Radionics D4112 Program Sheet

Similar documents
2000 Series. Program Entry Guide. Control Panels

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

First Alert 1200C Installer Notes M. Leuck

Property of Monitronics Inc

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Property of Monitronics Inc

Condominium Security Management System

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Tomorrow s technology for today s security needs.

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Contact ID as of 2/2/2015

LED Keypads D720 Series User s Guide

D1265. User's Guide. Touchscreen Keypad

VISTA-100 Commercial Fire & Burglary Partitioned System

Control/Communicator

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Fire Command Keypad. XR5 User s Guide

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

Security System. User s Guide for the Text Command Center

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Security System. User Guide for the LED Command Center

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Table of Contents. Page Code

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

EasyLoader. Integrated Alarm Control/Communicator. Year 2000 ready. Express Installation and Operation Manual. Edition II

Version 1.03 January-2002 USER S MANUAL

Contact ID as of 11/28/2018

XR10 Command Processor Panel Programming Guide

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

TABLE OF CONTENTS TABLE OF CONTENTS 1

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Solution-8248 Installation Manual ISSUE 1.16

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

Training Manual Multi-Language with Wireless

Contents. Glossary

INSTALLATION MANUAL & PROGRAM RECORD SHEET

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Quick Programmer s Manual

Independent Zone Control (I.Z.C.)

SENTROL ZX400/ZX410. Security System Control. Programming

PROGRAMMING PROCEDURES (Table 3)

User s Information Guide R2A

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

ITI Caretaker Basic Commands

Control/Communicator Installation Manual

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

AXI LED USER MANUAL (REV. 1.0)

CC408. Quick Reference Guide Solution 880

RE6100 Series Helix Security and Automation Platform

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

CONTACT ID REPORT CODES

Summit 3208GLD USER MANUAL. Electronics Line

INSTALLATION MANUAL PC25OO

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

CC488. Quick Reference Guide Solution Ultima 880

Watchguard WGAP864 User Manual

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Release Notes for Version 7.05 January 2007

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

L900 series USER MANUAL

NetworX NX-8V2. LED Keypad User Manual

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

NX-148 LCD CODE PAD TABLE OF CONTENTS

Destiny Destiny Owners Manual

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

SPECIFICATIONS Control Panel Specifications Remote Keypad Specifications 21 zones including: (PC3000RK) Audible alarm output:

NESS 5000 SERIES DIALLER

HILLS Series LED Code Pad User Manual

Solution-16/ Solution-16 Safecom Installation Manual ISSUE 2.10

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

IDS816 User Manual H Issued January 2009

System Programming Guide

DS7400Xi (version 3+) Security System User s Guide

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

GV2 Series Control Panels

Solution Ultima Series Operators Manual ISSUE 1.00

FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A

Digiplex LED Keypads User s Manual

Transcription:

Programming only by downloading, 5200 Programmer or 5100 "Wand" Programmer Plug programmer in and momentarily short Reset Pin to Terminal 25 to enable program mode 1. Account Account # I I I I I (0 to 9, B to F) Disable Sys I NO I No = Not Disabled, Yes = System shut down Local I NO I No = Reporting, Yes = No Reporting Entry Delay I _0 _I _3 _I _0 _I 10 to 120 seconds, Blank = No Entry Delay BuzzACFail I NO I No = No Buzzer on AC Fail, Yes = Buzzer on AC Fail Entry Delay I _0 _I _6 _I _0 _I 10 to 120 seconds, Blank = No Entry Delay Prewarning I YES_I No = No Buzzer on Entry Delay, Yes = Buzzer on Entry Delay Device1Type I _2 _I Keypad 1 Type BLANK = No Device 1 = D611 LED keypad Device1Type I _2 _I Keypad 1 Type 2 = D420 or D620 LED keypad 3 = D630 or D636 Alpha Keypad 2. Passcodes Passcode1 I _2 _I _3 _I _4 _I _5 _I 0 to 9 Passcode2 I I I I I 0 to 9 Passcode3 I I I I I 0 to 9 Passcode4 I I I I I 0 to 9 Passcode5 I I I I I 0 to 9, can be used as Duress if "Duress Type" enabled User ID I NO I No = Disabled, Yes = Identify O/C Reports by User Passcodes Passcode1 = Zone 1 Passcode4 = Zone 4 Passcode2 = Zone 2 Passcode5 = Zone 5 Passcode3 = Zone 3 RAM or Command 1 = Zone 9 Duress Code I I 0 to 9 if BFSK format 0 to 9, B to F if Modem II format Duress Type I PASSCODE + 1 I Passcode + 1, Passcode + 5 (To enable Duress User ID must be YES, Opening Report must be C, Closing Report must be C) 3. Phone PPrefix# I _1 _I _8 _I _0 _I _0 _I I I I 8-digits 0 to 9 (Just put 1800) C = 3 second pause D = 7 second Dial Tone pause PPrefix# I _? I _? I _? I _? I _? I _? I? I 7-digits 0 to 9 (Rest of phone goes here) APrefix# I I I I I I I I I I (Alternate Phone, not used) APrefix# I I I I I I I I I DTMF Dial I YES_I No = Pulse Dialing, Yes = DTMF Dialing CS Format I _? _I 7 = Radionics Modem Format 6 = Radionics BFSK Format 5 = Radionics Single Round with Parity Use 7 if Radionics C Receiver 4 = Ademco High Speed Double Round 3 = Silent Knight High Speed Double Round Use 6 if on Virtual Receiver 2 = Ademco Low Speed Double Round 1 = Silent Knight Low Speed Double Round 1400 Hz Ack I NO I No/Yes (Default) Always leave at No 2300 Hz Ack I _? _I No/Yes (Default) Yes if using Virtual Receiver No if using Radionics C Receiver AlarmRoute I _ 1 _I Default = 0 0 = Primary Phone Only 1 = Primary then Secondary Phone OP/CL Route I _ 0 _I Default = 0 2 = Alternate then Primary Phone 3 = Primary - Not designated Trouble Route I _ 1 _I Default = 0 Secondary - Designated Restore Route I _ 0 _I Default = 0

4. Remote Program Passcode I _9 _I _9 _I _9 _I _9 _I 4-digits 0 to 9, B to F Blank = No Remote Access AnsArmRings I _0 _I 5 _I 0 (Default) to 14 Rings Blank = No Answer AnsDisRings I _1 _I 2 _I 0 (Default) to 14 Ring Blank = No Answer 5. Tbl/Restorals Trouble Code I _F _I 0 to 9, B to F, Blank (F is automatic if BFSK or Modem II is used) Restoral Code I _E _I 0 to 9, B to F, Blank (E is automatic if BFSK or Modem II is used) Expanded T/R I NO I No/Yes (Default) (Transmit Expanded Trouble & Restorals) DelayRestore I NO I No (Default)/Yes (Delays Restorals until Siren Timeout) 6. Open/Closings Opening Code I I 0 to 9, B to F, Blank (B = Default) Closing Code I I 0 to 9, B to F, Blank (C = Default) Restrict O/C I NO I No (Default)/Yes (Open after Alarm, Close if Force Armed) Cancel Code I I 0 to 9, B to F, Blank (Leave Blank) 7. Bell Options Bell Time I _ 0 _I _ 6 _I 00 to 63 minutes (Default = 06) Test Bell I NO I No (Default)/Yes (Bell Test after Armed) One Ring I YES_I No (Default)/Yes (1 alarm per zone during Arming period) 8. Cmd Options Cmd1MstrArm I YES_I No/Yes (Default) (Enable Command 1 Arming (Quick Arm)) Cmd2InstPer I YES_I No/Yes (Default) (Enable Command 2 Arming (Instant Arm)) Cmd3DlyPer I YES_I No/Yes (Default) (Enable Command 3 Delayed Perimeter Arming) Cmd5PassChg I YES_I No/Yes (Default) (Enable Command 5 (Passcode Change Mode) Cmd6PerWatch I YES_I No/Yes (Default) (Enables Command 6 (Door Chime Mode) Cmd8PerPartl I YES_I No/Yes (Default) (Enable Command 8) (Perimeter Arm with Entry/Exit Delay) (Partial Arming by bypassing open zones) Cmd0ZnBypass I YES_I No/Yes (Default) (Force Arm with Passcode & Command 1, 2, 3) Force Arming I YES_I No/Yes (Default) (Enable Command 0 for Bypass while Arming) ForceArm Max I _ 1 _I 1 = Default 0 to 6 (Maximum Number of Zones for Force Arming) 9. Sys Test/Reset Cmd41RstRpt I NO I No (Default)/Yes (Enable Command 41 Expanded Restorals) Cmd42DiagRpt I NO I No/Yes (Default) (Enable Command 41 Expanded Restorals) Cmd44SysTst I NO I No/Yes (Default) (Enable Command 44 to send Test signal) (if No will also disable "A" Function key) Cmd47SmkRst I YES_I No/Yes (Default) (Enable Command 47 to reset smoke detectors) (if No will also disable "B" Function key) Battery Supv I _ 9 _I 0 to 9, B to F, Blank (Enables Low Battery Reports) (9 = Trouble & Restore Zone 9) 10. Special Cmds Cmd7RptCode I _ 7 _I 0 to 9, B to F, Blank (Command 7 Alarm Report Code) Cmd7Bell I NO I No (Default)/Yes (No Siren/Bell on Command 7 Medical Alarm) Cmd7PlsBell I NO I No (Default)/Yes (No Pulsed Siren/Bell on Command 7 Medical Alarm) Cmd7AltAlrm I NO I No (Default)/Yes (No Alternate Alarm on Command 7 Medical Alarm) Cmd9RptCode I _ 9 _I 0 to 9, B to F, Blank (Command 9 Alarm Report Code) Cmd9Bell I YES_I No (Default)/Yes (Enable Siren/Bell on Command 9 Fire Alarm) Cmd9PlsBell I YES_I No (Default)/Yes (Enable Pulsed Siren/Bell on Command 9 Fire Alarm) Cmd9AltAlrm I NO I No (Default)/Yes (Activate Alternate Alarm on Command 9 Fire Alarm)

11. Zone Codes Show Zones I YES_I No/Yes (Default) (Shows Zone Status while Disarmed) Default Default Zone Type (00000 if Zone not used) Zone1 Code I _0 _I _1 _I _4 _I _5 _I _4 _I Fire, Trouble and Restorals Zone2 Code I _2 _I _6 _I _1 _I _5 _I _0 _I Perimeter Delay, Trouble and Restorals Zone3 Code I _2 _I _2 _I _1 _I _5 _I _0 _I Perimeter Instant, Trouble and Restorals Zone4 Code I _2 _I _2 _I _1 _I _5 _I _0 _I Perimeter Instant, Trouble and Restorals Zone5 Code I _2 _I _2 _I _1 _I _5 _I _0 _I Perimeter Instant, Trouble and Restorals Zone6 Code I _1 _I _2 _I _1 _I _5 _I _0 _I Interior Instant, Trouble and Restorals Digit 1 = Zone Type 0 = 24 Hour Zone 1 = Interior Zone 2 = Perimeter Zone 3 = Priority 24 Hour Zone 4 = Priority Interior Zone 5 = Priority Perimeter Zone Digit 2 = Response to Open or Short 0 = No Trouble, No Delay, Instant Alarm on Open or Short 1 = Trouble on Open, Instant Alarm on Open or Short 2 = Trouble on Short, Instant Alarm on Open or Short 3 = Trouble on Open or Short, Instant Alarm on Open or Short 4 = Delay on Open, Instant Alarm on Short, no Trouble Conditions 5 = Delay on Open, Instant Alarm on Short, Trouble on Open 6 = Delay on Open, Trouble on Short, Instant Alarm on Short 7 = Delay on Open, Trouble on Open or Short, Instant Alarm on Short 8 = Delay on Short, Instant Alarm on Open, no Trouble Conditions 9 = Delay on Short, Instant Alarm on Open, Trouble on Open A = Delay on Short, Instant Alarm on Open, Trouble on Open B = Delay on Short, Instant Alarm on Open, Trouble on Open or Short C = Delay on Open or Short, no Trouble Conditions D = Delay on Open or Short, Trouble on Open E = Delay on Open or Short, Trouble on Short F = Delay on Open or Short, Trouble on Open or Short Digit 3 = Zone Alarm Local Response 0 = Silent Alarm, No Alarm Output 1 = Steady Alarm Output for Bells/Sirens 2 = Alternate Alarm Output Activation for Duration of Bell Timeout 3 = Alternate Alarm Output Activation and Steady Alarm Output for Bells/Sirens 4 = Pulsing Alarm Output for Bells/Sirens (Overrides single Bell per fault option) 5 = Alternate Alarm Output Activation (Overrides single Bell per fault option) 6 = Alternate Alarm Output Activation and Pulsing Alarm Output for Bells/Sirens Digit 4 = Central Station Reporting Options 0 = Non-Reporting, Local Zone only 1 = Standard Reporting Zone 2 = Designated Zone 3 = Swinger Shunt Zone 4 = Swinger Shunt, Designated Zone 5 = Standard Reporting Zone, Includes Restoral Reports 6 = Restoral Reports, Designated Zone 7 = Restoral Reports, Swinger Shunt zone 8 = Designated Zone Digit 5 = Local Zone Annunciation and Options 0 = No Options 1 = Invisible Zone 2 = Ring Siren/Bells until Zone Restoral 3 = Ring Siren/Bells until Zone Restoral, Invisible Zone 4 = Sound Buzzers for Zone Fault 5 = Sound Buzzers for Zone Fault, Invisible Zone 6 = Sound Buzzers for Zone Fault, ring Siren/Bells until Zone Restoral 7 = Sound Buzzers for Zone Fault, ring Siren/Bells until Zone Restoral, Invisible Zone

12. Test Reports TestPrimary I NO I No/Yes (Default) (Transmit Test Reports to Primary Phone) TestAlternate I NO I No (Default)/Yes (Transmit Test Reports to Alternate Phone) Test Code I I I 0 to 9 if BFSK format (Test Report Code, Blank = disabled) 0 to 9, B to F if Modem II format Test Code E I NO I No (Default)/Yes (Transmit Automatic Test Report Code) Interval I 1 _I 0 to 63, Default = 1 (Test Time in Days) IntervalDays I YES_I No/Yes (Default) (No = Test Time in Hours, Yes = In Days) DaysTilRpt I _I _I 0 to 63, Default = 1 (Number of Days until 1st Test Report) HoursTilRpt I _I _I 0 to 63, Default = 1 (Number of Hours until 1st Test Report) Defer Test I NO I No (Default)/Yes (Defer Test Reports when an Alarm Generated)

Basic Commands Panic Panic Special Alert Arm Away Stay Arm Instant Arm Partial Arm Disarm Reset Alarm COMMAND + 9 (This may be silent on some systems) COMMAND + 7 (sends specific alarm (Optional)) Enter Code + ENT key or COMMAND + 1 (All zone lights must be Off to arm) COMMAND + 3 (Motions are bypassed, doors/windows will still be delayed) COMMAND + 2 (Perimeter & Instant lights turn on, Motions will not arm) COMMAND + 8 (Arms all but open zones, bypasses motions) Enter Code + ENT key (Perimeter, Interior, Instant turn off) Press COMMAND + 4 to stop keypad flashing and reset system Reset Smoke COMMAND + 4 + 7 (If this does not work power down system and set for service) Bypass 1. Arm system with COMMAND + 1 2. Before Exit Delay expires press COMMAND + 0 3. Press zone to be bypassed (1, 2, 3 etc) + ENT key 4. Press ENT to end and allow system to finish arming (Bypassed zones will flash slowly on display) Force Bypass Door Chimes Alarm Memory Phone Test System Test User Codes 1. Open door or window 2. Arm system with either User Code + ENT or COMMAND + 1, 2 or 3) 3. Keypad beeps indicating Zone is open 4. Press COMMAND + ENT to force bypass (A forced bypassed zone may arm with rest of system if closed) COMMAND + 6 to turn On or Off There is no Alarm Memory COMMAND + 4 + 1 (If Phone test good system sounds 2 second tone) COMMAND + 4 + 4 (Press any key to end test) User Codes can be 3 or 5 digits in length, if old code is 5 digits new code must be 5 digits The 1st digit of New User Code must be the same as the Old User Code Do not make last digit 0 if using duress code Add Code Duress Code Trouble Display (Customer may change an existing code but cannot add a new one) 1. Press COMMAND + 5 (The COMMAND light will turn on) 2. Enter User Code you want to change + ENT key 3. Enter the new User Code + ENT key 4. Enter new User Code again + ENT key (The COMMAND light will turn off) One number above any User Code If system has a trouble it will sound a steady tone, press Command + 4 to try to reset AC Power Light - On =Normal, Flashing = AC Power Failure Reset Alarm - Disarm system, press COMMAND 4 to stop keypad flashing and reset system Trouble Messages - (Alpha only) Message Diagnostic Prgrmr Comm Err Diagnostic Device Comm Err Diagnostic Report Failed Diagnostic Telco Service Diagnostic Aux Power Diagnostic AC Power Failure Diagnostic Low Battery Diagnostic Keypad Wiring Diagnostic Hardware Fail Diagnostic Missing Ser Device Diagnostic Device Prog Err Diagnostic Int Software Diagnostic Checksum Fail Diagnostic Rom Fail Diagnostic System Normal Cause Bad connection to programmer (for installers) Noisy Environment or excessive wire length Communication Failure Phone Cord Unplugged or Phone service down Short on Aux devices or wiring AC Power Failure Low Battery (Duh) Faulty keypad wiring Internal Main Board failure Wiring problem Serial device does not match program Internal Memory Failure EEPROM Failure (Internal Panel) Internal Panel failure Nothing wrong, no fault found