MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION

Similar documents
HEAT RECOVERY AIR HANDLING UNIT

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

VETO CLEANER 500 FLUE GAS CLEANER

Whole Room Dryer WRD, WRD/110

OPERATING AND INSTALLATION MANUAL

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Light oil / kerosene burner

4. The above safety devices should be electrically connected to the `startconditions' circuit of the burner.

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

DOUBLE PLATE INDUCTION COOKER. Model A 2006 (S2-L2)

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

ICS Praha MTP GAS-FIRED AIR HEATERS

USER S INFORMATION MANUAL

WHE 2.24 / WHE 2.24 FF

ATM Lighting sp. z o.o

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

Wind. Service instruction

INSTALLATION AND OPERATION MANUAL

Incinerator Model A1600 -Oil

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

DH-Direct Fired Poultry Farm Diesel Heater

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

TTV 4500 / TTV 4500 HP / TTV 7000

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

Turbo. Service Instructions

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

AXIAL FANS USER S MANUAL

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

IMPORTANT SAFETY INFORMATION

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Fire-Water Bowls Model 100

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

ATM Lighting sp. z o.o

Columbia Boiler Company

BENSON LINEAR RADIANT TUBE

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

VERSAFLOW VORTEX Supplementary instructions

Wax Base Heater & Dispenser

Installation Instructions Remote Blowers

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

ecomax 200 W Boiler regulator FOR SOLID FUEL BOILERS WITH A FAN OPERATION AND MAINTENANCE MANUAL ISSUE:

Centrifugal inline fans

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

CENTRIFUGAL FANS user's manual. model VENTS VK.

Bagless upright vacuum

SOLID FUEL HEATING UNIT TYPES NPS 35 AND NPS 70 ORIGINAL INSTRUCTION MANUAL

Power 4. User Guide. HC85-P4-ZA hoover.za.com

OPERATOR S MANUAL. For BURLY ATTACHMENTS

GRAND EFFECTS Fire-Water Bowls Model 100

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

WARNING FIRE OR EXPLOSION HAZARD.

USER S INFORMATION MANUAL

Installation and Operating Manual Drying Cabinet

FOR EASY, FAST INSTALLATION AND FOR RESULTS

CENTRIFUGAL CEILING EXTRACT FAN

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

Assembly instructions for Minib convectors

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

DUST EXTRACTOR MODEL No: CDE1000

Original instructions. Operation Manual & Cautions

Installation manual Mini Comfort 50 S/L 07/ V EN

Rapid Response Series (RR e & RR i) OPERATING MANUAL

1. The structure and its description

PANTHER P Automatic Boiler Operator's Manual

ML180UH SERIES GAS FURNACE WARNING WARNING

OPERATING INSTRUCTIONS with safety features

Grinding mill MISTRAL 50L (art. 650P)

Industrial Vacuums, Inc

PER-EKO type KSW & KSW PLUS Instruction Manual

ENAMELED INDIRECT WATER HEATERS

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

Technical certificate, instruction for installation and use. Sauna heater VIENYBĖ- P K6M ĮST :2003 ГОСТ

OPERATING AND INSTALLATION MANUAL

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

INSTALLATION COMMISSIONING MAINTENANCE

CANOPY RANGEHOOD. instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY

HEAT RECOVERY VENTILATOR

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

USER'S MANUAL PS

40E ELECTRIC FAN HEATER

Lo-Carbon SELV Tempra

en Direct oil-fired space heaters HD... Operator's manual

Transcription:

Do Žlábku 733, 514 01 Jilemnice Subject: MTP (MTPAL) Technical Documentation Page 1 of 13 MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION Table of Contents: Page: 2 Warranty Certificate 3 Quality and Completeness Certificate (Product Test Sheet) 4 Technical Conditions 9 Assembly, Operating and Maintenance Instructions 13 List of Accessories and Spare Parts 13 List of Certified Repair Centres Annex No.: 1 Certificate No. E - 00663-02-rev.1 (gaseous fuels) or No. B-30-00664-02 (liquid fuels) SZU Brno 2 Declaration of Conformity 3 Wiring Diagram 4 ESD3J Thermostat User Manual 5 MTP (MTPAL) Air Heaters Technical Data and Dimensions 6 MTP (MTPAL) Air Heaters Loading and Transportation Instructions Approved by: Date: July 1, 2006

Subject: MTP (MTPAL) Technical Documentation Page 2 of 13 Warranty Certificate The Manufacturer shall be liable for any defects of the Product which undisputedly occurred during the Warranty Period as a result of defective design and/or manufacture. The Manufacturer shall not be held liable for any defects if: - the Product is changed or amended in any way by the Purchaser or any party working on his behalf; - the seals affixed on the Product are broken; - the Product is damaged by applying too much force; - the Product and any part thereof is not set up and/or connected according to the Manufacturer s instructions; - the Product is situated in an environment not recommended by the Manufacturer in the relevant documents; and - the Purchaser does not follow the Technical Conditions provided by the Manufacturer. Warranty Period: Provided the conditions set forth herein (i.e. the Manufacturer s instructions and recommendations) are met, the Product shall have a Warranty Period of twenty four (24) months, commencing on the day of delivery of the Product. As another Warranty Condition, the Manufacturer hereby expressly reserves the right to appoint a person to be present, at the expense of the Purchaser, during the start of operation of the Product at the Purchaser s premises. Product: Type: AIR HEATER MTPAL Serial Number: Date of Delivery of the Product (as affirmed by the Seller): Go-Live Date (as affirmed by the Supplier): This Warranty Certificate is to be produced by the Purchaser with any claim; it has to be supported by the Go-Live Certificate, duly validated by the person appointed for this purpose by the Manufacturer, and the Burner Setup Certificate. This Warranty Certificate is void unless produced together with the Go-Live Certificate!

Subject: MTP (MTPAL) Technical Documentation Page 3 of 13 Quality and Completeness Certificate (Product Test Sheet) The Manufacturer hereby attests and confirms that the Product specified hereinafter meets the requirements of the applicable testing regulations, i.e.... Product: AIR HEATER Type: MTPAL Serial Number:... Basic Technical Data Nominal Heat Input:... kw Nominal Heat Output:... kw Nominal Airflow:... m 3 /h External Air Pressure:... Pa Nominal Electric Input:... kw Weight:... kg IP Degree of Protection IP Voltage: 3 x 400 V + N + PE 50 Hz Electric Engine Used:... V-Belt:... Date: OTK: Ing. Václav Šubrta Manufacturing Director

Subject: MTP (MTPAL) Technical Documentation Page 4 of 13 TECHNICAL CONDITIONS MTP (MTPAL) AIR HEATER

Subject: MTP (MTPAL) Technical Documentation Page 5 of 13 1. Validity These Technical Conditions cover the functional, design, testing and delivery requirements of standard air heaters. Applying to horizontal and vertical heaters intended for indoor and outdoor use, these Conditions are valid until declared invalid or replaced by a newer version. 2. Usage Irrespective of the heater and fuel used (natural gas, coal gas, propane butane, fuel oil or light heating oils), air heaters are intended for: a) heating of closed spaces b) technological heating c) ventilation (using non-heated fresh air) 3. MTP (MTPAL) Function Description Having separate air-conditioning and combustion circuits, the heater draws, via a fan, air from the environment (floor) or a dedicated air duct. By drawing air from its environment, the heater also improves local sanitary conditions. Flowing around the combustion chamber, the air is heated and subsequently runs to the outlet section. Burners are selected according to the fuel to be used. Combustion products are conducted away through a duct attached to the waste outlet of the combustion chamber. The burner and the waste-gas flue are not supplied by the Manufacturer. 4. Type Identifiers Heaters have a specific type identifier with the following meaning: Air Heater MTP (MTPAL) 25 Type Size (see Art.10) 5. Structural Description The main casing of the heater consists of a frame made of individual sections allowing easy coverage of the heater. Made of welded sheet metal, the combustion chamber is fixed to the heater with bolts. Heater covers are equipped with internal heat insulation and shutters enabling air to be drawn in. Below the combustion chamber, there is a fan with an electric motor. The motor is fixed to the frame and fan to allow a V-belt to be stretched between the pulleys of the motor and fan. The area of the motor and fan is covered by shutters allowing heated air to be drawn in. To keep the air clean, there are filters installed in this section. The burner is fixed on the front side of the heater, allowing fuel to be burned in the combustion chamber. Combustion products are discharged through the waste outlet, typically situated on the rear side of the heater, and conducted away through a duct attached to the waste outlet. The heater is equipped with an electric control unit with switching, control and safety circuits to enable fully automatic heating. Typically, the control unit is installed on the front or lateral side of the heater, according to the customer s wish; however, the unit can also be installed as a stand-alone control (i.e. not fixed to the heater). In the latter case, the control unit still forms an integral part of the heater and is supplied separately (installation and connection to be done by the customer).

Subject: MTP (MTPAL) Technical Documentation Page 6 of 13 The heater is further equipped with a system draining combustion condensate from the combustion chamber (a 1/2" pipe). The heater also includes a triple thermostat to ensure smooth and safe operation (switches the fan on and off and limits the maximum temperature of the heater) 6. Operating Conditions Smooth and safe operation can be guaranteed only on the following conditions: a) All parameters set forth by the manufacturer have to be observed, in particular: - nominal heat input ( kw ); - nominal airflow ( m 3 /hour ); - air temperature ( for typical systems not more than 40 C ); b) Working environment In terms of working environment, there are two main heater types: indoor heaters and outdoor heaters. - Indoor systems equipped with IP 40 protection degree can be used in standard / basic environments. - Outdoor systems with IP 43 protection degree are intended for outdoor use; here, the burner and thermostat are equipped with special shields protecting them from atmospheric precipitations. - Be sure to prevent outdoor systems from sucking in larger objects (such as tree leaves). c) Combustibles must not be stored in the vicinity of the heater fire hazard!!! 7. Noise Level As reported by SZU Brno, the mean value measured in the vicinity of a MTP 65 heater was Ldl = 74,2 db (A), thus not reaching the maximum allowed limit of 85 db (A). 8. Engineering Supervision and Inspection During manufacture, the Manufacturer is responsible for engineering supervision and inspection and its acceptance. Besides, the Manufacturer has reserved the right to appoint a person to be present during the start of operation of the heater. Subsequent supervision is carried out by Strojírenský zkušební ústav Brno (SZU Brno) according to EC Directive No. 2009/142/EC (as transposed into Czech national law in government regulation No. 22/2003 Coll.), Annex II.2, Art. 2.3. Supervision takes place in the form of random inspections of the heaters according to the EC Certificate. 9. Documentation Every product is supplied with a set of documents required for its smooth and safe operation (i.e. this technical documentation).

Subject: MTP (MTPAL) Technical Documentation Page 7 of 13 10. Technical Parameters of the Heaters Type / Model Heat Output Max Heat (kw) Output (kw) MTP 25 29 MTPAL 50 MTP 37 45 50 MTP 50 60 MTPAL 80 MTP 65 75 80 MTP 85 100 MTPAL 150 MTP 100 120 140 MTP 125 150 MTPAL 200 MTP 150 175 200 MTP 175 200 MTPAL 300 MTP 225 260 275 MTP 300 350 MTP 350 MTPAL 500 400 460 MTP 400 465 MTP 525 MTPAL 700 600 700 MTP 650 MTPAL 900 750 900 MTP 850 990 MTP 1000 1,160 Note: MTPAL...commercial branding Loss due to thermal transmission 2.0 % Loss due to combustion products heat 10.9 % For more information consult the Quality and Completeness Certificate (page 3). 11. Materials and Surfacing The materials and surface treatment used ensure required durability and adaptability in working environments according to Article 6 hereof. In terms of interference and the prevention thereof, the heater meets all applicable standards. 12. Labelling Every heater bears a non-removable label with the following information: a) Manufacturer b) Product ID c) Type identifier d) Serial number e) Year of manufacture f) Nominal heat input (kw) g) Nominal heat output (kw) h) Nominal airflow (m 3 /h) i) External air pressure (Pa) j) Nominal electric input (kw) k) Weight (kg) l) Voltage ( 3 x 400 V + N + PE 50Hz ) m) IE degree of protection n) Intended country

Subject: MTP (MTPAL) Technical Documentation Page 8 of 13 Furthermore, there is a label on all exchanger parts with the following text: This heater has to be installed according to the instructions of the Manufacturer and can be used in well ventilated areas only. Read instructions before installation and use! 13. Tests Type Tests Type tests are performed by: Strojírenský zkušební ústav Brno s.p., zkušebna 202, Hudcova 56b, 621 00 Brno, the Czech Republic. Production Tests Production tests of every exchanger part are performed by the manufacturer in his production plant: JINOVA s.r.o., Do Žlábku 733, Jilemnice, the Czech Republic. Production tests comprise of the following tests and inspections: - weld tests of the casing - weld tests of the exchanger - inspection of external interface dimensions - surfacing inspection - inspection of the device and its accessories in terms of completeness - wiring inspection - impressed voltage test - insulation inspection - function tests For further information consult the Product Test Sheet. 14. Packaging, Transportation and Storage - If requested by the customer, supplied heaters are wrapped in fixation foil to reduce possible surface damage and mounted on wooden bases or pallets. - All persons taking part in the transportation and loading of the heaters are advised to proceed with caution. Handling allowed only by means of the pallet, lower frame (between the wooden bases) or welded loops. Where there are two loops, both have to be used; in such cases, using one loop only is strictly prohibited! Packages must not be subjected to atmospheric exposure, continuous humidity and shocks. - Heaters have to be stored in well ventilated rooms with no corrosive vapours or active gases, or outdoors under a shelter protecting the heater from any atmospheric precipitations.

Subject: MTP (MTPAL) Technical Documentation Page 9 of 13 ASSEMBLY INSTRUCTIONS Handling The heater will be delivered freely or, at the customer s request, on a wooden pallet wrapped in a fixation foil. While unloading, in particular using a forklift, the heater has to stand on the palette by all means. The fork of the forklift used has to be long enough to lead under the whole palette. Using short forks will inevitably result in damage to the heater. It is also possible to use a crane to unload the heater. In such a case, the heater includes one or two (depending on heater type) loops (at the tube plate of the combustion chamber) or handling holes in the under-frame (handling using bars). If there are two loops on the device, both have to be used; in such cases, using one loop only is strictly prohibited!!! Positioning! The heater has to be positioned on a level and sufficiently solid ground or frame. In order to allow condensed fluids to flow off, the heater has to be positioned horizontally (minor downward grade helping the outflow is acceptable). The heater has to be positioned in a way to allow the combustion chamber to be replaced and the tube zone to be cleaned. In other words, there has to be a free space in front of the front (burner) side of the heater at least equal to its size ( length x width x height ). The cover of the tube plate of the exchanger chamber (opposite the chimney) has to be kept free to allow easy removal when cleaning the tube plate.! The heater has to be positioned in a way allowing the V-belts to be put in place and/or removed (upon removing the covers) and the tube plate to be cleaned.! Outdoor heaters installed on a roof have to be equipped with a lightning rod. Safe Distances True distance between the heater and any combustible material must comply with all applicable standards, i.e. must not be smaller than 200 mm. If it is not possible to meet this condition, a protective screen has to be used. The screen has to be at least 3 mm thick and made of a material of flammability class A or B. The screen has to be in a fixed position between the heater and the protected substance, 30 mm (±5 mm) from the protected material. The screen has to stretch to the nearest wall (ceiling) made of a non-combustible material, but at least 300 mm beyond the upper and 150 mm beyond the lateral edges of the protected material. When a protective screen is used, the minimum distance allowed can be halved. When installing a gas heater on a floor made of a combustible material, a non-conducting insulation pad has to be used. The pad has to be resistant to mechanical load and made of a

Subject: MTP (MTPAL) Technical Documentation Page 10 of 13 material of flammability class A or B. In terms of ground plan, the pad must not be smaller than the heater; moreover, it has to be at least 5 mm thick.! Do not store combustibles in the vicinity of the heater possible fire hazard! Objects which can hinder air circulation must not be placed closer than 1 m to the heater. Connection to Air Ducts In stand-alone operation (i.e. not connected to air ducts), the air distributor in the outlet section is attached directly to the frame of the heater. The distributor is bolted to the heater and then, typically, it is fitted with double-row diffusers (supplied with the distributor). When connecting the heater to intake or outlet air ducts, the initial duct sections can be bolted directly to the frame; alternatively, a silent-block can be used. Connection to Smoke Flue The smoke flue has to be installed by a specialised company and according to all applicable regulations. Note: Every heater equipped with a high-pressure gas boiler has to be connected with a separate smoke flue to a separate vent stack. If the heater includes a condensed fluid receptacle (20 30 l), it is intended both for combustion chamber condensate (1/2" discharge pipe) and chimney-bottom condensate.! Note: Irrespective of their type, the operation of any MTP heater requires proper drainage of flue-gas condensate. Installing the Burner Typically, heaters are fitted with pressure burners (single-stage, double-stage or smooth fuel input regulation). Burners are not a part of the heater delivery. Fuel intake has to be installed by a specialised company and has to meet all applicable regulations according to the fuel and/or burner type used. The installation and setup of the burner has to be done by an engineer appointed by the manufacturer of the burner. After the burner has been duly inspected and set up, a setup certificate is issued; at this point, the heater is ready for final inspection and to go live. As already given herein, the manufacturer of the heater reserves the right to have one of his engineers present during the go-live procedure at the expense of the purchaser. Not meeting the following requirement may result in the warranty becoming void. Typically, heaters are fitted with flanges and seals into which the burner is mounted using bolts. In outdoor heaters, an appropriate cover has to be fitted above the burner. Before installation always check the compatibility of local conditions relevant for the operation of the heater, i.e. fuel intake, fuel properties, fuel pressure and heater setup.

Subject: MTP (MTPAL) Technical Documentation Page 11 of 13 Wiring All electrical services have to be rendered by professionals. After the services have been completed, a thorough inspection is required. When connecting the ESD3J thermostat, Weishaupt burner and measurement and control circuits, follow the recommended wiring diagram attached hereto (drawing No. 3-JH-2001C)! After connecting the fan, be sure to check the direction of its rotation! The heater is equipped with an earthing connector.! Under any circumstances, the clamp of the triple thermostat has to be connected to the PE conductor in order to make sure that the thermostat sensor is not influenced by possible induced voltage. OPERATING INSTRUCTIONS When installing and operating heaters burning natural gas, coal gas, propane butane, fuel oil or light heating oils, the following rules have to be observed. Every heater has in its outlet section a triple thermostat ensuring smooth and safe operation. This thermostat is not intended for controlling required temperature. T1 Safety Thermostat shuts down the burner by cutting off its power supply. After a safety shutdown, the burner cannot be engaged again automatically unless a specific button has been pressed on the thermostat first. Before the thermostat can be unblocked again, the temperature at the T1 thermostat has to drop below the specified threshold. Before enabling the heater again, be sure to find out and remedy the cause of the overheat. The thermostat used allows the T1 safety thermostat to be reset remotely (e.g. by means of a control panel button), this can be helpful in case of poorly accessible exchanger sections (e.g. suspended sections). When power supply is cut off while the burner is engaged, temperature will increase because the fan cannot draw away the heat accumulating in the exchanger chamber. After the temperature exceeds the preset threshold, T1 will cut off the power supply of the burner, thus disengaging it. Once power supply is restored, the thermostat will be reset automatically, provided that the temperature measured here dropped below the set threshold in the meanwhile. In case of short power failures (i.e. when the temperature still exceeds the limit when power supply is restored), it is necessary to wait for the chamber to cool down; subsequently, the thermostat can be reset manually by pressing the appropriate button. T2 Operational Thermostat turns the burner off after the temperature exceeds the relevant threshold and turns it on when it drops again. T3 Fan Thermostat turns on the fan once the temperature exceeds the relevant threshold and switches the fan on to cool down the chamber after the burner has been shut down.

Subject: MTP (MTPAL) Technical Documentation Page 12 of 13! Attention The main switch can be turned off only after the fan stops completely. When not using the heater for a longer period of time, be sure to shut off fuel intake. Once properly set up and commissioned by professionals, the device and its parameters cannot be altered in order to ensure smooth and safe operation. For maximum safety, it is recommended to have the heater checked at least once in a year by the manufacturer or an approved service centre! MAINTENANCE INSTRUCTIONS The heater has to be maintained after every scheduled shut-down. Maintenance and all related actions have to take place in accordance with the instructions set forth herein. Maintenance Works:! a) Inspect the tension of the V-belt and its wear and tear (as needed).! b) Check whether the bolts of the burner plate and tube plate lid are tight; first check to take place after one month of operation, subsequent checks before every heating period.! c) Perform regular checks of intake filters (at least once a month); if needed, clean or replace filter fabric. The speed of filter clogging depends on the purity of suction air. Any dirt substantially decreases the volume of air supplied by the heater, thus increasing exchanger chamber temperature.! d) Have the burner checked and set up by a certified engineer at least once in a year (preferably before the start of the heating season). Burner setup is possible only while the heater is operational. e) Clean the tube plate at least once in a year (or as needed). In case of fuel oil and light heating oils, clean the tube plate every time there is a decrease in heating efficacy (as needed, possibly even once a month). Once cleaning is finished, be sure to tighten the bolts of the tube plate lid properly and, if needed, replace washers. (Check tightness again after a month of operation!) Defects a) Electric defects have to be remedied according to the wiring diagram supplied with every heater. b) Overheating - make sure that intake and outlet areas are not clogged (ducts, etc...) - check filtration fabric and filter

Subject: MTP (MTPAL) Technical Documentation Page 13 of 13 - if filters appear to be in good condition, consult the defect with the manufacturer. c) Combustion products detected in heated area or increased oxygen content discovered in combustion products - make sure that the bolts of the tube plate lid and burner flange are tight. - change the washers in the tube plate lid and/or burner flange. - make sure there is no hole in the combustion chamber. LIST OF ACCESSORIES AND SPARE PARTS Accessories supplied with the heater have to be ordered separately. - filtration frame - belts - filter The above accessories can be ordered at any time at the manufacturer s plant. No spare parts are supplied with the heater. Spare parts for warranty repairs are available at the manufacturing plant; all warranty repairs (except for burner defects) can be performed by the manufacturer s engineers. Post-warranty repairs take place at the customer s expense. The required spare parts can be obtained from the manufacturer. The warranty period does not apply to V-belts (their type and size is specified in the Quality and Completeness Certificate) and filtering fabrics. LIST OF CERTIFIED REPAIR CENTRES Warranty and post-warranty repair services of MTP heaters are provided by the manufacturer: JINOVA s.r.o., Do Žlábku 733, 514 01 Jilemnice, the Czech Republic tel.: +420 481 541 518, +420 481 549 351, fax.: +420 481 544 184, +420 481 543 163