HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

Similar documents
HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

STANDARD/quick. Sprinkler 42o. August 8, 2011

Quick response concealed horizontal sidewall sprinkler VK481

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

Standard Spray concealed horizontal sidewall sprinkler VK481

microfast and microfasthp quick conventional sprinklers

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

TECHNICAL DATA OBSOLETE

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

TECHNICAL DATA OBSOLETE

sprinkler vk538 (K11.2)

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

micromatic standard response stainless steel sprinklers

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

Microfast quick response Fusible element hsw sprinkler

standard response Fusible Link Upright sprinkler VK204 (K8.0)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 5

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

standard response fusible link sidewall sprinkler VK112 (K5.6)

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

quick response horizontal sidewall sprinkler vk360 (K8.0)

microfast quick response extended coverage hsw sprinkler vk606

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

TECHNICAL DATA. Page 1 of 6

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

microfast sr/qr extended coverage pendent sprinkler

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

freedom residential concealed pendent sprinkler VK488 (K3.0)

standard response/ quick response extended coverage

standard response dry horizontal sidewall sprinklers

freedom residential flush pendent sprinkler vk476 (K4.9)

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

microfast quick response Pendent sprinkler VK302 (K5.6)

freedom residential concealed pendent lead free sprinkler

standard response large orifice dry

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

standard/quick response extended coverage light and ordinary hazard elo sprinklers

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

December 14, 2015 Page 1 of 7 TECHNICAL DATA

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

micromatic Standard response Horizontal Sidewall sprinkler

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

standard response elo upright and pendent sprinklers (storage-density/area)

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

standard response elo upright sprinkler

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

freedom residential concealed pendent sprinkler vk474 (K5.8)

micromatic Standard response Horizontal Sidewall sprinkler

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

standard response dry horizontal sidewall sprinklers

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

freedom residential concealed pendent Sprinkler vk458 (K7.4)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

Transcription:

Sprinkler 53a 1. DESCRIPTION Viking Horizon Quick Response Flush Pendent Sprinklers are small, flush, solder link and lever spray sprinklers. Designed for use with concealed piping, the units are mounted flush to the ceiling with the fusible link exposed. The sprinklers are available with a Polished Chrome or White painted finish with four styles of ceilings rings (see Figure 1), which allow up to ¼ (6.3 mm) of adjustment. The standard 2-11/16 (68 mm) diameter ceiling rings are available in a thread-on style for stability, or in a push-on style for ease of installation. A 3 (76.2 mm) diameter push-on ceiling ring and a 3-1/4 (82.5 mm) diameter thread-on ceiling ring are also available. The two-piece design allows installation and testing of the sprinklers prior to ceiling installation. The ceiling ring can be removed and reinstalled, allowing removal of ceiling panels without shutting down the sprinkler system and removing the sprinkler. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: City of New York Board of Standards and Appeals, Calendar No. 219-76-SA LPC Approved: Ref. No. 096e/08 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2024 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria on page 53d for culus Listing requirements, and Refer to Approval Chart 2 and Design Criteria on page 53e for FM Approval requirements that must be followed. 3. Specifications: Available since 1988. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) Factory tested pneumatically to 95 psi (6.55 bar) Spring: U.S.A. Patent No. 4,570,720 Thread size: 1/2 (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric ) *culus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Overall Length: 2-9/16 (65 mm) Material Standards: Sprinkler Body: Brass UNS-C84400 Body Cap: Stainless Steel UNS-S30400 or UNS-S30500 Cover: Stainless Steel UNS-S43000 Deflector: Copper UNS-C19500 Deflector Pins: Stainless Steel UNS-S30300 Button: UNS-C23000 H55-H80 Compression Screw: Brass UNS-C36000 Element Assembly: Beryllium Nickel and Eutectic Solder Levers: Stainless Steel UNS-S31600 Lever Bar: Copper Alloy UNS-C72500 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Ceiling Ring: Cold Rolled Steel UNS-G10080 or Brass UNS-C26000 Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Form No. F_081888 Replaces page 53a-d, dated October 9, 2009. (Updated FM Approvals and split the Approval Charts to separate UL Listing requirements from FM Approval requirements.)

Sprinkler 53b Ordering Information: (Also refer to the current Viking price list.) Viking Horizon Quick Response Flush Pendent Sprinklers and Ceiling Rings must be ordered separately: Sprinklers: Base Part No. 06702B or 11487 Order the Horizon Quick Response Flush Pendent Sprinkler by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Polished Chrome = F or White Polyester = M-/W Temperature Suffix ( F/ C): 165 /74 = C For example, sprinkler VK402 with a Chrome finish and 165 F/74 C temperature rating = 06702BFC. Ceiling Rings: Base Part No. 07027 push-on style with a 2-11/16 (68 mm) diameter Base Part No. 07626 push-on style with a 3 (76,2 mm) diameter Base Part No. 06919B thread-on style with a 2-11/16 (68 mm) diameter Base Part No. 06905B thread-on style with a 3-1/4 (82,5 mm) diameter Specify the finish of the ceiling ring: Polished Chrome = F, Painted White = M-/W For example, ceiling ring 07027 with a Polished Chrome finish = 07027F. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches*: A. Heavy Duty Part Number 08336W/B (available since 1983), or B. Light Duty Part Number 10366W/B** (available since 1998) *Requires a ½ ratchet (not available from Viking). **Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: six (6) sprinklers (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION The concealed deflector is held inside the body of the sprinklers until the eutectic metal solder link is fused. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking flush style sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly.

Sprinkler 53c Sprinkler Temperature Classification TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Ordinary 165 F (74 C) 100 F (38 C) Sprinkler Finishes: Polished Chrome or White Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler body. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Figure 1: Sprinkler Installation and Correct Use of Wrenches

Sprinkler 53d Sprinkler Base Part No 1 SIN NPT Thread Size Approval Chart 1 (UL) Horizon Quick Response Flush Pendent Sprinklers Nominal K-Factor Maximum Water Working Pressure Overall Length Listings and Approvals 3 (Refer also to Design Criteria below.) Inch mm U.S. metric 2 Inches mm culus 4 NYC 5 LPCB 8 06702B VK402 1/2 15 5.6 80.6 175 psi (12 bar) 2-9/16 65 A1 A1 A1 A1 6 -- 11487 VK413 1/2 15 5.6 80.6 175 psi (12 bar) 2-9/16 65 -- -- A1 A2 7 A2 Sprinkler Temperature Rating A - 165 F (74 C) Approved Finishes 1 - Polished Chrome or White 2 - Polished Chrome Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed by Underwriter s Laboratories for use in the U.S. and Canada. 5 Accepted for use, City of New York Board of Standards and Appeals, Calendar No. 219-76-SA. 6 Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 7 Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2024. 8 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above) culus Listing Requirements: Horizon Quick Response Flush Pendent Sprinklers are culus Listed for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below: For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. LPCB and CE Approval: Horizon Quick Response Flush Pendent Sprinklers are LPCB approved and CE marked for installation in accordance with the latest edition of EN12845 and the LPC Rules for Automatic Sprinkler Installations including systems for Life Safety. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Sprinkler 53e Approval Chart 2 (FM) Horizon Quick Response Flush Pendent Sprinklers NPT Sprinkler Nominal K-Factor Maximum Overall Length SIN Thread Size FM Approvals Water Working 3 Base Part No 1 (Refer also to Design Criteria below.) Inch mm U.S. metric 2 Pressure Inches mm 06702B VK402 1/2 15 5.6 80.6 175 psi (12 bar) 2-9/16 65 A1 Sprinkler Temperature Rating A - 165 F (74 C) Approved Finishes 1 - Polished Chrome or White Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above) FM Approval Requirements: Horizon Flush Pendent Sprinkler VK402 is FM Approved as a quick response Non-Storage flush pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from culus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_081888 Replaces page 53a-d, dated October 9, 2009. (Updated FM Approvals and split the Approval Charts to separate UL Listing requirements from FM Approval requirements.)