MANUFACTURED BY. Gus Berthold Electric Company 1900 W. Carroll Avenue Chicago, Illinois 60612

Similar documents
ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Instruction Manual Model A

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Installation Instructions

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

Table of Contents. Protective Relays

Installation Instructions for W2H Series Signals

AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

SONAC 110 INSTALLATION & OPERATION MANUAL

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

PART GENERAL 1.01 SECTION INCLUDES

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

Electric Duct Heaters

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Installation Instructions

LMR Electric Fire Pump Controllers Features

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Transfer Switch Features

SERVICE PARTS LIST for

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

SECTION LOW VOLTAGE LIGHTING CONTROLS

Model 4001 Series Single Channel Controller

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

La Marche Manufacturing Company A36D. Battery Charger / Power Supply. Installation and Operation Manual

Fluid Cooler Fan and Pump control panel

Cedarbrook Sauna + Steam Family owned and operated since 1971

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

HD3D Forced-Air Heater

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

EATON DFDAP-M / FDAP-M Remote Alarm Panels

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

Power Supply Display Module PSDM. Installation and Operation Manual

FAN POWERED VAV TERMINALS

CAUTION & SYMBOL DEFINITIONS:

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

SECTION AUTOMATIC TRANSFER SWITCHES

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

LMR Electric Fire Pump Controllers Features

Construction Electrical

Be sure DC power is applied safely to terminals 3-4. Use caution during testing.

CX-29. Section 1 General Description. Section 2 Installation. Besam Switching Network & Bi-Directional Door Sequencer Installation Instructions

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

CONTENTS AUTOMATIC TRANSFER SWITCHES

SSV-DC user manual. Phason

Event Detection System (EDS)

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

631RF Amp Power Supply

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

CHAPTER 20 SERVICE EQUIPMENT

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Commercial and Light Industrial Fire Alarm Control Panel

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

SECTION AUTOMATIC TRANSFER SWITCHES

CP CP

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

Installation and Operation Manual Low Power (LP) DC Power System

Motogard. Over Temperature Protection System. Installation Instructions

M15051) INSTRUCTION MANUAL

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

MANUAL RESET ALARM RELEASE

KARMEL KING Instruction Manual Models: 2620 & 2621 (240 Volt) 2630 & 2631 (208 Volt) Part No Revised: February 2009

ULTRA-SAFE Explosion-proof Duct Heaters

SECTION DOMESTIC WATER HEATERS

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

INTRODUCTION / TABLE OF CONTENTS

FDF Foam Pump Controllers Features

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions

SECTION AUTOMATIC TRANSFER SWITCHES

Installation, Operation, and Troubleshooting Instructions

Air Conditioning Operation and Troubleshooting Matt Dunham

EBC 10 Fan Control USA CAN. Product Information. ... Chapter 1+2. Mechanical Installation. ... Chapter 3. Electrical Installation. ...

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

DAWN Electronics, Inc.

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Transcription:

Installation Manual S3031-48VDC Emergency Lighting Controller MANUFACTURED BY Gus Berthold Electric Company 1900 W. Carroll Avenue Chicago, Illinois 60612 Phone: 312-243-5767 Fax: 312-243-5811 E-mail: info@bertholdelectric.com Website: www.bertholdelectric.com

Installation Manual S3031-48VDC Emergency Lighting Controller 407571041 - S3031-V1 (120/208V, 3Ph, 3W) 407571017 - S3031-V2 (277/480V, 3Ph, 3W) 407571033 - S3031-V3 (120/240V, 1Ph, 2W) 407578764 - S3031-C (NEMA 1 Enclosure ) MANUFACTURED BY Gus Berthold Electric Company 1900 W. Carroll Avenue Chicago, Illinois 60612 Phone: 312-243-5767 Fax: 312-243-5811 E-mail: info@bertholdelectric.com Website: www.bertholdelectric.com

Table Of Contents S3031 48VDC Emergency Lighting Controller pages 1-2 S3031 Component List pages 3-4 S3031-V1 Installation Instructions pages 5-6 S3031-V1 Wiring Diagram page 7 S3031-V2 Installation Instructions pages 9-10 S3031-V2 Wiring Diagram page 11 S3031-V3 Installation Instructions pages 13-14 S3031-V3 Wiring Diagram page 15

S3031 48VDC Emergency Lighting Controller Description: The S3031 48V DC, 100A Emergency Lighting Controller is designed for new installations or as a direct replacement for controllers manufactured by the Palmer Electric Division, commonly known as "Palmer Relays". The S3031 is assembled on an insulating panel, with a fiberglass back barrier, ready to mount in the existing or a new enclosure. Enclosure available for new installations S3031-C (Enclosure). Connection terminals are in the same location as the existing terminals. Sensing available for all common voltages: S3031-V1 (120/208 Volt, 3 Phase, 3 Wire) S3031-V2 (277/480 Volt, 3 Phase, 3 Wire) S3031-V3 (120/240 Volt, 1 Phase, 2Wire) Application: Replaces your failing Palmer Relay type, 48V Emergency Lighting Controller without new cabling. All existing cables and wires will be reconnected in the same physical location. For new installations, the S3031 can be furnished with an enclosure measuring 20.5" W x 25.5" H x 7" D with a lift off cover. page 1

Electrical Specifications: Voltage Rating: 48 Volts DC Ampere Rating: 100 Amps Sensing Voltages: 120/208V, 3 Phase, 3W 277/480V, 3 Phase, 3W 120/240V, 1 Phase, 2W Ground Bus Features: Direct replacement for "Palmer Relay" S3031 is assembled on an insulating panel with fiberglass back barrier New terminals in the same location as the existing terminals Line Terminal Voltage Sensing Relay Contactor Test Switch Load Terminal TRANSFER TEST NORMAL TEST Mounting Holes Comcode Numbers: 407571041 - S3031-V1 (120/208V, 3Ph, 3W) 407571017 - S3031-V2 (277/480V, 3Ph, 3W) 407571033 - S3031-V3 (120/240V, 1Ph, 2W) 407578764 - S3031-C (NEMA 1 Enclosure) Voltage Sensing Terminal Block page 2

S3031 Component List Part No. Description Dwg. No. S3031-V1 S3031-V2 S3031-V3 S3031-P1 Contactor, Joslyn-Clark Cat. No. 7701-1000-63 1 1 1 S3031-P2 Panel S3031-3 1 1 1 S3031-P3 Barrier S3031-3 1 1 1 S3031-P4 Ground Bus S3031-4 1 1 1 S3031-P5 Line/Load Terminal S3031-4 2 2 2 S3031-P6 Spacer-Line/Load Terminal S3031-4 2 2 2 S3031-P7 Bus Link S3031-4 2 2 2 S3031-P8 Zee Bus S3031-4 2 2 2 S3031-P9 Test Switch - Honneywell INT1-3 (95F5209) 1 1 1 S3031-P9A Test Switch Nameplate S3031-4 1 1 1 S3031-P10 Test Switch Bracket S3031-4 1 1 1 S3031-P11A Voltage Relay, 208V - Time Mark B2644 1 S3031-P11B Voltage Relay, 480V - Time Mark C2644 1 S3031-P11C Voltage Relay, 120/240V, 1Ph - Time Mark 160B240 1 S3031-P11D Auxillary Relay "R" - P&B KUP11D55-48 1 S3031-P11E Mounting base for 11C and 11D S3031-4 1 S3031-P12 Diode D1 & D2-1N5404 1 1 2 S3031-P13 Terminal Block - Buchannan # 1 1 1 S3031-X1 S3031-V1 and S3031-V2 Schematic Diagram S3031-X1 1 1 S3031-X2 S3031-V1 and S3031-V2 Instalation Instructions S3031-X2 1 1 S3031-X4 S3031-V3 Schematic Diagram S3031-X4 1 S3031-X5 S3031-V3 Instalation Instructions S3031-X5 1 3/8-16 HHMS (GR5) w/sae FW and split LW 1/4" SAE FW 10 4 10 4 10 4 Quantity Required page 3

S3031-P2 S3031-P3 (behind P2) S3031-P4 S3031-P11A (S3031-V1) S3031-P11B (S3031-V2) S3031-P11C (S3031-V3) S3031-P11E S3031-P1 S3031-P6 (behind P5) S3031-P5 S3031-P8 S3031-P7 S3031-P7 S3031-P8 NORMAL TRANSFER TEST TEST S3031-P11D S3031-P10 S3031-P9A S3031-P9 S3031-P5 S3031-P6 (behind P5) S3031-P13 S-3031-V1, -V2, & -V3 Component Location page 4

S3031-V1 Installation Instructions Warning: Disconnect all power, both DC and AC, before working on equipment. A) Existing Installation. 1. 2. 3. 4. 5. 6. 7. 8. Disconnect DC and AC power. Remove the existing panel from the enclosure. Mount the new panel using the existing mounting screws and the flat washers provided. The fiberglass back barrier must be between the panel and the back of the enclosure. Reconnect the DC power and AC sensing leads and re-energize the AC sensing power. With the test switch in the normal position turn the two potentiometers on the face of the Voltage Sensing relay (VR) fully counter clockwise. The green "Normal" LED should be lit and the red "Tripped" LED should be out. Relay VR is phase sequence sensative. If the green LED is not lit, verify that normal voltage is present at the VR terminals A, B and C. If normal voltage is present, de-energize the voltage sensing power and interchange any two phasr leads at the voltage sensing terminal block and re-energize the sensing circuit. With the green LED lit, slowly turn the "failure level" potentiometer clockwise untill the green LED goes out and the red goes on. Turn the potentiometer counter clockwise until the green LED goes on and then slightly past this point. THis sets the voltage failure level. Operate the test switch tothe test position. The green LED should go out. Return the test switch to the normal position. The green LED should go on. Re-energize the DC power. Turn the "seconds" potentiometer on the VR relay slightly clockwise to add time delay to prevent nuscience operation of the contactor. Operate the test switch and verify that the contactor operates. page 5

12 1/2" 10 1/2" Ground Bus Line Terminal 17 1/2" 15 1/2" Voltage Sensing Relay Contactor Test Switch TRANSFER TEST Load Terminal NORMAL TEST Voltage Sensing Terminal Block S3031-V1 Component Location page 6

S3031-V1 Wiring Diagram From 48 VDC (+) (-) Plant Incoming DC power must be connected to line terminal. Ground Bus A B C G L TD VOLTS Line Terminal VR (VOLTAGE RELAY) D1 C C Load Terminal J2 X C B A1 A TEST SWITCH A B C N Voltage sensing terminals Protect taps at point of origin with 3 Ampere current limiting fuse. Neutral connection is not required for new installations. The terminal is provided only as a convience for existing instalations. DC emergency lights, 100 Ampere maximum. Note: The voltage sensing relay (VR) is phase sequence sensitive- see installation instructions. page 7 S3031-V1 (120/208V, 3Ph, 3W)

S3031-V2 Installation Instructions Warning: Disconnect all power, both DC and AC, before working on equipment. A) 1. 2. 3. 4. 5. 6. 7. 8. Existing Installation. Disconnect DC and AC power. Remove the existing panel from the enclosure. Mount the new panel using the existing mounting screws and the flat washers provided. The fiberglass back barrier must be between the panel and the back of the enclosure. Reconnect the DC power and AC sensing leads and re-energize the AC sensing power. With the test switch in the normal position turn the two potentiometers on the face of the Voltage Sensing relay (VR) fully counter clockwise. The green "Normal" LED should be lit and the red "Tripped" LED should be out. Relay VR is phase sequence sensative. If the green LED is not lit, verify that normal voltage is present at the VR terminals A, B and C. If normal voltage is present, de-energize the voltage sensing power and interchange any two phasr leads at the voltage sensing terminal block and re-energize the sensing circuit. With the green LED lit, slowly turn the "failure level" potentiometer clockwise untill the green LED goes out and the red goes on. Turn the potentiometer counter clockwise until the green LED goes on and then slightly past this point. THis sets the voltage failure level. Operate the test switch tothe test position. The green LED should go out. Return the test switch to the normal position. The green LED should go on. Re-energize the DC power. Turn the "seconds" potentiometer on the VR relay slightly clockwise to add time delay to prevent nuscience operation of the contactor. Operate the test switch and verify that the contactor operates. page 9

12 1/2" 10 1/2" Ground Bus Line Terminal 17 1/2" 15 1/2" Voltage Sensing Relay Contactor Test Switch TRANSFER TEST Load Terminal NORMAL TEST Voltage Sensing Terminal Block S3031-V2 Component Location page 10

S3031-V2 Wiring Diagram From 48 VDC (+) (-) Plant Incoming DC power must be connected to line terminal. Ground Bus A B C G L TD VOLTS Line Terminal VR (VOLTAGE RELAY) D1 C C Load Terminal J2 X C B A1 A TEST SWITCH A B C N Voltage sensing terminals Protect taps at point of origin with 3 Ampere current limiting fuse. Neutral connection is not required for new installations. The terminal is provided only as a convience for existing instalations. DC emergency lights, 100 Ampere maximum. Note: The voltage sensing relay (VR) is phase sequence sensitive- see installation instructions. page 11 S3031-V2 (277/480V, 3Ph, 3W)

S3031-V3 Installation Instructions Warning: Disconnect all power, both DC and AC, before working on equipment. A) 1. 2. 3. 4. 5. 6. 7. 8. Existing Installation. Disconnect DC and AC power. Remove the existing panel from the enclosure. Mount the new panel using the existing mounting screws and the flat washers provided. The fiberglass back barrier must be between the panel and the back of the enclosure. Reconnect the DC power and AC sensing leads and re-energize the AC sensing power. With the test switch in the normal position turn the potentiometer on the face of the Voltage Sensing relay (VR) fully counter clockwise. The red "Tripped" LED should be out. Slowly turn the "volts" potentiometer clockwise untill the red LED goes on. Turn the potentiometer counter clockwise until the red LED goes out and then slightly past this point. This sets the voltage failure level. Operate the test switch tothe test position. The red LED should go on. Return the test switch to the normal position. The red LED should go out. Re-energize the DC power. Operate the test switch to the test position and verify that the contactor operates. page 13

12 1/2" 10 1/2" Ground Bus Voltage Sensing Relay Line Terminal 17 1/2" 15 1/2" Relay R Contactor Test Switch TRANSFER TEST Load Terminal NORMAL TEST Voltage Sensing Terminal Block S-3031-V3 Component Location page 14

S3031-V3 Wiring Diagram From 48 VDC (+) (-) Plant Incoming DC power must be connected to line terminal. Ground Bus G + VOLTS NO C - VR (VOLTAGE RELAY) NC G 4 7 L L Line Terminal 1 6 J2 J1 D1 C C 9 3 Load Terminal A R B D2 X B A1 TEST SWITCH A A B N Voltage sensing terminals Protect taps at point of origin with 3 Ampere current limiting fuse. Neutral connection is not required for new installations. The terminal is provided only as a convience for existing instalations. DC emergency lights, 100 Ampere maximum. 240 Volt 120 120 page 15 S3031-V3 (120/240V, 1Ph, 2W)

MANUFACTURED BY Gus Berthold Electric Company 1900 W. Carroll Avenue Chicago, Illinois 60612 Phone: 312-243-5767 Fax: 312-243-5811 E-mail: info@bertholdelectric.com Website: www.bertholdelectric.com

MANUFACTURED BY Gus Berthold Electric Company 1900 W. Carroll Avenue Chicago, Illinois 60612 Phone: 312-243-5767 Fax: 312-243-5811 E-mail: info@bertholdelectric.com Website: www.bertholdelectric.com