CENTRIFUGAL FANS user's manual. model VENTS VK.

Similar documents
INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

INTELLIGENT AXIAL FAN user's manual

AXIAL FANS USER S MANUAL

AXIAL DOMESTIC FANS. User manual LARUS LIBELLA FENESO CYCNUS CICONUS SIGILA SIGILA MOTION

AXIAL FANS user's manual. model Quiet

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

Turbo. Service Instructions

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Wind. Service instruction

Aero. Service Instructions

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Calm. Service Instructions

USER S MANUAL. VKP Series INLINE FAN

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

Centrifugal inline fans

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

Axial intelligent fan USER S MANUAL

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

HEAT RECOVERY AIR HANDLING UNIT

CENTRIFUGAL CEILING EXTRACT FAN

CENTRIFUGAL CEILING EXTRACT FAN

Air handling unit. BlauAir RH USER S MANUAL

HEAT RECOVERY VENTILATOR

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Turbo Inline Fan, White - Non Illuminated Art no.33500

USER S MANUAL DN-2. Drain pump

White - Non Illuminated Art no White - Cool White LED Art no.32600

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

AIR HANDLING UNIT WITH HEAT RECOVERY

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

USER'S MANUAL PS

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Installation manual Mini Comfort 50 S/L 07/ V EN

USER'S MANUAL INLINE CENTRIFUGAL FANS IN SOUND-INSULATED CASING VS, VS EC SERIES

USER S MANUAL AiR duct heater with integrated temperature control UNit or A control UNit

PH1000T PH1500T PH2000T

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

Centrif Duo & Centrif Duo Plus

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

"Microbox" Continuous Mechanical Extract Ventilation Units. Installation, Operating and Maintenance Instructions

Lo-Carbon Quadra Centrifugal Fan

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

USER S INFORMATION MANUAL

KKKKKKKCOOKER HOOD INSTRUCTION MANUAL

Remote Tower Fan USER INSTRUCTIONS. Product Code: MY146. IMPORTANT Installers and Users please note:

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

IMPORTANT SAFETY INFORMATION:

IMPORTANT INSTRUCTIONS READ & SAVE

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

AH-600 Baseboard Heater

IMPORTANT INSTRUCTIONS READ & SAVE

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

40E ELECTRIC FAN HEATER

Electric Garage Heater

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

USER S INFORMATION MANUAL

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Operating and Installation Instructions

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

breeze easytm model # F100-1W

Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M

Electric Garage Heater

Classic Electric Stove

Cooker Hood LA-72-CAN.

Series VENTS VUT R WH ЕС

Low Profile. Baseboard Heater

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

CYLINDER NOT INCLUDED

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Installation Guide ULTRA-SAUNA HEATER. Proudly made in USA since 1964 SMALL HEATERS KW. Installation Instructions & User Manual

IMPORTANT SAFETY INFORMATION:

Hardwired Electric Garage Heater

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

FAN-FORCED UTILITY HEATER

Transcription:

EN CENTRIFUGAL FANS user's manual model VENTS VK www.ventilation-system.com 2013

EN! WARNING! Disconnect the fan from power mains prior to any connection, servicing and repair operations. Mounting and maintenance are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the user's manual. The single-phase power mains must comply with the acting local electrical norms and standards. The fixed electrical wiring must be equipped with an automatic circuit breaker. The fan must be connected to power mains through an automatic circuit breaker QF integrated into the fixed wiring system with the gap between the breaker contacts on all poles not less than 3 mm. Check the fan for any visible damages of the impeller and the casing before starting installation. The casing must be free of any foreign objects that could damage the impeller blades. Misuse of the device or any unauthorized modifications are not allowed. The fan is not to be used by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation by the person(s) responsible for their safety. Do not leave children unattended and do not let them play with the product. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. Transported medium must not contain any dust or other solid impurities, sticky substances or fibrous materials. Do not use the fan in the environment containing hazardous or explosive materials and vapours, i.e. spirits, gasoline, insecticides, etc. Do not close or block the fan intake or extract vents in order to ensure the most effective air passage. Do not sit on the fan and do not put objects on it. Fulfil the requirements stated in the user's manual to ensure long service life of the product. Recycle at the end of the service life. Do not dispose the product with unsorted municipal trash. 2

Read the present user's manual carefully before proceeding with installation works. Compliance with the manual requirements ensures reliable operation and long! service life of the product. Keep the user's manual available as long as you use the product as it contains information on the product servicing. WARNING! EN DELIVERY SET The delivery set includes: 1. Fan - 1 item; 2. Screws and dowels - 4 items; 3. Fixing bracket - 2 items; 4. User's manual; 5. Packing box. BRIEF DESCRIPTION The product described herein is a centrifugal fan for supply and exhaust ventilation of premises heated in cold season. The fan is designed for connection to 100, 125, 150, 200, 250 and 315 mm air ducts. The model with O 150 mm spigot is compatible both with O 150 mm and O 160 mm air ducts. - VENTS VK XXX - basic model. - VENTS VKS XXX - fan with a high-powered motor. - VENTS VK XXX Q - fan with a low-powered and low-noise motor with low energy demand. - VENTS VK XXX R - fan with a power cable, fig. 10. - VENTS VK XXX U (U1) - fan with a speed controller and electronic thermostat, equipped with a built-in temperature sensor and a power cable with adapter, fig. 11. - VENTS VK XXX Un (U1n) - fan with a speed controller and electronic thermostat, equipped with an external temperature sensor fixed on 4 m cable, a power cable with adapter, fig. 11. - VENTS VK XXX P - fan with a speed controller and a power cable with adapter, fig. 12. XXX - spigot diameter. Due to constant improvements the design of some models may slightly differ from those ones described in this manual. 3

EN OPERATION GUIDELINES The fan is designed for connection to AC single-phase 220...240 V, 50/60 Hz power mains. The fans models VK 315 / VKS 315 are designed for connection to 220...240 V, 50 Hz power mains. The fan is designed for continuous operation always connected to power mains. Air flow direction in the system must match the pointer direction on the fan casing. Ingress protection rating against access to hazardous parts and water ingress- IP X4. The fan is rated for operation at the ambient temperature ranging from +1 C up to +45 C. Transported air temperature: - VK 100/ VK 100 Q/ VK 125/ VK 125 Q/ VK 150: from -25 C up to +55 C; - VK 200/ VK 250/ VK 250 Q/ VK 315: from -25 C up to +50 C; - VKS 200/ VKS 315: from -25 C up to +45 C. The fan requires no grounding. ELECTRONICS OPERATING LOGIC The VK U (U1) model, fig. 11 is equipped with an electronic speed controller with electronic thermostat TSC for automatic speed control (air flow regulation) depending on air temperature. The terminal compartment incorporates 2 control knobs: - for setting the motor speed; - for setting the electronic thermostat set point. The thermostat operation light indicator is located on the fan cover. To set the thermostat threshold rotate the thermostat control knob clockwise to increase or counterclockwise to decrease the temperature set point. To set the fan speed (air capacity) rotate the speed control knob in the same way. The fan has a temperature-based and timer-based control logic. - temperature-based control logic (VK U): to maintain air temperature with accuracy to within 2 C. The fan changes its speed rarely. As air temperature rises up to the set thermostat point, the fan switches to high speed. As air temperature drops down 2 C below the set thermostat point or if the initial air temperature is 4

EN - timer-based control logic (VK U1): to maintain air temperature with high accuracy. The fan changes its speed more often as compared to the previous control logic, but the minimum operating time at one speed is not less than 5 minutes. As air temperature rises up to the set point, the fan switches to maximum speed. Synchronously, the speed switch delay timer is activated for 5 minutes. As air temperature drops down below the set point, but only after 5 minutes countdown after switching to high speed, the fan switches to lower set speed. If the initial temperature is below the set temperature point, the fan operates at low set speed from the start. The fan VK P (fig. 12) is equipped with a speed controller that enables switching the fan on/off, smooth speed (air flow) control from minimum to maximum value. MOUNTING The fan is designed for both horizontal and top installation and may be mounted on the floor or attached to the wall or to the ceiling, fig. 2. While mounting the fan provide extra protection against water ingress. The protection examples are shown in fig. 2: 1. For the top mounting position: install a protecting hood above. 2. For any mounting position: connect a straight air duct section at least 1 m long on both sides of the fan. The fan mounting sequence is shown in fig. 3-8. The fan wiring diagrams are shown in fig. 9. Wiring diagram designations: L - minimum speed terminal; QF - automatic circuit breaker; S - external switch, i.e., light switch; X - input terminal. Automatic circuit breaker designation QF External switch designation S Automatic circuit breaker External switch 1 5

EN MAINTENANCE Clean the fan surfaces regularly (once in 6 months) of dust and dirt (fig. 13-20). Disconnect the fan from power mains prior to any maintenance operations. Clean the fan with a soft cloth or a brush wetted in mild water detergent solution. Avoid liquid dripping on the electric components, fig. 41. Wipe the surfaces dry after cleaning. STORAGE AND TRANSPORTATION RULES Transportation is allowed with any vehicle provided that the fan is protected against mechanical or weather damage. Store the delivered fan in the manufacturer's original packing box in a dry ventilated premise with the temperature range from +5ºC up to +40ºC and relative humidity less than 80%. The storage environment must not contain dust, acid or alkali vapours that may cause corrosion of the product parts. MANUFACTURER'S WARRANTY The fan is manufactured at the factory of Ventilation systems PrJSC (hereinafter referred to as the Manufacturer). By purchasing this product the customer confirms to have read and agreed to the terms, rules and requirements related to operation, storage, transportation, mounting, adjustment, connection, maintenance and repair as well as warranty obligations with respect to this product as set forth in the manufacturer's accompanying documentation to the product. The manufacturing company sets forth the warranty period (service life) of the product as 24 months following the sale date via retail network subject to the customer's ensuring compliance with the rules of transportation, storage, mounting and operation of the product. In case of any malfunction of the product through the fault of the Manufacturing company within the warranty period (service life), the customer shall have the right to elimination of the manufacturing defects by means of warranty servicing performed free of charge. The warranty servicing implies performance of activities related to elimination of defects in the product aimed to provide intended use of the product by the customer. The defects are eliminated either by 6

EN NOTE! With the purpose of performing warranty servicing please submit the user's manual or other relevant substituting document and the payment document as an evidence of the purchase with indication of the sale date. The product model shall comply with that one specified in the user's manual or other relevant substituting document. With the purpose of performing warranty servicing please contact your Seller. If warranty servicing on the spot proves impossible, you will be provided with the necessary information regarding rendering of this service. Manufacturer's warranty shall not apply in the following cases: - in case the customer fails to provide the product in complete according to the package contents specified in the user's manual or other relevant substituting document, including any components disassembled by the customer; - in case of incompliance of the model or marking of the product with data specified on the product packaging and in the user's manual or other relevant substituting document; - in case of non-timely technical maintenance of the product by the customer (dust, mud, oil condensate, foreign particles); - in case of causing external damage to the product by the customer ('damage' shall not apply to external changes of the product required for the product mounting); - in case of altering the product design or further reworking of the product; - in case of replacing and using parts, units and components of the product not prescribed by the manufacturing company; - in case of other use of the product other than intended use; - in case of the customer's violating product operation rules; - in case of connecting the product to electric mains of voltage exceeding voltage value specified in the user's manual; - in case of step voltage that resulted in the product failure; - in case of the customer's performing unauthorised repair of the product; - in case of performing repair of the product by third persons unauthorized by the manufacturing company; - in case of warranty period (service life) expiry; - in case of the customer's violating transportation rules assuring prevention of damaging and/or destruction of the product; - in case of the customer's violating product storage rules; 7

EN - in case of performing unlawful actions by third persons with respect to the product; - in case of force majeure (fire, flood, earthquake, war, hostilities of any kind, blockade); - no seals, provided such seals are prescribed by the user's manual or other relevant substituting document; - in case of unavailable warranty card; - in case of unavailable payment document to confirm the purchase with indication of the sale date. The manufacturing company shall be responsible for defects arising through its fault prior to the moment of transferring the product to the ownership of the customer. The manufacturing company shall not be responsible for defects arising after transferring the product to the customer and caused by the customer's violating the rules of transportation, storage, assembly and operation of the product, or by actions of third persons, an accident or force majeure circumstances. The manufacturing company shall not be responsible for damage to health and property of the customer caused by the customer's violating the user's manual or other relevant substituting document; other use of the product by the customer other than its intended use, or by failure of the customer to comply with warnings and other information on the product specified in the user's manual or other relevant substituting document, or by the customer's violating the rules of transportation, storage, mounting, maintenance and operation of the product. 8

9 1 m 2 9

MOUNTING QF 3 4 5 6 10

7 8 11

min min max max 22 21 23 20 C 24 25 26 27 tc 28 29 30 C VK 100/125/150/200/250/315 X N QF N X N QF N L L L S L 9 VK 100/125/150/200/250/315 U / U1 / Un / U1n / P / R speed control knob QF temperature control knob ~ 11 speed control knob ~ 10 12 12

13 14 13

15 15 16 17 18 14

15 19 20 15

Acceptance certificate Approval mark Sold (Seller name and stamp) Manufacturing date 100 VK VKS 125 150 200 250 315 Q U U1 n R P Date of sale The fan is duly recognized as serviceable. www.ventilation-system.com V02-VK(EN)-08