Sanosil disinfectant for air washers / air humidifiers

Similar documents
Sanosil disinfectants Use in CIP procedures

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Sanosil S010 Fungicide

Indoor Air Quality Test Report

"A Brief Guide to Mold, Moisture, and Your Home"

HYGIENE CRITERIA. Planning Guidelines for Humidification. Humidification and evaporative cooling

Indoor Environmental Quality Residential

INTELLIGENT HUMIDIFICATION. Two adiabatic humidification methods intelligently combined Condair DL. Humidification and evaporative cooling

AIR PURIFIER OZONE GENERATOR

Perfect Air Purifiers

Living. Healthy. Healthy Home Solutions. Turn to the Experts. Willis Carrier invented air conditioning in

Hantavirus Procedures

Indoor Mold and Health A Fungus among Us

A Brief Guide to Mold, Moisture, And Your Home

Double Intelligence Two adiabatic humidification methods intelligently combined. Humidification and Evaporative Cooling. humidity.

How The Air Oasis Air Purifiers Work The Air Oasis Mini, 1000, 3000, 3000 Xtreme, 5000 Commercial and Air Oasis Induct air purifiers utilize a

High Efficiency Air Cleaners

healthy comfort Indoor Air Quality Solutions

Home air-improvement options to suit your needs

MOLD AIR VENTILATION & DECONTAMINATION DUCK CLEANING HVAC SYSTEM & FOR REMEDIATION

LOVE YOUR HOME. These Energy-Saving & Water Solutions Products Can Help Make Your Home More Comfortable and Healthy.

Humidification Guide. Enjoy a healthy winter with the optimal indoor climate

My air. My life. Healthy air to breathe is a major factor in our health.

Advantages of the Sanosil Q-Jet devices

Mold Remediation. Anytime - Anyday Service. Free Inspections and Estimates Direct Insurance Company Billing Guaranteed Workmanship.

Powr-Zone Ozone Generator

Choosing an Air Cleaner

Healthy air in your vehicle:

Revision date: 22/4/2016 Date of print: 11/5/2016 Version: 1 Language: en-ca,us Page: 1 of 8

PCO/UV N-Duct Model. Owner s Guide

MULTI-TECH II INSTRUCTION MANUAL. Model XJ-3000D

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall

CLEANING AND SANITIZING

IONIZATION WHITE PAPER

healthy comfort Indoor Air Quality Solutions

Perfect Air Purifiers

2019 AIR PURIFIER CATALOG

Cleans and sanitizes CPAP mask and accessories. Lumin USER MANUAL.

REFERENCE GUIDE TO MAJOR INDOOR AIR POLLUTANTS IN THE HOME

Air Purity Solutions Whole-Home Air Purifiers

What Are Biological Pollutants?

energy recovery ventilation (erv)

Odour Control - Water Purification Air Sterilisation MAINTENANCE INSTALLATION INFORMATION.

Next Generation GENANO Technology

Integrated Ozone technology based solution For Hospital

MOLD, MOISTURE, YOUR HOME

7000/AP. Ozone Generator Air Purifier / Sterilizer. User Guide

at the touch of a button.

CLEANING THE AIR CONDITIONING SYSTEM Innovation

HEALTH. Particles. Chemicals

CLEAN AIR AND THE RECOUPAERATOR

PureAir Air Purification System PCO-12C/20C

Section 2. Product overview & label familiarisation

Biological Pollutants in Your Home

Reducing Allergens and Improving Your Overall Indoor Air Quality

RCD , D 577, 417 US

PROTECTING YOUR HEALTH SWINE FLU BOB & LEYLA S TIPS FOR HOMEOWNERS. Planning to sell or buy a house, contact:

Material Safety Data Sheet

Biological Drain Maintenance System

Ultraviolet Water Sterilizer Installation and Maintenance Manual

Spray Painting and Coating

For Air as Pure as the Ice Age

Air Quality in the Home

CHILDCARE SETTINGS. Childcare Settings

PHOTOCATALYTIC AIR CLEANER

HAZARDOUS MATERIALS (HAZMAT)

2015 Myco Industries, Inc Fax:

Dianne Harrison, Supervisor QA Lab

Perfect Solutions for Cleaner, Fresher Indoor Air

Comfort, Energy & Health Solutions

Legionella Policy and Procedure

PA / PA-PRO PORTABLE AIR PURIFIER Instruction Manual

Custom modular design to fit any application

Perfect Air Purifier. Indoor Comfort You Can Rely On. Indoor Air Quality Option Checklist q q q q q. Prior to Your Purchase

HEALTH. Particles. Chemicals

TAW H1 D. Instruction manual. /Model. Electric air washer.

Making Your Home Asthma Friendly

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

GF-3000 Ground Fog Machine. user manual

Serenade Opti CONTENTS

SANITARY PRACTICES POLICIES AND PROCEDURES

Biological pollutants in the home

IAQ & Moisture. Outline of Presentation. Fungi & Buildings IAQ. Fungi.

Got Mold? Frequently Asked Questions About Mold

PATENTED APG OZONE CELLS DESTROYS HARMFUL CONTAMINANTS REDUCE CHEMICAL DEMAND

Mold & Mildew Cleaning Up Your Flood-Damaged Home FEMA 606/July 2007

Air Purifier. Healthier Air, Healthier Life! Brings nature s best into your home

Breathe Easy with Sharp Plasmacluster Air Purifiers

What are Molds? ABOUT MOLD. California Department of Health Services. Indoor Air Quality Info Sheet. Mold in My Home: What Do I Do?

TAW H1 D. Instruction manual. /Model. Electric air washer (purifier) ( )

EVAPORATIVE COOL MIST HUMIDIFIER Instruction Manual

HEPA Air Purifier with Ion Flow Technology

SAFETY TECH. RRL Pendulum Test >36 (wet test) EN Class DS Bacterial resistance

AIR PURIFICATION SYSTEMS EXPERIENCE THE EVOLUTION OF CLEAN AIR

MarMax. Pets Home & Garden Horse. Made. in Austria

U S E R G U I D E. Home Respiratory Equipment Cleaning Guide. Health Information

HATCHERY. ROSS TECH Hatchery Maintenance. August 2011

For Air as Pure as the Ice Age

Disinfecting And Sanitizing Animal Facilities

Transcription:

Sanosil disinfectant for air washers / air humidifiers Sanosil Norge AS, Brannfjellveien 86 A, 1181 Oslo Tlf.: +47-908 52 546 E-post: post@sanosil.no sanosil.no DES P 27/en V2.0 sanosil.no SANOSIL

Be moderate, exercise, breath clean air and cure your illness by fasting instead of taking medicine if you want to be strong, healthy and young. Hippocrates 2/8

Air washers or air humidifiers are widely used in many workshops in the paper, printing and textile industries, among others. They are used either to ensure a consistent level of relative humidity in the rooms a requirement of some manufacturing processes or to reduce the amount of dust in the air in production halls. Air-conditioning systems that are rarely or insufficiently cleaned may cause acute respiratory diseases and, under circumstances, permanent health damage because of the explosive spreading of pathogenic microorganisms into a room. Since 1960, symptoms of diseases have been described that occurred in sick buildings. The appearance of diseases associated with the sick building syndrome is steadily increasing, and their common symptoms include headache, nausea, respiratory infections, dizziness, irritation of the conjunctiva as well as fatigue. How do air humidifiers or air washers contaminated by microbes harm your health? Water in air-humidification or air-washing systems may get colonized by a wide variety of microorganisms (bacteria, fungi, amoebae) that originate in the compartment or come from external air. For microorganisms, the conditions in such equipment are optimum with respect to temperature, humidity and nutrients (e.g. paper dust in printing facilities). Therefore, the Bacteria in biofilm microorganisms can multiply very quickly (mainly in standing water) and contaminate further parts of the system within a short time. By mechanical vaporization of the contaminated water, an aerosol is formed that contains a large quantity of pathogens, which, in this form, gain access to the lungs. Following this process, the aerosol spreads out very quickly into all rooms. The microorganisms themselves or their bacterial toxins (endotoxins) set free during the decomposition of gramnegative bacteria can cause various diseases through inhalation. Here are some examples: Humidifier fever Main symptoms of humidifier fever include a high temperature, shivering, irritation in the throat, dyspnoea but also very often common complaints such as a headache, fatigue and muscle pain. Typically, these complaints occur at the beginning of the week (Monday fever), 4 8 hours after starting to work. Outside the contaminated rooms, an improvement can be experienced within 12 24 hours. Long-term effects of a single case of humidifier fever develop only rarely. Humidifier lung (exogenic allergic alveolitis), This grave illness can be described as an allergic reaction in the area of the pulmonary alveoli to microbial antigens (mainly aspergillis, thermophilic actinomycetin, micropolyspora faeni, or pullularia). It manifests itself partly in the same way as humidifier fever; distinctive symptoms are shortness of breath, coughing, depression and sputum. Medical diagnosis can show a restriction of the lung functions and an increasing number of white blood cells as well as opacity over the lung in a thorax X-ray. Because of the slow course of the illness, it cannot be easily recognized at first. A complete recovery, i.e. normalization of lung functions, cannot be expected even after medical treatment or cessation from exposure to contaminated air. Alternatively, such allergic reactions manifest themselves as asthmatic attacks. Pneumonia Pulmonary lobe on the right side Legionella infection The primary route of Legionella infection in humans is inhalation of aerosolized bacteria. Therefore, showers, faucets, taps, evaporative condensers, air conditioners, whirlpools, and other aerosolizing devices are of paramount concern. Once in the lung, the Legionella are attacked by macrophages (the body s own leukocyte protection cells). However, protecting themselves with a mucous film, the Legionella avoid being digested by the macrophages and even reproduce within them. Reproduction continues until the macrophages burst, releasing hundreds of new Legionella bacteria. This leads to a heavy, maybe deathly infection 3/8

Types of air humidifiers: Principles of operation (Source SUVA Pro) Evaporators A rotating wheel or a mat is constantly humidified in a water bath, and air passing through the wheel or mat is humidified. Microorganisms can develop on the surfaces and in the water, but the aerosol formed is barely contaminated. This is why only very few microorganisms* can get into the air. However, a displeasing odor can result. * (Exception: In case of stationary evaporator mats, as shown in the picture, mold fungi very often develop and the air can be contaminated by allergenic mold spores.) Evaporator (small risk) Vaporizers Water is heated by means of a heating coil and then enters the room in the form of water vapor. The high temperature of the heated water inhibits the growth of microorganisms; however, the energy consumption needed for evaporation and decalcification of the water on a continuous basis is high. A further disadvantage of this system is that mold can develop on all surfaces and steam condenses on it. Vaporizer (very small risk) Atomizer (high degree of risk) Atomizers A rotor generates water droplets that are atomized into room air by making use of the available waste heat. A part of the atomized water combines with dust and dirt particles and falls back into the storage tank. Optimum conditions for the survival of microorganisms exist there, so they can possibly multiply explosively. If this contaminated water is atomized again, a large quantity of the microorganisms is blown into the air. This type of equipment is used preferably in combination with other ventilation systems in order to rehumidify the air that was previously cooled (and thereby had become relatively dry) to a comfortable water content. The memorable/infamous Legionella infection (with over 20 victims) at the American Legion Convention in Philadelphia, where its name comes from, was caused by an airconditioning system contaminated in just this way. Air washers Circulating water is sprayed into an air duct by means of fine nozzles. Then the larger water droplets are trapped by means of a separator and carried into a storage tank. This kind of equipment is installed not only in airconditioning systems but mainly also where the air is highly contaminated by dust. The main purpose is not only to humidify the air but also to clean the air from dust and dirt pollution. The washing water is highly contaminated with organic matter and, therefore, the risk of renewed contamination is much higher than in the above-mentioned atomizer type. Air washer (very high degree of risk) 4/8

Solutions The goal -the prevention of disease- can be achieved by keeping the growth of germs in the waterbearing parts of the equipment very low. Water analysis The water quality in all water-bearing parts of air-conditioning systems should be checked regularly. The results may be a cue for possible further action or may confirm the effectiveness of a measure taken previously. Sanosil Minilab Testkit vs Legionella Number of pathogens/ml of water or m 3 of air 0-500 500-1000 1000-5000 5000-10,000 10,000+ Recommended measures No action Research into causes, air analysis, first countermeasures Immediate reconstruction of the airconditioning system Important: Limit concerning Legionella 1 CFU/ml water Disinfectants and ultraviolet lamps in the process water of air-conditioning systems It seems obvious that it would be desirable to protect all water-bearing parts of an air-conditioning system against microbial contamination simply by using disinfectants and/or ultraviolet lamps. As a matter of fact, these are extremely suitable measures, although with some restrictions: Many commercial disinfectants (e.g. chlorine bleach) are suitable only for shock-type disinfection and are not designed for continuous/maintenance disinfection. Otherwise they would get into the compartment air and then cause irritation of the mucous membrane and eyes. Furthermore, very few disinfection methods have a long-lasting effect and therefore it is impossible to carry out a precise dosage for the continuous treatment of water. 5/8

Ultraviolet irradiation of process water in air-conditioning systems effectively inhibits the growth of microorganisms but only if clean water is available (turbidity < 30 NTU). Even slightly turbid water caused by suspended particles can remarkably decrease the effectiveness of ultraviolet lamps. Sanosil disinfectants: Product description Sanosil disinfectants are highly effective, universally applicable, have a wide spectrum of action and are based on hydrogen peroxide and silver. By combining the effects of these components, they are ideally suited to water disinfection because, in contrast to most other biocides, they: first, have the power to penetrate biofilm; second, have a long-lasting effect; and third, practically 100% of the disinfectant decomposes into water and oxygen. Sanosil Disinfectants Working Principle The active substance used is hydrogen peroxide, an environment friendly substance. In a complex manufacturing procedure, the active substance is stabilized and boosted with silver, thus achieving a greatly improved effectiveness against microorganisms. The traces of silver efficiently inhibit a renewed contamination. The elemental oxygen (O2) separated by the hydrogen peroxide attacks the cell walls of the micro-organisms directly. 1. The chemical reaction between the oxygen and the cell wall molecules will cause these to be denatured and destroyed. This effect is intensified by the silver ions which form a bond with the disulfide bridge of certain proteins of micro-organisms, thereby inactivating or precipitating these proteins. 2. 6/8

Product varieties Sanosil disinfectants for water treatment are available in different concentrations and, depending on the particular application concentration, their effectiveness is practically identical. Product Sanosil Super 25 Highly concentrated disinfectant Sanosil S015 Concentrated disinfectant Sanosil S006 W Disinfectant - Concentration - Product type Handling requirements 100% solution To be handled by professional staff only 15% solution 6% solution May be handled by inexperienced staff after adequate training May be handled by inexperienced staff after adequate training - H 2 O 2 content - Transport classification - Warning symbols Contains 50% H 2 O 2 Hazardous good, UN2014 C, O Contains 7.5% H 2 O 2 Not a hazardous good Xi Contains 3% H2O2 Not a hazardous good Application of Sanosil disinfectants: 1: Cleaning & shock disinfection As soon as the water analysis indicates a critical hygiene level, the whole system should be cleaned mechanically (high-pressure cleaner [be sure to wear P3 respirator] and then disinfected. First, discharge the contaminated water. Then, spray the clean surfaces (empty basin, condensate separator, etc.) with a 3% Sanosil Super 25 solution or a 20% Sanosil S015 solution. Disinfect the pumps, pipes and nozzles by filling the storage tank with clean water. Then mix approx. 1000 ml Sanosil Super 25 or 6600 ml S015 per m 3 water and turn on the atomiser and circulating pump (do not switch on the ventilator fan). All watercarrying parts should come into contact with the disinfectant solution. After an application time of 8-12 hours (ideally overnight) the disinfection solution can be drained (the solution can simply be disposed of via normal drainage systems; neutralisation and rinsing are not necessary). The cleaned and disinfected system is then ready for operation. Ventilation and air-conditioning filter/screen shortly after adding Sanosil The detached biofilm is clearly visible Strong occurrence of biofilm Here all surfaces were sprayed with a 20% S015 solution prior to mechanical cleaning to reduce the biological risk for cleaning staff. After cleaning, the water was disinfected for a second time and subject to shock disinfection. 7/8

2: Continuous disinfection / Subsequent treatment This involves continuously mixing a small amount of Sanosil into the fresh water in a clean system. The dosage depends on several factors, including water temperature, organic load, quantity of fresh water, etc. Continuous disinfection can greatly improve the ventilation and airconditioning cleaning cycle and keep it within hygienic levels. Typical dosages are as follows: Super 25 = 10-30 ml/m 3 ; S015 = 60-200 ml/m 3 ; S006W = 120-450 ml/m 3. While the exact dosage for Super 25 and S015 can only be applied with a dosage pump, S006 W can be used with a Dosatron D3 RE 3000 proportional dosage device. Manufacturer Sanosil Norge AS, Brannfjellveien 86 A, 1181 Oslo Tlf.: +47-908 52 546 E-post: post@sanosil.no sanosil.no Use biocides safely. Always read the label and product information before use. Our operating instructions, both oral and written, are based on extensive tests. Our advice is given to the best of our existing knowledge but is not binding insofar as the application and the storage conditions lie beyond our direct control. The description of the products and details of the properties of the compounds do not subsume any liability for damage. 8/8