RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

Similar documents
O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

RLA kw TECHNICAL MANUAL AIR COOLED WATER CHILLERS WITH HELICAL FANS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

Galletti Water chillers and heat pumps catalogue

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Water chillers water/water type SIGMA Technical information manual

LZA High efficiency air to water heat pumps with HP compressor

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

LZT High efficiency air to water heat pumps with E.V.I. compressors

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Blue Box Epsilon Echos +

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW


Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Air cooled industrial chillers

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Aquaflair TRAC-TRAF-TRAH

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

1

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

ELFOEnergy Duct Inverter

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

PYXIS U PYXIS U. rcgroupairconditioning

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

44,9 202,0 kw. technicalcatalogue

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

CRIMSON & CRIMSON MAX

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

PRODUCT GUIDE

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Air Cooled Chillers & Heat Pumps WinPACK HE-A

H4T R410A. refrigerant

kw COOLING kw HEATING

Air-to-water scroll chillers

HYDRONIC RESIDENTIAL

Advance Split

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Neosys Product catalogue

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

ELFOEnergy Extended Inverter

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

SyScroll 40 to 75 Air NEW

pyxis u pyxis ua NEW rcgroupairconditioning

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

LZT High efficiency air to water heat pumps with E.V.I. compressors

HT V2 HT Split

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw

RFA TECHNICAL MANUAL SINGLE PACKAGED ROOFTOP UNITS ROOF-TOP. Mod

PRODUCT RANGE HEAT PUMPS 2012

nemo a hp rcgroupairconditioning R410A

AQUASNAP JUNIOR 30RHV

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

GLIDER EVO GLIDER EVO. rcgroupairconditioning

kw. technicalcatalogue

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Conditioning your ambient, maximising your comfort.

Transcription:

A RE F S E -FRIEND Y R E IG RA N T G AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L RTA C TECHNICAL MANUAL 1

2

SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE HEADING OF EACH PAGE. GENERAL FEATURES...............................................................................4 General specifications.............................................................................4 European Directives...............................................................................4 Identification plate of the Unit........................................................................4 Presentation of the unit.............................................................................5 Unit identification code.............................................................................6 Description of the component........................................................................7 ACCESSORIES AND OPTIONAL EQUIPMENT........................................................... 10 "Storing and hydronic kit" options.....................................................................10 Options.........................................................................................11 Accessories.....................................................................................12 Mechanical options................................................................................12 Electrical options..................................................................................12 TECHNICAL DATA AND PERFORMANCE - BASE VERSION (VB)........................................... 13 Technical data....................................................................................13 NET NOMINAL performances - Base setting up (AB) - Standard plants - EUROVENT certified data.................14 NET NOMINAL performances - Base setting up (AB) - Standard plants.......................................14 NET NOMINAL performances - Base setting up (AB) - Radiant plants........................................15 NET NOMINAL performances - Low noise setting up (AS) - Standard plants - EUROVENT certified data.............16 NET NOMINAL performances - Low noise setting up (AS) - Standard plants...................................16 NET NOMINAL performances - Low noise setting up (AS) - Radiant plants....................................17 NET NOMINAL performances - Exta low noise setting up (AX) - Standard plants - EUROVENT certified data.........18 NET NOMINAL performances - Exta low noise setting up (AX) - Standard plants................................18 NET NOMINAL performances - Extra low noise setting up (AX) - Radiant plants................................19 COOLING performances...........................................................................20 HEATING performances............................................................................21 Correction factor for the use of glycol in heating mode....................................................22 Correction factor for the use of glycol in cooling mode.....................................................23 Fouling factors...................................................................................23 TECHNICAL DATA AND PERFORMANCE - DESUPERHEATER VERSION (VD)................................ 24 NET NOMINAL performances - IR unit - Standard plants..................................................24 NET NOMINAL performances - IP unit - Standard plants...................................................25 Desuperheaters VD performances....................................................................26 Corrective factors.................................................................................27 TECHNICAL DATA AND PERFORMANCE - RECOVERY VERSION (VR)...................................... 28 NET NOMINAL performances - IR unit - Standard plants..................................................28 Total recovery VR performances.....................................................................29 BR - BP UNIT.......................................................................................30 Corrective factors.................................................................................30 NOISE LEVELS.....................................................................................31 OPERATING LIMITS.................................................................................32 WATER PRESSURE DROP...........................................................................33 Plant side exchanger..............................................................................33 Desuperheaters..................................................................................34 Total recovery exchanger...........................................................................35 WORKING HEAD....................................................................................36 Standard working head pumps.......................................................................36 High working head pumps..........................................................................37 DIMENSIONAL AND PHYSICAL DATA..................................................................38 Dimensional data.................................................................................38 The manufacturer declines all responsibility for any inaccuracies in this manual due to printing or typing errors. The manufacturer reserves the right to modify the products contents in this catalogue without previous notice. 3

4

GENERAL FEATURES Presentation of the unit This series of air-water chillers and heat pumps satisfies the cooling and heating requirements of residential plants of medium size. All the units are suitable for outdoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. The refrigerant circuit, contained in a compartment protected from the air flow to simplify the maintenance operations, is equipped with scroll compressors mounted on damper supports, brazed plate heat exchanger, electronic expansion valve, reverse cycle valve, dehydrator filter, axial fans with safety protection grilles, finned coil made of copper pipes and aluminium louvered fins. The circuit is protected by a safety gas valve, high and low pressure switches and differential pressure switch on the plate heat exchanger. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and to reduce thermal losses. All the units can be equipped with variable speed fans control that allows the units to operate with low outdoor temperatures in cooling and high outdoor temperature in heating and permits to reduce noise emissions in such operating conditions. The low noise acoustic setting up (AS) is obtained, starting from the base setting up (AB), reducing the rotational speed of the fans and mounting sound jackets on the compressors and the technical compartment is clad with soundproofing material of suitable thickness. The extra low noise acoustic setting up (AX) is obtained, starting from the low noise setting up (AS), further reducing the rotational speed of the fans and using finned coil with bigger surface. All the units are supplied with a management and control electrical panel containing general switch, phase presence and correct sequence controller, microprocessor controller with display and all the other electrical components with IP54 minimum protection degree. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation. 5

GENERAL FEATURES Unit identification code The codes that identify the units and the meaning of the letters used are described below. RTA IP 245.3 VB AB 0M5 Unit type IR - Unit suitable for hydronic plant installation operating as chiller IP - Unit suitable for hydronic plant installation operating as reversible heat pump BR - Unit suitable for hydronic plant installation with brine solutions operating as chiller BP - Unit suitable for hydronic plant installation with brine solutions operating as reversible heat pump Power supply 5-400 V - 3-50 Hz Operating range M - Medium temperature. The unit is suitable to be installed in temperate climates. A - Medium temperature. The unit is suitable to be installed in tropical climates. Unit model Refrigerant type 0 - R410A N compressors Unit version VB - Base version VD - Desuperheaters version VR - Total recovery version Acoustic setting up AB - Base setting up AS - Low noise setting up AX - Extra low noise setting up The available special versions are described below: VB: Standard unit. VD: Version with Desuperheater (available forboth IR units and IP units) Produces cold water in the same way as the standard version plus hot water from 30 to 70 C at the same time. This is achieved by installing a water-refrigerant gas heat exchanger between the compressor and coils in order to recover 25 to 30% of the heating capacity that would otherwise be dispersed in the air. It helps to remind that hot water production is possible only in combination with cold-hot water production in the main heat exchanger and it is subordinated by it. VR: Total Heat Recovery unit Produces cold water as in the standard version plus hot water at a temperature of 30 to 55 C at the same time. This is achieved thanks to a water-refrigerant gas heat exchanger that totally recovers the heating capacity that would otherwise be dispersed in the air. The total heat recovery function is enabled and disabled by means of a valve on the compressor delivery of each circuit: when the temperature of the water that enters the recuperator drops, the valve switches the hot gas flow from the condensing coils to the recovery heat exchanger. On the other hand, when the temperature of the water reaches the set-point, the valve shuts off the heat recuperator and switches the hot gas flow to the condensing coils. It helps to remind that hot water production is possible only in combination with cold water production in the main heat exchanger and it is subordinated by it. 6

GENERAL FEATURES Description of the component 1. Fans. Axial type, they are contained in a sheet nozzle and are equipped with a safety grille, scythe-shaped blades increase the efficiency and reduce the noise level. The fans are directly coupled to the single-phase motor by means of an external rotor. Thermal protection against operating faults is installed inside the winding. The fans rotational speed can be modulated continuosly by an analogue device or an inverter (option) to control the condensation pressure (in cooling) and the evaporation pressure (in heating) in order to extend the operating limits of the unit and to reduce noise emissions. Optionally are available Electronically Commutated (EC) fans, which ensure maximum energy efficiency at reduced speed of rotation. 2. Electric control and monitoring panel. It contains all the power, control and security components necessary to guarantee the unit to work properly. The unit is managed by a microprocessor controller to which all the electrical loads and the control devices are connected. The user interface, placed on the frontal panel, allows to view and to modify, if necessary, all the parameters of the unit. This is housed in a metal casing in which the various electrical components are positioned on one metal plate. 2a. The power section includes: Main door-locking circuit-breaker. Fuse-holder that can be isolated with protection fuse triad for each compressor, or thermal magnetic circuit breakers (option). Fuse-holder that can be isolated with protection fuse for compressor oil heaters and antifreeze (if installed), or thermal magnetic circuit breakers (option). Control contactor for each compressor or soft starters (option). Fuse-holder that can be isolated with protection fuse triad for fans, or thermal magnetic circuit breakers (option). Protection fuse for the fans, or thermal magnetic circuit breakers (option). Thermal magnetic contactor switch to protect the pump (if the Hydronic Kit is installed). Phase presence and sequence monitoring device on power supply, or voltage monitor and sequence meter (accessory). 2b. The auxiliary section includes: Fuses on the auxiliary transformer, or thermal magnetic circuit breakers (option). Electromagnetic noise filter Adjusting fan speed board (option) Insulating and safety transformer to power the auxiliary circuit. 2c. The microprocessor monitoring section includes: User interfacing terminal with display. MODE On-off key. Operating mode selector key. C Compressor on-off display LED. Operational mode LED Antifreeze heaters activated indicator LED. Fans on-off dislay LED Pumps on-off display LED Check-control with fault code display Defrosting, alarm, economy, stand-by LED. Control system main functions: temperature control of the water produced by the unit, compressor and pump operating hour counter, timing and cycling of start-ups, input parameters by keyboard, alarms management, smart defrosting control and operating mode change (only IP unit), dynamic setpoint (climatic control), scheduling and integrative heaters control. If you installed the hydronic kit these functions are enabled: antifreeze with pump, start-up cycle after prolonged inactivity (antisticking), if the hydronic kit installed has 2 pumps there is a cycling between each pump to ensure an equivalent lifetime, with inverter modulating hydronic kit the water flow of the plant can be adjusted. Digital input functions: low pressure, high pressure, high temperature on compressor supply, phase presence and sequence monitoring device on power supply, differential water pressure control, compressors thermal protection, fans thermal protection, pumps thermal protection (only if installed MP accessory), ON/OFF and remote operating mode change, demand limit and Economy function, recovery enabling (only for the VR Version), recovery Pump Thermal Protective (only for the VR Version), recovery differential water pressure control (only for the VR Version). Digital output functions: compressor start-up, pump start-up (only with MP accessory), plate heat exchanger electrical heater, remote general alarm, 4-way valve (only IP unit), integrative heaters and clean contact on compressors start-up, recovery valve management (only for the VR Version), recovery pump management (only for the VR Version). Analogic input functions: in and out water temperature, coil temperature probe, external air temperature probe (if present), in and out recovery water temperature (only for the VR Version). Analogic output functions: continuous adjustment of fans rotating speed (option for AB and standard for AS and AX acoustic setting up), continuous adjustment of pump rotating speed (only if hydronic kit with modulating pump is installed). 7

GENERAL FEATURES 3. Compressors. They are the SCROLL type with orbiting coil equipped with built-in thermal protection and oil heater (accessory for IR, as standard for IP). The AS unit includes: a soundproofing jacket for the compressors, to reduce noise level. All units are equipped with three compressors connected in tandem (66% of the cooling power), or parallel (1 single cooling circuit) which can operate at the same time (100% cooling power) or individually (33% of the cooling power), thus adapting to the different thermal loads of the system supplied. 4. Frame, supporting structure and lateral panels are made of galvanized and painted sheet-steel (colour RAL 7035) to guarantee good resistance to the weather. Accessibility to internal parts is possible removing the frontal panel, for other manteinances also the lateral panel can be removed. 5. Evaporator made of brazed stainless steel plates (AISI 316). It is installed in a shell of heat-insulating material to prevent the formation of condensation and heat exchanges towards the outside. Standard supply also includes antifreeze heater a differential pressure switch on the water circuit to avoid the risk of freezing if the water flow is shut off for some reason. 6. Condensing coils, the aluminium finned pack type with shaped profile to increase the heat exchange coefficient and with copper pipes arranged in staggered rows. Hydraulic and cooling circuit components 7.One-way valves (IP/BP unit only), allowing the refrigerant gas to pass into the appropriate exchangers, depending on the operating cycle. 8. 4-way cycle reversal valve (IP/BP unit only), reverses the flow direction of the refrigerant gas as the summer/winter operating mode is changed. - Safety valve. Installed on the delivery pipe of the compressors, this operates if extreme faults should occur in the plant. 9. Fluid valve (accessory). Ball type, this allows the gas flow on the fluid line to be turned on and off. Along with the cock on the compressor delivery, it allows the components of the fluid line to be subjected to extraordinary maintenance work and the compressors to be replaced if necessary (without discharging the refrigerant gas from the unit). 10. Compressor delivery valve (accessory). Ball type, allows the gas delivered to the compressors to be turned on and off. 11. Expansion valve supplies the evaporator correctly, keeping the selected overheating degree at a more steady level; ensures a faster response to load changes and superior stability which translates into increased efficiency at partial loads. 12. Water differential pressure switch. This is standard supply and is installed on the connections between the water inlet and outlet of the exchanger. It stops the unit if it activates. 13. Electrical heating elements to heat the compressor oil. "Belt" type (accessory for IR, as standard for IP). These activate when the compressor turns off and keep the temperature of the oil sufficiently high so as to prevent refrigerant gas from migrating during these pauses. - Dehydrator filter. Mechanical type. Retains impurities and traces of moisture in the circuit. Hermetic type or a cartridge type. - Fluid and humidity indicator. Signals when fluid passes through the circuit, indicating that the refrigerant gas charge is correct. The fluid indicator light also indicates the amount of moisture in the refrigerant gas by changing colour. - Low pressure switch. With fixed setting. It is installed on the suction pipe and blocks the compressors if the operating pressures drop below the tolerated values. Automatically resets as the pressure increases. If it activates frequently, the unit will block and can only be restarted by resetting via the user interface terminal. - High pressure switch (n 2). With fixed setting. Are is installed on the delivery pipe and blocks the compressors if the operating pressures exceed the tolerated values. If it activates, the unit will block and can only be restarted by resetting via the user interface terminal. - Pressure taps: 1/4 " SAE (7/16" UNF) type with flow regulator. Allow the operating pressure of the system to be measured: compressor delivery, lamination component inlet, compressor intake. - Pressure taps: 5/16 " SAE type with flow regulator. Allow the charge/discharge of the gas from the system, precisely from compressor outlet an expansion valve inlet. Fluid receiver (IP/BP unit only), this is a plenum tank that accounts for variations to the refrigerant gas charge the unit must supply as the summer/winter operating mode varies. Fluid separator (IP/BP unit only), on the compressor intake to protect against possible fluid back-flows. 8

GENERAL FEATURES 6 1 2 9 5 12 8 3C 20 3B 4 3A 10 7 11 Desuperheater unit VD (available for both IR units and IP units) Hydraulic and chilling circuit components: - Desuperheater. Specially designed for the specific version. Plate type, made of stainless steel (AISI 316). It is installed within a shell of thermal barrier insulating material to prevent heat exchanges towards the outside. Standard supply also includes an electric antifreeze heater to prevent the parts from freezing during the winter, when the system remains at a standstill (if not drained). Total Heat Recovery unit VR (only available for IR units) Hydraulic and cooling circuit components: - Heat recovery exchanger. Specially designed for the specific version. Plate type, made of stainless steel (AISI 316). It is installed within a shell of thermal barrier insulating material to prevent heat dispersion towards the outside. Standard supply also includes an electric antifreeze heater to prevent the parts from freezing during the winter, if is it not drained. - Differential water pressure switch. Installed on exchanger. It disables the heat recovery version if activated owing to lack of water flowing through the recovery exchangers. - Heat recovery management valve. This delivers refrigerant to the condensing coils or heat recovery exchanger, depending on demands for hot water, and into the appropriate exchangers depending on whether hot water is required or not. - Fluid receiver. This is a plenum tank that accounts for the refrigerant charge variations required by the unit as the operating modes change (condensing in air or in water). - One-way valves. Make the refrigerant obligatorily pass through the appropriate heat exchangers (coils / heat exchanger), depending on the operating mode. 9

ACCESSORIES AND OPTIONAL EQUIPMENT "Storing and hydronic kit" options MKT SS Pipe kit without tank M1P SS 2P STD 1 Standard pump M1P SS 2P HP1 1 High head pump M1PM SS 2P STD 1 Standard modulating pump M1PM SS 2P HP1 1 Standard modulating high head pump M2P SS 2P STD 2 Standard pumps This accessory consists of steel pipes insulated with thermal barrier material and allows the water inlet/outlet connection to be routed outside the unit. Allows the circulation of the water on the plant side. Allows the circulation of the water on the plant side and guarantees a higher available static head, suitable for high pressure drop plants. Allows the circulation of the water on the plant side with the possibility to set the rotational speed of the pump in order to get the requested flow rate without the necessity to install other setting devices. Allows the circulation of the water on the plant side, ensuring a higher available static head, suitable for high pressure drop plants, with the possibility to set the rotational speed of the pump in order to get the requested flow rate without the necessity to install other setting devices. Allows the circulation of the water on the plant side and includes a second pump installed as a backup to the first. Storing and hydronic kit M2P SS 2P HP1 2 High head pumps MKT AM Pipe kit with tank M1P AM 2P STD Tank and 1 standard pump M1P AM 2P HP1 Tank and 1 high head pump M1PM AM 2P STD Tank and 1 modulating standard pump Allows the circulation of the water on the plant side, ensuring a higher available static head, suitable for high pressure drop plants, and includes a second pump installed as a backup to the first. This accessory consists of steel pipes insulated with thermal barrier material and allows the water inlet/outlet connection to be routed outside the unit. The thermal inertia of the buffer tank allows to reduce the number of compressor starts and to guarantee a more stable flow temperature. Allows the circulation of the water on the plant side. The thermal inertia of the buffer tank allows to reduce the number of compressor starts and to guarantee a more stable flow temperature. Allows the circulation of the water on the plant side and guarantees a higher available static head, suitable for high pressure drop plants. The thermal inertia of the buffer tank allows to reduce the number of compressor starts and to guarantee a more stable flow temperature. Allows the circulation of the water on the plant side with the possibility to set the rotational speed of the pump in order to get the requested flow rate without the necessity to install other setting devices. The thermal inertia of the buffer tank allows to reduce the number of compressor starts and to guarantee a more stable flow temperature. M1PM AM 2P HP1 Tank and 1 modulating high head pump M2P AM 2P STD Tank and 2 standard pumps M2P AM 2P HP1 Tank and 2 high head pumps M1P PS 2P STD Tank and 1 standard pump (primary and secondary configuration) M2P PS 2P STD Tank and 2 standard pumps (primary and secondary configuration) Allows the circulation of the water on the plant side, ensuring a higher available static head, suitable for high pressure drop plants, with the possibility to set the rotational speed of the pump in order to get the requested flow rate without the necessity to install other setting devices. The thermal inertia of the buffer tank allows to reduce the number of compressor starts and to guarantee a more stable flow temperature. Allows the circulation of the water on the plant side and includes a second pump installed as a backup to the first. The thermal inertia of the buffer tank allows to reduce the number of compressor starts and to guarantee a more stable flow temperature. Allows the circulation of the water on the plant side, ensuring a higher available static head, suitable for high pressure drop plants, and includes a second pump installed as a backup to the first. The thermal inertia of the buffer tank allows to reduce the number of compressor starts and to guarantee a more stable flow temperature. Allows the circulation of the water on the primary between the tank and the heat exchanger. The thermal inertia of the buffer tank allows to reduce the number of compressor starts and to guarantee a more stable flow temperature. Allows the circulation of the water on the primary between the tank and the heat exchanger and includes a second pump installed as a backup to the first. The thermal inertia of the buffer tank allows to reduce the number of compressor starts and to guarantee a more stable flow temperature. 10

ACCESSORIES AND OPTIONAL EQUIPMENT Without tank Pipe kit without tank With tank Pipe kit with tank SF M SF VS AV OUT S AV OUT SP SA SP SA AV IN AV IN SA SA Standard pump without tank Tank and standard pump VE SF M VS AV OUT M SF S VS AV OUT SP SA RM F VU VU P P RA AV IN SP SA SF RM F VU VU P P RA AV IN ITEM AV F M P RA RM S SA SF SP VE VS VU DESCRIPTION VICTAULIC CONNECTIONS FILTER GAUGE PUMP SUCTION BALL VALVE DISCHARGE BALL VALVE TANK DRAIN WATER VALVE AIR VENT VALVE HEAT EXCHANGER EXPANSION VESSEL SAFETY VALVE CHECK VALVE only in case of 2 pumps Tank and standard pump (primary and secondary configuration) M SF SP SF RM F SA VE VS AV OUT S IN VU P AV VU P Options Soft starter Reduces the compressor start current of about 40%. Compressor power factor correction Fans control Electrical protecion load Drain pan kit On-off Modulating control (condensation / evaporation control) Modulating control (condensation / evaporation control) with EC fans Fuses Thermal magnetic Allows to reduce the phase shift between the absorbed current and the power supply voltage keeping it above the value of 0,91. (standard for AB unit) the condensation pressure (in cooling) and the evaporation pressure (in heating) is regulated by on-off cycles. (standard for AS and AX unit, optional for AB unit) The fans rotational speed can be modulated continuosly by an adjusting fan speed device to control the condensation pressure (in cooling) and the evaporation pressure (in heating) in order to extend the operating limits of the unit, to reduce noise emissions and improve energy efficiency. (optional for AB, AS and AX unit) The fans rotational speed can be modulated continuosly by EC fans (Electronic Commutation) to control the condensation pressure (in cooling) and the evaporation pressure (in heating) in order to extend the operating limits of the unit, to reduce noise emissions and maximize energy efficiency. Allows to protect the electrical loads with fuses. Allows to protect the electrical loads with thermal magnetic circuit breakers simplifying the maintenance and reload operations. Provides a pan under the coil to drain the condensing water, fitted with 1/2" outlet connection positioned opposite to the electric control panel. 11

ACCESSORIES AND OPTIONAL EQUIPMENT Accessories Supplied accessories Rubber vibration dampers Spring vibration dampers Water paddle flow switch Tank antifreeze electrical heater Remote control Programmer clock Modbus serial interface on RS485 Phase sequence and voltage controller Victaulic connections Allow to reduce the transmission to the unit support plane of the mechanical vibrations generated by the compressor and by the fans in their normal operating mode, the degree of isolation is about 85% Allow to reduce the transmission to the unit support plane of the mechanical vibrations generated by the compressor and by the fans in their normal operating mode, the degree of isolation is about 90% Allows to detect the water flow lack through the plate heat exchanger and operates as an integration of the protecion offered by the differential pressure switch (standard). Activated together with the antifreeze electrical heater of the plate heat exchanger, it has the task to keep the still water in the buffer tank at a temperature high enough to avoid ice generation during winter. It is suitable for wall mounting and reports all the control and visualization functions available on the user interface placed on the unit. It therefore allows the complete remote control of the unit. It allows the unit to be turned on and off according to a set program, through the digital input available on the unit wiring board (remote stand by). It allows to communicate with the unit controller and to view the operating conditions of the unit through Modbus communication protocol. The RS485 serial line ensures the signal quality up to distances of about 1200 meters (that can be extended by means of proper repeaters). It checks not only the presence and correct order of the power supply phases but also the voltage level on each phase and avoid the unit to operate with voltage levels outside the permitted limits. This accessory consists of steel pipes that allows the water inlet/outlet to be connected straight inside the unit. Factory mounted accessories Coil protection grilles High and low pressure gauges Protects the external surface of the finned coil. 2 pressure gauges allow visualization of high and low refrigerant gas pressure. Coil shut off valves It consists of two ball valves installed before and after the coil that allow for the pump-down maintenance. Outdoor air sensor External air probe mounted near coil allows smart defrosting, climatic variation of setpoint and reducing the external air temperature below a setpoint. enables heat pump stop High temperature thermostat Low temperature kit Tank antifreeze electrical heater Modbus serial interface on RS485 Phase sequence and voltage controller ATC Advanced temperature control Pressure transducer Cardboard corners Two thermostats in series on compressors outlet pipes preserve operation not allowing temperature to rise up than a specified non adjustable value. (di serie per unità IP e BP, optional per unità IR e BR) sono costituite da resistenze carter di riscaldamento olio compressori. Activated together with the antifreeze electrical heater of the plate heat exchanger, it has the task to keep the still water in the buffer tank at a temperature high enough to avoid ice generation during winter. It allows to communicate with the unit controller and to view the operating conditions of the unit through Modbus communication protocol. The RS485 serial line ensures the signal quality up to distances of about 1200 meters (that can be extended by means of proper repeaters). It checks not only the presence and correct order of the power supply phases but also the voltage level on each phase and avoid the unit to operate with voltage levels outside the permitted limits. It consists of a properly calibrated pressure switch that partializes the unit preventing the high pressure alarm. It consists of a transducer, which allows operation of the control condensation, evaporation and defrost by reading the pressure. Comprised of 4 cardboard corners to further protect the edges of the unit for safer handling Mechanical options Electrical options For finned coils with special treatment (copper fins, tin-copper plated, acrylic, epoxy or hydrophilic painting) please contact our technical department. For other voltages, please contact our technical department 12

TECHNICAL DATA AND PERFORMANCE - BASE VERSION (VB) Technical data Frame 1 Power supply 400-3 - 50 V-ph-Hz Refrigerant Type R410A - Refrigerant circuit Quantity 1 - Compressor Type scroll - Quantity 3 n Power steps 0/33/67/100 % Oil charge CP1A 5.3 5.3 5.3 l Oil charge CP1B 5.3 5.3 5.3 l Oil charge CP1B 5.3 5.3 5.3 l Plant side heat exchanger Type Brazed plates - Quantity 1 n Water volume 11.2 12.8 16.1 l Source side heat exchanger Type Finned coil - Quantity 1 n Frontal surface 9,28 m 2 Fans Type assiale - Quantity 4 5 n Diameter 800 mm Nominal rotational speed AB 900 rpm Nominal air flow rate AB 87066 103650 99700 m 3 /h Nominal rotational speed AS 750 rpm Nominal air flow rate AS 72555 86375 83083 m 3 /h Nominal rotational speed AX 600 rpm Nominal air flow rate AX 5.76 7.2 7.2 m 3 /h Plant side hydraulic circuit Expansion vessel volume 24 l Expansion vessel precharge 150 kpa Expansion vessel maximum pressure 800 kpa Tank volume 460 l Safety valve set 600 kpa Units with primary-secondary pump (option) Type Centrifugal pump - F.L.A. Maximum total current input 208 240 256 A F.L.I. Maximum total power input 126 142 153 kw Units with standard pump (option) Type Centrifugal pump - F.L.A. Maximum total current input 208 240 258 A F.L.I. Maximum total power input 126 142 154 kw 13

TECHNICAL DATA AND PERFORMANCE - BASE VERSION (VB) NET NOMINAL performances - Base setting up (AB) - Standard plants - EUROVENT certified data IR Cooling A35W7 ( source : air in 35 C d.b. / plant : water in 12 C out 7 C ) Cooling capacity 235 277 299 kw Power input 87.3 104.0 111.0 kw EER 2.69 2.66 2.69 W/W ESEER 3.86 3.85 3.89 W/W Water flow rate plant side 11.3 13.4 14.4 l/s Pressure drops plant side 54 60 53 kpa Cooling A35W7 ( source : air in 35 C d.b. / plant : water in 12 C out 7 C ) Cooling capacity 226 268 289 kw Power input 85.3 101.1 108.0 kw EER 2.65 2.65 2.68 W/W ESEER 3.76 3.76 3.80 W/W Water flow rate plant side 10.9 12.9 13.9 l/s Pressure drops plant side 50 56 49 kpa Heating A7W45 ( source : air in 7 C d.b. 6 C w.b. / plant : water in 40 C out 45 C ) Heating capacity 252 300 319 kw IP Power input 86.4 102.3 109 kw COP 2.92 2.93 2.93 W/W Water flow rate plant side 11.9 14.2 15.1 l/s Pressure drops plant side 60 67 58 kpa Data declared Heating according A2W45 to ( source EN 14511. : air in The 2 C d.b. values 1 C are w.b. referred / plant : water to units in 40 C without 45 C options ) and accessories. Heating capacity 213 252 270 kw NET NOMINAL Power input performances - Base setting up 73.9 (AB) - Standard plants 86.4 93.3 kw COP 2.57 2.57 2.57 W/W Water flow rate plant side 11.2 13.3 14.2 l/s Pressure drops plant side 53 59 52 kpa Heating A2W45 ( source : air in 2 C d.b. 1 C w.b. / plant : water in 40 C out 45 C ) Data Dati dichiarati declared secondo according EN to 14511. EN 14511. I valori The si values riferiscono are referred ad unità to prive units di without eventuali options opzioni and o accessories. accessori. Heating capacity 213 252 270 kw IP Power input 73.9 86.4 93.3 kw COP 2.57 2.57 2.57 W/W Water flow rate plant side 11.2 13.3 14.2 l/s Pressure drops plant side 53 59 52 kpa Data declared according to EN 14511. The values are referred to units without options and accessories. EER (Energy Efficiency Ratio) = ratio of the total cooling capacity to the effective power input of the unit ESEER (European Seasonal Energy Efficiency Ratio) COP (Coefficient Of Performance) = ratio of the total heating capacity to the effective power input of the unit HRE (Heat Recovery Efficiency) = ratio of the total capacity of the system (heating plus cooling capacity) to the effectice power input 14

TECHNICAL DATA AND PERFORMANCE - BASE VERSION (VB) NET NOMINAL performances - Base setting up (AB) - Radiant plants IR Cooling A35W18 ( source : air in 35 C d.b. / plant : water in 23 C out 18 C ) Cooling capacity 299 353 381 kw Power input 94.3 112 119 kw EER 3.17 3.15 3.20 W/W Water flow rate plant side 14.5 17.1 18.5 l/s Pressure drops plant side 89 98 87 kpa IP Cooling A35W18 ( source : air in 35 C d.b. / plant : water in 23 C out 18 C ) Cooling capacity 288 341 368 kw Power input 91.9 109 116 kw EER 3.13 3.13 3.17 W/W Water flow rate plant side 13.9 16.5 17.8 l/s Pressure drops plant side 82 91 81 kpa Heating A7W35 ( source : air in 7 C d.b. 6 C w.b. / plant : water in 30 C out 35 C ) Heating capacity 255 302 323 kw Power input 69.8 82.6 88.0 kw COP 3.65 3.66 3.67 W/W Water flow rate plant side 12.0 14.3 15.3 l/s Pressure drops plant side 61 68 60 kpa Heating A2W35 ( source : air in 2 C d.b. 1 C w.b. / plant : water in 30 C out 35 C ) Heating capacity 215 256 273 kw Power input 69.0 81.6 87.0 kw COP 3.12 3.14 3.14 W/W Water flow rate plant side 11.3 13.4 14.4 l/s Pressure drops plant side 54 60 53 kpa Data declared according to EN 14511. The values are referred to units without options and accessories. EER (Energy Efficiency Ratio) = ratio of the total cooling capacity to the effective power input of the unit ESEER (European Seasonal Energy Efficiency Ratio) COP (Coefficient Of Performance) = ratio of the total heating capacity to the effective power input of the unit HRE (Heat Recovery Efficiency) = ratio of the total capacity of the system (heating plus cooling capacity) to the effectice power input 15

TECHNICAL DATA AND PERFORMANCE - BASE VERSION (VB) NET NOMINAL performances - Low noise setting up (AS) - Standard plants - EUROVENT certified data IR Cooling A35W7 ( source : air in 35 C d.b. / plant : water in 12 C out 7 C ) Cooling capacity 228 270 291 kw Power input 92.0 109 116 kw EER 2.48 2.48 2.51 W/W ESEER 3.71 3.74 3.74 W/W Water flow rate plant side 11.0 13.0 14.0 l/s Pressure drops plant side 51 57 50 kpa Cooling A35W7 ( source : air in 35 C d.b. / plant : water in 12 C out 7 C ) Cooling capacity 219 260 280 kw Power input 90.0 106 113 kw EER 2.43 2.45 2.48 W/W ESEER 3.60 3.61 3.64 W/W Water flow rate plant side 10.6 12.5 13.5 l/s Pressure drops plant side 47 52 47 kpa Heating A7W45 ( source : air in 7 C d.b. 6 C w.b. / plant : water in 40 C out 45 C ) Heating capacity 242 288 306 kw IP Power input 81.6 96.9 103 kw COP 2.97 2.97 2.97 W/W Water flow rate plant side 11.5 13.6 14.5 l/s Pressure drops plant side 56 62 54 kpa Data declared Heating according A2W45 to ( source EN 14511. : air in The 2 C d.b. values 1 C are w.b. referred / plant : water to units in 40 C without 45 C options ) and accessories. Heating capacity 213 252 270 kw Power input 73.9 86.4 93.3 kw NET NOMINAL performances - Low noise setting up (AS) - Standard plants COP 2.60 2.60 2.60 W/W Water flow rate plant side 11.2 13.3 14.2 l/s Pressure drops plant side 53 59 52 kpa Heating A2W45 ( source : air in 2 C d.b. 1 C w.b. / plant : water in 40 C out 45 C ) Data Dati dichiarati declared Heating secondo capacity according EN to 14511. EN 14511. I valori The si values riferiscono 213 are referred ad unità to prive units di without eventuali options 252opzioni and o accessories. accessori. 270 kw IP Power input 73.9 86.4 93.3 kw COP 2.60 2.60 2.60 W/W Water flow rate plant side 11.2 13.3 14.2 l/s Pressure drops plant side 53 59 52 kpa Data declared according to EN 14511. The values are referred to units without options and accessories. EER (Energy Efficiency Ratio) = ratio of the total cooling capacity to the effective power input of the unit ESEER (European Seasonal Energy Efficiency Ratio) COP (Coefficient Of Performance) = ratio of the total heating capacity to the effective power input of the unit HRE (Heat Recovery Efficiency) = ratio of the total capacity of the system (heating plus cooling capacity) to the effectice power input 16

TECHNICAL DATA AND PERFORMANCE - BASE VERSION (VB) NET NOMINAL performances - Low noise setting up (AS) - Radiant plants IR Cooling A35W18 ( source : air in 35 C d.b. / plant : water in 23 C out 18 C ) Cooling capacity 290 343 370 kw Power input 99.5 117 125 kw EER 2.93 2.93 2.96 W/W Water flow rate plant side 14.1 16.6 17.9 l/s Pressure drops plant side 84 92 82 kpa IP Cooling A35W18 ( source : air in 35 C d.b. / plant : water in 23 C out 18 C ) Cooling capacity 279 331 357 kw Power input 96.9 114 122 kw EER 2.88 2.90 2.93 W/W Water flow rate plant side 13.5 16.0 17.2 l/s Pressure drops plant side 77 86 76 kpa Heating A7W35 ( source : air in 7 C d.b. 6 C w.b. / plant : water in 30 C out 35 C ) Heating capacity 244 289 310 kw Power input 66.1 78.1 82.8 kw COP 3.70 3.71 3.73 W/W Water flow rate plant side 11.6 13.7 14.7 l/s Pressure drops plant side 57 63 55 kpa Heating A2W35 ( source : air in 2 C d.b. 1 C w.b. / plant : water in 30 C out 35 C ) Heating capacity 215 256 273 kw Power input 68.3 80.7 86.1 kw COP 3.16 3.16 3.17 W/W Water flow rate plant side 11.3 13.4 14.4 l/s Pressure drops plant side 54 60 53 kpa Data declared according to EN 14511. The values are referred to units without options and accessories. EER (Energy Efficiency Ratio) = ratio of the total cooling capacity to the effective power input of the unit ESEER (European Seasonal Energy Efficiency Ratio) COP (Coefficient Of Performance) = ratio of the total heating capacity to the effective power input of the unit HRE (Heat Recovery Efficiency) = ratio of the total capacity of the system (heating plus cooling capacity) to the effectice power input 17

TECHNICAL DATA AND PERFORMANCE - BASE VERSION (VB) NET NOMINAL performances - Exta low noise setting up (AX) - Standard plants - EUROVENT certified data IR Cooling A35W7 ( source : air in 35 C d.b. / plant : water in 12 C out 7 C ) Cooling capacity 223 264 285 kw Power input 94.0 111 118 kw EER 2.37 2.38 2.42 W/W ESEER 3.78 3.77 3.83 W/W Water flow rate plant side 10.8 12.7 13.7 l/s Pressure drops plant side 49 54 48 kpa Cooling A35W7 ( source : air in 35 C d.b. / plant : water in 12 C out 7 C ) Cooling capacity 215 255 274 kw Power input 92.0 108 116 kw EER 2.34 2.36 2.36 W/W ESEER 3.69 3.71 3.71 W/W Water flow rate plant side 10.4 12.3 13.2 l/s Pressure drops plant side 46 51 45 kpa Heating A7W45 ( source : air in 7 C d.b. 6 C w.b. / plant : water in 40 C out 45 C ) Heating capacity 240 285 302 kw IP Power input 79 94 100 kw COP 3.04 3.03 3.02 W/W Water flow rate plant side 11.4 13.5 14.3 l/s Pressure drops plant side 55 61 52 kpa Data declared Heating according A2W45 to ( source EN 14511. : air in The 2 C d.b. values 1 C are w.b. referred / plant : water to units in 40 C without 45 C options ) and accessories. Heating capacity 219 260 278 kw NET NOMINAL Power input performances - Exta low noise setting 71.7 up (AX) - Standard plants 83.8 90.5 kw COP 80 94 100 W/W Water flow rate plant side 11.5 13.7 14.6 l/s Pressure drops plant side 56 63 54 kpa Heating A2W45 ( source : air in 2 C d.b. 1 C w.b. / plant : water in 40 C out 45 C ) Data Dati dichiarati declared secondo according EN to 14511. EN 14511. I valori The si values riferiscono are referred ad unità to prive units di without eventuali options opzioni and o accessories. accessori. Heating capacity 219 260 278 kw IP Power input 71.7 83.8 90.5 kw COP 80 94 100 W/W Water flow rate plant side 11.5 13.7 14.6 l/s Pressure drops plant side 56 63 54 kpa Data declared according to EN 14511. The values are referred to units without options and accessories. EER (Energy Efficiency Ratio) = ratio of the total cooling capacity to the effective power input of the unit ESEER (European Seasonal Energy Efficiency Ratio) COP (Coefficient Of Performance) = ratio of the total heating capacity to the effective power input of the unit HRE (Heat Recovery Efficiency) = ratio of the total capacity of the system (heating plus cooling capacity) to the effectice power input 18

TECHNICAL DATA AND PERFORMANCE - BASE VERSION (VB) NET NOMINAL performances - Extra low noise setting up (AX) - Radiant plants IR Cooling A35W18 ( source : air in 35 C d.b. / plant : water in 23 C out 18 C ) Cooling capacity 284 336 363 kw Power input 101 120 127 kw EER 2.81 2.80 2.86 W/W Water flow rate plant side 13.8 16.3 17.6 l/s Pressure drops plant side 80 89 79 kpa IP Cooling A35W18 ( source : air in 35 C d.b. / plant : water in 23 C out 18 C ) Cooling capacity 274 325 349 kw Power input 98.1 116 125 kw EER 2.80 2.80 2.79 W/W Water flow rate plant side 13.3 15.7 16.9 l/s Pressure drops plant side 75 82 73 kpa Heating A7W35 ( source : air in 7 C d.b. 6 C w.b. / plant : water in 30 C out 35 C ) Heating capacity 242 286 306 kw Power input 63.7 75.5 80.2 kw COP 3.78 3.81 3.83 W/W Water flow rate plant side 11.5 13.5 14.5 l/s Pressure drops plant side 56 61 54 kpa Heating A2W35 ( source : air in 2 C d.b. 1 C w.b. / plant : water in 30 C out 35 C ) Heating capacity 222 263 282 kw Power input 66.0 78.0 83.2 kw COP 3.36 3.37 3.40 W/W Water flow rate plant side 11.7 13.8 14.8 l/s Pressure drops plant side 58 64 56 kpa Data declared according to EN 14511. The values are referred to units without options and accessories. EER (Energy Efficiency Ratio) = ratio of the total cooling capacity to the effective power input of the unit ESEER (European Seasonal Energy Efficiency Ratio) COP (Coefficient Of Performance) = ratio of the total heating capacity to the effective power input of the unit HRE (Heat Recovery Efficiency) = ratio of the total capacity of the system (heating plus cooling capacity) to the effectice power input 19

TECHNICAL DATA AND PERFORMANCE - BASE VERSION (VB) COOLING performances The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions. For the "Operation limits" of the unit refer to the section limits. The reference nominal condition is: A35W7 (source : air in 35 C d.b. / plant : water in 12 C out 7 C) Cooling capacity 1.6 1.5 1.4 1.3 G F E D C B A Outlet air temperature ( C D.B.) A = 20 C B = 25 C C = 30 C D = 35 C E = 40 C F = 45 C G = 50 C 1.2 1.1 1.0 A35W7 0.9 0.8 0.7 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Outlet water temperature [ C] Total power input 1.4 1.3 G F E D C B A Outlet air temperature ( C D.B.) A = 20 C B = 25 C C = 30 C D = 35 C E = 40 C F = 45 C G = 50 C 1.2 1.1 1.0 A35W7 0.9 0.8 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Outlet water temperature [ C] The standard performances refer to a 5 C temperature difference between the water entering and leaving the heat exchanger and to operation of the unit with all fans at nominal or maximum speed. A 0.44 x 10-4 m 2 K/W fouling factor has also been considered with the unit installed at zero meters above sea level (Pb = 1013mbar). 20

TECHNICAL DATA AND PERFORMANCE - BASE VERSION (VB) HEATING performances The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions. For the "Operation limits" of the unit refer to the section limits. The reference nominal condition is: A7W45 (source : air in 7 C d.b. 6 C w.b. / plant : water in 40 C out 45 C) Heating capacity 1.3 1.2 1.1 A B C D E F G Outlet air temperature ( C D.B. / W.B.) A = -5,5 / -6 C B = -1,3 / -2 C C = 2,8 / 2 C D = 7 / 6 C E = 10,1 / 9 C F = 13,2 / 12 C G = 16,4 /15 C 1.0 A7W45 0.9 0.8 0.7 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 Outlet water temperature [ C] Total power input 1.3 1.2 1.1 1.0 A B C D E F G Outlet air temperature ( C D.B. / W.B.) A = -5,5 / -6 C B = -1,3 / -2 C C = 2,8 / 2 C D = 7 / 6 C E = 10,1 / 9 C F = 13,2 / 12 C G = 16,4 /15 C A7W45 0.9 0.8 0.7 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 Outlet water temperature [ C] The standard performances refer to a 5 C temperature difference between the water entering and leaving the heat exchanger and to operation of the unit with all fans at nominal or maximum speed. A 0.44 x 10-4 m 2 K/W fouling factor has also been considered with the unit installed at zero meters above sea level (Pb = 1013mbar). NOTE For air temperatures of less than 7 C, the heating capacity is declared without considering the effect of the defrosting, strictly correlated with the humidity in the outdoor air. 21

TECHNICAL DATA AND PERFORMANCE - BASE VERSION (VB) Correction factor for the use of glycol in heating mode ETHYLENE GLYCOL with water produced between 30 55 º C. Percentage Of glycol in mass / volume 0 / 0 10 / 8,9 20 / 18,1 30 / 27,7 40 / 37,5 Freezing point [ C] 0-3,2-8 -14-22 CCPT - Heating capacity 1,000 0,995 0,985 0,975 0,970 CCPA - Power input 1,000 1,010 1,015 1,020 1,030 CCQA - Water flow rate 1,000 1,038 1,062 1,091 1,127 CCDP - Water pressure drop 1,000 1,026 1,051 1,077 1,103 PROPYLENE GLYCOL with water produced between 30 55ºC. Percentage Of glycol in mass / volume 0 / 0 10 / 9,6 20 / 19,4 30 / 29,4 40 / 39,6 Freezing point [ C] 0-3,3-7 -13-21 CCPT - Heating capacity 1,000 0,990 0,975 0,965 0,955 CCPA - Power input 1,000 1,010 1,020 1,030 1,040 CCQA - Water flow rate 1,000 1,018 1,032 1,053 1,082 CCDP - Water pressure drop 1,000 1,026 1,051 1,077 1,103 Based on DESIGN CONDITIONS extract Heating Capacity (kwt r ). Based on type and percentage of glycol extract CCPT, CCQA, CCDP. Then calculate. Pt_brine = kwt r x CCPT Pass_CP_brine = kwa x CCPA Then calculate brine flow rate to the heat recovery exchanger: Q_brine [l/s]=ccqa x (Pt_brine [kw]*0.86/ T_brine)/3.6 where ΔT_brine is the temperature difference outlet-intlet heat recovery exchanger: T_brine=Twout_brine-Twin_brine With this brine flow rate enter in abscissa on the water pressure drop of the heat recovery then you have Dp_app. Finally you can calculate the actual pressure drop of the brine on heat recovery: Dp_brine =CCDP x Dp_app 22