Copy of article submitted to Fire Safety Engineering for publication January/February 2009

Similar documents
ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

Essentials of Fire Fighting 6 th Edition Firefighter I

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Anatomy of a Fire. Christopher Crivello, MSFPE, PE. Douglas Nadeau, MSFPE, PE, CFPS, LEED AP

( )

Development of a Test Procedure for Sandwich Panels using ISO 9705 Philosophy

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

Max Fire Box Users Guide

Significance of the Construction Products Regulation, including for data centers WHITEPAPER

Construction Products Regulation (CPR) and cables. British Cables Association Guidance to Specifiers

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

ISO/TR TECHNICAL REPORT. Reaction-to-fire tests Full-scale room tests for surface products Part 2: Technical background and guidance

OXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

REVIEW ON TWO PERFORMANCE-BASED TESTS FOR ASSESSING FLAME SPREAD IN HONG KONG

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

ASSESSMENT OF TIMBER PARTITION MATERIALS WITH FIRE RETARDANTS WITH A ROOM CALORIMETER

ISO INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

Large-scale fire test for interior materials of the Korean high speed train

Facts about insulation and fires 29 October 2014

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

The phenomenon of the flashover and backdraft. Backdrafts and flashovers. Backdrafts, rollovers and flashovers

Contact person Date Reference Page Richard Johansson P (2) Fire Research

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CPD Seminar: Importance of Reaction-to-Fire Properties of Materials: Combustibility, Spread of Flame and Smoke Generation

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Real-scale dwelling fire tests with regard to tenability criteria

Fire fighting Questions

IMPROVEMENTS OF TEST METHOD FOR WATER MIST SYSTEMS - CEN/TS 14972:2008, ANNEX A.3.

ISO 2685 INTERNATIONAL STANDARD. Aircraft Environmental test procedure for airborne equipment Resistance to fire in designated fire zones

First Revision No. 6-NFPA [ Section No. 2.2 ]

So, How do Fire Starts & Spreads? A question we need to understand and appreciate the dynamics of fire life cycle.

Plast Utveckling och användning av brandtester i mellanskala för plastprodukter Del 1: Allmän vägledning

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

To understand FIRE and how to EXTINGUISH it, we first need to know: What is FIRE?

This document is a preview generated by EVS

Not all insulation is the same! from fire testing to real fires.

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS

Eligibility criteria

Üntel is ready for CPR

SUBJECT: ASSESSMENT FOR INTERNAL SURFACE FINISHES OF LIGHTBETON PANEL FOR COMPLIANCE WITH THE NEW ZEALAND BUILDING CODE(NZBC)

UK Direction BS7671 BS 8492 BS /01/2018

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Fire Safety. Version 1.0

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

At the end of this study topic, you will be able to discuss the chemistry of fire; discuss the fire dynamics in a compartment fire; and explain the

Ventilation Effects on Fire Patterns during Post Flashover Burning

INTERNATIONAL STANDARD

ISO/TR TECHNICAL REPORT. Fire-safety engineering Technical information on methods for evaluating behaviour and movement of people

BUILDING FIRE SAFETY AND HAZARD ASSESSMENT METHODS FOR COMBUSTIBLE SURFACE FINISHES C.A. WADE

2.2 Factors in design

Fire Safety Fire Resistant Building Components

Are Your Kitchen Hood Filters Compliant?

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Figure 1. Structure Used For the Simulations.

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

National Fire Authority

This document is a preview generated by EVS


ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

AS/NZS :2008

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

Method for testing the suppression performance of fire suppression systems installed in engine compartments of buses and coaches

Experimental Room Fire Studies with Perforated Suspended Ceiling

Tampa, FL Fire Cause Classification Task Group Tue, 14 April 2011

SAFETY NOTE. Published by: SC-GS Date of publication: June 2004 Original: English

Available online at ScienceDirect. Procedia Engineering 62 (2013 ) Charles M Fleischmann a, *, ZhiJian Chen b

HYDROCARBONENGINEERING June June 2015

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

Chapter One Commercial Kitchen Fires

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

Test Report: ICL/CR15/11/087

Abrasion Resistance of Fluoropolymer and polyester Coatings

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Materials Testing by Gregory Havel

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Europacable FAQ on CPR Status: 26/01/17

Identifying and Preventing Dust Fire and Explosion Hazards

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Determination of the resistance to jet fires of passive fire protection materials Part 1: General requirements

Indicative hoarding fire experiment. Prepared for: London Fire Brigade. 21 May 2014 Client report number

New European Cable Testing and Classification

Paper presented at the International Symposium on Protection of Cultural Heritage Buildings from Fire, Kyoto, Japan, April 6 7, 2003

INSPECTOR I SKILLS ADMINISTRATION

Transcription:

Copy of article submitted to Fire Safety Engineering for publication January/February 2009 Metal faced sandwich panels with plastic foam cores - a challenge to fire safety by Gordon Cooke Confusion, misleading terminology and classification Some manufacturers of insulation boards and sandwich panels use ill-defined terms implying fire safety to their products for marketing purposes terms such as inflammable, fireproof, self extinguishing, equivalent to non-combustible, and recently firesafe. To the unwary specifier a term like Firesafe might suggest that the product is inorganic or non-combustible or will not contribute heat or smoke to a developing fire. PIR and phenolic foams may have better fire properties than PUR foam or polystyrene foam (expanded or extruded). However, both PIR and phenolic foams, like all plastics, are derivatives of the petrochemical industry and so it is not surprising that these materials can, in the event of a fire, contribute to fire. If materials become involved in flashover they can contribute significant amounts of heat, together with toxic smoke; The recently approved product standard for metal faced sandwich panels EN 14509 [1] does not make the distinction between the fire properties of panels any easier. Despite criticism and a failed first formal vote the standard still refers to the SBI test [2] for the reaction to fire testing of metal faced sandwich panels. The problem with using the SBI test for metal faced sandwich panels is that it does not distinguish between panels which cause flashover in the reference scenario from those that do not [3, 4]. It also is not possible to distinguish between panels with different types of combustible cores despite the well-known fact that some plastic foams have better fire properties than others. Eumeps (European manufacturers of EPS) writes in one of their reports [5] that: Extensive research has been carried out on the reaction to fire classification for steel sandwich panels. This clarifies that it is not the core materials which determine the classification but the coating that is applied on the outsides of the steel. All published test results of metal faced sandwich panels tested in the SBI test confirms the statement from Eumeps as all plastic foam cored panels obtained a Euroclass B classification [3,4,6]. So why is it a problem that all plastic foam cored metal faced sandwich panels obtain a Euroclass B? The answer is: because Euroclass B is the class reserved for combustible products which will not cause flashover when tested in the large scale reference test ISO 9705 [7]. Unfortunately most plastic foam cored metal faced sandwich panels will cause flashover when tested in the large scale reference test ISO 9705 or the similar free standing test ISO 13784-1 [8]. Importance of flashover Flashover is internationally accepted as a major life threat condition not only to the normal building occupants but also, critically, to fire fighters, and it is also a threat to property and must be avoided if possible. Flashover is the condition in a growing fire within an enclosure (room or compartment) when all the materials (room contents and

at least the room s upper surface linings) suddenly all become involved in flame, Figure 1. Typical example of flashover in the ISO 9705 reference room test (flames emerge from doorway, upper surfaces of specimen involved in fire) Flashover should not be confused with backdraft which is an explosion occurring from the sudden introduction of air into a confined space containing oxygen-deficient superheated products of incomplete combustion. Flashover is internationally accepted as a failure criterion in the ISO 9705 reference room test and typically takes place when the combustion gases under the ceiling reach a temperature of around 600degC. At flashover there is a sudden and large increase in feedback of thermal radiation from the hot gas layer to the room contents below, and the effect of the radiation is to greatly increase the rate of flammable volatiles given off by the fuel (the room contents and room linings). This is reflected in a dramatic increase of burning rate and, consequently, an increase in the rates of heat release and smoke production. Combustion gas temperatures after flashover can range from 600degC to over 1300degC in real compartment fires.

Figure 1. Flashover and the three phases of fire The large scale reference test ISO 9705 The ISO 9705 test uses a standard room 3.6m x 2.4m x 2.4m high with a single ventilation opening in one of the narrow end walls to simulate an open doorway giving a well ventilated fire condition. The room is lined on three walls and the ceiling with the product. A small ignition source (matrix gas burner), located in contact with the two walls in a corner of the room away from the doorway, is set to give 100kW heat output in the first ten minutes followed by 300kW for the next ten minutes. Note that 100kW is roughly the peak heat release rate from a burning waste paper basket. The test room uses a 3m square hood next to the opening to collect all the combustion gases and has an instrumented duct capable of accurately measuring several exhaust gas parameters including rate of oxygen consumption (from which heat release rate is determined) and optical density of the smoke, Figure 2. If flashover occurs within the 20 minute test period the product is deemed to have failed the test. Flashover is deemed to occur when the sum of rate of heat release from the ignition source (100kW or 300kW) and the surface product reaches 1000kW and usually coincides with flames emerging from the door opening.

Figure 2. ISO 9705 Room reference test apparatus (copied by courtesy of SP). ISO 13784-1 an alternative large scale test for sandwich panels In addition to ISO 9705, ISO has developed a large scale test specifically for sandwich panels (ISO 13784-1) based upon the same scenario and philosophy as the ISO 9705 test. This test uses a test room of the same size as that described for ISO 9705 build up of the panels themselves. This allows for the panels to be mounted either completely free standing or fixed to either an internal or external frame. The test also measures heat release and smoke production as is done in ISO 9705. It should however be noted that the large-scale Room Corner Test ISO 9705 remains the official reference test within the European classification system for the reaction to fire performance of all construction products except floorings, including sandwich panels. Life safety So where do we look to get guidance relating to insulation boards and sandwich panels and life safety issues. We must turn to the Building Regulations 2000 (as amended). The relevant functional regulation is given in Part B of Schedule 1 to the regulations and is reproduced below Internal fire spread (linings) B2. (1)To inhibit the spread of fire within the building, the internal linings shall: (a) adequately resist the spread of flame over their surfaces; and (b) have, if ignited, a rate of heat release or a rate of fire growth, which is reasonable in the circumstances Note the requirement for a reasonable rate of heat release or rate of fire growth. We know that Approved Document B Fire Safety is the government s official (benchmark) guidance for deciding whether or not a building is safe from fire, in terms of life safety of building occupants and fire fighters, and if the building meets the fire regulations. What does ADB say about sandwich panels? The 2006 edition recognises the fire risk posed by some sandwich panels. Accordingly it includes Annex F Fire behaviour of insulating core panels used for internal structures. This recommends that a fire risk assessment is made and it gives some pointers as to what matters to consider. While this raises awareness of the fire risk of some sandwich

panel constructions it does not, in my opinion, go far enough. ADB ought to be redrafted to make it clear that: a) the Single Burning Item (SBI) test, Figure 3, which is one of four standard small scale fire tests used in deriving a European class (Euroclass) for a surface product, is unable to assess the fire behaviour of sandwich panels owing to the small size of specimen tested (maximum wing size 1m by 1.5m high), and b) any sandwich panel construction should be submitted to the large scale reference test ISO 9705, as this was specifically designed to assess the rate of heat release (a requirement of the functional regulation as we saw above) and smoke production, and decide whether or not a sandwich panel assembly will result in flashover. Figure 3. BS EN 13823: 2002 Single Burning Item test apparatus. (Note small size of specimen) Conclusions. Metal faced sandwich panels with a plastic foam core should not be described in a way that implies a degree of fire safety that is not proven by tests and classification systems as discussed above, and their use in buildings should be critically considered in the knowledge that they are combustible. In some building configurations metal faced sandwich panels with a plastic foam core may be safe (e.g. when the panel is located well away from any ignition source or when the enclosure is very large), but assuming the initiating fire develops there will come a stage where the foam could contribute to the fire. Defining the scenarios in which the product will not contribute to flashover is very difficult. Specifiers should be aware that the LPS 1181-1 test, often cited in manufacturer s literature, may be inappropriate to the life safety scenario. BRE has confirmed this fact in a recent News release. The SBI test is inappropriate to test metal faced sandwich panels as it cannot distinguish between panels that will cause flashover in the reference scenario from those that will not.

AD B should be amended to require the performance of sandwich panels containing combustible cores such as plastic foam to be determined in accordance with the ISO 9705 room reference test or ISO 13784-1. If in the absence of this large-scale test data the product specifier, having made a full fire risk assessment, remains in any doubt, it will be prudent to specify non-combustible materials - i.e. materials that have a Euroclass class of A1 or A2 when tested directly exposed to the test heat source. References [1] EN 14509: 2006, Self-supporting double skin metal faced insulating panels - Factory made products - Specifications [2] BS EN 13823: 2002, Reaction to fire tests for building products Building products excluding floorings exposed to the thermal attack by a single burning item [3] Van Hees P, Johansson P. Development of a Test Procedure for Sandwich Panels using ISO 9705 Philosophy. Nordtest project nr 1432-99. SP Rapport 2000:26, SP Swedish National Testing and Research Institute, Fire Technology, Boras, 2001. [4] Jesper Axelsson and Patrick Van Hees, New data for sandwich panels on the correlation between the SBI test method and the room corner reference scenario, Fire and Materials, 2004 [5] Eumeps, Fire safe constructions with EPS, http://www.eumeps.org/pdfs/firesafe.pdf [6] BRE, Final Report for Sector Group C Sandwich Panels, October 2003 [7] ISO 9705: 1993 Fire tests Full scale room tests for surface products. [8] ISO 13784-1: 2002, Reaction to fire tests for sandwich panel building systems Part 1: Test method for small rooms End of article