FR-A180 FR-A360. Occupancy detector. Use

Similar documents
LPCMPIRM65 & LPCMPIRDSI65

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Eco-sensors - PIR. Catalogue number(s): / / Use. 1. Use Technical characteristics (continued)

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Analogue Dimming Microwave Presence/Absence Detector

SWITCHLITE MRE SLDM ADJ

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

Direct Dim Microwave Presence/Absence Detector

Ceiling PIR HS presence detector. Product Guide. Overview. Features

MWS3A-PRM Product Guide

compact office 24V compact office 24V Lux

LED Compatible Daylight Harvesting and Motion Sensor System

compact office 24V compact office 24V Lux

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

SENSA MRE DDM MR

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

LPC3BSP65 & LPC3BDP65

PMCSF6 OCCUPANCY SENSOR

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

, ,

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Sensors and Detectors

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

1. Basic safety information 3 2. Proper use 3

Detector switch - Dual Tech

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

Dublin airport - Dublin, Ireland

User Manual 120/240/300 Outdoor Motion Detector

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Integrated PIR detectors

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

µdim Microwave Sensors User Manual

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Installation Guide. Ceiling PIR Detector (311) Features and Connections

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

Save energy. ARGUS presence detectors

EBMHS (standard & slim-line PSU)

Movement-based energy control

Reflective Optical Beam Smoke Detector User Guide

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

Emery County Senior Center Green River 06/07

Energy efficient lighting control

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

D-Tect 2 GJD300 Quad PIR Movement Detector

Detector switch - Dual Tech SCS

NO (SPST-NO) 10 A Internal installations Particularly suited for wall mounting

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

360º Surface Mount Ceiling PIR Light Controller

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

PIR OCCUPANCY SWITCHES

Passive infrared ceiling sensor

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Detailed operating instructions

Sensors Explained AUTOMATION

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

Occupancy Sensor Operation with Lighting Fixtures

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

2. Safety. 1. Product characteristics. 3. Proper use. 4. Operation. Function description. Presence detector

PIR movement and presence detectors 10 A

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Product Specifications

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

Product Specifications Dialog Room Controller* (*patent pending)

Product and Applications Description

Devices for Special Applications

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

1. Basic safety information 3 2. Proper use 3

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

IP65 High Bay Dual Sense Sensor

Installation Instructions

Movement Detector GJD 300

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

D-TECT Dual Tech. GJD360 Triple Technology External Detector

CHALLENGER 66 INDUSTRIAL

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

HART XL High Sensitivity Smoke Detection

Transcription:

5 488 Occupancy detector with daylight sensor Occupancy detector with integral daylight sensor for demand-based control of HVAC systems and lighting. Adjustable switch-on and switch-off delay Adjustable daylight-response threshold Direct switch-control of lighting up to 1800 W. Suitable for connection to controllers with stand-by or energy hold-off inputs Use Scope and limitations The occupancy sensors are ideal for use in areas where moving infrared sources (people, vehicles etc.) represent a significant criterion for the control of lighting and HVAC systems. Typical fields of application include school buildings, hospitals, museums, offices, laboratories, conference rooms, side rooms, factories and warehouses. Fluorescent lighting up to 1800 watts (and filament or halogen lamps up to 1150 watts) can be switched on and off without auxiliary relays. In principle, there is no need to install conventional light-switches. In areas where occupants are seated, it essential that full coverage is provided by occupancy sensors to ensure that every movement is registered. Aisles, gangways or infrequently used perimeter areas, by contrast, may be allowed to fall outside the coverage area. The following restrictions should be noted : x The use of occupancy sensors in libraries, reading rooms or in archive rooms with shelves arranged in close proximity should be avoided. x A manual switch or independently operated desk-lamp should be provided in areas where lighting is critical. x For special applications (e.g. cold stores) please consult your local Landis & Staefa office. Suitable lamps and luminaires Operation with dimmers and electronic low-voltage transformers does not present any problems. The type of ballast device used (capacitive, inductive, electronic) is irrelevant. x The following are suitable: fluorescent lamps or energy-saving lamps x Use with the following is not recommended: filament or halogen lamps Note Although not recommended, it is possible to use the daylight control function in conjunction with filament or halogen lamps, but only if the artificial lighting level is below the preset lux value, or where the daylight sensor is located sufficiently far away from the source of artificial light. (Otherwise oscillation (flashing at 10-minute intervals) can be set up). Landis & Staefa CA1N5488E September 1997 1/8

Functions The and occupancy sensors combine a PIR (Passive InfraRed) sensor and a daylight sensor in a single compact unit. The occupancy sensor (PIR sensor) responds to moving heat sources (people, vehicles etc.). It is optimised to enable it to detect the low-level activity of sedentary workers. The light sensor measures daylight intensity. It is capable of distinguishing between daylight and fluorescent lighting or lighting from energy-saving lamps. Two switching outputs are provided, to enable lighting and HVAC to be controlled independently : The N/O lighting contact closes when the measured daylight intensity is below the preset value and when movement is detected by the occupancy sensor. It opens either when the daylight intensity is above the preset value or when no movement is detected by the occupancy sensor. The HVAC contact (N/C) opens when the occupancy sensor detects movement and closes when no movement is detected. It is therefore suitable for occupancy-based control in individual room control systems. If the level of illumination in an occupied room exceeds the preset lux value a switch-off delay is activated; if it falls below the preset value, a switch-on delay is activated. This prevents the lighting being switched on and off in response to very short-term changes, such as passing clouds. Adjustments The response threshold for the daylight sensor and the switch-on and switch-off delays for lighting and HVAC can be adjusted on potentiometers located on the back of the sensor. 40757A 40856A 5 7 400 200 800 0 Min 10 2 Min 16 50 On Lux 5 7 400 200 800 0 10 Min 2 Min 16 50 On Lux "Lux" potentiometer (right) Daylight sensor threshold: 50 lux... f lux. In work areas the setting should be 400 lux, while in perimeter areas, a setting of 50 lux is sufficient. "Min" potentiometer (centre) Minimum switch-off delay for lighting: range 2...15 minutes HVAC switch-off delay: 8... 60 minutes. The switch-off delays for lighting and HVAC are permanently linked. The selected minimum delay-times define the period after which the lighting and the HVAC system will be switched off if no movement is registered by the occupancy sensor. The switch-off delay for the lighting is adaptive (self-learning). If the occupancy sensor detects only slight and infrequent movements, the programmed minimum switch-off delay is increased to 15 minutes. The device also "learns" from incorrect decisions. Thus, the switch-off delay will also be increased if the sensor detects a movement shortly after the lighting has been switched off. "Min" potentiometer (left) HVAC switch-on delay: 0...10 minutes The lighting is switched on without a delay. 2/8 CA1N5488E September 1997 Landis & Staefa

Type summary The occupancy detectors are available in 2 versions: Detector for wall-mounting, coverage 180, 45 vertical Detector for ceiling-mounting, coverage 360, 30 angle of incidence Ordering When placing an order, please specify the quantity, product description and type code. Example : 6 occupancy detectors Equipment combinations Operation with dimmers and electronic low-voltage transformers is trouble-free. The occupancy detectors are suitable for direct switching of fluorescent lamps (FL) or energy-saving lamps (PL). Any type of ballast device is suitable (capactive, inductive, electronic). Filament or halogen lamps are unsuitable. Technical design Both devices consist of an identical power section which also accommodates the connection terminals, and a plug-in sensor unit. The FR-180 and are distinguished by their shape, coverage and location in the room. The sensors have a white plastic cover plate fitted with a transparent Fresnel lens. Engineering notes Positioning the occupancy sensors wall-mounted sensor Installed at a height of 1.6... 2.2 m, the occupancy sensor detects movement within an area of 8 x 8 metres. In smaller spaces, it can be installed lower (in the place normally occupied by the light switch). In public areas or locations where there is a risk of vandalism, the sensors should be installed out of reach. Sensitivity is reduced when the range to be monitored exceeds 8 m. By careful positioning of the sensor, the coverage range can be extended to 10 m (length) x 16 m (width). In corridors and in warehouse aisles, it can be useful to fit the to the ceiling, using the normally horizontal fan-shaped coverage as a vertical "curtain". 45 40758 3 2 2,2 m 1 0 0 1 2 3 4 5 6 7 8 9 10 m Landis & Staefa CA1N5488E September 1997 3/8

ceiling-mounting sensor Mounted at a height of 2.5 m, the occupancy sensor registers movement within an area of 8 x 8 metres (or 6 x 6 m if the occupants are seated). The area monitored can be extended to 10 x 10 metres (or 8 x 8 m if occupants are seated) by installing the sensor at a height of 3 metres. There are several advantages to ceiling-mounting: cabling is simpler in suspended ceilings, the height of the sensors protects them from vandalism, and the sensors are less likely to be masked by furniture and fittings. 30 (diagonal 23 ) 40767 3.0 m 2.5 m 5 4 3 2 1 1 2 3 4 5 m Coverage area of the occupancy sensors The overlay diagrams on the next page can be used to determine the ideal position of the sensors. The diagrams (scale 1 : 100) showing the sensor detection range, will enable the user to visualise the optimum location for the sensor on the ceiling () or wall (). Method : Photocopy the diagram onto a transparent sheet and place this over a floor plan (same scale, 1 : 100) of the area to be covered. Reposition the transparency until the optimum coverage / detection area is achieved. See example on page 5. Coverage of (Scale 1 : 100) 40809 10 m 16 m 4/8 CA1N5488E September 1997 Landis & Staefa

Coverage of (Scale 1 : 100) 40807 Coverage at height of : 2.5 m 3.0 m 10 m 10 m Example For complete coverage of partitioned rooms, the and can also be used in combination. 40855 Ceiling-mounted sensor Wall-mounted sensor Landis & Staefa CA1N5488E September 1997 5/8

Mounting notes Mounting instructions (Ref. 35662) are enclosed with the sensor. The sensor can be mounted in a standard flush-mounting box or surface-mounting frame (depth 50 mm). If installed in metallic structures (perimeter ducts, ceiling plates etc.) the fixing plate must be earthed. When building works are in progress, it is recommended that, initially, only the power supply unit should be mounted. The sensor unit can then be fitted in the commissioning phase. Commissioning notes The three potentiometers on the back of the sensor unit, for daylight threshold and switch-on and switch-off delays, must be set (see "Adjustments", page 2). The sensor can be switched on either by switching on the power or by plugging in the sensor unit. Ensure that the orientation of the sensor is correct (use the lettering on the wall-mounted sensors to ensure it is the right way up; for the ceiling-mounted version, align the mating contacts with the terminals). Avoid the use of force when fitting the sensor unit. The occupancy sensor will then switch the lighting ON for 1½ minutes, after which it is ready for operation. Over the next 9 minutes, the device will respond without any delay to changes in the lighting level in the room. This permits easy checking of the daylight switching point (set on the "lux" potentiometer). Technical data Supply voltage AC 230 V, 50 Hz Max. voltage tolerance +10/ 14 % Intrinsic consumption with contact made 1.5 W Outputs: HVAC: Relay contact Lighting: Relay contact Service life of contact (lighting) Switch-on delay: (occupancy) Lighting HVAC Switch-off delay: (occupancy) Lighting HVAC Adaptive mode (lighting contact only) Daylight control N/C Min. 5 ma at DC5 V Max. AC 230 V, 2 A, volt-free N/O AC 230 V, 8 A for fluorescent lighting AC 230 V, 5 A for filament and halogen lamps 100 000 switching operations with inductive load of 8 A, cos M > 0.4 No delay 0...10 mins, adjustable 2...15 mins, combined with HVAC 8... 60 min. Self-adaptive mode extends switch-off delay up to max. 15 mins if required Lighting output switched automatically Daylight threshold adjustable from 50... f lux Materials: Housing ABS, flame retardant, recyclable Optics Fresnel lens Weight (including packaging): : 0.18 kg / : 0.32 kg Colour White, RAL 9016 Maintenance None required Terminals Plug-in terminals for rigid and flexible conductors max. 2.5 mm 2 Environmental conditions Ambient temperature: Operation 0... 50 C Storage / Transport 25... 70 C Ambient humidity: Operation / storage / transport < 95 %rh (without condensation) Protection class IP50 to IEC529 Security Relay contact 3.75 kv against mains voltage Conformity Meets the requirements for CE marking 6/8 CA1N5488E September 1997 Landis & Staefa

Connection terminals 40761 1 2 HVAC controller; volt-free contact 3 4 N AC 230 V 50 Hz Luminaires 5 L 6 40762A AC OUT AC IN 1 2 3 4 5 6 Application examples Parallel connections For coverage of large areas or rooms with recesses, several sensors may be connected in parallel. Since the load is switched by one device only, the total admissible load remains unchanged. 40763 AC 230 V L N Luminaires HLK HLK HLK 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 Manual OFF control Caution : GND connections between the PRU and other controllers are only permitted if the PRU is supplied from a separate transformer. To prevent the automatic function from being disabled by tampering, the sensor is not fitted with a manual switch. Where manual switching is required (e.g. to darken a room for slide projection etc.), a conventional switch can be fitted. In rooms used by different occupants (conference rooms etc.) a rotary switch with "OFF" and "AUTO" positions should be provided to avoid potential confusion. AC 230 V L N 40764 HLK Lighting bank 1 Lighting bank 2 1 2 3 4 5 6 Landis & Staefa CA1N5488E September 1997 7/8

Dimensions All dimensions in mm 85 40759 46.3 21.3 35.5 48 80 87 40760 46.3 21.3 35.5 48 95 1996 Landis & Gyr (Europe) Corp. replaces S1-02.66 8/8 CA1N5488E September 1997 Landis & Staefa