B -MG0 i gle G Detecti A rm Ma a nstructio. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Similar documents
BST-MG01 Single Gas Detecting Alarm Manual Instruction

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

Ml ['l>l'ol]

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

IMR IX176 Portable Gas Detector User Manual

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

E1000 Portable gas detector

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

IMR EX610. Portable Gas Detector. Operation Manual

Monitores Personales. Personal Monitor

Dräger Pac 7000 Single-Gas Detection Device

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

OLC(T) 100 FIXED GAS DETECTOR

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

ALTAIR 5X Multigas Detector Product Specification

3M Oldham OLCT 100. Description. Fixed Gas Detector

SC-01 Operator s Manual

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

portable gas analyser

Model Series 700. detcon. Environmentally Bulletproof Gas Detection Sensors. Multi-Layer Surge Protection Water-Proof Corrosion-Proof

EL-USB-1-LCD Temperature Data Logger with LCD

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

PROTÉGÉ ZM SINGLE GAS MONITOR

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

03 Series: OX-03, CO-03, HS-03 Versions Operator s Manual

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

QD6310. Fixed Gas Detector Operation Manual

Micro III (Models G203, G203S, and G213) Operation Manual

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

T.ex Single Gas Detector VISA

GAS DETECTOR ST400EC PART.NO

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Two-Channel Gas Controller

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

DETCON MODEL SERIES 700 GAS DETECTORS

MICRO III (G202 / G202s / G212) Single Gas Detector

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

For the Safety of Your

EST User Manual. (Please read this manual carefully before using)

Gas Detection. Honeywell BW Solo. The next generation in portable single gas detection.

ALTAIR 5X Multigas Detector

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

Operate the Mutli-Gas Monitor PID

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Instruction Manual Model GX-86 Portable Four Gas Monitor

RK-02 Multi Point Detector Operator s Manual

CMF, CMX & CMA series

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Dräger X-am 2500 Multi-Gas Detection

Dräger Pac 3500 Single-Gas Detection Device

PointGard II. Operating Manual

incontrol Systems Inc. Flame and Gas Detection

Safe Operation Manual. Honeywell IQ Force Gas Detector

Stand Alone DYNAGARD SP Operation Manual

1.1 Definitions of alert icons. For your safety

GX-2009 MSHA Certified Version CH 4 /O 2 /CO/H 2 S Portable Gas Monitor Operator s Manual

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

ALTAIR 5X Multigas Detector

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

IT S WHAT S INSIDE THAT

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

GX-2009 Portable Gas Monitor Operator s Manual

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

TC100N. Fixed Gas Detector Operation Manual

Micro IV Operation Manual

GasAlertMicroClip X3 Specifications

Dräger Pac 5500 Single-Gas Detection Device

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

CO warning instruments and gas spillage detectors

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Instruction Manual Model GX-82 Portable Three Gas Monitor

G460. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Bw Gas Alert Clip 2 H2s Extreme User Manual

GasAlert. Introduction. WWarning. Table 1. GasAlert Models. Gas Monitored

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Carbon Monoxide (CO) Gas Detector, 4-20mA or 2-10Vdc

GX-2009 Portable Gas Monitor Operator s Manual

Gas Detection division of Arjay Engineering. Gas Detection Maintenance Facilities Parking Garages Warehouses. EN-GD-11a

Dräger X-am 5000 Multi-Gas Detection

Technical Specifications and User Guide for the GDCO Detector

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Instruction Manual Eagle Series

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

Clip SGD. Portable single Gas Detector. User manual

Operating Instructions Compur Monitox plus

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

Recalibrate the way you look at gas detection

INSTRUCTION MANUAL MODEL GX-82A

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Transcription:

B -MG0 i gle G Detecti A rm Ma a nstructio Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com

Notice: BST-MG01 single gas detecting alarm is applied to operation of portable gas detectors like Oxygen(O2), Hydrogen Sulphid(H2S), Carbon Monoxide(CO), Nitrogen Monoxide(NO), Nitrogen Dioxide(NO2), Hydrogen(H2), Sulphur Dioxide(SO2), Chlorine(CL2), Ammonia(NH3), thylene Oxide(ETO), Carbon Dioxide (CO2), etc. This manual will take Oxygen(O2) gas detector for example to demonstrate, gas detector for other gases have similar specification, please refer to appendix for detailed parameters.

1 A c BST-MG01O2 portable O2 gas detecting alarm is applied to the underground coal mine, petrochemical industry, municipal, environmental protection and other spaces where it need to detect the O2 gas concentration in the environment and provide a alarm function. When the O2 gas concentration in the environment is higher or lower than that of preset alarm point, this device will send out sound and light alarm to warn the user who wears it to take protective actions. This device is portable and can be also used as a fixed device. This device is intrinsically safe and explosion-proof under mine, the explosion-proof sign is Exib l. W rki pl The sensor of this device adopts electrochemical principle. The electrode inside the O2 sensor will react with O2 gas in the role of catalyst to achieve the directional movement of electron between electrodes, and make the electrical signal amplified and displayed by amplifyingcircuit technology and other existing technologies so that to achieve the detection of concentration. IR CO2 sensor adopts infrared principle. g d vi Notice: To charge the battery, ensure you are in a safe, non-hazardous area. Input voltage: 110-240V, 50-60Hz Output voltage: 5V, 500mA. It can be charged from 5V USB socket through connecting USB cord with this device. USB socket could from computer, phone adapter, power station, etc. After connecting USB cord with this device, green LED flashing indicates regularly charging. When green LED stops flashing and remains light, it indicates charging is basically completed, to enlarge battery life, please don t unplug charging device right away, instead remain it on charge for another hour. 1

w t n mpo Item 1 2 3 4 5 6 7 8 9 10 11 12 Description Alarm light Calibration mask fixator Calibration mask Display screen button Buzzer Front cover USB plug Clip Label Back cover Mounting screw Technical indicator Parameter Measuring range (0.0-30.0)% vol Measurement error ( >5.0~30.0)%vol ±0.9%vol Resolution ratio Display Liquid crystal display LCD display Response time 35s (T90) Alarm sound intensity 75dB Alarm light 20m visible High alarm point Low Alarm point ( 0.0-5.0)% vol ±5%vol 0.1%vol Alarm way Sound, light Continuous working time hours 25.0%vol (can be adjusted in whole range) 18.0%vol (can be adjusted in whole range) 2

Technical indicator Sensor lifetime Working current Battery model Battery short circuit current Charging time Protection degree Working temperature Size 6.0peratlion instructio1n1 CD Instruction of buttons Button OK On/ off button yes button Parameter ;::2 year (<!:5 years for IR sensor) 5mA 3.7V/1500mA 2A 4-5 hours IP65-25c>--55C:; short time for -4o c-ss c 105x54x32 (mm) 6. up button set the data value V down button set the data value On/ off operation Step Long press on/off button to activate this device, display Long pr : ss I our company logo "BESANTEK", then go into normal detecting interface. Description start this device or shut it down, please long press (D press OK (change between detecting interface and function interface) 3 display I 109'50 BESANTEK :c,-1 1 2 1 20. 91

8 nd m nte Wh n m n n th n t h n ny m n n m r pec cati n an m el nam Test Equipment Depot - 800.517.8431-9 TestEquipmen This device should be kept by special person, and build a registration system. This device should be stored in dry and well ventilated places if it s not used for a long time. DO NOT disassemble this device at will, it must be repaired by specialists. 9 o e oti If this device couldn t be turned on, maybe it has no power, please charge it firstly. If the value of this device is not zero in clean air, please carry on zero setting firstly. except Oxygen If this device couldn t test accurately, please carry on calibration firstly. If this device becomes expired, please purchase a new one. 10

A m ix (Zero setting for all these gas sensors except oxygen sensor must be carried out in clean air) Gas Detecting range Resolution Respond time Zero setting gas & concentration Calibration gas &concentration Gas flow(ml/min) O2 (0~30)%vol 0.1%vol 35s(T90) N2 100%vol O2 20.9% / CO (0~1000)ppm 45s(T90) CO 500ppm SO2 (0~20)ppm 45s(T90) SO2 10ppm NO (0~250)ppm 45s(T90) NO 100ppm H2S (0~100)ppm 45s(T90) H2S 50ppm H2 (0~1000)ppm 45s(T90) H2 500ppm NO2 (0~20)ppm 45s(T90) NO2 10ppm NH3 (0~100)ppm 45s(T90) NH3 50ppm CL2 (0~10)ppm 45s(T90) CL2 5ppm 500 ETO (0~20)ppm 140s(T90) C2H4O 10ppm IRCO2 (0.00~5.00)%vol 0.01%vol 45s(T90) N2 100%vol CO2 2.50%vol 250 IRCH4 (0.00~5.00)%vol 0.01%vol 45s(T90) CH4 2.50%vol 250 11

Sensor name CO H2S O2 (0-20)ppm: ± 2ppm (20-100)ppm: ± 4ppm Error /Deviation (100-500)ppm: ± 5% of testing gas (500-1000)ppm: ± 6% of testing gas (0-49)ppm: ± 3ppm (50-100)ppm: ±10% of testing gas (0.0-5.0)%vol: ± 5%vol (5.0-30.0)%vol: ± 0.9 % SO2 (0-20)ppm : ± 5%FS or ± NO NO2 H2 NH3 CL2 ETO IR CH4 (0-250)ppm : ± 5%FS (0-20)ppm: ± 5%FS or ± (0-1000)ppm : ± 5% of testing gas (0-100)ppm: ± 5%FS (0-10)ppm: ± 5%FS or ± (0-20)ppm: ±10%FS (0.00-1.00)%vol: ± 0.06%vol (1-100)%vol: ± 7% of displayed value IR CO2 (0-0.5)%vol: ± 0.10%vol (0.5-5.0)%vol: ± (0.1%vol + 5% of testing gas) 10