Heat Pumps for Swimming Pools extend the season or swim year round

Similar documents
POOL & SPA SUCTION FITTINGS

DIGIHEAT IN LINE HEATERS

PORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING

Pool heating, efficiently

QUANTUM. Reliable solar hot water, whenever you want it

ASTRALPOOL HEAT PUMP CATALOGUE

Pool & Spa The Duratech Heat Pumps

Pool & Spa The Duratech Heat Pumps

ULTRATEMP HIGH PERFORMANCE HEAT PUMP

ASTRALPOOL HEAT PUMP CATALOGUE

Owners Manual PORTAPAC

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

POOL & SPA HEATERS THE EFFICIENT WAY TO HEAT YOUR POOL

Owner s Manual for Swimming Pool Heat Pump

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.

Technical Data Ducted Three Phase Split System Air Conditioner

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Commercial Heat Pump Water Heating Solutions

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

Environmental Free Efficient

ATV ROBOTIC POOL CLEANER

SWIMMING POOL HEAT PUMPS

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

Call or visit solarshop.com.au

Clipsal Integrated Systems International Representatives China Head Office Greece Hong Kong South Africa Offices in all States Taiwan NSW VIC

Viron evo Gas Heater. Viron evo Gas Heater. A product of today s thinking and global challenges. Reduces operating costs by up to 20%

Owner s Manual PRINTED IN CANADA 05/2009

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

comfort BY CONTROL POOL AND SPA HEATING SOLUTIONS

Commandomatic Ezysoft WATER SOFTENER SYSTEM

PRODUCT RANGE: ROOFTOP PACKAGE

G&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual

Saving energy comes naturally to us.

Pure Glass. saturn.clipsal.com

- Murdoch University, Western Australia.

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Innovative, Energy Efficient Water Heating Technology

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

Heat Pump Water Heater Commercial Leaflet 2012

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

Air Cooled Packaged Units

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Inverter Ducted Air Conditioners

SWIMMING POOL HEAT PUMP Owners Manual

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Samsung Free Joint Multi Air Conditioning System

AQUATECH Heat Pump. Temperature Control System for Swimming Pools

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

INSTALLATION & USER MANUAL NATIONAL. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual 1

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Why Choose an AquaCal Heat Pump to Heat My Pool?

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Heatseeker Plus Solar Pool Heating

HEAT PUMPS EN - flyer 10/p/2017 Made in Poland

RHEEM DOMESTIC HOT WATER

Heating in residential pools

Condensing Units CUS 15-60

Rheem Guide to Solar Hot Water

SWIMMING POOL HEAT PUMP

A Technical Introduction to Cool Thermal Energy Storage Commercial Applications

OWNER S Manual PRINTED IN CANADA 10/2009

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Energy Saving of Inverter Air Conditioner and R32 Refrigerant DAIKIN VIETNAM. 13 th May 2017

Extend your swimming & spa season with THERMEAU s residential heaters.

QUANTUM 340 LITRE TITAN HEAT PUMP WATER HEATERS AND THE APPLICATIONS

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

INSTALLATION INSTRUCTIONS

RHEEM DOMESTIC HOT WATER

Installation Manual Compac 6/8

Split System AIR CONDITIONING RANGE. Australians love a Kelvinator

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

Ducted Split System Air Conditioners Technical Data

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION

50A KP 70A KP 90A KP 120A KP 150A KP 210A

Swedish design and manufacture since 1967

VAPOUR RECOVERY DURING FUEL LOADING. Ben Adamson Principal Engineer Refrigeration Engineering Pty Ltd, NSW Australia

Q&A 2016 Practical Guide

Sweden s leading air source heat pump

Accelera Heat Pump Water Heaters HEAT PUMP WATER HEATERS

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

INSTALLATION & USER MANUAL

Whole of Home ADD ON. Add some cool comfort to your life. That s better. That s Actron.

Ducted Split System Air Conditioners Technical Data

RHEEM DOMESTIC HOT WATER

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

F Series - Refrigeration dryers

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual

Product Brochure Smart Power. Low Profile Ducted

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

Leading edge Add-on cooling for ducted gas heating

So far, we have covered the basic concepts of heat transfer and properties.

More Choices. Rheem Compact Series. Rheem Classic Series. Rheem Classic Series Stainless Steel. Model M2350ti M3350ti M4350ti M5350ti

INSTALLATION AND USER MANUAL

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Inverter Hot Water Heat Pumps

Transcription:

Heat Pumps for Swimming Pools extend the season or swim year round www.waterco.com.au

Energy efficient heating A swimming pool is a major financial investment. Getting the most out of your pool, means keeping the pool at a swimmable temperature for the maximum number of hours in each day and the maximum number of days in each year. A heat pump will economically keep your pool warm 24 hours a day. Compared to gas and electric heaters, the Electroheat and Electroheat Plus ranges use just a fraction of the energy to generate the same amount of heat and unlike solar heating; there is no reliance on the sun as the latent heat in the air is used. The Electroheat heat pump range are an ideal solution for heating: Swimming pools to extend the season Swimming pools for year round enjoyment Plunge pools Swim spas and spas Cost effective heating Heat pumps only require energy to operate a compressor and a fan motor, using low amperage in the process. For every 1kW of electricity consumed, Electroheat can produce up to 5 kw of heat. Save up to 80% over propane gas, 50% over natural gas and 500% over electric heaters. 1

How the Electroheat works Electroheat uses refrigeration technology to extract heat from the surrounding air and transfers it to the swimming pool. Heat extraction The fan circulates air through the evaporator air coil that acts as a heat collector. The liquid refrigerant in the evaporator air coil absorbs the available heat from the ambient air. Heat Transfer The heat from the hot refrigerant flowing inside the heat exchanger is then transferred to the pool water. Heat Intensification The compressor then receives the warmed refrigerant and intensifies the heat. The intensely hot refrigerant is then pumped into the heat exchanger. Recycle The refrigerant restarts the process and flows through the evaporator air coil to collect heat once again. 1. Warm air in 2. Fan 3. Evaporator 4. Warm gas 5. Cool air out 6. Compressor 7. Heat exchanger 8. Filter 9. Water Pump 10. Pool 10 1 Heat Extraction Heat intensification 4 5 6 Heat Transfer 7 8 9 2 3 Recycle 2 www.waterco.com.au

Electroheat MKIV pool heat pumps feature compact design and horizontal venting and are ideal for heating: Swimming pools to extend the season Plunge pools Swim spas Spas Available in 9,12, 15, 19 & 23kW heating capacities Electroheat Plus MKIII pool heat pumps feature vertical venting and a large evaporator area for maximum performance and are ideal for heating: Swimming pools for year round enjoyment Swimming pools to extend the season Swimming pools where roof space for solar is limited Available in 25, 31, 37 & 44kW heating capacities 3

SMART CONTROLS for temperature management and self diagnosis INBUILT SAFETY DEVICES for water flow, refrigerant level and compressor startup delay POWERFUL HEAT TRANSFER through the coiled heat exchanger maximising water contact TITANIUM heat exchanger coil is highly resistant to ozone, iodine, baquacil, salt and chlorinated water LARGE EVAPORATOR AREA to extract more ambient heat SCROLL COMPRESSOR for improved efficiency and high performance WEATHERPROOF CABINET for outdoor installation R-410A R410A REFRIGERANT, ozone friendly and maximises performance 5 YEAR WARRANTY Residential 2 + 3 years and Commercial 1 year Conditions apply, see the Waterco Limited warranty set out in the Waterco Warranty Booklet or view it at www.waterco.com.au 4 www.waterco.com.au

Frequently asked questions Should I use a pool cover? The most effective way to prevent heat loss is to install a pool cover. An un-blanketed pool loses 2-3 times more heat than a blanketed pool. Pool covers virtually eliminate evaporation and reduce heat loss by insulating the surface of the pool, greatly reducing pool heating costs. As with all pool heaters, it would be advisable to use a pool cover at night, and when the pool is not in use. What is the minimum ambient operating temperature? The heat pump will actually operate down to an ambient air temperature of 10 C, but with minimal heat output. Therefore we recommend that the minimum operating temperature should be 10 C. What is the best location for the Electroheat? The location of the Electroheat is very important in keeping installation costs to a minimum, while providing for maximum efficiency of operation as well as allowing adequate service and maintenance access. The unit should be located as close as practically possible to the existing pool pump and filter to minimise water piping. The use of 90 degree bends and short radius elbows in the water piping should be kept to a minimum. The longer the distance from the pool, the higher the heat loss from the piping. Can the Electroheat be enclosed? The Electroheat is designed for outdoor installation and should not be installed in totally enclosed areas such as a shed, garage, etc., unless mechanical ventilation is provided to ensure adequate air exchange for proper operation. Re-circulation of cold discharged air back into the evaporator coil will greatly reduce unit s heating capacity and efficiency. What is the Electroheat s performance dependent on? Performance will fluctuate depending on water and weather temperatures. 5 important factors determine the performance of Electroheat: 1. Size of the pool 2. The desired temperature of the pool 3. Ambient air temperature - the warmer the air, the better the performance 4. The presence of a pool cover 5. The size of the heater What is the Electroheat s heater running time? Most units should be sized to operate during the pool filtering cycle time of 8-12 hours daily, providing a steady flow of heated water. On warmer days the heater will run less because the heat loss will be less. Electroheat heat pumps have a lower heating capacity on a BTU/hr basis compared to fossil fuel based pool heaters such as gas heaters. Therefore, Electroheat heat pumps require longer operation to accomplish the desired temperature. Between 10 C to 18 C, it will increase your water temperature by 3 C to 5.5 C a day. Over 21 C you should obtain an increase up to 0.8 C a hour and over 26 C up to 1.1 C an hour depending on the size of the pool, the size of the heat pump, the water temperature, and the ambient air temperature at the moment of operation. Even though the Electroheat may require longer operation, it will still heat the pool far more economically. How does Electroheat compare with solar heating and gas heating? Solar Fuelled by the power of the sun, solar heating systems are a low-cost method of heating up your pool water. As solar heating is reliant on the sun, they are best used to extend the swimming season. Virtually no operating costs, just the cost of electricity to pump the pool water through the solar absorber on the roof. Gas heaters Gas heaters are the fastest method for heating your pool, providing a comfortable temperature for swimming on demand. Gas is best for heating pools or spas for short periods of time. Gas heaters can easily maintain any desired temperature regardless of the weather. Gas heaters are effective, but expensive to operate. Heat pumps Heat pumps may not heat up the swimming pool as fast as gas heaters, but are more energy efficient. Heat pumps require a small amount of electricity; its heat energy source is extracted from the ambient air. 5

Clearance Clearance to rear minimum 30cm No obstruction to top Clearance to side Minimum 30cm Clearance to rear minimum 30cm No obstruction to front Clearance to side Minimum 30cm Dimensions H H W L W L 6 www.waterco.com.au

Electroheat MKIV & Electroheat Plus MK3 Range Performance Specifications Electroheat MKIV Electroheat Plus Nominal Power Output (kw)* 9 12 15 19 23 25 31 37 44 Nominal Heating Capacity BTU* 30700 41000 51000 64000 78,500 85,000 105,000 125,000 150,000 Product Code 278094 278122 278151 278191 278231 2782533 2783133 2783733 2784433 Power Output (kw): Air 26C / Water 26C / RH63% 8.9 11.7 13.5 18.5 21.8 24.5 30.6 36.2 43.7 COP 5.7 6.1 6.1 6.3 6.2 4.9 5.5 5.4 5.7 Power Output (kw): Air 15C / Water 24C / RH70% 6.8 9.2 9.4 17 20.0 22.5 28.5 35.0 42.0 COP 4.8 4.8 4.3 5.8 5.7 4.5 5.2 5.2 5.4 Supply Voltage (VAC) 230-240 380-415 Supply Voltage Phase Single Phase Three Phase Power Consumption (kw/h) 1.5 1.9 2.2 2.9 3.5 5.0 5.6 6.7 7.7 Full Load Amps (AMP) 9 12 12 22 30 12 14 15 17 Minimum Breaker or Fuse (AMP) 16 20 20 32 40 20 25 25 32 Electrical Connection 10A 3 Pin Plug 15A 3 Pin Plug Related products: Electroheat Ultra range - Pool heat pumps with hot gas de-icing for cold climates. Electroheat Pro range - Pool heat pumps for commercial applications. Terminals Min. / Max. Ambient Air Temperature (C) 10 / 40 Min. / Max. water inlet temp (C) 18 / 40 Water Connections (mm) 40mm Min. / Max Water Flow Rate LPM 120-230 120-230 132-303 Weight (kg) 50 54 78 84 87 89 93 Dimensions W x L x H (mm) 1170 x 320 x 685 750 x 850 x 1000 890 x 880 x 1130 Refrigerant R410A Sizing Chart to Heat Your Pool to 28ºC Temperate Location * Warm Location ** Up to 10 hrs / Day Run time Up to 10 hrs / Day Run time Pool Size (m) Litres with Pool Cover No Pool Cover with Pool Cover No Pool Cover 3 x 6 Up to 23000 9kW 15kW 9kW 9kW 3 x 7 Up to 27000 9kW 15kW 9kW 9kW 4 x 7 Up to 35000 12kW 23KW 9kW 15kW 4.5 x 8.5 Up to 50000 15kW 31kW 9kW 19kW 5 x 10 Up to 65000 19kW 44kW 12kW 23kW 5.5 x 11 Up to 80000 23kW 25kW x 2 15kW 31kW 6 x 12 Up to 100000 31kW 31kW x 2 19kW 37kW 6 x 15 Up to 120000 37kW 37kW x 2 23kW 44kW Note: Size and performance are influenced by ambient temperature, humidity, use of a pool cover, night time temperature, pool location, wind factor, water features and if the unit is switched off over night. The recommended sizing in the table above is based on operating the unit up to 10 daytime hours with the pool subjected to normal suburban wind. No allowance has been made for the cooling effects of water features, negative edges or high wind areas. Therefore, any under sizing of the heater for your pool heating requirements is not the responsibility of Waterco. * Temperate Location (Sydney) :- Where minimum average daytime temperatures between September to April are not less than 18ºC. ** Warm Location (Brisbane) :- Where minimum average daytime temperatures between September to April are not less than 24ºC OFFICES - AUSTRALIA NSW - Sydney (Head Office) Tel: +61 2 9898 8600 QLD - Brisbane Tel: +61 7 3299 9900 VIC/TAS - Melbourne Tel: +61 3 9764 1211 WA - Perth Tel: +61 8 9273 1900 SA/NT - Adelaide Tel: +61 8 8244 6000 ACT Distribution Tel: +61 2 6280 6476 OFFICES - OVERSEAS Waterco (Europe) Limited Sittingbourne, Kent. UK Tel: +44 (0) 1795 521 733 Waterco (USA) Inc Augusta, Georgia, USA Tel: +1 706 793 7291 Waterco Canada Longueuil, Quebec, Canada Tel: +1 450 748 1421 Waterco (NZ) Limited Auckland, New Zealand Tel: +64 9 525 7570 Waterco (C) Limited Guangzhou, China Tel: +86 20 3222 2180 Waterco (Far East) Sdn Bhd Selangor, Malaysia Tel: +60 3 6145 6000 PT Waterco Indonesia Jakarta, Indonesia Tel: +62 21 4585 1481 Waterco Singapore Intl Pte Ltd Nehsons Building, Singapore Tel: +65 6344 2378 DISTRIBUTED BY: ZZB1600 10/17 In the interest of providing better quality and value we are constantly improving and updating our products. Consequently, pictures and information on our brochures may sometimes vary slightly from models available.