SENTINEL A - Fault Passage Indicator

Similar documents
SENTINEL D - Fault Passage Monitoring

REA 105 Arc Protection Module. Operator s Manual

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

VAMP 120 & 121. Arc flash detection units. Product picture

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Kickspot Self-testing/AutoDiag self-contained emergency lighting unit

Early Streamer Emission Lightning Rod REMOTE TESTING

Universal fault annunciator for panel mounting

EasyTronic III MANUAL SERVICE

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Panel Mounted Fault Annunciator Series

Operation and use. Functions and characteristics

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Silent Alert Fire Safe System

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SCAN200E USER S MANUAL

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Building Technologies. FDUL221 en Line tester operating instructions for electricians

Installation, Operating and Maintenance Manual

Annunciator Unit SACO 16 D1. Product Guide

HIGH VOLTAGE A.C.(50 or 60Hz) CONTACT CAPACITIVE HIGH VOLTAGE DETECTOR

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

ANEMOMETER 4403-RF-BAT

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Panel Mounted Fault Annunciator Series

Refrigerated air dryers

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

New Silent Alert Fire Safe System

SmarTemp Control fx 2.0

1. General Safety Block diagram Description of operation Connections Commissioning...11

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

CTT8 TEMPERATURE MONITOR DEVICE

Radio fire warning panel SRC 3000

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

Annunciator unit. Application

Liberty Premium 8. User Instructions

TECHNICAL MANUAL SIRENS RF. Range of wireless sirens 869 MHz. Made in FRANCE. SIRYNX_RF Indoor siren. PILOTE_RF Interface emissor / receptor

INSTRUCTIONS. Family 4 N 4062 Issue C Date 01/2011. CMV Certification reference NF205.

MD12-1 Vehicle Loop Detector

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

MO n : 12JMC rév A

AQ 100 Series. Arc Flash Protection System

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Multi-Gas-Controller MGC2

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Audible warning devices for external alarm

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

WIDE SEARCH AREA HAND-HELD METAL DETECTION SET

DGC-1000 DIGITAL GENSET CONTROLLER

Intelligent addressable fire alarm control panel

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES

Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Batt-Safe Battery String Monitoring System

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

Product Catalogue. Safety Equipment. Capacitive Voltage Detectors and Voltage Detection Systems

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

EXPLOSION-COUNTERACTING SYSTEM «UDAR-KB» Installation Guide

Consultant Specification AGILE Wireless Fire Detection System

NEW GENERATION COMPACT HAND HELD METAL DETECTION SET

Operating Instructions

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

HGM1750 Automatic Generator Module OPERATING MANUAL Smartgen Electronics

WIRELESS MEASUREMENT SYSTEM OF GAS BOTTLES FILLING LEVEL WITH GAS LEAK DETECTION GMS 300. User Manual

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

Specifications Minimum Typical Maximum Unit

ZED UV Monitor PRO11DPI-I

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Instruction manual. Remote control electric IR HEATER

X803 ELECTRONIC CARD Control unit for generating sets OPERATING MANUAL

CONTROL DEVICE SLIDETRONIC HD

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

BSC-50 ADU-500. Autonomous RTUs

CIRCUIT BREAKER FAIL PROTECTION

WP4086 Condition Monitoring System

Carbon Monoxide Transmitter

AO Annunciator Module

DOCUMENTATION IPS640

EARTH FAULT METER MD-08

DOCUMENTATION IPS640

Sirius Technologies, Inc.

Analog Annunciator Unit SACO 16 A3. Product Guide

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

PD140N NEW GENERATION COMPACT HAND HELD METAL DETECTION SET. Threat Detection through Electromagnetics. NIJ Compliant.

VAMP 121. Arc protection unit. User manual

Transcription:

SENTINEL A - Fault Passage Indicator AMPEREMETRIC FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-A range allows locating the fault arisen on the MV network, whether they are single phase to earth, multi-phase, transient or permanent. It allows identifying quickly the failing section of network, by suppling : A blinking light for the permanent fault. A counting of all events (transient or permanent). The Sentinel-A is an amperemetric fault passage indicator (FPI) adapted to the MV overhead lines (fault current always higher than capacitive current) : Network with impedance earthing. Network with direct earthing. > DESCRIPTION FRENCH PRODUCTION Enedis APPROVED Functioning Amperemetric detection The Overhead Sentinel-A measures the electromagnetic field and the electric field supplied by the overhead line. The sensor integrated in the indicator provides an image of the residual current. Other sensors provide an image of the line current flowing in the power grid and an image of the residual voltage. Fault is detected when its value exceeds an adjustable threshold (homopolar residual current or phase current) for a fixed period. 1

> FAULT LOCALIZATION Single phase earth faults The single-phase earth faults are indicated with only one color light. Only detectors located between the high voltage station and the defect flash. The fault is located on the network section between the last FPI whose flashes and the first whose is not flashing To HV-MV Substation Downstream fault Service Upstream fault Dual and multi-phase faults They differ from other defects by double colors (alternating Red and Green). Only detectors located between the high voltage station and the defect flash. The fault is located on the network section between the last FPI whose flashes and the first whose is not flashing. To HV-MV Substation Downstream fault Upstream fault Service 2

> SIGNALLING FAULTS Flashing information The information of the presence of a fault that led to the definitive trip of feeder is indicated locally by a LED. The signalling is performed at a rate of one flash per second : Red flash in the event of a single-phase fault Alternately red flash and green flash in the event of a multi-phase fault or double fault to earth Relay dedicated to remote control Two relay outputs (dry potential free contacts) copy the light signalling. These contacts (NO) allow to bring back fault information to an external application. These contacts are activated for 100 ms to the appearance of transient fault then, if the fault becomes permanent, the contacts are activated for the duration of the light signalling. Relay of alarm «Equipment fault» A third relay output provides to an external application, information on the correct operation of the fault passage indicator. Two dry contacts («normally open» and «normally closed») are activated from the loss of supply of the fault passage indicator (end of autonomy of the rechargeable element - ultra capacitor - end of battery life) or in the event of processor failure (watchdog). It indicates that the detector is no longer operational : the NO contact opens the NC contact closes > HUMAN MACHINE INTERFACE The Overhead-Sentinel-A, in addition with its functions of detection and signalling, counts and returns the number of transient faults, semi-permanent and permanent of different types (single phase and multi phase). A «human-machine interface» consisting of a display and push buttons allows the user: Consultation of clear messages. Visualization of 3 fault counters. Configuration of different parameters and setting thresholds. METER READING In option, a bluetooth radio remote control to access and configure the Overhead-Sentinel-A is available. It is fitted with the same keyboard than the local keyboard of the detector. Of a range of about twenty meters, remote control provides access to the same menu as the local display. It facilitates the configuration and consultation counters : Without leaving the vehicle. In inaccessible places. When the detector is installed at more than 2 m high. It uses standard batteries (2 LR06 alkaline AA 1.5V). 3

> INSTALLATION The Overhead-Sentinel-A is designed to be installed on electric poles of overhead lines. The supports can be concrete, wood or metal. The box is fixed to the pole height between 3 m and 6 m (5 m being the default position). The height between the floor and the lowest of the line wire shall be between 7 m and 14 m. The pole must be free of all vegetation high on a radius of 3 meters around the support. Warning : To maintain its sensitivity, the Overhead- Sentinel-A should not be installed : Less than 50 m from another MV line. Less than 200 m from HV line (<100kV) or railway. Less than 500 m from HV line (>100kV). Less than 50 m from an overheadunderground connection. 7 to 14 m Warning : The Overhead-Sentinel-A should not be installed in the following cases : On cross supports. On overhead-underground connection. On mix supports (with multiple networks HV, LV). 3 to 6 m The Overhead-Sentinel-A must be installed at the center of the pole in the center of the overhead line : Special case For the use of Overhead-Sentinel-A on a double support, the detector must be installed on a crossbar between two poles. 4

> POWER SUPPLY The Overhead-Sentinel-A fault indicator is powered by ultra capacitor charged with solar panels. It does not require any replacement. This version is equipped with a switch in order to turn off the current of the indicator if necessary. Warning : When commissioning, the ultra capacitor of the overhead Sentinel A indicator needs to be charged. In order to do so, 2 solutions are available : Place the overhead Sentinel A in full sun for at least 2 hours before commissioning (depending on the weather) Use the quick charge with the micro USB connector : - By plugging a standard phone charger (the charger must supply a voltage of 5 V and a current greater or equal to 500 ma). This charger could be connected to the power supply or on a 12 V cigarette lighter socket. - By plugging the indicator on the USB interface of the PC (with a USB-A cable / micro USB) Charging time will be about 20 minutes. While charging, a red flash lights up and turns off at the end of the process. > OPERATION Display of fault counters The buttons " " and " " allow scrolling the display of 2 fault counters. Once these were read, the user has the ability to perform their reset. In addition to the default counters, the Overhead-Sentinel-A indicates the time since the last increment of each counter. This additional information : allows to know, after the extinction of the signals, if the Overhead-Sentinel-A has seen the fault. provides assistance for preventive maintenance of the HV line. When an unusual increase in the number of transient faults occurs, the Overhead-Sentinel-A provides valuable information on the section of the HV network causing these transient faults. With fault counters and this time information, it is possible to know which fault passage indicators have seen these faults and so, to identify the fault location before it causes a definitive trip. Example of using the fault counters to find the section causing transient faults. With timers, it is easy to identify the faulty section : HV Substation «Poly» (Multi-phase) Meter : 4 0 Day 1h51 min «Poly» (Multi-phase) Meter : 11 1 Year 163 Day «Poly» (Multi-phase) Meter : 15 0 Day 1h51 min «Poly» (Multi-phase) Meter : 8 120 Day 08h15 min 5

METER READING Press on OK Fault display While fault searching, the alphanumeric display can provide the operator, additional assistance by indicating clearly the type of fault, "multiphase", "double", or " phase ". The fault is stored as long as the MV voltage is absent. MULTIPHASE METER : 4 O J 1 H 51 MIN Press on or RED METER : 12 20 J 12 H 36 MIN Press on or METER READING : 8 RAZ Meters? Press on or Press on OK Press on OK In the absence of fault, the Overhead-Sentinel-A indicates the presence or absence of MV voltage. OK RAZ meters AUSCULTATION Press on OK AUSCULTATION Present voltage Charge level of the ultra-capacitor (depending on model) Use this menu to check the charge level of the ultra-capacitor associated with photovoltaic panels. CHARGE CAPACITOR Press on OK CHARGE CAPACITOR Charge = 85 % Status of the fault passage indicator The «fault passage indicator status» menu allows for a diagnosis in an event of equipment failure of Overhead-Sentinel-A. INDICATOR STATUS Press on OK INDICATOR STATUS Indicator OK 6

> ELECTRICAL CHARACTERISTICS MV NETWORK Rated voltage U N Rated frequency Detection of single- phase earth faults Detection principle Phase current detection threshold Handling time Signalling Detection of dual single phase faults Detection principle Phase current detection threshold Handling time Signalling Detection of multi-phase faults Detection principle Phase current detection threshold Handling time Signalling Time delays Before a fault is counted (T delay) Before the indication of a permanent fault (T permanent) Voltage MV presence for «setting» the detection of single phase faults MV voltage return for clearing the current fault Indication External indicator light External contact Indication stopped Clearing the fault Through MV voltage return Voltage level Delay Stop of signalling with fault ever stored Through a front panel pushbutton Automatically after a time delay Until 36 kv 50 Hz Amperemetric (threshold exceedance for a period) 20, 30, 40, 50, 60, 70, 80, 90, 100, 120, 140, 160, 180, 200, 220, 240 A 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 280, 300, 400,500 ms RED Amperemetric (threshold exceedance for a period) 250, 300, 350, 400, 450, 500, 600, 700 A 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 280, 300, 400, 500 ms RED and GREEN Amperemetric (threshold exceedance for a period) 250, 300, 350, 400, 450, 500, 600, 700 A 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 280, 300, 400, 500 ms RED and GREEN 340 ms, 800 ms or 3 sec 1 sec, 10 sec, 20 sec ou 70 sec 5 sec 5 sec High brightness flashing LEDs Closing dry contact 0.5 Un 5 s 2h, 4h, 12h, 24h 7

> ENVIRONMENTAL CONDITIONS NORMS Mechanical Dimensions (W x H x D) Protection rating NF EN 60529 NF EN 62262 Vibrations NF EN 68068-2-6 320 x 260 x 140 mm IP 54 IK 09 Acceleration : 2g/ displacement : 0,15 mm (peak value) - 10 Hz to 500 Hz Climatical Operating temperature NF EN 60068-2-1 NF EN 60068-2-2-25 C to + 55 C Storage temperature NF EN 60068-2-14-40 C to + 70 C Relative humidity NF EN 60068-2-3 Tests Ca - 93% à 40 C 96h closed box, 4h opened box Salt mist NF EN 60068-2-11 178 h Dielectric strength Input voltage 12 V and dry contact ouputs compared to the box CEI 60255-5 2 kv - 50 Hz (1 mn) 5 kv shock (1,2/50 µs) Electromagnetic Dampened oscillating waves NF EN 61000-4-12 Fast transients NF EN 61000-4-4 Shock waves NF EN 61000-4-5 Electrostatic discharges NF EN 61000-4-2 Electromagnetic field-amplitude NF EN 61000-4-3 2.5 kv un common mode (100 khz et 1 MHz) 1 kv in differencial mode (100 khz et 1 MHz) 4 kv on power circuits 2 kv on other circuits 1 kv coupling between wires 2 kv coupling wire /ground Harshness 4 (8 kv contact discharge, 15 kv air discharge) 10 V / m 27 MHz to 6 GHz Power supply Battery self-sufficiency 3 lithium batteries 13Ah format D (not included) External supply 12V DC 12 V + 30% - 10% Solar panels save by ultra-capacitor 2.5 V maintenance free (15 years) MEDIUM VOLTAGE DIVISION CRDE, a society of Groupe CAHORS ZI des Grands Camps - BP 9 46090 Mercuès - FRANCE Tél. +33 (0)5 65 30 38 10 Fax +33 (0)5 65 20 09 17 Réalisation : Service Marketing - 09/18 8