions are maintained and data is captured until both coolers drain plug probes have reached a minimum temperature of 60 f. Repeatability: The test is performed 3 times to confirm and ensure repeatability. Exceptional Conditions Individual cooler samples: Each of the three tests used 3 different individual Maluna coolers that were randomly selected from production. However, each of the three tests used the same cooler sample from Yeti which was a brand new Yeti Tundra 65 purchased at a retail location and went directly to testing. Based on the 3 samples from Maluna, there appears to be very little performance deviation Page 5

among them. A full analysis of individual performance deviation from different production units from either manufacturer was not within the scope of this test. Different sized coolers: At the time of testing, the only production cooler available from Maluna to test was the Unhinged 50 cooler which has an actual capacity of 52.5 quarts. The closest available cooler from Yeti to test was the Tundra 65 with an actual capacity of 57 quarts. Capacity may affect the ability of a cooler to hold temperature, and generally accepted that a smaller capacity cooler may have an advantage, but may be slight and not a measurable difference with a pairing this close. This cooler pairing was the closest possible (Yeti Tundra 50 has an actual capacity of 44 quarts). Thermostat control: Temperature control for the thermal chamber is a mechanically controlled heater that cycles on and off to maintain a constant mean temperature. With a setting of 100 f, the temperature may cycle +/- 2.5 f above and below 100 f on approximately 6 minute cycle time and 50% duty cycle. This method of thermostat control is instead of a more stable solid state controlled pulse width modulated heater that maintains a more constant temperature using a proportional integral derivative controller (PID controller). This is noted as an exceptional condition, but with the test conditions used, and the high frequency of cycle time, it is not considered to have any effect to the results and conclusions. Drain plug: The Maluna Unhinged coolers come standard with a polyurethane insulation filled drain plug, and an optional insulation filled drain plug with an electronic readout of internal cooler temperature. The drain plugs used for both coolers for this test, were modified Yeti drain plugs that were drilled to accept a temperature probe. This was done because they were well suited to internally seal the probe hole with water proof silicone sealant. It is expected that the Maluna cooler may have performed better with the insulated drain plug it was designed to use. Drain plug readings: The metal probe tips that were positioned through the drain plugs have a tip that reads temperatures just inside the bottom wall of the cooler. When payload is placed into the cooler (before any ice has melted), these tips can either be touching an ice cube, or be suspended in air between ice cubes and beer cans. A probe tip touching an ice cube can have a reading of 32 f or lower (prior to fusion), and a tip suspended in air can have a reading more than 40 f if not touching ice or a beer can. As ice melts, and probe tips submerge under water the drain plug probe readings then equilibrate. This has no effect on conclusions, as the measurements used for cooler performance are from the center placed water bottles with submerged probes. Drain plug orientation: While the thermal chamber is designed to be perfectly symmetrical, drain plug orientation when cooler is facing inward or outward is not symmetrical. For instance, the coolers are placed in the chamber so that heat flow is from one end of the coolers to the others. If both coolers are placed in the chamber Page 6

facing inward so that both coolers have front straps facing each other, then one cooler has a drain plug facing the inlet side, and the other cooler has a drain plug facing the exhaust side. If both coolers are oriented so that drain plugs are on the same side of the chamber, then one cooler would have front straps facing inboard, and the other cooler would have front straps facing outboard. It was determined to prioritize front strap symmetry so that the drain plug placement either on inlet side or exhaust side is not symmetrical. Drain plug orientation was rotated for each test and was determined to not be a material variable and have immeasurable impact to the results. Results Hours to 45 f Hours to 50 f Hours to 55 f Yeti Maluna Improve Yeti Maluna Improve Yeti Maluna Improve Test 1 69.7 86.8 24.5% 75.2 93.4 24.2% 81.5 100.8 23.7% Test 2 70.2 88.1 25.5% 75.6 94.6 25.1% 81.8 102.2 24.9% Test 3 69.5 86.7 24.7% 74.8 92.9 24.2% 81.2 100.2 23.4% Page 7

Discussion The test protocols were executed without any exceptions. There were no failed temperature recorders or interruptions to the controlled variables during testing. In a stable temperature environment, such as the 100 f thermal chamber, the relative performance difference can be calculated as the additional amount of time required to reach certain temperature thresholds. In this case, three thresholds were chosen within a reasonable temperature range that represents a range of temperature after the ice has completed it s fusion process (melted). The three temperature thresholds chosen were 45 f, 50 f, and 55 f. During the three tests, the Maluna cooler required between 17.1 and 17.9 additional hours for the probed water bottle to reach a temperature of 45 f, which is an improvement of 24.5% to 25.5% over the Yeti cooler. The Maluna cooler required between 18.1 and 19.0 additional hours for the probed water bottle to reach 50 f, or 24.2% to 25.1% improvement over the Yeti cooler. The Maluna cooler required between 19.0 and 20.4 additional hours for the probed water bottle to reach 55 f, or 23.4% to 24.9% improvement over the Yeti cooler. The data exhibited expected behavior. The temperature of the probed water bottles initially dropped from pre-conditioning temperatures, even temporarily below freezing because it was surrounded by ice that was pre-conditioned at 0 f. As the ice began it s fusion process, the probed water bottles settled into a stabilized temperature at or just above the ice melting point of 32 f. After the ice completely melted, the temperature rise displays an expected convex shape as the rate of temperature rise begins to slow as the difference between internal cooler temperature and ambient chamber temperature of 100 f begin to approach each other. The displayed chamber temperature in the graph represents an average of all 9 temperature probes from each test, and represents an average of the trailing 15 minutes chamber temperature to smooth out the swings from the thermostatically controlled swings of temperature of approximately +/-2.5 f on 6 minutes cycles with approximately 50% duty cycle (3 minutes temperature rise from ~97.5 f to ~102.5 f, followed by 3 minutes temperature drop from ~102.5 f to ~97.5 f). Essentially, the displayed chart of chamber temperature displays an average chamber temperature of 100.2 f for all 3 tests (2,641 data points over 110 hours), the actual calculated averages for all 3 tests are 100.1 f, 100.3 f, and 100.2 f for tests 1, 2, and 3 respectively. Each cooler was arranged with 2 internal probes. One probe was submerged in a 12oz water bottle in the middle of the payload mass as a representation of beverage temperature. The second internal probe in each cooler was through the drain plug to take an internal temperature just inside the cooler wall, which was submerged in a bath of water after the ice melted a sufficient amount. Page 8

The drain plug probes exhibited expected behavior and similar performance results: DRAIN PLUG PROBES Hours to 45 f Hours to 50 f Hours to 55 f Yeti Maluna Improve Yeti Maluna Improve Yeti Maluna Improve Test 1 73.4 89.4 21.8% 79 96.1 21.6% 85.2 103.6 21.6% Test 2 73 89.7 22.9% 78.9 96.4 22.2% 85.4 104 21.8% Test 3 73.2 89.3 22.0% 79 95.8 21.3% 85.4 103 20.6% The performance improvement of the Maluna cooler as measured at the inside of the drain plugs was still more than 20%. However, while the drain plug probes exhibited similar, consistent, and expected behavior, the performance improvement at the drain plug probes was not as great as the beverage probe. The beverage probes had a range of improvements between 23.4% and 25.5%, while the drain plug probes had a range of improvements between 20.6% and 22.9%. While this test was designed to measure performance difference as measured in the center probed water bottle, it was not in the scope of this test to determine cause of Page 9

differences between probe locations. The results are presented as a matter of interest. It is speculated that the difference may be caused by difference in cooler shapes. The Maluna cooler has a slightly taller shape with smaller footprint, while the Yeti cooler is more spread out. It is possible that a shape closer to a cube holds a temperature at center of payload mass more effectively than a shape closer to a pancake. A close look at the data shows a consistency in the chamber symmetry. An analysis of the first 110 hours of each test (2,641 data points each probe) shows that the different locations within the chamber can differ in temperature range (3.9 f test 1, 3.5 f test 2, 3.5 f test 3). However, the average difference in temperature between the two cooler locations using 4 symmetrical probe locations each are within 0.9 f for test 1 (advantage Yeti ), 0.3 f for test 2 (advantage Maluna ), and 0.1 f for test 3 (advantage Yeti ). 110 HOUR AVERAGE TEMPERATURES ( F) TEST 1 TEST 2 TEST 3 Chamber Variance Both Tops 100.6 101.5 100.6 Both Sides 101.7 101.6 101.6 Both Fronts 100.4 100.6 101.1 Both Rears 97.8 98.0 98.0 Center Inlet 100.2 99.2 99.3 Symmetry Maluna (top, side, front, rear) 100.6 100.3 100.4 Yeti (top, side, front, rear) 99.7 100.6 100.3 Conclusion This test was designed to establish and quantify the relative thermal protection performance between the Maluna Unhinged cooler and the Yeti Tundra cooler. This performance difference was tested using typical user conditions to keep beverages cold during hot Summer weather. The test was executed according to written protocols without any exceptions or failures. An analysis of the data shows that the experiment showed no unusual or unexpected behavior. The controls in the experiment were maintained and the conditions that both coolers were exposed to were identical. An analysis of the recorded temperature data of a beverage placed in the center of payload mass of both coolers shows that the Maluna Unhinged cooler held ice and beverage temperatures for more than 20% longer duration than the Yeti Tundra cooler. This result was shown to be repeatable using three tests of identical conditions. Page 10

Data Package See attached raw data package addendums, one for each test. Page 11