INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates.

Similar documents
INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool AC/DC and DC only Refrigerators and Freezers.

SEA FROST BD 12 OR 24-VOLT D.C. AIR-COOLED SYSTEM

SEA FROST BD 12 OR 24 VOLT D.C. SYSTEM With Water Cooling Option

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

For Models: DE 441, DE461, DE451, DE490, DC440, DC451, DC490, MRFT415, MRFT440, MRFT460

MEDI-KOOL. Rx CLIMATE CONTROL UNITS INSTALLATION INSTRUCTIONS AND OWNER S MANUAL PRODUCED BY:

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.

SOLAR POWERED FRIDGE/FREEZER

Service Manual. DCXXXX, DEXXXX Model Compressor Refrigerators MODELS DC0040(K), DC0051(K) DE0040, DE0051 DE0240T, DE0251T DC0740(X), DE0740(X)

Owner s Manual. For Australian refrigerator models: N304.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

SEA FROST SHORE ASSIST SA-1 R-12 THIS MANUAL IS SUPPLEMENTAL TO THE SEA FROST R-12 ENGINE DRIVE MANUAL INSTALLATION INSTRUCTIONS

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

SOLAR POWERED DC FRIDGE

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

LEC L6014W/S User Manual

TFFR01 MANUAL PORTABAL 12/24 VOLTS DC REFRIGERATOR / FREEZER.

Upright Freezer Congélateur vertical Congelador vertical

User Manual & Operating Instructions

User Manual / Installation Instructions

Product Information and Technical Guide

Upright Freezer 048-GM-48307

SOLAR POWERED DC FRIDGE

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

User Manual. Wine Cellar

SOLAR POWERED DC FRIDGE

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

SOLAR POWERED DC CHEST FREEZER

Product Information and Technical Guide

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Norcold Repair Guide for Ice Maker

SOLAR POWERED DC FRIDGE

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

CAUTION. No-Load Performance, Controls in Normal Position

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

Product Information and Technical Guide

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET NOVA

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

PERFECT CHILL WINE CHILLER. USE AND CARE MANUAL MODEL Bottle

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Service Manual Model 3163

PRELIMINARY INSTALLATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56

PWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

DOMETIC PTY. LTD. Camping Boxes-Refrigerator. Models: RC 1600 EGP Type: JCB - 1. Operating Instructions AUS

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

TC-5231 Series, TC-5232, & TC-5241 Series

Installation Instructions for. OmniFount

AG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL

Combi Box 3 Way Fridge & Freezer

Compact Refrigerator. Hoffman Estates, IL Model: cu. ft. Capacity. Installation. This Manual!

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Installation Instructions for. DairyFount Series Fountains

Product Information and Technical Guide

Sears, Roebuck and Co., Hoffman Estates, IL 60179

Instructional & Operating Manual

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Compact Refrigerator. User Manual Model 3590A

Instruction Manual MODEL: GDUF Cu. Ft. Capacity 120V~, 60Hz, 115W

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

T-Series Air Conditioner T15 Model

FF71 COMPACT REFRIGERATOR-FREEZER INSTRUCTION MANUAL. Write Serial Number here:

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

an ISO 9001:2008 Registered Company GOLL ST. - SAN ANTONIO, TX ph fax MINI SPACE SAVER HEAT /COOL

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

Table of Contents SPECIFICATIONS Page 2. FOR THE INSTALLER Page 3. FOR THE PLUMBER Page 4. INSTALLATION Page 5. INITIAL START UP Page 6

MINI SLIMLINE COOL VUY-A VUY-A

Safety Information Operating Instructions Care and Cleaning...7, 8 Control Settings...5 Refrigerator Features...

T-Series Air Conditioner T20 Model

KellllRlore REFRIGERATOR. Safety Instructions Installation Operation Care and Maintenance Troubleshooting Parts List

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

ICE CREAM DISPLAY MANUAL OF INSTRUCTIONS FOR USE AND INSTALLATION

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

PORTABLE REFRIGERATOR

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

DS-5C RAIN/SNOW SENSOR CONTROLLER INSTALLATION INSTRUCTIONS

Portable Refrigerator

Ice Maker. Model BIM25. Instruction Manual. Write Serial Number of unit here:

User s Guide for the SunDanzer BFRV55

DOUBLE DISHDRAWER TM DISHWASHER

All about the Use &Care

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

Surna 25-Ton Chiller Operating & Maintenance Manual

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

12,000 BTU Evaporative Portable Air Conditioner

Transcription:

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates. Thank you for choosing Nova Kool for your refrigeration needs. For over 20 years we have been providing quality DC & AC/DC products for mobile, off power grid and energy conscious installations around the world. Each unit goes through a series of tests to ensure strict compliance with our quality policy Strive for continual improvement of all business processes while involving all associates in the management of quality. Your unit has been run test at the plant for a minimum of 12hrs, followed by a series of inspections and electrical tests to ensure the quality, the reliability and the safety of your unit. All Nova Kool units are covered by a 2-year parts warranty that commences upon delivery of the unit to the end user customer. Please take the time to fill in the information below which can be found on the inside of your new refrigerator. This will help when phoning for service or warranty information. Model # Serial # Date of Purchase: Date of Del of Vessel: (Or vehicle where applicable) Selling dealer: Our service department can be reached at 604-523-6515 ext 104, or at support@novakool.com from 7:00am to 5:00pm PST NKF 50 Revised December 2013

Thing s you need to think about before you cut your first hole 1. Where do you want to mount the condensing unit? Closets, cupboards, bilge, engine room, lazarette, are all good locations. We are not ignition protected so take caution when mounting around gasoline engines. Keep in mind no matter where you mount it you will need to ventilate the enclosure. We recommend 120 sq. inches. Ideally 60 coming from the cabin and 60 going back out to the cabin. 2. Do you have access to power close by? The shorter the run the less voltage drop in the wiring and the lighter the gauge of wire required. Most installations will require a minimum of 10 gauge wire to the unit from the battery. If you are using a breaker it should be a 20 amp dc breaker to minimize voltage drop. Size Max length Max length AWG 12 vdc 24 vdc Gauge mm ft. m ft. m 14 2.5 8 2.5 16 5 12 4 13 4 26 8 10 6 20 6 40 12 8 10 32 10 65 20 The wire length is the distance from the battery to the unit. A quick note: The unit knows the difference between 12vdc and 24 vdc. It will run on either one right out of the box.

3. How far is the cooler or freezer box going to be from the condensing unit? The standard unit comes with a line set of refrigerant tubing 12 feet (4 m) long. (Factory order of up to 20 feet (7 m) available special order) Are you building a cooler, a freezer or a spill over? A spill over application is when you have one cooler box and you want to make this cooler box part freezer and part cooler. This is done by putting a dividing wall between the cooler and the freezer. The cold plates are mounted in the freezer side and the dividing wall has an opening at the bottom and the top to allow the cold air from the freezer to go into the cooler side and as it warms return to the freezer side. If your box is mostly refrigerator but you would like a little freezer, then you would put the RT6 or the RT4 evaporator box in. It can be mounted as a front or top opening. The RT6 box gives you close to ¾ cu. ft. of freezer space. RT6 RT4 If you want all freezer or all refrigerator or the spill over use the F plates or one of the other evaporators that fit your box the best. You can always call 604-523-6515 for more information. F plates FL plate (large) FM plate (medium)

Let s get started installing the unit 1. Take a look at the path you will be running the copper line kit. You get about three bends from the copper before it work hardens and will not bend any further. So it is real important to know where you are running it before you start with the bends. Unroll the copper tube on a flat surface. Cut a 1 ½ inch hole in your box where you want the line kit to exit and go towards the condensing unit. Keep the hole plug to fill the hole after you run the couplings through the hole. You will need to notch the plug for the line set before re installing the plug in the hole A quick note: Do not cut the line set; roll up unused portion before making final connection to the condensing unit. Mounting the cold plates Cold air drops; with this in mind it is important to mount the cold plates as high up the wall of the box as you can. The cooling will start at the top of the cold plate and continue down to the bottom of your box. If you want a cooler place in your box but not a real cold space, mount the cold plates a little lower in your box and the space above the cold plates will be the warmest part of your box. You can mount the cold plate in any direction. It is important to keep the tubes that come out of the cold plates away from any standing water that may form in the box during operation or defrosting. If the tubes are sitting in the standing water electrolysis may form shortening the life of your unit.

Your cold plates have mounting holes and hardware included to help with the installation. If for some reason you need more mounting holes you can drill into the cold plate but must keep the drill and hole at least ½ inch (10 mm) from the raised pattern on the cold plate where the refrigerant flows. On the line set is a 3 foot piece of black foam insulation. This piece is to be positioned at the outlet of your refrigerated box. Just slide it into position. Mounting the thermostat and sensing tube The thermostat is housed in a plastic enclosure that you will mount inside your box with two screws. The knob is marked from 1 to 7. All the way clockwise will get you to 7, which is the coldest setting. Go counter clockwise to 1 this is the warmest setting. Go a little past 1 to shut the unit off. The setting on the thermostat will regulate the temperature in the box. The thermostat has a metal sensing tube that must mount to the cold plates for proper operation. Depending on your cold plate, you will have two tabs or a cover plate and screws to mount the sensing tube under. Do not cut the sensing tube if it is too long. Coil it up without kinking the tube. The thermostat sensing tube enters in a small hole in either side and under tabs on the back inside the box Quick note: unlike the gas pedal in a car that will give the engine more fuel and go faster, the thermostat is only an on off switch. If you turn to 7 it will not get the box colder faster than if you turn to 1, it will keep it running longer and get the box colder over time.

Connecting the refrigerant lines to the condensing unit. After you have run the line kit from your cold plates to the condensing unit, remove the plastic caps that protect the couplings. Put a drop of oil on the thread of the male couplings. Connect the couplings from the unit to the couplings of the line set. With your fingers tighten the couplings until you can not thread any further. This should be about 4 rotations. At this point connect two wrenches to the couplings to make them tight. Quick Note: Failure to use two wrenches could cause the copper to twist and leak. Electrical: The DC models are 12 & 24 VDC. The unit will run on 12 vdc setting until the voltage reaches 17 volts. 17-21 volts is the dead band where it determines if you are running it on 12 or 24 vdc. Quick note: The condenser fan which is wired to the electronic control is always a 12 vdc fan, even when you are supplying 24 vdc. DC breaker & fuse sizing 20-amp breaker (main switch) for both 12 & 24 VDC applications. Both the fuse and the breaker are to protect the power source and should be installed near the power source. 15 Amp fuse for 12VDC 7.5 Amp fuse for 24VDC Breakers and fuses are not supplied with the LT unit

DC Wire Sizing: Ensuring the correct wire sizing will eliminate premature shut down due to low DC voltage at the refrigerator. Please follow these guidelines. Nova Kool product is designed to stop running at 10.4 vdc and cut back in at 11.7 vdc, to protect your batteries. Size Max length Max length AWG 12 vdc 24 vdc Gauge mm ft. m ft. m 14 2.5 8 2.5 16 5 12 4 13 4 26 8 10 6 20 6 40 12 8 10 32 10 65 20 The Max length is from the fridge to the battery. In some cases you may like to lower the voltage the unit cuts out on for battery protection. This can be done by placing a jumper wire between the P and the C terminal on your electronic control board. By doing this you will set the control unit to cut out at 9.6 vdc and cut in at 10.9 vdc. We supply a red jumper pre connected on the thermostat wire for convenience. By connecting it to the P on the control module it will allow the unit to run to the lowest voltage before it cuts out on low voltage. (see wiring diagram) 4. Compressor Speed: All Nova Kool units are supplied with the silent and efficient variable speed compressors. Nova Kool has supplied your unit preset at the optimum speed for most normal applications. The speed is controlled by a resistor in the thermostat circuit. 0 ohms (no resistor) runs the compressor on its slowest speed, a 1523 ohm resistor will provide you with the fastest speed. The slower the speed, the lower the amp draw, and the lower the capacity. The chart provides four examples; the resistance must be between 0 ohms and 1523ohms. Resistor Motor Approximate Ohms Speed running rpm current 0 2,000 2.3 2.8amps 277 2,500 3.2 3.7 amps 692 3,000 4.2 4.9 amps 1523 3,500 5.0-6.5 amps

In our testing we have found if you run the unit at a lower speed and amperage for a longer period, your total amperage consumed will be less than if you run the unit at a higher speed and amperage for a shorter period. Every time the unit starts up it draws a higher start up current and it also needs 15 30 seconds of run time to start to do actual cooling. Longer run times at lower amperage, usually improves efficiency and lowers power consumption. Think about it as a car. The speed limit is 50, the small car get to the destination the same time as the big car, but the small car does it with less fuel consumption. Quick note: We have included a black 500ohm resistor for medium speed and a red 1500 ohm resistor for high speed compressor operation. For low speed just connect the thermostat wire to C and T without the resistor. The resistors we supply are not to be used together in series. Choose one or the other or do not use one for low speed. We have supplied you with a quality unit. If for some reason you would like to call us for support please do. Before you call consider that, the three main reasons for problems in the field are: Lack of ventilation Power problems, often related to wire sizing or connectors. Battery voltage, capacity or age.

Wiring diagram After serial number 256409 the thermostat wire has an additional red wire which is used to control cut out voltage. If it is placed on P the cut out voltage is 9.4 vdc. If it is simply left off of terminal P the cut out voltage is 10.6 vdc Optional AC DC control module

Trouble Shooting Check DC operation first then check AC/DC starting at #19 YES NO 1 2 Turn DC power on and turn thermostat to "7" position Is the compressor running? (Put your hand on top to feel slight vibration to be sure). #2 #16 #3 3 4 5 6 7 8 9 DC Breaker is in the "on" position & optional fuse is good? Replace fuse or turn breaker "on". Does optional fuse or breaker blow? Check voltage at the refrigerator "+" & "-" terminals on the black module. Is it over 12.2 vdc? (or 24.5vdc where applicable) Check batteries, wiring and connections to the refrigerator for fault, corrosion, proper wire sizing and correct the problem. Put a jumper wire between terminals "C" & "T". Is the compressor running now? Disconnect small black wire from the fan that goes into the F terminal. Is the compressor running now? Disconnect power. Remove electronic module (Philips screw beside terminal designation label will require removal). Disconnect the plug. Measure resistance (ohms) between each of the three compressor terminal pins. Is the measured resistance APPROXIMATELY the same?(it should be) 10 Replace Electronic Module. Have compressor replaced by qualified appliance technician who has the ability to evacuate and 11 recharge the system. This is seldom necessary so please be sure and if possible contact Nova Kool for further instruction beforehand. Check wiring to thermostat with ohm meter to 12 ensure there is continuity. (No broken or damaged wires or connectors). Is the wiring & Yes #5 #6 #7 #1 #12 #15 #10 #1 #14 No #4 #5 #6 #8 #9 #11 #13

speed resistor (if so equipped) okay? Disconnect power. Repair or replace wiring or 13 speed resistor (if so equipped) as necessary 14 Replace thermostat. 15 Replace Fan Have refrigerator in a well ventilated area (i.e. on 16 cabin floor). After an hour is it refrigerating? Check that adequate ventilation has been provided. 60 sq. in. for single door models and 17 120 sq. in. for 2-door models. See ventilation suggestion in this manual. Add ventilation as required. Have a qualified appliance technician determine if 18 there is a refrigerant leak or a compressor with a mechanical problem. #1 #1 #1 #17 #18 Switch DC breaker off and AC breaker on. Does 19 the compressor run? Is there 110VAC or 220VAC available the AC plug 20 on vessel? Check Power on the L & N terminal on the 21 electronic module (see AC/DC wiring diagram in this manual) is there 110vac or 220vac available? Check 4 amp fuse on power plug on refrigerator 22 (see picture), is it good? 23 Replace fuse 4 amp. Did it blow again? Check wiring to L & N module, Is wire 24 damaged or shorted out? Check plug, wiring, breaker, shore power or 25 genset for damage or fault. Repair or replace as required. Repair short or damage between plug & electronic 26 module then #21 Yes #16 #21 #7 #20 #24 #26 #19 No #20 #25 #22 #23 #21 #10

Defrost & Cleaning: The frequency of defrost is dependant on the number of door openings, the ambient temperature and the humidity level. Typically, it is a good practice to defrost once there is ¼ of frost buildup on either side of the evaporator (cold plate). When defrosting, the unit is shut off at either the breaker panel or by turning the thermostat counterclockwise to the OFF (0) position. Prop the door open. We suggest placing a towel in the bottom of the refrigerator to catch excess moisture. Speeding up the process with a knife or scraper is strongly discouraged due to the likelihood of rupturing the refrigerant circuit; in the event this happens give us a call 604-523-6515 ext.104. Now that the unit has been defrosted, the interior can be cleaned with a non-abrasive cleaner. Do not use brilo or sos type abrasive pads, as they will score the surfaces. Baking soda is recommended. If you are turning off the unit for some time it is best to clean it first, and then leave the door open a small amount to allow the air to move freely in and out of the refrigerator. Do not leave the door closed while the refrigerator is not in use. Mold and odor will build up on the inside of the refrigerator without air movement. Two-Year Limited Warranty This refrigeration unit is warranted to be free from manufacturer s defects in both material and workmanship providing that the unit is used in a manner consistent with the intentions of Nova Kool.

The warranty is in effect from the final sale to the end-user (whether installed in a vehicle or sold separately) for a period of two years. Nova Kool will supply the required replacement part or parts at no charge. This warranty does not cover problems out of the control of Nova Kool Mfg. inc. including but not limited to acts of God, acts of Government or misuse. Before calling for warranty please review the troubleshooting in this guide and have your serial # and model # ready. Our service department can be reached at 604-523-6515 ext 104, or at support@novakool.com from 7:00 am to 4:00 pm PST.