EPERTS IN HUMIITY MNGEMENT OTES.OM
IEL FOR USE IN 3 Pharmaceutical production facilities Food industry processing facilities old stores/freezer facilities Waterworks General humidity management in all kinds of indoor spaces EHUMIIFITION THE WY YOU WNT IT (model shown with PL) WITH HET REOVERY WITH IR-OOLE ONENSTION VNTGES Sleek, ultra-modern appearance ccurate, software-driven monitoring and control Exceptional build quality Exceptionally low energy consumption etter monitoring of service intervals Standardised heating and cooling modules Stainless steel cabinet Easy to clean and keep clean Low-noise operation omplies with ErP irective 2015 ENEFITS an be placed even in highly visible public places More cost-effective management of air humidity Long service life and low maintenance /repair costs Low operating costs Savings on manpower and maintenance Easy to maintain high hygiene levels Exact control of all aspects of ingoing and outgoing air flows Heat recovery reduces environmental footprint Easy to install OPTIONL EQUIPMENT Post-heating module Pre-cooling and post-cooling modules Heat recovery module ir-cooled condensation module dditional temperature and humidity sensors Extra insulation NILLRY EQUIPMENT ifferent filter configurations, as required rackets for wall mounting rackets for floor mounting otes ll-round 35 is an innovative range of elegant, versatile dehumidifiers, with moisture removal capacities of 3 6 kg per hour Modular confgurations The sleek stainless steel cabinet, featuring the best of modern industrial design, makes otes ll-round dehumidifiers ideal for installation even in highly visible public locations. Standardised, modular configurations are available so you can easily integrate any heating units, cooling systems, heat recovery, fans, filters, sensors, control set-ups, etc. that you need for your particular operating set-up. otes ll-round units also feature built-in electronic monitoring and control capabilities that make it easy to customise the dehumidifier to your exact operating requirements and priorities. Where they re used otes ll-round dehumidifiers are designed for three main types of use. units are configured with particular focus on high values (the driest air possible) in industrial processes where it is essential to keep the levels of moisture in the air under stringent control. units, on the other hand, are specially configured for effective humidity management in enclosed spaces, and where the main focus is on keeping energy consumption to the minimum. specialised 35 design is also available, specially configured and designed for use in a wide range of cold stores and freezer facilities. For further details, please consult the data sheet for 35. Want to know more? ontact otes experts at T +45 5819 6322 or sales@cotes.com
YOUR EISION OUT ONTROL ONFIGURTIONS 5 comprehensive range of software-based monitoring and control capabilities are available. You simply decide which configuration you need to have and order accordingly. MONITORING N ONTROL SETUPS HOUR OUNTER TO MONITOR RUNNING TIME OVERHETING LRM ETERNL HUMIITY SENSOR (R/H) OPTIONL SERVIE INITOR TO MONITOR MINTENNE REQUIREMENTS TLOGGING FOR TRKING ONITIONS SERVIE LRM MONITORING 3.5-INH TOUH PNEL ONTROL OF REGENERTION IR FN MESUREMENT N ONTROL FTER EW POINT TIMER, Y/NIGHT TIMER N YLE TIMER NETWORK FOR ONNETIVITY (optional) MONITORING N ONTROL VI SMRTPHONE PP (optional) MONITORING N ONTROL Y OTES SERVIE ENTRE (optional) PITY ONTROL / MOULTING HET ONTROL ETR ETERNL HUMIITY SENSOR (R/H and dew point) Up to two external humidity sensors can be connected (single sensor included) MONITORING N ONTROL OF IR FLOWS QUIET PROGRM USTOM PROGRM ENERGY SVING PROGRM ENERGY+ SVING PROGRM (for process applications) ONTINUOUS MESUREMENT OF MOISTURE REMOVL PITY LRM SPEIFI HUMIITY (g/kg) PROGRM SI FILTER N ROTOR SERVIE LRM MOULR EQUIPMENT ONFIGURTIONS You simply decide which equipment combinations you want for the exact specifications you need. ontact otes experts for details or alternative options. PRE- E FOR ENERGY OPTIMISTION IR-OOLE ONENSTION HETING HET REOVERY PRE- IR-OOLE ONENSTION HETING FOR EEP RYING HET REOVERY hoice of control configurations Four different levels of electronic control functionalities are available for otes ll-round 35 units, so you can match the dehumidifier to your particular practical requirements and operating priorities. n easy-to-read 3 ½-inch touch panel is fitted as standard to give you easy access to your chosen level of performance data, operating alarms and service interval monitoring. You can choose to activate completely standardised settings where you just turn the unit on and forget about it or to opt for varying degrees of control over air flow specifications. You decide on the level of control access you need or want, via smartphones, web-based remote control, etc. Heat recovery You can order your ll-round 35 dehumidifier with a highly efficient aluminium cross-flow air-to-air heat exchanger to recover heat from the regeneration air leaving the unit. This thermal energy can then be reused to preheat the incoming regeneration air. The heat exchanger is placed in a matching stainless steel case with inlets and outlets for the incoming and outgoing regeneration air. These energy-saving heat recovery units can save as much as 20% on your energy bills, resulting in payback in as little as approx. 24 months. otes heat recovery modules are available factory-fitted as standard, or can be retrofitted to existing ll-round 35 dehumidifiers. Post-heating otes ll-round dehumidifiers can be fitted with post-heating units after the adsorption rotor, as optional equipment, in order to ensure 0% control of both relative humidity and temperature. Pre-cooling and post-cooling otes ll-round 35 dehumidifiers can be fitted with a special cooling unit to reduce and/or control the temperature /humidity of the dry air entering and leaving the dehumidifier. cooling unit fitted before the adsorption rotor is particularly beneficial if the incoming process air is very warm and humid. In such cases, some of the water in the air condenses, thus increasing the efficiency of the adsorption rotor. cooling unit fitted before the adsorption rotor is also available if the outgoing process air has to be especially dry. Water condensation ll-round dehumidifiers can be fitted with an air-cooled condensation unit in order to condense water from the regeneration air leaving the dehumidifier. This is a big benefit when a regeneration air outlet cannot be fitted.
7 TEHNIL T HOW IT WORKS W PROESS IR OUT REGENERTION IR IN 1 5 PROESS IR FLOW 1 6 REGENERTION IR FLOW H PROESS IR OUTLET PROESS IR IN REGENERTION IR OUT SUTION FN MINTINS FLOW OF PROESS IR 3.3 3.8 PROESS IR IS RIE Y THE ROTOR 5.6 3.2 FILTRTION RY IR NOMINL m3/hour 750 405 617 REGENERTION IR NOMINL m3/hour 8 202 233 202 VOLTGE/PHSES * V/Ph REGENERTION IR HETER kw 5.7 6.9 8.0 6.9 ONNETE LO kw 5.4 6.5 7.7 8.8 7.7 ETERNL FUSES ET. PRESSURE PROESS IR Pa 2 2 2 2 2 2 2 ET. PRESSURE REGENERTION IR Pa 250 PITY T 20, 60%RH kg/hour 3.3 3.8 5.6 3.2 SOUN LEVEL d() * PROESS IR INLET 1 REGENERTION IR INLET 2 FILTRTION 3 REGENERTION IR IS HETE 4 THE ROTOR IS RIE 5 SUTION FN MINTINS REGENERTION IR FLOW 6 REGENERTION IR OUTLET 4 3 TEHNIL T (sound pressure) 5 2 1 Other power connections available by request IMENSIONS N WEIGHT HORIZONTL ROTOR MIMUM FLEIILITY EEPTIONL UIL QULITY In otes ll-round units, the silica gel- otes ll-round dehumidifiers provide Like all otes dehumidifiers, ll-round coated rotor is mounted horizontally. This users with an exceptional degree units are built of robust, high-quality means all process air enters and leaves of control over airflow humidity and components and materials that ensure on the same side of the casing, while temperature specifications, via factory- maximum reliability, long service life and regeneration air enters and leaves on the installed control settings. rapid return on investment. opposite side. Standardised, modular configurations W WITH EPTH 2 2 2 2 2 2 2 H HEIGHT 90 90 90 90 90 90 90 PROESS IR INLET PROESS IR OUTLET ny additional heating and cooling units, are also available for easy integration & PROESS IR UT (with ILU adapter) as well as heat recovery units and other of a range of heating units, cooling REGENERTION IR INLET ancillary equipment, can be mounted in systems, fans, filters, sensors, control an additional module on the side, retaining set-ups, etc. REGENERTION IR OUTLET & REG. IR UT 2 1 1 1 1 1 1 WEIGHT (with ILU adapter) kg the sleek appearance of the stainless steel exterior.
LOSE TO YOU We have a worldwide network of otes experts ready to provide you with solutions to virtually any humidity management requirement. YOUR LOL OTES REPRESENTTIVE TLK TO US OUT WHT S POSSILE OTES /S ENMRK +45 5819 6322 SLES@OTES.OM OTES.OM