Operation Manual. Instructions for Installation, Operation & Maintenance. PortaPac 5-, 8 and 10-ton Portable Air Conditioners

Similar documents
WIRING DIAGRAM. This manual describes the unit features and explains how to set-up, operate and maintain these AirPac Models. COOLIT2600 COOLIT2900

OPERATION MANUAL. CLASSIC PLUS 14 and CLASSIC PLUS 26 ~ SECTION EN FRANÇAIS

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

OPERATION MANUAL U L US LISTED OFFICE PRO 36 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT IN- STALLATION AND USAGE, AND READ ALL SAFEGUARDS.

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

T-Series Air Conditioner T20 Model

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

OPERATIONS MAINTENANCE MANUAL

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

XC Portable Air Conditioning

Quest Power Electric Heat EHS 31 Pro

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Quest Power Electric Heat EHS 62 Pro

T-Series Air Conditioner T15 Model

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

Installation & Maintenance Instructions

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

OPERATION MANUAL U L US LISTED CM12 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts

Owner s Manual Phoenix FireBird

Quest Dry 105, 155, and 205 Dual

MANUAL FOOD HOLDING & TRANSPORT CABINETS WITTCO MODEL NUMBERS

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

POLARIS Portable Water-Cooled Spot Cooler ENGINEERING, INSTALLATION AND SERVICE MANUAL PWC60 PWC12. R22 Models

PAC series Portable Air-Cooled Spot Cooler

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

User s Manual and Operating Instructions

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18. Unit Serial Number Range: 1111XXXX### to Present (From November 2011 to Present)

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

OFFICE PRO 63 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE AND READ ALL SAFEGUARDS

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

T-Series Air Conditioner T53 Model

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Superdryer Dehumidifiers

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Quest 105, Dry155, and 205 Dual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

IMPORTANT SAFETY INFORMATION:

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

48 MaxxAir Portable Evaporative Cooler Owner s Manual

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL

AIR CONDITIONER ELECTRONIC CONTROL

Power Pack Service Manual

INSTALLATION AND SERVICE MANUAL

Power Pack Service Manual

OPERATIONS FOOD HOLDING & TRANSPORT CABINETS. wîttco foodservice. equipment

POWER PACK SERVICE MANUAL

SLIDER CASEMENT AIR CONDITIONER

INSTALLATION & OPERATING INSTRUCTIONS FOR CEILING MOUNT AIR HANDLERS AC SERIES

POWER PACK SERVICE MANUAL

HB CDA SERIES WITH TEMPERATURE SETBACK

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

INSTALLATION AND SERVICE MANUAL

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

ion Genesis Pump Controller

Owner s Manual Models: TC-12B - TC-60B4, Digital Thermostat

5) Do not start or stop the unit by inserting or pulling out the power plug.

Instruction Manual Item No.: V~, 60Hz

INSTRUCTIONS! DO NOT DISCARD!

Insulated Ventilators. Operating Instructions & Parts Manual

Panel Fan Series Operators Manual (Galvanized and Polymer)

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

Installation and Owner Man u al

User s Manual & Operating Instructions

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

INSTRUCTIONS! DO NOT DISCARD!

Surna 25-Ton Chiller Operating & Maintenance Manual

RPI Industries, Inc.

Installation & Maintenance Instructions

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Transcription:

Operation Manual PortaPac 5-, 8 and 10-ton Portable Air Conditioners A AirPac, Incorporated AirPac Technology Park 888 Shenandoah Shores Road Front Royal, Virginia 22630 U.S.A. Toll Free 888-324-7722 Web: airpacinc.com email: portapac@airpacinc.com Instructions for Installation, Operation & Maintenance 2000 AirPac, Incorporated Printed in U.S.A. Manual PP005.INSTR The Coolest Site on the Web airpacinc.com

WARRANTY AirPac warrants to its authorized distributor, each new PortaPac to be free from defects in material and workmanship for a period of one (1) year from date of installation or eighteen (18) months from date of delivery to distributor, whichever occurs first. The compressor(s) has a limited warranty of three (3) years from date of installation. Limitations: This warranty shall not apply to nor include any of the following: 1. Any repair or replacement required as a result of accident, misuse, lack of proper maintenance, incorrect wiring, repairs improperly performed or replacements improperly installed by any person, or use of a replacement part or accessory not conforming to specifications of AirPac. 2. Any repair or replacement required as a result of normal wear and tear. 3. Any consequential, incidental, special, or exemplary damages. 4. Replacement of belts, pulleys, and filters. 5. Any unit which has its serial numbers altered, defaced or removed. The sole obligation of AirPac under this warranty will be to furnish, without charge, a replacement part for a defective part. This warranty does not include installation, transportation, or postage costs associated with installing the replacement part. In order for this warranty to become effective, the warranty registration card, delivered with the unit, must be completed and returned to AirPac within 30 days of purchase and delivery. Any claim under this warranty should be first presented to and processed by the authorized distributor from whom the equipment was purchased. To the extent permitted by law, this warranty is expressly in lieu of any other warranties, either expressed or implied, made by AirPac, Incorporated. AirPac assumes no liability in any event for lost profits, or any consequential damages of any kind arising from breach of this warranty. 19

APPLICATION TIPS Some tips and tricks we hope you ll find helpful. If you have any suggestions, please let us know. To make the unit easier to maneuver you can add some handles to either side. Keep duct runs as straight as possible to get the maximum air delivered. Attach a fused disconnect to the unit and hardwire to the disconnect instead of the unit. A remote thermostat (24V) can be added easily by running wires into the top of the electrical panel and connecting to R - T- Y1 (Y1&Y2 on 8 and 10 ton models). IMPORTANT READ BEFORE YOU PROCEED When you receive your AirPac shipment be sure to inspect the packaging for visible damage. KEEP ALL ORIGINAL PACKAGING MATERI AL. ORIGINAL PACKAGING MATERIAL IS REQUIRED WHEN FILING A DAMAGE CLAIM FOR CONCEALED DAMAGE. Inspect all shipping cartons for visible shipping damage. You must document damage with the shipper. Call your AirPac Distributor immediately to report shipping damage. Your AirPac Distributor will advise you how to proceed with the shipping claim. 18

FORWARD Thank you for purchasing the AirPac PortaPac portable air conditioner. This manual describes the unit features and explains how to set-up and operate the PortaPac. Preventative maintenance procedures are outlined and a trouble-shooting guide is provided for your reference. Please read this operation manual thoroughly to familiarize yourself with the features of the unit and to ensure years of trouble-free operation. We would like to ensure your satisfaction with the PortaPac family of products. If you have questions or require additional information please WARNING: Describes precautions that should be observed in order to prevent injury to the user during installation. CAUTION: Describes precautions that should be observed in order to prevent damage to the unit or its components, which may occur during installation or unit operation if proper care is not exercised. NOTE: Provides additional information that facilitates unit operation. Y1 Y2 G R WIRING DIAGRAM 8-Ton PAC96 & 10-Ton PA20, Three Phase R1A S2 S3 R1 R2A S4 S5 C4 C4 C R2 CFM EFM COM1 COM2 *TRF C4 C C4 S1 T = EVAPORATOR FAN CONTACTOR = COMPRESSOR #1 CONTACTOR = CONDENSER FAN CONTACTOR C4 = COMPRESSOR #2 CONTACTOR C = COMPRESSOR #1 CRANKCASE HEATER C = COMPRESSOR #2 CRANKCASE HEATER CFM = CONDENSER FAN MOTOR COM 1 = COMPRESSOR #1 COM 2 = COMPRESSOR #2 EFM = EVAPORATOR FAN MOTOR R1 = COMPRESSOR #1 LOCK-OUT RELAY R1A = COMPRESSOR #1 LOCK-OUT CONTACTOR R2 = COMPRESSOR #2 LOCK-OUT RELAY R2A = COMPRESSOR #2 LOCK-OUT CONTACTOR S1 = AIR SWITCH S2 = COMPRESSOR #1 LOW PRESSURE SWITCH S3 = COMPRESSOR #1 HIGH PRESSURE SWITCH S4 = COMPRESSOR #2 LOW PRESSURE SWITCH S5 = COMPRESSOR #2 HIGH PRESSURE SWITCH TRF = 24 VAC TRANSFORMER * TRANSFORMERS FOR 208/230 UNIT WIRED VOLT FOR 208 VOLT FOR 230 OPERATION. VOLT OPERATION, AND TAPE DISCONNECT 208 VOLT WIRE AND WITH 230 VOLT REPLACE WIRE. A I R P A C Dual Stage, 3 Phase DESCRIPTIONWiring Diagram : PART #: DIA-103 L1 L2 208/230/3/60 L3 MATERIAL: DATE: 02/28/94 APPROVED BY: ARB 460/3/60 17

WIRING DIAGRAM TABLE OF CONTENTS 5-Ton PAC60, Three Phase Y 1 G R R1A S2 S3 CCH R1 CFM *TRF S1 T - EVAPORATOR FAN CONTACTOR - COMPRESSOR CONTACTOR - CONDENSER FAN CONTACTOR CCH - CRANKCASE HEATER CFM - CONDENSER FAN MOTOR COM - COMPRESSOR EFM - EVAPORATOR FAN MOTOR R1 - LOCK-OUT RELAY R1A - LOCK-OUT RELAY CONTACT S1 - AIR SWITCH S2 - LOW PRESSURE SWITCH S3 - HIGH PRESSURE SWITCH TRF - 24 VAC TRANSFORMER Introduction... 6 Equipment Check List... 7 Inspection of Equipment... 8 Unit Overview... 9 Preparing Unit for Operation...10 Exhaust Kit Installation...13 Control Panel Functions...16 Unit Operation...18 Condensate Pump Installation...21 Maintenance...23 Specifications...24 Wiring Diagram...25 Parts Diagram...26 Parts Listing...27 Troubleshooting Guide...28 Warranty...30 COM EFM * TRANSFORMERS FOR 208/230 VOLT UNIT WIRED FOR 208 VOLT OPERATION. FOR 230 VOLT OPERATION, DISCONNECT AND TAPE 208 VOLT WIRE AND REPLACE WITH 230 VOLT WIRE. A I R P A C L 1 208/230/3/60 460/3/60 L 2 L 3 DESCRIPTIONThree Phase Wiring : PART #: DIA-102 MATERIAL: DATE: 02/28/94 APPROVED BY: ARB 16

INTRODUCTION The versatility of the AirPac PortaPac is adaptable for cooling various applications. The horizontal systems are designed to install in the ceiling so you do not lose valuable floor space. WIRING DIAGRAM 5-Ton PAC60, Single Phase The PortaPac series is manufactured with quality materials and is designed to give you many years of reliable, trouble-free service. The PortaPac series features: Y1 R1A S2 S3 R1 - EVAPORATOR FAN CONTACTOR - COMPRESSOR CONTACTOR Sturdy cabinets with integral mounting rails Compact size Wide range of capacities Over-sized motors and blowers for up to 1.5 ESP on both the evaporator and condenser Pre-charged in the factory for packaged installation Quick-connect valves for no loss of factory charge when installed as a split system Removable panels for easy service and maintenance G S1 - CONDENSER FAN CONTACTOR CCH - CRANKCASE HEATER CFM - CONDENSER FAN MOTOR COM - COMPRESSOR CPR - CAPACITOR EFM - EVAPORATOR FAN MOTOR R1 - LOCK-OUT RELAY Before installing and operating your PortaPac system, please read the instructions carefully to ensure maximum benefit from your portable air conditioner. R *TRF T R1A - LOCK-OUT RELAY CONTACT S1 - AIR SWITCH S2 - LOW PRESSURE SWITCH S3 - HIGH PRESSURE SWITCH EFM TRF - 24 VAC TRANSFORMER CCH * TRANSFORMERS FOR 208/230 VOLT UNIT WIRED FOR 208 VOLT OPERATION. FOR 230 VOLT OPERATION, DISCONNECT CFM AND TAPE 208 VOLT WIRE AND REPLACE WITH 230 VOLT WIRE. CPR COM A I R PA C DESCRIPTION: Single Phase Wiring PART #: DIA-101 MATERIAL: L1 208/230/1/60 L2 DATE: 02/28/94 APPROVED BY: ARB 6 15

MAINTENANCE Evaporator and Condenser Coils - It is important to keep the face of the evaporator and condenser coils clean. A dirty evaporator coil will reduce unit capacity and eventually cause the unit to shut down by activating the low pressure control safety. A dirty condenser coil will cause high condensing pressures which results in higher power consumption, or the high pressure safety control will be activated and cause system shut down. TROUBLESHOOTING Check the points below when troubleshooting SYMPTOM POSSIBLE CAUSE POSSIBLE REMEDY Unit does not operate 1. No power applied 2. Incorrect voltage applied - Check power - Check voltage with meter EQUIPMENT CHECK LIST The first step in preparing the PortaPac for installation is to run through this check list to ensure you have all the pieces necessary for your installation. Your equipment is shipped by common carrier. The equipment is on sturdy wooden pallets and the units are covered with either cardboard boxes or vinyl tarps. Your shipment will consist of one pallet per unit ordered. If you purchased optional accessories they will be packaged separately and may be shipped with the unit or by another delivery method. Your packing list is attached to the outside of the packaging in a plastic pouch. Please consult the packing list to determine if your shipment is complete. Optional accessories available with the PortaPac include: POWER Lamp off 1. No power applied 2. Defective lamp - Check power - Check POWER lamp 1. Evaporator Plenum 2. Flange/clamp assembly No Cooling Cool lamp off No Cooling Cool lamp on 1. Air switch override 2. Defective contactors 3. Defective relay 1. Defective contactor 2. Defective relay - Check evaporator air switch - Check contactors - Check relays - Check contactors - Check relays 3. Return Air Assembly 4. Flex ducting 5. Fabric poly ducting Water overflow 1. Blocked condensate drain 2. Unit left out in rain - Clean drain and lines - Remove excess water Insufficient cooling 1. Blocked air intakes 2. Dirty filters 3. Time delay setting 4. Loose V-belts Excessive vibration 1. Unit not level 2. Loose mounts - Check filters - Clean filters - Check time delay settings - Check V-belt tension - Level unit - Check motor mounts If symptoms still persist after applying remedy, turn control switch to OFF, disconnect power, and contact your local service center or AirPac s Service Department at 1-800-457-7127. 14 7

GENERAL WARNINGS Your safety when operating AirPac equipment is of paramount importance. Please review these warnings to ensure safety. All electrical work, if necessary should be performed by licensed and qualified electrical personnel. Repair to electrical components by non-certified technicians may result in personal injury and/or damage to the unit. By design, all electrical components are available from your local supply house but please contact AirPac if you have questions or require additional information. All PortaPac equipment must be hardwired and should be installed with a UL approved ground-fault breaker to prevent electrical shock. Doors and access panels are not screwed shut to enable easy access in the field. If the equipment is operating in an area where unauthorized personnel may attempt to access internal components, you may want to consider securing the access panels to restrict unit access by unauthorized personnel. Connect to the proper electrical voltage. Connecting to the wrong voltage can cause damage to the unit and may result in personal injury. Always check the voltage source with a volt meter or reliable source to make sure the proper voltage is being applied. SET UP AirPac PortaPac is versatile and can be used in a variety of installations. Most installations require - Power Connection, Drain Connection and Air Duct Connections. Select a level surface that can withstand the weight of the unit. Secure the unit by blocking the wheels to prevent movement. WARNING: Failure to secure the unit can cause personal injury or equipment damage. POWER CONNECTION Use only the proper AC power required. Make sure power is disconnected before connecting to the unit. Do not connect or disconnect the power or operate any switches with wet hands. Make sure the electrical circuit is properly protected with fuse or circuit breaker protection and that all necessary ground wires are connected. MAINTENANCE Your PortaPac is designed and built with reliable components to provide years of troublefree dependable service. Regular Maintenance Schedule DAILY WEEKLY MONTHLY YEARLY Air Filters X X X X Condensate Pump X X X X Belts X X X X Blowers X X Refrigerant Site Glass(es) Coils Air Filters - It is important to check filters and replace as necessary. The air filter material used in the PortaPac is a poly mat - suitable for harsh and even wet locations. It can be cleaned with water and reused. Replacement filter pads are available through most well stocked hardware stores. Condensate Pump - Inspect drain lines and pump after each use to insure free flow of condensate. Clean as necessary. Belts - Inspect and check for wear and correct tension. If the two legs of the belt pressed in midpoint results in 1 to 1-1/2 movement then the tension is good. Blowers - Check that the blower wheel is tight on the shaft and does not contact the housing. Bearings are permanently sealed but should be checked periodically for signs of wear. Check for restrictions or foreign material in the air circuit. Refrigerant Site Glasses - If bubbles appear in the sight glass, the circuit may either be undercharged or there may be a restriction in the liquid line upstream of the sight glass. The sight glass also contains a moisture indicator which changes color when moisture is present in the system. X X X 8 13

OPERATION Before operating the unit, familiarize yourself with the basic controls and their operation. Listed below in the control panel and its configuration. Power Indicator Cooling Indicator Control Switch FAN COOL OFF Power Indicator: Illuminates when electrical power is supplied to the unit. Amber LED Cooling Lamp: Illuminates when the cooling stage is active (on). Green LED Control Switch: Select desired operating mode. (Fan - Off - Cool). Three position toggle. CAUTION: OPERATING MODES POWER Make sure the control switch is in the off position whenever connecting or disconnecting power to the unit. Move the control switch (3 position toggle) to FAN. The unit will circulate air in the evaporator section only. The condenser fan will not operate in this mode. Move the control switch to COOL. The unit will begin cooling in approximately 2-3 minutes (time delay factory setting). The green COOLING indicator will illuminate when the compressor is on. Automatic Restart Feature COOL A If there is an interruption of electrical power or a high or low pressure safety is activated while in the FAN or COOL mode, the unit will automatically restart upon return of electrical power. SET UP NOTE: When connecting to three phase power be sure to check the rotation of the fan motors before operating the unit. If the blower rotates in the opposite direction, phase sequence of the power source is reversed. To correct, disconnect power and change any two of the power legs from the power source. DRAIN CONNECTION Make sure the unit is set on a level surface or is leveled to ensure proper condensate removal. Connect the drain to the output of the condensate pump or by-pass the pump and connect directly to the condensate pan outlet. The condensate pump has a head of 20. AIR DUCT CONNECTION Ducted Supply - Free Return This method is commonly used for tents, factories, or temporary work spaces, or any open area where the air return can be directly from the area you are trying to cool. Ducted Supply - Ducted Return In certain applications it may be necessary to duct the return air to the unit. For example, when the A/C is remote from the area to be cooled. Ducted return air can be done by adding the optional return air flange assembly and flexible duct as needed. Condenser Air Exhaust & Condenser Supply Ducting In some installations it may be necessary to duct the condenser air intake and condenser exhaust. The PortaPac is built with powerful blowers to handle duct runs on both sides. Duct work can be fitted to the condenser air intake or exhaust as needed and optional accessories from AirPac make it easy. CAUTION: When using flexible duct. Flexible duct is convenient and typically has a high compression ratio, however it can also greatly restrict air flow when improperly installed. Observe all warnings and instructions when using flexible duct. If air flow is restricted possible damage can occur. 12 9

UNIT FEATURES Please take a few minutes to familiarize yourself with the AirPac PortaPac. Evaporator Supply Evaporator Return Control Panel UNIT FEATURES Evaporator Supply: This is the cold air supply. The evaporator supply should be ducted to ensure proper delivery of cool air. You can use the optional evaporator supply flange and attach field duct work or connect to an existing duct work system. NOTE: The optional poly plenum used with the poly diffuser duct is the most desirable air distribution method for rental and temporary applications. The poly material allows the greatest flexibility for installation, is washable so it can be used repeatedly and folds for easy transport and storage. Casters Condensate Drain Evaporator Return: This area must be kept clear so airflow is not restricted. Return is fitted with filters to keep coils clean. Return can be ducted - see AirPac optional accessories. Control Panel: Panel for the OFF - FAN - COOL selector switch with power and cool indicator lamps. Electrical Panel / Power Connection: High voltage power connection and access to all relays, contactors and electrical controls behind panel. Casters: Heavy duty industrial casters. Low profile, dual wheel, swivel casters for ease of mobility. Power Connection Electrical Panel Condensate Pump Outlet Condenser Discharge Condenser Supply Condensate Pump Outlet: Remove front panel to access condensate pump. Outlet is 3/8 ID tubing. Pump is automatic and has 20 head. Pump only operates in FAN or COOL mode. Condensate Drain Outlet: Pump can be by-passed and condensate can be removed by gravity flow. Outlet is available directly under the evaporator coil. Condenser Discharge: Area must be kept clear. Move adjustable vanes to direct exhaust air away from personnel and condenser supply. Discharge can be ducted - see AirPac optional accessories. Condenser Supply: Fitted with filters, this area must be kept open to allow air supply to the condenser. Supply can be ducted - see AirPac optional accessories. 10 11