Technical description

Similar documents
Fire & Security Products. Siemens Building Technologies Group

XC1003-A Extinguishing control unit

DT1101A / DT1102A / DO110xA Automatic fire detectors

Sinteso fire detectors

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multisensor fire detector

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

FDOOT241-A9-Ex Multisensor fire detector

OH110, OP110, HI110 Automatic fire detectors

OH720, OP720, HI720, HI722

FD20 Sinteso Detector system

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

OOH740, OOHC740 Automatic fire detectors

DF1101-Ex Infrared flame detector

DICTATOR Hold-Open Systems for Hazardous Areas

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Inductive slot sensor

PEPPERL+FUCHS GmbH

Technical Data. Dimensions

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Technical Data. Dimensions

DF1151-Ex Infrared flame detector

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DB5 Intrinsically Safe Sounder Type DB-5

Technical Data. Dimensions

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Installation and Operating Instruction

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Barrier. ED /07/09 Release to production R.P. A ECO N DATE DESCRIPTION OF CHANGE CHG By ISSUE TITLE TC842B1007 AE PRODUCT SPECIFICATION

FDOOT241-9, FDOOT241-A, FDO241, FDT241

INSTRUCTION MANUAL (ATEX)

DC1192 Input /Output module

4) Intrinsic Safety Certification

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Series 65 Product Guide MAN 3036

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

FDOOT221, FDO221, FDT221

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

ASA linear smoke detector

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

VERSAFLOW VORTEX Supplementary instructions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Consultant Specification AGILE Wireless Fire Detection System

Fisher LCP100 Local Control Panel

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

OPTIBAR P 1010/2010 C Supplementary instructions

Quick Selection Guide Fire Systems LSN Periphery

SERIES 65 ENGINEERING PRODUCT GUIDE

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

OilSET-1000 (12 VDC)

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Analogue addressable devices

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Audible warning devices for external alarm

Fire Door Control Solutions

PROFIBUS-PA Display RID 261 PROFIBUS-PA

SERIES 65 ENGINEERING PRODUCT GUIDE

Safety instructions VEGAPULS 64

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

SIMATRIX NEO V2. User Manual. Building Technologies. Fire Safety & Security Products

Intrinsically Safe Flame Detector Installation Guide

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

AND INSTALLATION MANUAL

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

Product ID. General. TE CONNECTIVITY SENSORS /// EXxxHyy Ex-Atex & NA 09/2017 Page 1

SET-2000 Hi Level/Oil

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Operating Manual MS220DA

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Snifter ATEX22 VERSION. User Manual. Distributor

SET Installation and Operating Instructions. Level switch for one sensor

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Orbis IS Product Guide MAN 3041

optical detector multisensor detector heat detector mounting bases product guide

standards: standards:

Operating Manual MS220KA and MSR220KA

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

REA 105 Arc Protection Module. Operator s Manual

INSTRUCTION MANUAL (ATEX / IECEx)

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Transcription:

Distribuidor Autorizado: www.tucanobrasil.com.br DO0A Ex, DT0A Ex, DT02A Ex Wide spectrum smoke detector, collective Heat detectors, collective, intrinsically safe Technical description Fire & Security Products

. Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger anerkennt diese Rechte und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder ausserhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist. We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our prior express written authorization, nor to use it for any purpose other than for which it was delivered to him. Nous nous réservons tous les droits sur ce document, ainsi que sur l objet y figurant. La partie recevant ce document reconnaît ces droits et elle s engage à ne pas le rendre accessible à des tiers, même partiellement, sans notre autorisation écrite préalable et à ne pas l employer à des fins autres que celles pour lesquelles il lui a été remis. Ci riserviamo ogni diritto relativo al presente documento e sull oggetto illustrato in esso. La parte che riceve il documento si impegna a non renderlo accessibile a terzi, né per intero né in parte, senza la nostra previa autorizzazione scritta ed a non usarlo per altri scopi di quello per il quale è stato rilasciato.

Brief overview...................................................... Characteristics......................................................2 Design............................................................ 2 2 Technical data.................................................... 3 3 Principle of operation.............................................. 4 4 Environmental influences.......................................... 5 4. Influence of the ambient temperature.................................. 5 4.2 Other influencing variables........................................... 5 5 Application....................................................... 6 5. Compatibility....................................................... 6 5.2 Alignment functions................................................. 6 5.3 Application........................................................ 6 5.4 Installation......................................................... 6 6 Commissioning................................................... 7 7 Maintenance...................................................... 7 7. Functional check................................................... 7 7.2 Overhaul.......................................................... 7 7.3 On-site measurement with the DZ94 detector test set................. 7 8 Terms............................................................ 8 I

II

Brief overview OptoRex DO0-Ex Dimensions Ø 5 47...70 ThermoRex DT0-Ex / DT02-Ex Dimensions Ø 5 47...70 5 54,5 With base DB0 With base DB0. Characteristics For applications in explosion-hazard areas of zones and 2 Balanced response behavior and wide range of applications High reliability and stability through new, high-quality optoelectronic sensor system and fully automatic manufacturing and inspection processes For applications in explosion-hazard areas of zones and 2 Heat detectors to meet the highest requirements DT0-Ex class AR heat detector with wide application range (up to +50 C) DT02-Ex class BR heat detector for high ambient temperatures (up to +70 C) Response behaviour immune to deceptive phenomena with rapid and slow increase in temperature through: Intelligently designed differential characteristics Precise maximum temperature alarm activation with quality thermosensor High degree of reliability and long-term stability High resistance to: Electromagnetic interference (EMI) intelligently designed circuit Soiling, temperature fluctuations, humidity and corrosion achieved through custom developed, protective circuit board coating Together with detection line coupler and shunt Zener barrier, compatible with Cerberus control units with collective signal evaluation Manufactured in state-of-the-art SMD technology Bayonet fitting for connection to base simplifies detector replacement Comprehensive range of detector base accessories for special applications

.2 Design OptoRex DO0-Ex The OptoRex DO0-Ex is eminently suited to early detection of smoldering fires, but it also quickly detects flaming fires that produce smoke. The newly developed, high-quality optoelectronic system ensures a homogenous response behavior across a wide smoke spectrum, ranging from light-colored to dark smoke. The OptoRex DO0-Ex conforms to EN 54-7 and is consequently a universal smoke detector. ThermoRex DT0-Ex / DT02-Ex The DT0-Ex/DT02-Ex ThermoRex is suitable for the monitoring of rooms in which upon an outbreak of fire, a rapid rise in temperature is to be expected. The DT0-Ex ThermoRex complies with standard EN 54-5 and can be used for a wide range of applications. The DT02-Ex ThermoRex complies with standard EN 54-5 and is suitable for higher ambient temperatures. The built-in response indicator (red LED) serves as a local status indicator. An external response indicator can be connected to the base. For periodic factory cleaning the detector can be easily disassembled. The detectors are fully electronic and are not subject to wear and tear. To protect it against environmental influences the electronic circuit has a specially developed circuit board protective coating. The DB0 detector base is mounted on the ceiling direct on the recess box direct, or surface-mounted using the DBZ9 base attachment and connected to the control unit via twin wire. The base is fitted with spring terminals for connection. The detectors are secured in the base DB0 with a vibrationproof bayonet fitting. Efficient installation and removal of a detector is possible by means of the DZ9 detector extractor. For testing of the DO0-Ex serves the RE6 testing unit. DT0Ex and DT02-Ex can only be tested with RE6T in non-explosion hazard areas. By means of extension tubes this work can be carried out up to a height of 7 metres without additional tools. A range of base accessories is available for installation in wet areas and for protection against theft etc. 2

2 Technical data Normal ambient conditions, if nothing else is specified: Temperature T a DO0-Ex = 20 C (293K) DT0-Ex/DT02-Ex = 25 C (298K) Air pressure p = 000hPa (750 Torr) Parameters Symbol Unit DO0-Ex DT0-Ex DT02-Ex Conditions Operating voltage U b VDC 7......... 24 6......... 24 6......... 24 (quiescent condition) Max. permissible voltage U max VDC max. 27 max. 27 max. 27 Starting current I e µa max. 60 max. 00 max. 00 max. 25s after switch-on Operating current (quiescent condition) I b µa max. 00 max. 00 max. 00 for DT0-Ex T a =25...50 C for DT02-Ex T a =25...70 C Alarm voltage at I A =... 0mA U A V 5........ 0 5........ 0 5........ 0 at I A =...60mA U A V 5........ 2 5........ 2 5........ 2 Max. alarm current, pulsed I A ma max. 00 max. 00 max. 00 must be limited externally f 0.5Hz, Duty Cycle 50% Reset voltage U R V 2......... 6 2......... 6 2......... 6 Reset current I R µa 20....... 500 40....... 500 40....... 500 Reset time (U R = 2V) t R s max. 2 max. 2 max. 2 Response integrating time t A s typ. 7 -- -- Response sensitivity D %/m typ. 3.0 -- -- smoke sensitivity with paraffin test aerosol (m/s) Electrical sensitivity signal voltage U3A V.2........ 2.8 -- -- measurement with DZ94 Ext. response indicator: Voltage Current Flashing frequency Capacitance detection line AI line Inductance detection line AI line Response sensitivity temperature increase dt/dt = 0K/min. EN 54-5 class AR max. release temperature EN 54-5 class BR max. release temperature U ie I ie dt V ma Hz C.5....... 6 max. 50 nf 33nF - 40µH --.5....... 6 max. 50 nf 33nF - 40µH 20......... 40.5....... 6 max. 50 nf 33nF - 40µH 20......... 40 f 0.5Hz, Duty Cycle 50% depending on line module T a C -- 54......... 62 T a C -- 74......... 85 Electromagnetic compatibility V/m min. 50 min. 50 min. 50 MHz... GHz Operatic compatibility T a C -25...... +60-25...... +50-25...... +70 Humidity 34 C 95% rel. 00% rel. 00% rel. >34 C 35g/m 3 abs. 35g/m 3 abs. 35g/m 3 abs. Storage temperature (continuous) T l C -30...... +75-30...... +75-30...... +75 Protection category IP44 IP44 IP44 IEC60529 Colour white RAL900 white RAL900 Standards for fire detectors EN54-7 EN54-5 class AR white RAL900 EN54-5 class BR - for explosion-hazard areas EN5004 EN50020 EN5004 EN50020 EN5004 EN50020 Application category IEC6072 3 3K6 3K8H 3K8H Ex classification EEx ib IIC T4 (T a 60 C) EEx ia IIC T4 (T a 50 C *) EEx ia IIC T4 (T a 70 C *) Ex approvals - PTB Nr. - ASEV Nr. PTB 02 ATEX 235 PTB 02 ATEX 2097 96..0358 95..03 Load factor KMK.6 PTB 02 ATEX 2097 95..03 transient condensation allowed * not Ex conditional (Alarm release DT0-Ex 54 C DT02-Ex 74 C) Intrinsic safety: Intrinsic safety «i» when using a certified shunt Zener diode barrier with the following data: R i 280Ω U i 28V I i 00mA P i 700mW 3

3 Principle of operation OptoRex DO0-Ex ThermoRex DT0-Ex / DT02-Ex The OptoRex DO0-Ex is based on the principle that smoke scatters light. An infrared LED (IRED) transmits brief, intensive light pulses into the scattering chamber. The receiving element is screened off from direct IR light incidence and reflections. Smoke entering the chamber scatters the light so that some of it reaches the receiver whose signal is evaluated by the electronics. After three positively evaluated pulses an alarm is transmitted to the control unit. Time base 2 in the integrated circuit controls the logic unit 3 and produces pulses for controlling the IRED light source 5 via the amplifier 4. If the detector is not contaminated and the air is clean, no signal is available at the receiver 6. If the air contains smoke, the receiver sees a signal that is transmitted via the amplifier 7 to the discriminator 9. Integrated in the amplifier is a multiple coincidence circuit that generates the difference between a light and a dark measurement which has the effect that no interference signals and «only» smoke induced signals are amplified and transmitted. In circuit 8 a stable reference voltage U aref is produced which in discriminator 9 forms the alarm threshold. The detector sensitivity is set with the trimming resistor 0. The signal voltage U sig at the output of the receiving amplifier can only be factory-measured with the aid of special measuring equipment. The alarm threshold U aref is used for measuring the alarm stroke U3A on site with the detector measuring instrument DZ94. The logic unit 3 evaluates the pulses of discriminator 9 and after the third pulse activates the alarm stage integrated in ASIC. Also activated in the event of an alarm are the internal response indicator 2 and an external response indicator 3 if available. The alarm stage is self-holding and is restored to the initial condition only when reset by the system control unit (through brief interruption of the operating voltage). The intrinsically safe detector circuit is isolated from the line circuit by protective diodes 4. 5 6 4 ASIC 7 9 0 U sig U3A U aref 8 3 2 4 Detector B D F 2 3 E C A Base U B + Operating voltage - Shunt Zener diode barrier The ThermoRex DT0/DT02 measures the ambient temperature with the NTC thermistor R m in the tip of the sensor and measures the temperature in the detector housing with the NTC thermistor R g. Rapid temperature changes bring about a faster change of resistance with thermistor R m than with thermistor R g. This causes a positive voltage shift at point P. As soon as this voltage exceeds a fixed threshold value, the threshold value detector 3 activates multivibrator 4 and an alarm is given. If, due to a very slow increase in temperature, the resistance values R m and R g fall to the same extent, upon reaching a maximum temperature determined by resistors and 2 an alarm is given. At the same time resistor 2 accelerates response for fast changes in temperature. The weak current I B flows in non-alarm condition. As soon as the multivibrator 4 becomes conductive, the response indicator alarm current I A flows. At the same time the response indicator 6 built into the detector is activated via the driver stage 5. One external response indicator 7 may be connected. The multivibrator remains in self-hold condition until the control unit is reset by briefly interrupting the operating voltage, whereupon it reverts to its original state. The intrinsically safe detector circuit is isolated from the line circuit by protective diodes 8. 2 3 6 5 Detector + Operating voltage C A - Shunt Zener diode barrier Base Fig. Block diagram DO0-Ex Fig. 2 Block diagram DT0-Ex/DT02-Ex R m P R g MB I B 4 I A 8 B D F 7 E U B 4

4 Environmental influences 4. Influence of the ambient temperature OptoRex DO0-Ex 5 [%/m] 4 3 DO0A-Ex 2 0-0 ϑ 0 0 20 30 40 50 60 [ C] Ambient temperature Fig. 3 Smoke sensitivity of the OptoRex DO0-Ex as a function of the ambient temperature 4.2 Other influencing variables Ambient light, air drafts and fluctuations within the specified operating voltage range have no influence on the detector. 5

5 Application 5. Compatibility Control units: Bases: 5.2 Alignment functions None. Compatible with all Cerberus control units with collective signal evaluation together with input/output module DC92 and shunt Zener barrier DB0 5.3 Application OptoRex DO0-Ex The OptoRex DO0-Ex is suitable for applications in explosion-hazard areas of zones and 2. Due to its EN 54 compliance, the OptoRex DO0-Ex can be used as a universal smoke detector. 5.4 Installation ThermoRex DT0-Ex / DT02-Ex The ThermoRex DT0-Ex/DT02-Ex is suitable for applications in explosion-hazard areas of zones 0, and 2. The ThermoRex DT0-Ex can be used up to a temperature of 50 C and the DT02-Ex up to a temperature of 70 C. The DT0-Ex/DT02-Ex are especially suitable for monitoring rooms and installations in which in the event of fire, a rapid increase in temperature is to be expected, or where other types of detector cannot be used because work processes cause smoke, dust, exhaust gases etc. The recommended monitoring areas, distances between detectors etc. can be found in the national guidelines, the Cerberus «Guidelines for Planning and Application» (CRP), «Fire Detection in Explosion-hazard Areas», document e204., or the «Security Guide». Bases are connected together by twisted twin wire. Shielded cable is only required for special applications, e.g. in the case of powerful high frequency fields or special national guidelines. For detailed information, see «Fire Detection in Explosion-hazard Areas», document e204.. Non-explosion-hazard area Explosion-hazard area Detection line, control unit sided Supply 24VDC Input/output module DC92 Shunt Zener diode barrier SB3 Ex Ex max. 5 DO0-Ex max. 25 DT0/02Ex Equipotential bonding Ex EOL22(Ex) End-of-line device Fig. 4 Connection diagram for DO0-Ex and DT0-Ex/DT02-Ex 6

6 Commissioning To prevent unnecessary soiling during the construction phase, the detectors should be inserted into the bases just before the system is put into service. For detailed information, see «Fire Detection in Explosion-hazard Areas», document e204.. 7 Maintenance 7. Functional check A functional check of the detectors must be performed periodically (usually once per year) by forcing each detector to respond by means of a suitable testing device (RE6 or DZ92 for DO0-Ex or RE6T for DT0-Ex/DT02-Ex). Detectors that do not respond or which are mechanically damaged must be replaced. 7.2 Overhaul All detectors should be jointly replaced and factory overhauled in intervals of 2 to 8 years, depending on the environmental conditions and the severity of contamination.!! Important! The DZ93 and RE6T detector tester and the DZ94 detector test set must only be used in areas where there is no explosionhazard! Electrostatic danger The housing is made of plastic and has a surface resistance of >GigaΩ which means there is a risk of electrostatic discharge. Therefore the manual call point should not be located where there is powerful ventilation. Cleaning with solvents is forbidden. 7.3 On-site measurement with the DZ94 detector test set OptoRex DO0-Ex ThermoRex DT0-Ex / DT02-Ex The voltage U3A can be measured and alarm activation checked with the DZ94 detector test set. The U3A voltage measured is directly proportional to the remaining voltage increase for alarm. The operating current can be measured and alarm activation checked with the DZ94 detector test set. Detectors with values which lie outside those in the technical data must be replaced. 7

8 Terms ASIC CC CZ.. DB0 DBZ9 DC92 DO0-Ex DT0-Ex DT02-Ex DZ9 DZ94 EMC EMI ESD IRED KMK NTC-Thermistor RE6 RE6T R g R m RI (AI..) S SB Application Specific Integrated Circuit Fire detection control unit AlgoControl to fire detection system S Fire detection control unit to fire detection system MS9 Base for collective DS fire detectors Base attachment Input/output module OptoRex smoke detector, for explosion-hazard areas ThermoRex heat detector with static alarm threshold 60 C, for explosion-hazard areas ThermoRex heat detector with static alarm threshold 80 C, for explosion-hazard areas Detector exchanger Detector test set Electro Magnetic Compatibility Electro Magnetic Influence Electro Static Discharge Infra-Red Emitting Diode Load factor for collective elements Negative Temperature Coefficient Thermistor Detector tester Detector tester for heat detectors Measuring sensor for housing temperature Measuring sensor for ambient temperature Response indicator Generic term of fire detection system S Shunt Zener diode barrier 8