Booster Fan Ducting Kit Installation Instruction for Hybrid Electric Heat Pump Water Heaters

Similar documents
INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

SAFETY AND INSTALLATION MANUAL MODEL 8100

Extreme 4000 Duct Kit

Installation Instructions and Use & Care Guide

Integrated Ventilation System

SM Field Installed Electric Heat Kit

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Model 1820 Dehumidifier

Installation Instructions Preference Wall Mount Range Hood

Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

USER'S INFORMATION MANUAL

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

Installation Instructions Part No , Part No Part No

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

Camaro A/C Install Instructions

INSTALLATION INSTRUCTIONS

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

P-K MACH GAS-FIRED BOILER C1500H C2000H OUTDOOR BOILER KIT GUIDE

Installation Instructions

GCS Multipoint Carbon Dioxide Gas Concentration Sampler

Cooktop Chimney Ventilation Hoods

Power Supply Display Module PSDM. Installation and Operation Manual

USER'S INFORMATION MANUAL

CONTENTS WIRING DIAGRAM

24 VAC SYSTEM CONTROL KIT

INSTALLATION MANUAL CONDITIONING ENERGY RECOVERY VENTILATOR (CERV) MODEL CERV-001-PARTA, CERV-001-PARTB

USER'S INFORMATION MANUAL

PORT700CF Portable Fume Collector

Installation Instructions

USER'S INFORMATION MANUAL

24 VAC SYSTEM CONTROL KIT

Table 1. Serie of Digital Room Thermostats.

Desiccant Dehumidifier

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

BlueHeat AirTop 2000 Heater

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

USER'S INFORMATION MANUAL

Installation Instructions

Installation Instructions

AVANI Grinding Booth

INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION INSTRUCCIONES DE INSTALACIÓN

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

High Power Range Hood

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

Installation Electric Dryers Instructions 01

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Smart Choice Electric Dryer Installation Kit

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

Installation Instructions

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-C-0214

INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Installation Instructions

READ AND SAVE THESE INSTRUCTIONS

Installation Manual. Vent Kit for Condensing Tankless Gas Water Heater

Rotary XL (558 Series) and Classic (548 Series)

Dual-Hose Portable Air Conditioner User Manual

Fig. 1 - Unit PHD4 and WPH4

Installation Instructions

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Installation Instructions

Installation Instructions DAR 1150, DAR 1220 DAR 1230, DAR 1250

Installation Instructions


Dual Column Dehydrating Breather Manual

Installation Instructions

DIESEL/PARAFFIN HEATERS

Solatube Daylight Dimmer Installation Instructions

PARAFFIN/DIESEL HEATER

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

Owner s Information Manual

USER S INFORMATION MANUAL

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Installation Instructions

Downdraft Raised Vent

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

Installation Instructions

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Transcription:

Booster Fan Ducting Kit Installation Instruction for Hybrid Electric Heat Pump Water Heaters This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER WARNING CAUTION CAUTION DANGER indicates an imminently hazardous situation which, if not avoided, will result in injury or death. WARNING indicates a potentially hazardous situation which, if not avoided, could result in injury or death. CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage. INTROION Heat is absorbed from air entering the inlet (left or top, depending on the model) side of the compressor unit on top of the water heater and transferred to the water inside the storage tank. Cooler dehumidified air exiting the outlet (right) side of the compressor unit is a normal by-product of operation. In standard installations (using ambient air) a minimum installed space is required. - 1st generation (plastic top shroud) - 750 ft³ (21.2 m³). - 2nd generation (metal top shroud) - 700 ft³ (19.8 m³). Duct adaptors can be used to redirect inlet and/or outlet air from or to other locations to permit installation in confined spaces, improve performance and maintain comfort in occupied areas of the home. See the instruction manual that is shipped with the water heater for further instructions on using ducting kits for installation in confined spaces of less than miinimum spaces listed above. INSTALLATION LIMITATIONS There are two duct adaptors; one connects to the outlet side of the top shroud and one to the inlet side (optional). The two cannot be interchanged. Ensure the correct adaptor(s) is ordered prior to installation. Installation of the duct adaptors requires field supplied 8 flexible duct that can be obtained from a local HVAC supply store or home center. Use of smaller diameter ducting is not permitted. Air can be drawn from or expelled to the outdoors, an attic space, or to another room inside the home. Ducting must be connected to the outlet and may be connected as an option to the inlet (requires both duct adaptors), though the total length of duct must be installed per the ducting section is defined in this instruction. INSTALLATION CONSIDERATIONS The compressor unit on the water heater is disabled when the temperature of the air flowing to the inlet is lower than 45 F (7.2 C) or higher than 109 F (42.8 C). Air expelled from the outlet will be 7 F (4 C) to 9 F (5 C) cooler than the inlet air. These operational parameters must be considered when determining if a location to duct air from/ to will be suitable. IMPORTANT NOTE If the compressor unit is disabled for long periods of time due to inlet air temperature being too hot or too cold, the potential energy savings a heat pump water heater is able to provide may be significantly reduced. AIR INLET Outdoor air temperatures will often be lower than 45 F (7.2 C) in many regions during fall and winter months. Attic temperature will often exceed 109 F (42.8 C) in many regions during spring and summer months. For units installed in conditioned spaces - ducting outdoor air to the air inlet of the unit may place additional load on space heating and cooling equipment unless the air outlet is also ducted to an alternate location. Air being drawn from an alternate location inside the home may cause a negative pressure condition inside that area. As a result, cold or hot air from outdoors may be drawn into the structure and place additional load on the space heating and cooling equipment. AIR OUTLET Breathing Hazard - Carbon Monoxide Gas Do not duct air from a garage or other space where potentially harmful fumes from solvents, chemicals or exhaust from automobiles are present into any other space in the building structure. Gas and carbon monoxide detectors are available. Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. The air outlet from a unit installed in a garage or any area where solvents or other chemicals that emit potentially harmful fumes are stored or automobiles are located must never be ducted to any other space inside the building structure. This would include all occupied and unoccupied spaces such as attics or basements. Potentially harmful fumes and vapors from solvents and cleaners or automobile exhaust gases could be introduced into living spaces. Cold air blowing from the outlet into an alternate location inside the home may cause cooling discomfort and be objectionable. Cold air blowing from the outlet into an alternate location inside the home may place additional load on space PRINTED 0818 1 100081727_2000553361_3000020808_500009560 (VER 01, REV A)

heating equipment during fall and winter months. Ducting outlet air only to an alternate location may cause a negative air pressure in the installed space. As a result cold or hot air from outdoors may be drawn into the structure and place additional load on the space heating and cooling equipment. KIT PARTS LIST STANDARD HEAT PUMP USER INTERFACE MODULE EFFICIENCY HYBRID ELECTRIC VACATION BOOSTER FAN KIT PART # DESCRIPTION QTY 100088429 PRESSURE SENSING SWITCH KIT 1 100082340 BOOSTER FAN 1 100029527 JUNCTION BOX 1 100003967 JUNCTION BOX COVER 1 100088421 3/8" CABLE FITTING 2 100081727 KIT INSTRUCTIONS 1 100081831 CARTON BOOSTER KIT 1 Table 1. The following kit must be purchased to complete the installation: 1st Generation (plastic top shroud) Required: Outlet Air Duct Kit PN 100272470 Optional: Inlet Air Duct Kit PN 100272481 2nd Generation (metal top shroud) Duct Kit (both inlet and outlet) PN 100269724 Tools required: #2 Phillips screwdriver, wire cutters, scissors. Supplies needed: nut driver, drill, 8 insulated flex duct, duct clamp, or strap, appropriate duct termination, duct tape, 8 metal duct connector, and junction box mounting screws. Important: Use only factory authorized replacement parts. If you lack the necessary skills to properly perform the installation, you should not proceed, but get help from a qualified service technician. PRIOR TO INSTALLING THE ADAPTORS WARNING Electrical Shock Hazard Before removing any access panels or servicing the water heater, make sure the electrical supply to the pump station is turned OFF. Failure to do this could result in death, serious bodily injury, or property damage. POWER BUTTON: ON - GREEN STANDBY - RED Display Segment Operational Mode Indication Light HEAT PUMP ELEMENT LOCK EFFICIENCY F/ C Figure 1. - 1st Generation Models Temperature Unit Indication Light F C DAYS Vacation Time Indication Figure 2. - 2nd Generation Models INSTALLATION OF THE ADAPTOR: F Temperature Up (Increase) Button Temperature Down (Decrease) Button Mode/Enter Button NOTE: For 2nd Generation models with a metal shroud, follow kit instructions 100269724 1. Remove the screws from the right louvered access panel and remove the panel. See Figure 3. NOTE: These Adaptors are not interchangeable. 2. If installing the inlet duct adaptor Remove the 8 screws from the left louvered access panel of the unit. AIR TOP SHROUD 1. Press the power button on the User Interface Module (UIM) to place the water heater in Standby Mode see Figure 1. (For 2nd Generation models, skip to step 2) Note: Power to the board is still present at this time. 2. Turn off all power to the unit at the breaker/fuse panel prior to removing any panels. 2 SCREWS (8) LEFT INLET PANEL USER INTERFACE MODULE (UIM) RIGHT OUTLET PANEL Figure 3. FLOW SCREWS (8)

3. Using the eight (8) screws removed earlier attach the new duct adaptor panel to the top shroud of the unit. The new duct adaptor panel should be oriented with the louvered portion of the panel located at the bottom of the panel to ensure that the panel lines up with the existing holes see Figure 4. 4. Slide insulation back over the duct core and the lip of the inlet duct adaptor. Use duct tape to secure the insulation to the inlet duct assembly see Figure 7. TAPE TAPE INSULATION INSULATION Figure 4. INSTALLATION OF THE WORK 1. After the desired length of 8 duct has been determined (see tables), carefully cut completely around and through the duct insulation with a pair of scissors. 2. Using a pair of wire cutters, cut the wire inside the core duct. Fold the insulation jacket back away from the core duct see Figure 5. CORE WIRE CUTTERS Figure 7. 5. Add support to the duct work as necessary with ducting tube hooks or as required by local codes. Special attention must be given to prevent large droops in the duct work which could allow moisture to pool. 6. The appropriate duct termination shall be added to the termination end of the duct. This termination shall prevent any debris or rodents from entering the duct work and shall minimally restrict the airflow through the ducting. In addition the termination shall be designed to prevent rain from entering into the duct work if terminated to the outside. 7. The flow area termination must be at least 40 sq in. to avoid overloading the fan. BOOSTER FAN WARNING Electrical Shock Hazard Before removing any access panels or servicing the water heater, make sure the electrical supply to the pump station is turned OFF. Failure to do this could result in death, serious bodily injury, or property damage. INSULATION Figure 5. 3. Slide at least 1 of the core duct over the ducting adaptor lip and seal with at least two (2) wraps of duct tape. Additionally, secure the core duct with a band clamp or duct strap placed over the ducting adaptor and tape see Figure 6. ING ADAPTOR ZIP-TIE ING ADAPTOR Install the booster fan per it s included instructions. NOTE: The booster fan is only to be located on the outlet side of the installation. Ensure the airflow is pulling away from the unit. CORE CLAMP TAPE CORE TAPE Figure 6. 3

SINGLE INSTALLATIONS ELBOWED / 90 TURNS Figure 10. Figure 8. ING INLET AND OUTLET PORTS LOCATION SINGLE INSTALLATIONS STRAIGHT Figure 11. Figure 9. TYPE 9. 10. 11. ELBOWS/90 0 1 2 1ST GEN MAX EQUIVALENT LENGTH 2ND GEN MAX EQUIVALENT LENGTH Maximum Elbows or 90 turns is 2. 25 25 20 100 100 95 Table 2. 4

DUAL INSTALLATIONS STRAIGHT BOOSTER FAN Pressure Sensing Switch Junction Box HVHP Water Heater Mounting Support Figure 12. Figure 15. BOOSTER FAN Pressure Sensing Switch Junction Box HVHP Water Heater Figure 13. Figure 16. DUAL INSTALLATIONS ELBOWED / 90 TURNS BOOSTER FAN Pressure Sensing Switch Junction Box HVHP Water Heater Mounting Support Figure 14. Figure 17. 5

BOOSTER FAN HVHP Water Heater Pressure Sensing Switch Junction Box Mounting Support Figure 18. Figure 21. Maximum Elbows or 90 turns is 2. BOOSTER FAN TYPE 12. 14. 16. 18. 20. ELBOWS/ 90 0 1 2 2 2 Pressure Sensing Switch Junction Box 1ST GEN MAX. EQUIV. LENGTH 20 20 15 15 15 HVHP Water Heater Table 3. Mounting Support TYPE ELBOWS/ 90 13. 15. 17. 19. 21. 0 1 2 2 2 Figure 19. 2ND MAX EQUIV. LENGTH GEN 60 60 55 55 55 Table 4. Figure 20. 6

FLEX CONNECTOR / SPLICE In order to securely mount the pressure switch air tube to the flex duct an 8 metal connector may be purchased at a local home goods store. 1. Drill a 1/4 to 5/16 hole in the connector per Figure 22. 2. Remove any burrs or sharp edges from the hole. DRILL 1/4-5/16 PRESSURE SENSING SWITCH AND JUNCTION BOX The pressure switch must be located within 30 inches of the duct connector spliced into the flex duct. The junction box should be fixed on the solid support, and the location should be determined to meet following requirements: Make the pressure sensing switch to be within 3 feet distance from the edge of air outlet part on the heat pump water heater. Make the junction box within 3 feet distance from the booster fan junction box. If the distance has to be further than 3 feet, then a 3 core cable (maximum current 1.0 amps) needs to be prepared to replace the booster fan cable. The pressure switch diaphragm must be mounted vertically see Figure 24. Figure 22. 3. Insert the pressure tube grommet into the drilled hole. A lubricant may be used to ease the grommet installation. 4. Insert the pressure tube through the grommet to a depth of 1/4 per figure Figure 23. PRESSURE TUBE GROMMET METAL FLEX CONNECTOR WALL NSERT 1/4 DEEP Figure 23. 5. Cut the flex duct using the same technique from the section Installation of the Ductwork on page 3. 6. The splice must be inserted at a maximum of 3 feet from the planned location of the pressure switch. 7. Install the connector and tape securely. Figure 24. 1. Mount the pressure switch to the junction box per Figure 25. NOTE: WIRING NOT SHOWN FOR CLARITY Figure 25. 7

2. Mount the junction box to a wall per Figure 26. A studded wall mount is preferable. WIRING WARNING Electrical Shock Hazard Before removing any access panels or servicing the pump station, make sure the electrical supply to the unit is turned off. Failure to do this could result in death, serious bodily injury, or property damage. Figure 26. 3. Connect the pressure tube to the fitting on the air switch diaphragm. See Figure 27. 1. Install two cable fittings on the junction box. One is for wiring the booster fan cable into the junction box, the other one is for wiring the power line into the junction box. 2. Wire the booster fan cable into the junction box and fix by fastening the two screws of the cable fitting. 3. Use the wire nuts provided in the pressure sensing switch kit to wire the pressure switch, fan cable and the power line based see Figure 28. PRESSURE SWITCH PRESSURE TUBE TRANSITION JUNCTION BOX RED BLACK WHITE GREEN BLACK WHITE GREEN BLOWER JUNCTION BOX BLOWER SPEED SELECTION SWITCH BLOWER JUNCTION BOX GROUND NEUTRAL 115 VAC LINE G L L AC 120V 60HZ Figure 28. CONNECTOR NOTE! DO NOT CONNECT POWER SUPPLY UNTIL THE ING KIT IS COMPLETELY INSTALLED. 4. Install the junction box cover. 5. The ducting kit installation is complete. Figure 27. 8

RESTORING OPERATION 1. Restore power to the water heater at the breaker/fuse panel. Press the power button on the UIM see Figure 1. NOTE: When powered on the unit may start to run a diagnostic which takes several minutes. 2. Follow the Operating Your Water Heater section found in the Installation Instructions and Use and Care Guide for restarting your heat pump water heater. 3. Check the UIM for any errors and correct accordingly. TRIAL OPERATION 1. Power on the unit and the junction box for the booster fan and pressure switch. 2. Start the heat pump water heater in hybrid mode or efficiency mode. 3. Wait for the unit fan to start (listen to the sound and observe the air flow inside of the ducting tube, this may take around ten minutes). 4. The booster fan should start around 5 seconds after the unit fan start. Refer to the trouble shooting section on the pressure sensing switch installation instructions for trouble shooting if the booster fan could not start successfully. If the booster fan still fails to start, contact profession service people for additional technical support. MAINTENANCE Please refer to the booster fan user s manual for fan cleaning procedures. Please refer to the heat pump water heater s manual for the heat pump water heater maintenance information. TROUBLESHOOTING Please refer to the pressure sensing switch installation instructions for the trouble shooting method. 9

NOTES 10

NOTES 11

NOTES 12