Skipper's Mate. Sensor Testing. Version December Table of Contents

Similar documents
DEFA HOME. User Manual Base Unit PRO

Ion Gateway Cellular Gateway and Wireless Sensors

D3D Wi-Fi GSM Smart Alarm System -User Manual

Door/Window Sensor. Set-Up Guide

HEGA Ethernet Gateway Browser Interface Guide

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Water Hero P-100. P-100 Components:

DryLINK TRAINING Phoenix DryMAX XL and DryLINK

WiFi Hints & Tips. Contents. WiFi Hints and Tips 1. Page No. Section No. Title

Ontech GSM 9040/50. Reference Manual English -1 -

IntelliSync Thermostat / Mobile App Frequently Asked Questions

Sensor Cloud User Manual

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

[ [ ADMIN PANEL USER GUIDE

Alarms Updated 03/26/2018

i-vu CCN 4.0 Owner s Guide

INSTALLATION AND OPERATION MANUAL

User Guide UTI-IQCP. Control panel for setting and monitoring of UTI-INV internal temperature regulator. v EN

Carbon Monoxide Sensor

System. For a better understanding of this product, please read this user manual thoroughly before using it.

TV2 Room Pressure Monitor Quick Start Guide

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

CODE ALERT Enterprise Software User Guide

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

Monitor Alarms and Events

Door/Window Sensor. Set-Up Guide

CONTROL PANEL REMOTE FEATURES INFORMATION ACCOUNT SETTINGS CONTROL PANEL REMOTE FEATURES INFORMATION SETTINGS. Connected

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Glass Break Sensor. Set-Up Guide

Integration Test Plan

FortiNAC. Lightspeed Single Sign-On Integration. Version: 8.x Date: 8/29/2018. Rev: B

Operation Manual For model CM706E

SERVICE. Fixed price. Lower insurance premium in France, Sweden and Russia. Free technical support (9-17 CET) Automatic online upgrades.

3D_ISS. Integrated Software System. User Guide Manual

Contents. Introduction. Basic use... pg 3. App settings: Main Menu... pg 6. App settings: Profile Sub-menu... pg 7

inet Now Live Monitoring

Code Alert Series 30 Software User Guide

RAPID Alert System User Guide. RAPID Alert System. User Guide

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

User manual. Epi-Care mobile. Danish Care Technology ApS Energivej 3, DK-4180 Sorø version 1.15 Phone: Page 1 of 17

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

YachtSafe GPS Alarm Manual

TV2 Clean Room Monitor

Real-time Air Monitoring System

Digital Marine Exhaust Temperature Alarm

G4S SMARTalarm User Guide

Preliminary. SmarteLight v1.2 Manual. Revision: 1.0 Date: 12/4/2012. Revision: 1.0 Page i OmniSite

GSM RFID VOICE Alarm System

Sound Light & Entry Sensor (RMA-SLE-SEN) Installation Note

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

NextGen Home Security. Quick Reference Guide

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

vanwaltconnect VAN WALT Monitoring your needs

IMS Operation Manual. Version 1.1. Phonetics, Inc.

Advisor Advanced Mobile Application User Manual

V1.21: (Required for All Dryers with Static Sampler or Incoming MST Sensor, Good for All Dryers)

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website

RFT CARES Android App User Guide

Lighting Xpert Insight User Manual

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

SIMPLIFIED HOME SECURITY AND CONTROL

MultiSite Manager. Setup Guide

INTRODUCTION... VI I. IOS... 1

INTRODUCTION... VI I. IOS... 1

SALES SUPPORT DOCUMENT

What's new in LogTag Analyzer 2.8

Making the Most of Alarms

Cold chain monitoring technologies. Facility monitoring

Installation and User Instructions

ArchestrA Direct Connect

Getting Started Guide

MILAN VORTEX WIRELESS MOTION SENSOR USER MANUAL

VMD Guide for V960 Series Cameras

Smart Thermostat. Set-Up Guide

HERCULES 6 GRAPHICS SYSTEM

Front page TBA from Marketing. Network and Device Monitoring. Starter Kit

Cellular Monitoring System

Room Alert. Room Alert 32E/W, 12E, 4E & 3E. Temperature & Environment Monitoring... Made Easy! User s Guide & Reference Manual

IndigoVision Alarm Panel. User Guide

IQ PANEL USER GUIDE SMARTHOME.

Installing ProSeries 2005

Avigilon System Integration Guide. Avigilon Control Center with AMAG Symmetry Security Management System 7.0

Fusion Alarm System USER GUIDE

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

AirTest Technologies Inc.

Wacker Neuson Instruction Guide: Revision 6

INSTRUCTION MANUAL. stay ahead - stay informed 1. THE APP

Honeywell Total Connect Remote Services

status AW1 Plus WiFi Alarm System User Manual

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

Welcome to Unilux VFC Wall-mount Thermostat

Autoclave Operations Manual

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

RMS Monitoring Software System Startup

Configuration and Operation Manual for the Unipos

Transcription:

Version 1.0.2 18 December 2017 Table of Contents 1. Introduction...1 2. Types of Sensor and Alarm...1 3. Where Can I See Graphs?...1 4. Where Do I Change Settings for Graphs & Alarms?...2 5. Turning OFF Sensors...2 6. Testing Alarm Only Sensors...2 7. Testing & Recalibrating Monitoring/Alarm Sensors...3 8. Graph and Alarm Settings...4 1. Introduction This document is intended to help you test sensors and alarms. This version has been updated to include details for recent changes in Version 0.9.2.6. The sensors as part of are designed to be switched on at all times. If you wish to run the system WITHOUT sensor(s) you should ensure that they are disabled through software. The system will attempt to rectify (self-heal) an connection problems with sensors which may result in the Boat Control Unit rebooting if it attempts to solve the problem. If you wish to run the system at home without battery power you can obtain suitable transformers by looking for power to the Arduino Uno via Google. These are 9V with barrel jacks. 2. Types of Sensor and Alarm Sensors fall into two types : Monitoring/Alarm Sensors which provide regular reports plus optional alarms e.g. (Temp/Humid/Dew Point, Voltage, Barometric Pressure). You can choose not to send alarms or to send for only one function (e.g. Temperature) on a multi-function sensor Alarm Only Sensors (reed and PIR) which only provide alarms e.g. Bilge, Door/Hatch, PIR 3. Where Can I See Graphs? Graphs are ONLY visible via the web site. Visit https://www.skippersmate.co.uk and Login using your personal details. Graphs should be available for any sensors you have activated (see further sections for details) from this set of menus. Project Computers Limited 2017. All rights reserved. Page 1 of 5

4. Where Do I Change Settings for Graphs & Alarms? Settings which affect graphs and alarms are ONLY via the Boat system either locally via wireless if you are on board or remotely by visiting https://www.skippersmate.co.uk, and logging using your personal details and selecting Visit Boat (where you will be asked for a 2 nd level of login). Then choose the Settings menu and the appropriate sensor option (see more detail in Section 8). 5. Turning OFF Sensors If you intend to run the system WITHOUT sensors (for example, while setting up and testing the main system) you should : using menu item Control / Control Panel turn Sensors OFF using menu item Control / Alert Control Panel turn ALL OFF 6. Testing Alarm Only Sensors Power on Sensor Control Unit(s) using menu item Control / Control Panel turn Sensors ON using menu item Control / Alert Control Panel turn ALL ON using menu item Control / Alert Control Panel turn ON the appropriate switch (e.g. Bilge, Hatch, PIR...) Initiating an Alarm You will need to create an error condition to trigger an alarm. For example, you could manually open a hatch or move the bilge sensor to the top of its range. Sending Alarms Initiating an alarm should send an email and/or SMS to the contacts you have listed via your web site login. Single Alarm unless you choose to Reset - The system works on the basis that you don't want to be told every 5 minutes that your hatch is open or that your batteries are going flat. So the system sends a single alarm (or pair of alarms one email and one SMS). If you wish to receive further occurrences of THAT alarm use the link in the email. Receiving/Resetting Alarms Single Alarm - If you wish to reset the alarm you can click on the web link in the email this will reset the sensor data on your boat and show you a confirmation web page. Multiple Alarms if you wish to reset all alarms, please use the menu option on the boat menus Settings / Refresh Alerts and then hit the OK button. Project Computers Limited 2017. All rights reserved. Page 2 of 5

7. Testing & Recalibrating Monitoring/Alarm Sensors Power on Sensor Control Unit(s) (SCU) using menu item Control / Control Panel turn Sensors ON Once you have turned the sensors ON in the Control Panel the system should take readings on a regular basis. Any readings outside the parameters set by you (see the Settings menu) will be reported via Alarms see below in this section. Readings will be sent to the Central Server hourly and may be seen on graphs by logging in via the web site and using the Graphs meny. To see your boat's graphs, visit the web site https://www.skippersmate.co.uk login in with the details you provided and use the Graphs menu. You may find some older data on the system produced during the testing process by viewing earlier dates. Note that this test data may be intermittent as the result of various tests. Once you have the system running you should be able to see growing data from your sensors on graph(s). Graphing values (axes and normal range) can be changed using the Boat menus Settings / <Temp/Humid/DewPt> etc/ Alarms You may prefer to leave alarms off until you have tested further. Check via the web site login that the email and SMS details are correct (we modify these during testing and may forget to correct them sometimes!). check/amend the parameters for the sending of alarms using the Boat menu option (see Section 8 below) using menu item Control / Alert Control Panel turn ALL ON using menu item Control / Alert Control Panel turn ON the appropriate Initiating an Alarm You will need to create an error condition to trigger an alarm. For example, you could place a heat source near a THD sensor so that the temperature goes above the Maximum Alert Value. Sending Alarms Please see section 6 above. Receiving/Resetting Alarms Please see section 6 above. Project Computers Limited 2017. All rights reserved. Page 3 of 5

8. Graph and Alarm Settings Graphs There are 2 ranges which you can modify : Y Axis values Min and Max. Numeric may include negative numbers (useful for Dew Point, Temperature etc.) These define the extent of the graph Display Range Values may also include negative numbers. This the normal range for graphs shown in light green. This is purely visual and does not affect alarms. To save the new values, hit the OK button. Alarms Where you have multiple sensors of a given type (e.g. Temp in Cabin and Temp in Lazarette), choose the appropriate sensor from the dropdown. Current Reading is not editable but will display the reading from your selected sensor. Min and Max Alarm Values if a reading is below the Min Alert Value or above the Max Alert Value an alarm will be triggered. Email Alarms - The alarm will be sent by email using the email address stored centrally (use the web site login and select the Settings menu / Email Contacts. You can have up to 5 email addresses so if you may be away from the boat you could, for example, add an email address for the marina or a local friend. Please obtain their permission before entering someone else's email address. There is no limit to the number of emails which may be sent by the system. SMS Alarms The alarm will be sent by SMS using the mobile phone no(s). stored centrally (use the web site login and select the Settings menu / SMS Contacts. You can have up to 5 numbers so if you may be away from the boat you could, for example, add a mobile number for the marina or a local friend. Please obtain their permission before entering someone else's mobile phone number. SMS messages are limited but top-ups can be purchased if you use up your allowance. You will receive an email notification if you are about to run out of SMS tokens. A new allowance is added when you renew your subscription to the central service. For more details please view the web site or contact us via the forum or email. Re-calibration You may wish to calibrate some sensors either because you want the output to match other Project Computers Limited 2017. All rights reserved. Page 4 of 5

systems you have on board (e.g. voltage/temperature) or because the sensor is not quite accurate. To recalibrate a sensor : Where you have multiple sensors of a given type (e.g. Temp in Cabin and Temp in Lazarette), choose the appropriate sensor. In addition, where you have a multi-function sensor (e.g. Temp/Humid/DewPt) you may need to use each tab to recalibrate the individual setting. Hit the Recalibrate button (e.g. Recalibrate Temp). The Current Reading will now become editable. You can now use one of two methods to adjust the sensor reading until you are happy it is correct : Use the up/down arrows in the Adjustment % field Use the slider bar These will adjust the figure Current Reading. When you are satisfied, hit the Save button. If you have multiple sensors or multi-function sensors you can adjust these. IMPORTANT before closing the program make sure you hit the OK button to save the results. This task can be repeated but is recommended that you close the program and re-open program if you wish to adjust further. Project Computers Limited 2017. All rights reserved. Page 5 of 5