Incident Summary (Reference # II )

Similar documents
Incident Summary #II (#8165) (FINAL)

Incident Summary (II )

Incident Summary (Reference # )

Incident Summary (Reference # )

Incident Summary (Reference # ) (DRAFT)

L O S S C O N T R O L

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL

Flush Face Fireplace Planning Guide

RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS

USER'S INFORMATION MANUAL

CAUTION FOR YOUR SAFETY

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

USER'S INFORMATION MANUAL

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

DR J H BURGOYNE AND PARTNERS LLP FORENSIC SERVICES

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Knowledge Objectives (2 of 2) Fuel Gas Systems. Skills Objectives. Introduction. Fuel Gas Systems (1 of 6) 12/20/2013

USER S INFORMATION MANUAL

Packaged Gas/Electric

To dismantle and reassemble domestic Gas Geyser i.e. Gas Water Heater

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

EDVRSPV47 EDVRSPV58. Warning: What to do if you smell gas

Explosion at Battery Site Date of Incident: Type of Incident: Fatal

REPLACEMENT PARTS LIST WARNING

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

OIL FIRED WARM AIR FURNACE. Homeowner Instructions

SLIMLINE DIRECT VENT GAS FIREPLACES

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Dexter Industrial On Premise Dryer. Troubleshooting, Fault Codes, And Schematics. Starting serial number Part # /13

USER'S INFORMATION MANUAL

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

Instructor Guide. Title: Tactical Approach to Chimney Fires. Time Required: 2 hours. Materials: PowerPoint presentation AV equipment

RM2604 & RM2804 Gas Controls

Heating with Wood. Part 2

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

The Baked Food Company

SUBMITTAL SCHEDULE & DATA

HOME ENERGY SAVINGS GUIDE

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Heating system service plans that provide total peace of mind.

DT-2 & DR-2 MERIT SERIES

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

USER S INFORMATION MANUAL (2,4)SG13B

SYSTEM CONTROL KIT. Model: CK-62. Designed for use on SWG Series Power Vent Hoods for controlling oil fired heating appliances with 120 VAC controls.

Dexter Commercial Vended Stack Washer Dryer. Dryer Troubleshooting, Fault Codes, And Schematics. Starting serial number (12/13)

Operation & Maintenance Manual

research highlight Canadian Housing Fire Statistics Findings

Luxury. Tahoe Traditional Clean-Face LUXURY DIRECT-VENT FIREPLACE

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Installation and Maintenance Manual Please retain this manual for future reference.

DT/DTH/DR/DRH MERIT SERIES

Drying Tumblers Pound Capacity

P4000 Construction Heater

Railroad Commission of Texas Pipeline Evaluation System Incident Updates Inspection Package ID =

Chapter One Commercial Kitchen Fires

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

Enviro. Designed to heat. Built to last. Designed to heat. Built to Last. For over 25 years, unsurpassed quality and craftsmanship


FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE

USER S INFORMATION MANUAL

6000 Series. Direct Vent Gas Fireplaces

Columbia Boiler Company

3330 N Clayton. C - Side Date: 11/18/2017 Time: 21:48 Incident Number: Address: 3330 N Clayton

CSD-1 COMMERCIAL BOILER CONTROLS

Rushmore Clean-Face Direct-Vent Fireplace. Rushmore WITH TRUFLAME TECHNOLOGY

Fire and Extinguishing Tests on Computer Equipment

96.7 THE NEW GENERATION OF OIL-FIRED WARM AIR FURNACES + COMFORTABLE + PERFORMANCE + ECONOMICAL OPERATION + EASE OF MAINTENANCE + VERSATILE AFUE UP TO

Luxury. Tahoe Traditional Clean-Face LUXURY DIRECT-VENT FIREPLACE

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

PTO50 Outdoor Decorative Fireplace

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

USER MANUAL SOM SERIES MUL-T-POISE WARM AIR OIL FIRED FURNACE

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Computing Services Center

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

Intermittent Pilot Ignition (IPI) and Direct Spark Ignition (DSI) Applications with Flame Current Probes

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

USER S INFORMATION MANUAL

Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination

SLIM-LINE BUILT-IN FIREPLACES

PVE SERIES POWER VENTER SYSTEM MANUAL

The Stanford 55L. Direct Vent Linear. Model Number Description MSRP

DC50X2 Models 50 Pound Stacked Commercial Dryer. Troubleshooting,Fault Codes, and Schematics. Starting serial number Part # /13

The six tests conducted included three smoldering and three fast flaming type tests.

ENERGY & WATER EFFICIENCY: HOME ASSESSMENTS. Jim Riggins Monument, CO

BCTC CARPET TECHNICAL CENTRE

Bosch 80% AFUE Gas Furnace BGS80 Model

An Oven Explosion Lessons Learned on PSM Concepts (or PSM: It s not just for breakfast anymore )

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES

Comment on Hawker Stall Fires

Transcription:

Incident Summary (Reference # II-694077-2018) Incident Date May 26 2018. Location Regulated industry sector Langley Natural gas system SUPPORTING INFORMATION Impact Injury Damage Qty injuries 0 Injury description Injury rating Damage description Incident rating Damage rating Incident overview N\A N\A A natural gas explosion occurred at a residence inside a direct vented gas fireplace combustion chamber and venting system. The natural gas explosion damaged the venting beyond repair and scattered metal debris onto two sides of the residence outdoors Moderate Moderate A natural gas explosion occurred at a residence inside a direct vented gas fireplace combustion chamber and venting system. This explosion was contained to the gas fireplace combustion chamber and venting system. The gas explosion destroyed the venting and compromised the gas fireplace, the gas fireplace and venting must be replaced. INVESTIGATION CONCLUSIONS Site, system and components Failure scenario(s) During normal operation of this gas fireplace the thermostat is set to automatically cycle the gas fireplace on and off to maintain the residence at the set room temperature. When the thermostat falls below the set temperature and calls for heat the gas fireplace control board initiates the burner to ignite by first lighting the ignition pilot and then the burner. When the thermostat is satisfied that the room temperature has risen to the desired temperature it turns off the gas fireplace The gas safety valve opens when there is a call for heat and closes when the thermostat is satisfied and when the gas safety valve was too close it stuck open allowing natural gas to accumulate in the fireplace combustion chamber and venting system During normal operation of this gas fireplace the thermostat was set to automatically cycle the gas fireplace on and off to maintain the residence at the set room temperature. After being turned on in the morning and heating up the residence the gas fireplace cycle off and on again at approximately 1:00pm and an explosion occurred caused by a buildup off natural gas in the gas fireplaces combustion chamber and venting. This was caused because the gas safety valve failed to close completely allowing natural gas to pass through the safety valve into the fireplace combustion chamber and be ignited when the thermostat called for heat.

Incident Summary (Reference # II-694077-2018) - Gas fireplace explosion, May 26-2018 1pm - I met with homeowner and he confirmed that they were using the fireplace to heat the home - After being turned on in the morning and heating up the residence the gas fireplace cycle off and on again at approximately 1:00pm and an explosion occurred Facts and evidence - I talked to homeowner s fire investigator and he confirmed that the fireplace was secured by him - It was determined by an onsite pressure test by gas contactor s gas fitter supplied by the homeowners insurance company that the gas safety valve was stuck partially open and this caused the buildup of natural gas that exploded in the gas fireplace and venting Causes and contributing factors The gas safety valve failed to operate correctly(did not close completely) and was most likely the cause of this explosion

Figure 1 - Front view of fireplace with drywall removed

Figure 2 - View of gas fireplace venting above fireplace 10-15 away

Figure 3 View of fireplace venting above fireplace extending through 2nd floor to roof termination

This is a picture of the gas safety valve that failed