Filtrex A Smoke Detector for Difficult Environments

Similar documents
These instructions detail procedures to follow in order to avoid damage to equipment.

TrueAlarm Smoke Detectors

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing

TrueAlarm Analog Sensing

DH200RPL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

TrueAlarm ES Analog Sensing

Addressable Detectors & Bases

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Laser Technology Smoke Detector

A Comparison of Aspirated Smoke Detectors

D350RPL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

Intelligent Signature Series Analog Detection

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Reshaping Duct Smoke Detection

DH100LP Air Duct Smoke Detector with Extended Air Speed Range

LEARNING SPECIAL HAZARD DETECTION TYPES

Installation Manual: PAD100-DUCTR Analog Addressable Duct Detector

INSTALLATION AND MAINTENANCE

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

D350PL INTELLIGENT PHOTOELECTRONIC DUCT SMOKE DETECTOR WITH EXTENDED AIR SPEED RANGE INSTALLATION AND MAINTENANCE INSTRUCTIONS

E-PDD Duct Smoke Detector Installation Sheet

DH500 Intelligent Air Duct Smoke Detector Housing

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Intelligent. Signature Series Multisensor Detection. An EDWARDS brand.

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

EXTINGUISHING SYSTEM DETECTION AND CONTROL

D2E Duct Smoke Detector

DETECTOR TEST LOG. Detector Identification Information DHX-501 INTELLIGENT AIR DUCT SMOKE DETECTOR HOUSING INSTALLATION AND MAINTENANCE INSTRUCTIONS

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

DH500ACDC Intelligent Air Duct Smoke Detector Housing

Reshaping Duct Smoke Detection

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

Multi-Point Peripherals

Multi-Point Peripherals

7251DH Intelligent Air Duct Smoke Detector

PRODUCT OVERVIEW SM-501 AT-A-GLANCE

Smoke Detector Testing

ALK-V PHOTOELECTRIC SMOKE SENSOR

DH100ACDCI Ionization Air Duct Smoke Detector

PRODUCT OVERVIEW. SL-2000 AT-A-GLANCE MODEL NUMBER: SL-2000-N 4-Wire Ionization Duct Smoke Detector SL-2000-P 4-Wire Photoelectric Duct Smoke Detector

DH100ACDCI Ionization Air Duct Smoke Detector

FX-PDD Duct Smoke Detector Installation Sheet

HART XL High Sensitivity Smoke Detection

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

Installation Instructions

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

You in Control PRODUCT OVERVIEW

InstrumentationTools.com

A P P L I C A T I O N S G U I D E. Single-Ended Reflected Beam Smoke Detector

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

Installation Instructions

DH400 Air Duct Smoke Detector

Application Data ! WARNING FACTORY INSTALLED SMOKE DETECTORS FOR SMALL AND MEDIUM ROOFTOP UNITS 2TO25TONS TABLE OF CONTENTS PART NUMBERS

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

SECTION FIRE ALARM SYSTEMS

TRN100BPT, TRN100BP, and TRN100BPC Air Duct Smoke Detector with Extended Air Speed Range

ESL 500N Series Smoke Detector Installation Sheet

Detection and Control Components

ID50series. intelligent fire alarm panels

SK-Duct Air Duct Smoke Detector

FEMA Recommendations for Protection of Curtained Limited Finishing Workstations using UL 1254 Listed Pre engineered Dry Chemical Systems

Residential Fire Protection

Intelligent Earliest Warning Aspirating Fire Detector

SMOKE ALARM SUMMIT Technological Advances in Smoke Alarms Richard Roberts Honeywell Fire Safety Industry Affairs Manager

D343. Installation Instructions. Air Duct Smoke Housing

Wiring Instructions. Single Doors 99 Checkmate Series Use one or Master Unit each door or one or Support unit each door

Great for Rental Stackable: Constructed with interlocking ribs for stacking vertically. Great for storage as they need a minimal footprint

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

Study on Fire Detection at Cultural Assets Buildings with Botanical Roofs

HART XL High Sensitivity Smoke Detection

AlarmLine Addressable Linear Heat Detector

FEMA RECOMMENDATIONS FOR PROTECTION OF CURTAINED LIMITED FINISHING WORKSTATIONS USING UL 1254 LISTED PRE-ENGINEERED DRY CHEMICAL SYSTEMS

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Open-area Smoke Imaging Detection (OSID)

DH100ACDCLPX Air Duct Smoke Detector with Extended Air Speed Range

~500 V AC / DC. Wireless 500 VAC/VDC Voltage Meter. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications

Frequently Asked Smoke Alarm Questions

Miniveyor. Tough Fans for Tough Jobs! NEW VAF Models now come with a Industry Leading 10 Year warranty upgrade on the fan body.

BERMAD Fire Protection

Desigo Fire Safety intelligent detectors for complete safety

Carbon Monoxide Alarms Smoke and Carbon Alarms Upgrade Requirements for Single and Two Family Dwellings

AlarmLine Linear Heat Detector

1400 Direct Wire Ionization Smoke Detector

Smoke Alarm User s Manual

EN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu

Instructions. Duct Mount Accessory Q Rev: 11/

DETECT-A-FIRE Heat Detectors

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Aspirated Smoke Detectors

Intelligent Detection Devices

RMS-I-DE-01 Smoke Detector

Evolution Analogue Addressable Fire System

OH110, OP110, HI110 Automatic fire detectors

D296/D297. Application Guide. Projected Beam Smoke Detectors

The new detector from Rafiki

Transcription:

A P P L I C A T I O N S G U I D E Filtrex A Smoke Detector for Difficult Environments

A P P L I C A T I O N S G U I D E Filtrex A Smoke Detector for Difficult Environments Contents Section 1 Product Overview...2 Section 2 Operating Principles...2 Section 3 Filtrex Proves Itself...3 Section 4 Applications...3 Section 5 Application and Placement Considerations...4 Section 6 Installation Considerations...5 Section 7 Specifications...5 Benefits Filtrex goes to the worst places. Made for some of most difficult interior environments on earth, it holds its own against dust, insects and will even withstand occasional water spray. This specially designed, patented smoke detector filters airborne particulate so it can concentrate on sensing smoke. Filtrex is fast. Its early response time provides early detection well before slower-responding thermal detectors thereby minimizing property loss. It doesn t fool with fire. Filtrex virtually eliminates false alarms minimizing business interruption. Filtrex installs easily into existing analog-intelligent systems. 1

F I L T R E X : A S M O K E D E T E C T O R F O R D I F F I C U L T E N V I R O N M E N T S Section 1 Product Overview The first difficult environment smoke detector It s well known that smoke detectors just don t work in certain places. Dirty, dusty places like paper mills. Lumber mills. Cotton and textile mills. Dry chemical processing plants. Horse stables and other climate controlled animal holding areas. Until now, it was next to impossible to achieve true early warning of smoke in these dusty, dirty environments. No smoke detector could stand up to the punishment of dust. Anyone bold enough to try a photoelectric smoke detector in such a place would report the same experience frequent false alarms or frequent maintenance. Until now, specifiers could only choose between thermal, flame detectors, thermal wire or beam detectors. Some of these alternatives, such as flame detectors, could be effective, but are expensive and maintenance-intensive. Others, such as thermal detectors, could be slow to react and in the fire detection business, too slow can be too late. Although these technologies can save lives, they may not respond early enough to prevent property damage. And prolonged extinguishing by water sprinklers or misters can actually increase property damage. Filtrex entirely changes this picture. Using a high-density filter and air intake system, Filtrex removes airborne matter before it reaches the smoke sensor. Dust, insects, water spray Filtrex shuts them all out. And that frees the sensor to do its job: sense smoke. The results of this technology? Demonstrably superior performance. True early warning. Rapid response without false alarms. Straightforward installation into existing systems. Low maintenance. Filtrex is also fully supervised. Internal circuitry can detect a clogged filter or fan failure. While Filtrex is ideal for some of the most dusty and dirty places on earth, it is not intended for exterior use, nor is it recommended for extremely hot, humid, corrosive, hazardous, intrinsically safe or explosive environments. Section 2 Operating Principles Filtrex removes foreign particulate such as dust and water spray while allowing smoke to arrive at the sensor. Photoelectric smoke detectors provide advanced warning of impending fire without requiring heat to alarm. 2. Smoke Sensor Air and Smoke However, because these smoke detectors work on a lightscattering principle, any particulate that enters the sensing chamber can lead the sensor to believe it is detecting smoke. The result: a possible false alarm. Filtrex is a specially-enclosed intelligent photoelectric smoke detector that provides the ability to operate normally in environments that would otherwise cause false alarms. The sealed enclosure contains two high-density air filters that capture dust and water spray while allowing smoke to pass through to the sensor. A small fan draws-in filtered air samples, cycled on and off to increase its life and reduce current draw. Filtrex draws air (1.) through two high-density filters. One filter is field-cleanable; the other is permanent to protect the sensing chamber. A fan, cycled to increase life expectancy and reduce current draw, pulls the air through the fine filters and past the sensing chamber (2). Air is then exhausted (3.) through the chamber and back out the cover. A standard photo sensor is used as the sensing device. Gaskets provide additional dust protection. Fan Filters 3. Exhaust Cycled Sampling Air is sampled every 35 seconds for five seconds. Air flow is checked every four hours for 15 seconds. Two high density filters remove particulate. Continuous Protection Smoke is detectable while water spray or dust is present. Full Supervision If a filter clogs, the panel is alerted and the device is taken off-line. Power-up is automatic when the dirty filter is replaced. 1. Air, Smoke, Dust or Water Mist 2

S Y S T E M S E N S O R Section 3 Filtrex Proves Itself Smoldering Fire Test In this test, a UL smoldering fire (see UL standard 268 for more details about this fire) was performed in which 10 small pieces of wood were placed on a hot plate. At time zero the hot plate was at room temperature. It was slowly ramped to a temperature of around 500ºF. Smoke began generating around the 20 minute mark. Filtrex, in this test, alarmed about 20 minutes after the first smoke was generated. This particular fire would not generate enough heat to alarm a heat detector until a flame-over condition occurred and sufficient heat was generated. As you can see here, Filtrex may provide an early warning. Detector Signal Time Filtrex responds to smoldering fires while heat detectors may not. Filtrex Alarm Threshold Heat Detector Airborne Dust Test This graph shows the results of two separate trials testing the performance of a standard photoelectric smoke detector against Filtrex in a dusty environment. In each test, the signals from the detectors are monitored while they are exposed to a predetermined amount of dust. In each trial, the standard photoelectric smoke detector reaches the alarm threshold, while Filtrex stays safely below. Maximum Detector Signal Alarm Threshold Filtrex Standard Photoelectric Filtrex Standard Photoelectric Trial 1: 0.12 grams of dust Trial 2: 0.24 grams of dust Section 4 Applications Note to specifiers: check that the specified product temperature and humidity conditions are met. Potential Applications Paper and lumber mills Cotton and textile mills Dry chemical processing plants Duct Installations Food processing plants Packaging areas (corrugated dust) Laundry rooms Wash-down and hose-down areas Animal holding areas (zoos, stables, barns) Motion picture studios Subway tunnels Applications to Avoid Explosive conditions Out-of-range temperature and humidity Hazardous environments Outdoor or marine installations Unheated animal barns 3

F I L T R E X : A S M O K E D E T E C T O R F O R D I F F I C U L T E N V I R O N M E N T S Section 5 Application and Placement Considerations Although Filtrex is designed to withstand very dirty environments, it does have some limitations. During our extensive field site testing, we gained valuable experience on how to best apply the product. Performance feedback indicates that Filtrex provides superior detection in difficult environments, as there have not been any reported false alarms. Here are some factors to consider when evaluating potential applications. Temperature Considerations Importantly, Filtrex is not an outdoor product. Observe temperature range when specifying product. The UL specified temperature range is 32 degrees to 120 degrees F (0 degrees to 49 degrees C) and relative humidity is 10% 93% noncondensing. Water Spray Filtrex has also been designed to withstand periodic contact with water spray directed at the housing. Filtrex filters have a special coating that prevents water from passing through or clogging the filter; water beads on the filter and falls off. A potential application could be a wash-down area where there is periodic over-spray that contacts the detector. There should be adequate time between water contact for the unit to dry. Filtrex has not been designed for continuous water contact nor has it been designed to withstand a forceful direct spray. Also, damage may occur if water is allowed to enter from the back of the base where the power and communication wires enter. Particle size and filter issues The two high-density filters that remove airborne particulate have a pore size of 32 microns. This opening size has been carefully chosen through extensive testing to balance between keeping dirt particles out while still allowing adequate smoke entry. So, depending on the particular environment, there is a possibility that a small amount of particles will enter the chamber. In this case, you may experience a low level detector response (analog output from Filtrex shows an increase in signal). But, this increase tends to be well below alarm threshold and, compared to an open area smoke detector in the same environment, is drastically lower. Tests also show that over time, the particles do not tend to build-up, but rather are exhausted from the chamber. With the majority of industrial conditions, there should not be an issue, but consideration should be given to the expected particle size distribution of the dust or dirt found in a given environment. The rate of filter clogging on Filtrex will vary for each individual application. Factors include density, size and structure (fiber, spherical, etc.) of the particles, duration and frequency of high dust conditions, and "stickiness" of the particles (will they adhere to the filter or lay on the surface). We have seen conditions where the filter could last for several years and conditions where filter life was much shorter.* Again, each application will be different and thus, will have varying filter life. If the filter does clog, simply remove the cover/filter assembly and replace with a new one (replacement cover/filters are available). Note: As airflow is reduced due to clogging, Filtrex cuts power and causes a trouble signal at the fire alarm control panel. *Interestingly, we found that in some especially tough areas, changing the filter even on a monthly basis is not too high a price for some customers to pay for detection they have never been able to get before. Placement For placement and spacing purposes, Filtrex is a spot type smoke detector. NFPA 72 guidelines for open area smoke detectors should be observed. A few other common sense rules will allow the product to work as specified: Do not install Filtrex at steam outlets. Steam particles are very small and may pass through the filters, causing false alarms. To extend filter life, do not install Filtrex in the direct path of extreme amounts of dust. Although false alarms should not be a problem, carefully placing units can add substantial life to filters. After a fire Filters should always be replaced after any fire condition to ensure that proper airflow is maintained. Smoke from actual fires will have a tendency to stick to the filters and reduce airflow. Applications Support Call your fire system supplier or System Sensor with any questions. 4

S Y S T E M S E N S O R Section 6 Installation Considerations Installation of the Filtrex system is essentially the same as installing standard intelligent photoelectric smoke detectors, although the mounting base is modified for additional electrical connections. Remote Annunciator RA400Z + 1(+) 2( ) 3(RA) 4(S) AUX AUX+ 1(+) 2( ) 3(RA) 4(S) AUX AUX+ + + Control Panel Auxiliary Power Supply Section 7 Specifications Filtrex Smoke Detector for Difficult Environments Size 3.5 in. (8.9 cm) H x 4.0 in. (10.2 cm) dia. Weight 7.3 oz. (207 g) Detector Input Voltage 15 32 VDC Detector Current Draw 250 µa max. @ 24 VDC (without communication) 360 µa max. @ 24 VDC (one communication every 5 sec. with LED enabled) Auxiliary Power Supply Input Voltage 15 30 VDC (filtered) Auxiliary Power Supply Current Draw Average current: 27 ma max. Peak current: 123 ma max. Operating Temperature Range 0 to 49 C (32 to 120 F) Relative Humidity 10% 93% noncondensing Rated Air Velocity 0 4000 ft./min. (0 20.3 m/s) Distribuição: Segurança Industrial Equipamentos Fone/Fax: (41) 4063-9687 ou 3287-1364 cml@segind.com.br - segindbr@hotmail.com5 www.segind.com.br