TECHNOLOGY WEDGE PRESSURE HV JUICE PAGES 2 & 3. Pop-N-Work Pop-Up Tents PAGE 5. June/July This Issue.

Similar documents
LIGHT UP YOUR WORKSPACE

HV JUICE. CellCube GREEN ENERGY STORAGE. New! ECOPillar Link Pillar. Aug/Sept This Issue PAGE 3. PAGE 5 RAYCHEM ELBOW SENSOR

DOES YOUR CABLE COVER COMPLY?

HV JUICE. RAYCHEM RAYSULATE Asset & Outage Protection. ECOLight Solar LED Streetlight Kit. June/July This Issue PAGE 4-5 ECO.

Section 8: Switchgear Connections (Straight & Elbows)

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

Energy Division. CSJT MV cold shrinkable joint for 3-core cables with resin encapsulation

Energy Division. CSJR / CSJH Cold shrinkable straight joints for polymeric insulated cables up to 36 kv

SENTINEL A - Fault Passage Indicator

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE

Reliable solutions for electrified railway systems

PolyGarde Metal-Oxide Surge Arresters

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

LV JUICE FREE RAYCHEM MARINE BAG OF FRUITBURSTS. February This Month. When you spend over $300 (excl GST) on one invoice this month

SENTINEL D - Fault Passage Monitoring

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

RELIABLE SOLUTIONS FOR ELECTRIFIED RAILWAY SYSTEMS

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

Energy Division

Section 5: Medium Voltage Joints - up to 42kV

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

Energy Division. DAH series (IEEE) Distribution metal oxide surge arrester

TRANSNET LED GIFT WITH PURCHASE LV JUICE UNDER LIGHT ECO LEDUV INDUSTRIAL BATTEN LIGHTS VERANDAH. Pack of Pineapple Lumps While stocks last

FREE TE POWER BANK. Power bank colour chosen at random

RAYCHEM MEDIUM VOLTAGE

M7100 Pressure Transducer

Heat-Shrinkable Termination System for Cables up to 36 kv

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA1 Series, (IEC)

FALCON SERIES 12 METAL CLAD

SECTION AUTOMATIC TRANSFER SWITCHES

MXSU - Selection table 3-core Kits / X-section

FALCON SERIES 12 METAL CLAD

Renewable Energy. System Solutions

Section 4: Medium Voltage Terminations - up to 42kV

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Energy Division. Raychem Insulation Enhancement Systems

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

COMPONENT SOLUTIONS for the lighting industry

Communication Solutions for Energy Generation, Transmission and Distribution

CMT MANUAL 6. NMC SENSORS

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

20 20 MARKET SOLUTIONS INSPIRATION INNOVATION INTEGRATION. Industrial Solutions

Guide Specification Model CTG Automatic Transfer Switch

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

Cartridge Heaters. Components. Application Guidelines

CHAPTER 20 SERVICE EQUIPMENT

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MC-100V & BC-100V Operation / Installation Manual

AlarmLine Linear Heat Detector

Policy and Specification for the Interface with Independent Distribution Network Operators Installations

Connectors for Optic Fibre Cable

RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

RENEWABLE ENERGY. Durable solutions for maximum efficiency and the promise of reliability. ENERGY PIONEERS IN POWER SOLUTIONS

High Performance LSZH Fire Resistant Cable

HYDRAULIC CRIMPING TOOL

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

Fibre Solutions for Harsh Environments

Partswasher and Workshop Solutions COMMERCIAL

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers

Manual / Handbuch Spare parts list / Ersatzteilliste

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

LIGHTING CAUTION NEW LISMORE 9 ARM CHANDELIER W 110V

Product Catalogue. Safety Equipment. Capacitive Voltage Detectors and Voltage Detection Systems

LC3000 Level Controller Installation and Maintenance Instructions

Touchpoint Plus. A whole new control experience

ADVANCE ECB ELECTRIC COMBINATION BOILER

EASYkleen TEC BRUSH. DC Weld Electropolisher

Guide to Transmission Equipment Maintenance

LOW VOLTAGE SPLICES & TAPS

ANCILLARY LIGHT CURRENT EQUIPMENT

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

Electrical Preventive Maintenance (EPM) Program

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

SPECIFICATION NPS - 210/6 FOR SF6 INSULATED SWITCHGEAR FOR SYSTEM RATED VOLTAGE UP TO 24 kv

WLS-T25 Solar Powered Low Intensity Duty & Stand-by Aviation Obstruction Light

GENERAL SPECIFICATION ELECTRICAL

The next generation thermometer from the global leader

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

ROLLAIR AIR COMPRESSORS

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

PANELBOARDS & BUILDING DISTRIBUTION

Weed Model N9013. Surface Mount Thermocouple. Nuclear Qualified

WILDLIFE AND ASSET PROTECTION PRODUCTS

VAMP 120 & 121. Arc flash detection units. Product picture

Transcription:

HV JUICE June/July 2018 WEDGE PRESSURE TECHNOLOGY PAGES 2 & 3 This Issue Pop-N-Work Pop-Up Tents PAGE 5 BALMORAL OVERHEAD LINE COVERS PAGE 4 LV RESCUE KIT PAGE 7 MEDIUM VOLTAGE JUNCTION BOX PAGE 8

SHEAR-LOK WEDGE PRESSURE EARTH CONNECTIONS, EASY AS 1. 2. 3... SHEAR-LOK is part of the AMP family. AMP is well known in New Zealand and around the world for expertise in wedge pressure technology, and the SHEAR-LOK offers the benefits of this technology. These connectors were designed for use on distribution networks for highly reliable ground rod connections. SHEAR-LOK connectors are a proven performer in NZ with over 25 years of experience. This connector range has been developed for applications in power utility industry where connectors are required to withstand mid range (20kA symmetrical RMS) magnitudes of fault current. Don't be fooled by imitations. AMP SHEAR- LOK by TE has withstood the test of time right here in New Zealand - second to none. For more information please contact your local TransNet rep or our customer service team. SHEAR-LOK 1connectors consist of a tapered C-shaped piece and a wedge joined with a shear head bolt. The rod and earth cable are positioned in the connector accordingly and the wedge is secured into position by hand. 2 Ensuring placement is correct, the shear head bolt is tightened using a six sided hex spanner or socket until the correct torque is reached and the head shears off 3 The connection is made - correctly everytime due to the shear head bolt which pushes the wedge into place as it is tightened. Meets electrical requirements of IEEE 837 Tested to 20kA for 2sec, 41kA peak Wedge Pressure Technology Shear head bolt controlled torque for correct connection every time Removable without conductor damage No special tools Connector body and wedge made of high strength bronze, shear head bolt made of Silicone bronze Taps into existing ground conductors without the need to cut Range taking capability No molds or charges Lower applied costs Can be applied in any weather Can be applied at any angle Lower stores inventory No special storage requirements Application not inhibited by disfigured ground rod end faster application

AMPACT TAP THE TECHNOLOGY BEHIND THE WORLD'S MOST RELIABLE TAP BENEFITS OF THE AMPACT SYSTEM Industry standard tooling - used throughout NZ No variables when using the proven "AMPACT System" The same quality connection every time Removable & reusable with no damage to conductors Gel covers available to ensure integrity of the connection in harsh NZ environments (especially in bi-metal situations) Lightweight - easy to use Fast installation time PRODUCT FEATURES Design maintains lower resistance throughout connector service life Controlled tapers ensure permanent interlocking of components for repeatability and variance prevention Inhibitor with abrasive particles cleans contact surfaces to reduce corrosion and line loss Tap spring member flexes to maintain constant contact pressure during thermal expansion/contraction Integral locking feature prevents environmental loosening Unique grain structure produces increased strength and lifetime reliability IT'S ALL ABOUT HOW IT ARCHES ITS BACK OVER 2.8 MILLION INSTALLATIONS PER YEAR* EXCEEDS REQUIREMENTS OF INTERNATIONAL STANDARD ANSI C119.4 CLASS AA ENGINEERED TOOLING + CORRECT FORCE = PERFECT CONNECTION! The AMPACT Connector's unique spring ability reduces resistance, helping the connector and connection remain cooler. AMP FROM TE CONNECTIVITY - TRUST THE INVENTORS OF WEDGE PRESSURE CONNECTORS! *Worldwide

BALMORAL OVERHEAD LINE COVERS Panther Tails Panther Tail is a flexible conductor cover with a unique two tone design (black outside, yellow inside) for ease of visual inspection. Perfect for LV applications, Panther Tails meet the requirements of AS 4202 Class I, Appendix B. Supplied in a roll of 60m, with a special zip lock style fastening system, Panther Tails are quick and easy to install and can be cut to fit the required area exactly. FEATURES Excellent weathering, UV, & abrasion resistance Low voltage or high voltage applications Lightweight and easy to install Tiger Tails Also known as line cover, Tiger Tails provide temporary electrical insulation, mechanical protection and visual warning of power lines and conductors. Used by utilities and electrical contractors, these robust units have decades of engineering and development to ensure the highest quality and safety standards. Made from HDPE plastic with a mechanical interlock fastening system. Certified AS4202, Class I and voltage rated 650V. Cat No. DB.35A 2.5m LONG x 35mm ID, BLACK/YELLOW Cat No. TPP15 60m LONG x 15mm DIAMETER, BLACK/YELLOW balmoral engineering

POP'N'WORK POP-UP WORK TENTS & SHELTERS Get the work done, rain or shine FEATURES top level concerns for any business, & these products offer features that help to increase production levels while providing a safer working environment! DE IN THE SA the ability to provide you with a truly customised, quality product. Customisations include branding with your logo or changing to your colours (MOQ required). Job safety & productivity are U Pop'N'Work offers a complete range of quick & easy pop-up work shelters. The high quality & durability of these products is unsurpassed! With the design flexibility to meet specific client needs we have MA No loose pieces to lose Set up or take down in 30 seconds by yourself UV & flame resistant Range of door designs Add your company logo Durable construction, stands up to strong winds Pre-set and custom sizes available Single and two door options available Quick Pak Flap for easy storage and transport Ground Tents, Dielectric Aerial Tents, Canopies, Umbrellas, Customisation

COMPLETE INLINE DISCONNECT SWITCH KIT new Facing more shutdowns? Minimise the number of customers affected with an inline switch. Product # ILDIS-SWITCH-COMP Designed for use on all New Zealand MV networks, this kitset contains all the components you need to install an inline disconnect. Assembled, tested, and ready to go, this unit is perfect for emergency applications. INLINE DISCONNECT FEATURES 15-35kV, 900A Polymer Insulator Silver plated cooper blades Marine grade 316 Stainless Steel Integral 90 blade stop Silver plated brass contact and hinge Tin plated copper terminals Pull to Open / Pull to Close operation FLEXIBLE CABLE FEATURES 50mm² Flexible Cu Stranded Conductor (Class 6) Transparent PVC Insulation Meets requirements of IEC 61138 and IEC 60227-1 This kit contains the highest quality components including an Inline Disconnect Switch manufactured in the USA and suitable for 15-35kV & 900Amps. Kitset designed and assembled in New Zealand. KITSET COMPONENTS Inline Disconnect Switch Integrated turnbuckle with podger featuring removable handle Industry standard live line clamps for leads 50mm² Flexible Copper leads with clear sheath, 1.5m long

SUPER DEALS LOW VOLTAGE RESCUE KIT Designed for use in emergencies around LV electrical systems, this LV rescue kit is perfect for all staff tasked with working on live LV electrical systems, whatever the location. Supplied in a heavy duty yellow bag for ease of identification, it features clearly labelled essential emergency items with a contents list printed on the inside flap to ensure easy restocking. lvrescuekit $125. 00 +gst FEATURES High quality components Complies with all relevant standards Essential for anyone working on live electricity and live poles Suitable for anyone at risk of electric shock including emergency services KIT CONTAINS Electrosoft 1000V Electrical Gloves Size 10 First Aid Booklet Multi Trauma Dressing Isolate Here Sign LV Rescue Hook Eveready 2D Brilliant Beam Torch VAL2D Fire Blanket 1.2M x 1.8m AS/ NZS 3504 Approved Heavy duty storage bag FLAIR 213 FOR MV UNDERGROUND NETWORKS The Flair 213 is intended for indication of fault current passage in MV networks, and has been used by MV distribution utilities around the world to reduce service restoration time, improve customer satisfaction, and reduce the loss of revenue generated by the outage. In case of a power failure, the utility must quickly find the source of the problem and undertake repairs. The Flair 213 Fault Indicator flashes whenever it detects the passage of fault current, indicating that the fault is located beyond its own position. The fault is always located between the last flashing and the first non-flashing indicator. FEATURES System-wide adaptability, fully on-site programmable 16 phases to earth fault trip current values 4 sensing time delays 3 automatic reset modes: Timer reset with 8 possible periods of time Manual reset via push button LV reset via 10 kv isolated input SCADA relay output Display option outside the kiosk/ substation Long life lithium batteries IP54 protection IK7 Power save /ECO feature Dimensions: 250 x 160 x 65mm, net weight 720g FLAIR213KITS $395. 00 +gst WHILE STOCKS LAST

Medium Voltage Junction Box For Distribution Networks TransNet New Zealand Ltd Auckland 78 Cryers Road East Tamaki Auckland NEW ZEALAND Fax 0800 442 183 PO Box 39 383 Howick, Auckland Wellington 10 Petone Ave Petone Wellington NEW ZEALAND Ph 04 576 2530 Fax 04 576 0040 PO Box 39 383 Howick, Auckland NEW ZEALAND TransNet Tonga Ma ufanga Small Industries Ma ufanga TONGA Ph +67 627 939 Fax +67 627 976 PO Box 2932 Nuku'alofa TONGA transnet@kalianet.to KEY FEATURES IP66 rated Application in grid connection and wind turbines in on shore and off shore environment Branching point for cross section combinations from 25 to 300 mm² Full metal encapsulation Easy accessibility to the capacitive test points Monitoring & detection of voltage Tested according to CENELEC HD.629.1 S2:2006 + A1:2008 and IP66 with integrated bottom plate SAFE & EASY CONNECTION & DISCONNECTION TE Connectivity s medium voltage junction box contains a set of Raychem screened separable connectors and facilitates the safe, easy, quick connection and disconnection of MV cables up to 24 kv. Suitable for usage in grid connection and wind turbines on and off shore. Supporting a wide application range, it represents a branching point for all cross sections from 25 to 300 mm 2. The overall dimensions are compact and designed to take up a minimum of space, while full metal encapsulation gives reliable and insured service. With an IP66 rating and integrated bottom plate, the junction box is completely secured against water and dust ingress. EVERY CONNECTION COUNTS The MVJB is able to connect all Raychem screened separable connectors RSTI, Coupling Connectors RSTI CC, & Surge Arresters RSTI CC SA. This allows easy accessibility to the capacitive test points for determining whether the circuit is energised as well as providing an opportunity to protect equipment from overvoltages. The possibility to monitor 670 435 and detect the voltage ensures that it functions reliably and safely within the 1150 electrical system. Tested according to CENELEC HD 629.1 S2, which includes BS, VDE and other international specifications. Customers can count on consistent, high quality products, driven by TE s proven innovation and backed by our extraordinary customer support. TransNet NZ Ltd has made every reasonable effort to ensure the accuracy of this information and it is to the best of our knowledge correct and reliable. Under no circumstances does this constitute an assurance of any particular quality or performance and users should independently evaluate the suitability of products for their desired application. All information in this publication including pricing, drawings, illustrations, images and graphic designs are reflections of our current understanding. TransNet NZ Ltd reserves the right to make any adjustment to this information at any time. Our liability for the products outlined in this publication is set forth in our standard terms and conditions of trade. In case of any potential ambiguities or questions, please contact us for clarification.