Supplement to operating and installation manual no for the VR 81 remote control unit

Similar documents
For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430

Operating and Installation Manual VRC 430f. Weather compensator controller with radio transmission. For the operator / for the heating engineer

VR 90 Remote control unit

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

For the heating engineer. Installation manual. Interface 0-10V VR34

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Mixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Operating instructions

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

For the owner. Operating manual. ecotec. Gas wall boilers with condensing appliance technology VU 466/4 VU 656/4

Operating instructions

BM Programming Module. For the heating engineer Installation instructions

For heating engineer/user. Operating and Installation Manual VRC 630/2. Weather compensated cascade control VRC 630

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Operating instructions

Operating instructions

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

For the owner and the heating engineer. Operating and Installation Manual. timeswitch 140. Two-channel 5/2 or 7-day full programmer

atmocraft VK 654/9-1654/9 DE/AT/GB/CZ/SK/HU/PL/HR/SI/SCG

Operating instructions

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

multimatic Operating instructions AT, BE (de), CH (de), DE VRC 700f/4

O CRC100. Comfort Room Controller (2015/01) en

multimatic Operating instructions Operating instructions For the operator AT, BE (de), CH (de), DE VRC 700f/4 Publisher/manufacturer Vaillant GmbH

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Installation and servicing instructions

Operating instructions. For the operator. Operating instructions. ecotec. Gas fired wall hung high efficiency boiler.

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

RT021 User and Installation Instructions

Room panel. for ecomax800 R or T regulators. OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v , v , v08.21.

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

FR 10 INSTALLATION & USER INSTRUCTIONS INTELLIGENT ROOM THERMOSTAT

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

PROGRAMMABLE 7-DAY RF THERMOSTAT

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Operating instructions

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Setup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2

ecotec pro Operating instructions Operating instructions For the operator GB, IE Gas-fired wall-hung high-efficiency boiler

Operating instruction. Remote control station WCM-FS /

ecotec plus New high efficiency condensing combination and system boiler ranges

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

IDL/ De Longhi Appliances via Seitz, Treviso Italia

Operating instructions

NEA SMART ROOM CONTROL UNIT. Installation and operating manual

Accessories for SMA Inverters Fan Retrofit Kit FANKIT02-10

Climapro 2. Installation. wireless room thermostat without receiver.

Installation and Instructions for Use Outdoor Sensor

ecotec plus boiler user guide

Flow Factor ~

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

CSH COMBINED STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE

Operating instructions

V-ZUG Ltd. Range hood. Levante. Operating instructions

allstor buffer cylinder Instructions for use Instructions for use For the operator Publisher/manufacturer Vaillant GmbH

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

User Manual THR870CUK Programmable Thermostat

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

NEXIUN ANALOGUE INERTIA RADIATOR, PROGRAMMABLE WITH PILOT WIRE INSTALLATION INSTRUCTIONS AND USER GUIDE NEX4PW NEX8PW NEX12PW NEX14PW

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

PANEL_RS2. Run / Standby Panel. INSTALLATION MANUAL Version 1.02 MITSUBISHI ELECTRIC FOR INSTALLERS. Page 1 of 25

Digital Electronic Thermostat With RF

EN Z Subject to change due to technical improvements! Operating instructions

Condensing Boiler RS100 Controller Training Program

Digital Room Thermostat with TPI & Delayed Start User Instructions

3-way switching valve

Coffee Machine Zia series

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Mira Platinum Wireless Controller

Coffee Machine Zia series

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

Owner s Manual & Safety Instructions

GA01HC-02. Service manual. Room Panel. Programme version 01a. Operating with GH07EA regulator for controlling electrode boilers

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Coffee Machine Siro Touch 600 series

GMA Panels with double busbar

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

L / -014L / -015L

RF Programmable Room Thermostat User Instructions

E-COMBI EVO E-SYSTEM EVO

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

200W Frostwatch Radiant Heater Operation Manual

ecomax pro High efficiency condensing boiler range for traditional systems

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Room-temperature (economy/night) unit TR 212 E

User Instructions For TopTronic RS-30

instructions OIL FILLED RADIATOR V V and V551225

Transcription:

Supplement to operating and installation manual no. 0020044392 for the VR 81 remote control unit The VR 81/2 remote control unit can be used together with the VRC 430/VRC 430f and VRC 470 compensator types. > Please follow the installation, start-up and operating instructions below. 1 2 VRC 430/VRC 430f > Please follow the operating and installation manual (no. 0020044392) supplied with the remote control unit. VRC 470 > During installation and start-up, follow the operating and installation manual (no. 0020044392) supplied with the remote control unit. > During operation, please note the following: On the VR 81/2, you can only set the target room temperature. All other settings, e.g. setting operating modes or time windows, can only be made on the VRC 470 controller. Fig. 1.1 Overview of the equipment 1 Display 2 Setting dial (turn and click) Fig. 1.2 Basic display The current room temperature is shown in the "basic display". In addition, various symbols in the display indicate maintenance and error messages. Supplement to the operating and installation manual VR 81 0020124743_00 1

Operating concept The VR 81/2 remote control unit is operated using a control that works according to the Vaillant "Turn and click" operating concept. Turn the control: changes adjustable values Click the control: confirms the value There are two operating levels: The operator level, in which you can read off and change the target room temperature, The heating engineer level, which is reserved for the heating engineer. Used for displaying and adjusting/ changing specific parameters for the heating installation. A flashing area in the display indicates parameters that can be changed. Setting the room temperature The current room temperature is displayed on the basic display. > Turn the control. The current room temperature disappears. The set target room temperature appears and flashes. You can now change the set target room temperature. > Turn the control anti-clockwise or clockwise to decrease or increase the target room temperature. The basic display reappears after five seconds. The new target room temperature is applied. Status messages and error messages 1 2 Fig. 1.3 Display overview 1 Heating appliance maintenance request or heating engineer level 2 Heating appliance fault 2 Supplement to the operating and installation manual VR 81 0020124743_00

The " " symbol appears in the display Either you are at the heating engineer level or there is a maintenance request from the heating appliance. a) The operating level for the heating engineer is shown in the display. b Caution! Malfunctions due to improper settings. Only your heating engineer can change the settings on the heating engineer level. > Do not change any settings. > Wait five minutes until the basic display automatically appears. "Err" appears in the display: Fig. 1.4 Error message There is an error on the VR 81/2 remote control unit or a communication error on the ebus. > Contact your heating engineer. b) If the symbol does not go out after five minutes, there is a maintenance request from the heating appliance. > Contact your heating engineer. The " " symbol is shown in the display There is a fault in the heating appliance. > Contact your heating engineer. Supplement to the operating and installation manual VR 81 0020124743_00 3

Supplier Manufacturer 0020124743_00 GBIE 032011 Subject to change

For the operator / for the heating engineer Operating and Installation Manual VR 81 Remote control unit for VRC 430 GB

Contents Contents Notes on the documentation... 3 1.1 Storage of the documents... 3 1.2 Symbols used... 3 1.3 Validity of the instructions... 3 1.4 Other applicable documents... 3 1.5 CE label... 4 Operating instructions 1 Appliance features... 5 2 Safety... 5 3 Instructions for operation... 6 3.1 Intended use... 6 3.2 Ambient conditions... 6 3.3 Care... 6 3.4 Factory customer service and manufacturer's guarantee... 7 3.5 Recycling and disposal... 7 4 Operation... 8 4.1 Overview operating and display front...8 4.2 Operating concept...10 4.3 Setting the target room temperature...10 4.4 Setting the operating mode... 11 4.5 Setting additional parameters... 11 4.6 Changing the target room temperature... 11 5 Status and error messages... 13 Installation instructions 6 Information on installation and operation... 14 6.1 Intended use...14 7 Safety instructions and regulations...14 8 Assembly...15 8.1 Assembly location...15 8.2 Installing the remote control unit...15 9 Electrical installation... 16 9.1 Connecting the remote control unit... 17 10 Start-up... 19 10.1 Activating/exiting the installer level...19 10.2 Setting the parameters...19 10.3 Handover to the operator...20 11 Technical data...20 2 Operating and Installation Manual VR 81 0020044392_00

Notes on the documentation Notes on the documentation The following notes are intended to help you throughout the entire documentation. Further documents apply in conjunction with this operating and installation manual. We accept no liability for any damage caused by failure to observe these instructions. 1.1 Storage of the documents Please store this operating and installation manual and all related documents in such a way that they are available whenever required. 1.2 Symbols used Observe the safety information in these operating and installation instructions when operating and installing the appliance! d Danger! Immediate risk of serious injury or death! e Danger! Danger of death by electric shock! H Attention! Danger of burning and scalding! a Caution! Potentially dangerous situation for the product and environment! h Note Useful information and tips. Symbol for a necessary task 1.3 Validity of the instructions These operating and installation instructions apply exclusively for VR 81 appliances with the following article numbers: 0020028539, 0020028541, 0020028542 For the operator: The article number of your remote control unit can be obtained from your expert technician. 1.4 Other applicable documents Please observe all operating instructions for components of the system. These operating instructions are enclosed with the relevant components of the system and additional devices. Operating and Installation Manual VR 81 0020044392_00 3

Notes on the documentation 1.5 CE label The CE label confirms that the VR 81 remote control unit complies with the fundamental requirements of the following directives. Electromagnetic compatibility directive (Guideline 89/336/EEC) Low voltage directive (Guideline 2006/95/EEC) 4 Operating and Installation Manual VR 81 0020044392_00

Operating instructions h Note Have your expert technician explain the operation of the VR 81 remote control unit once the installation is complete. This will prevent involuntary changes to the settings. Note Also read the operating manual for the VRC 430 controller. This describes how important parameters of your heating system can be adjusted (e.g. time window). An explanation of technical terms and important functions is provided in alphabetical order at the end of this document. 1 Appliance features The VR 81 remote control unit is a wired remote control unit for a heating circuit and is used in combination with the VRC 430 controller. Communication with the boiler is achieved via a 2-lead bus line (ebus). Appliance features 1 Safety 2 You can adjust or modify the main functions via the VR 81 remote control unit (operating mode, target room temperature). Only one VR 81 remote control unit can be used. Product specifications ebus interface Symbol display Operation using a single dial based on the "Turn and Click" principle - The remote control unit can be mounted separately on the wall 2 Safety The VRT 81 remote control unit must be installed by a recognised expert technician who is also responsible for ensuring that existing standards and regulations are observed. We accept no liability for any damage caused by failure to observe these instructions. Operating manual VR 81 0020044392_00 VR 81 0020044392_00 5

3 Instructions for operation 3 Instructions for operation 3.1 Intended use The VR 81 remote control unit is a state-of-the-art device which has been constructed in accordance with the standard safety regulations. Even so, inappropriate or non-intended use may adversely affect the appliance and other material assets. A mixed or unmixed heating circuit can be controlled remotely by the VRC 430 controller in conjunction with a Vaillant boiler and ebus interface using the VR 81 remote control unit. Any other use or extended use is considered to be use other than intended. The manufacturer or supplier is not liable for any resulting damage. The owner alone bears any risk. Intended use also includes observance of the operating and installation instructions and all other documents also have validity. Observe the following where the "Switch-on room temp." function for the remotely controlled heating circuit is activated at the VRC 430 controller: the VR 81 remote control unit must not be covered by furniture, curtains or other objects; all radiators in the room where the VR 81 remote control unit is fitted must be fully on. Your heating engineer will advise you whether the "switch-on room temp." is activated. 3.3 Care h Note Do not use abrasive materials or cleaning agents that could damage the operator control elements, parts of the casing or display. Clean the casing of the VR 81 remote control unit with a damp cloth. 3.2 Ambient conditions The VR 81 remote control unit may only be installed in dry rooms. 6 Operating manual VR 81 0020044392_00

Instructions for operation 3 3.4 Factory customer service and manufacturer's guarantee Vaillant Service To ensure efficient and reliable operation of your boiler it is recommended that regular servicing is carried out by your service provider. Vaillant Applied System Sales Vaillant Ltd., Unit D1 Lowfields Business Park, Elland. West Yorkshire. HX5 9DG Training Telephone 01634 292370 Fax 01634 292354 email training@vaillant.co.uk Commercial Service Telephone 0870 850 3072 Mon - Fri 8.30-17.30 Fax 01773 525 946 email aftersales@vaillant.co.uk Vaillant warranty We only grant a Vaillant manufacturers warranty if a suitably qualified engineer has installed the system in accordance with Vaillant instructions. The system owner will be granted a warranty in accordance with the Vaillant terms and conditions. All requests for work during the guarantee period must be made to Vaillant Service Solutions (0870 6060 777). 3.5 Recycling and disposal Your VR 81 remote control unit and its packaging are primarily made of recyclable raw materials. Appliance The VR 81 remote control unit and its accessories must not be disposed of in the household waste. Make sure the old appliance and any existing accessories are disposed of properly. Packaging Please leave the disposal of the transport packaging to the expert technician company that installed the appliance. Operating manual VR 81 0020044392_00 VR 81 0020044392_00 7

4 Operation 4 Operation 4.1 Overview operating and display front 1 2 3 4 5 1 7 6 2 Fig. 4.2 Overview of display Fig. 4.1 Overview of the equipment Key 1 Display 2 Dial control (Turn and Click) Key 1 Heating circuit, automatic operating mode 2 Control with reference to comfort temperature 3 Control with reference to set-back temperature or frost protection 4 Heating circuit, manual operating mode 5 Heating circuit, operating mode off 6 Appliance fault 7 Maintenance requirement, appliance 8 Operating manual VR 81 0020044392_00

Operation 4 Symbol Meaning Heating circuit, automatic operating mode (can be adjusted at the VR 81 remote control unit or the VRC 430 controller) Fig. 4.3 Basic display The current room temperature is displayed in the "Basic display". Additional symbols in the display also show the selected operating mode as well as maintenance and error messages. The meaning of the symbols is explained in Table 4.1. The operating mode is not displayed if: - the holiday function has been programmed in the VRC 430 at the operator operation level; - the floor drying function has been set in the VRC 430 at the expert technician operating level. Control with reference to comfort temperature within a programmed time window for heating (only displayed with heating circuit, automatic operating mode) Control with reference to set-back temperature within a programmed time window for heating (only displayed with heating circuit, automatic operating mode) Heating circuit, manual operating mode (can be set at the VR 81 remote control unit or at the VRC 430 controller) Heating circuit, operating mode off (can be set at the VR 81 remote control unit or at the VRC 430 controller) Appliance fault Maintenance requirement, appliance or installer level Table 4.1 Meaning of symbols Operating manual VR 81 0020044392_00 VR 81 0020044392_00 9

4 Operation 4.2 Operating concept You can operate the VR 81 remote control unit using a dial according to the Vaillant "Turn and Click" operating concept. Turn dial: change adjustable values Click dial: confirm value; select operation level/parameter There are two operation levels: - Operator operation level in which the target room temperature and operating mode can be read off, adjusted and changed; - Installer level which is reserved for expert technicians. Specific appliance parameters can be displayed and adjusted/modified at this operation level. Parameters that can be modified are indicated by a flashing area in the display. 4.3 Setting the target room temperature h Note The room target temperature cannot be displayed or modified if the holiday function or floor drying function has been activated at the VRC 430 controller or if the off operating mode has been selected. "--" appears in the display instead of the room target temperature. The current room temperature and selected operating mode are displayed in the basic display. Turn the dial. The current room temperature is no longer displayed. The target room temperature that has been set lights up and flashes. You can now change the target room temperature. Turn the dial to the left or the right to reduce or increase the target room temperature. The basic display appears again after five seconds. The modified room set target value is applied. 10 Operating manual VR 81 0020044392_00

Operation 4 4.4 Setting the operating mode h Note The operating mode cannot be displayed or modified if the holiday function or floor drying function has been activated at the VRC 430 controller. The current room temperature and selected operating mode are displayed in the basic display. Click the dial once. The operating mode that has been set lights up and flashes. Turn the dial until the required operating mode appears in the display. h Note The operating mode is represented by a symbol. The meaning of the symbols is explained in Table 4.1. Push the dial to confirm the selected operating mode, or wait for five seconds until the basic display appears again. The selected operating mode is applied. 4.5 Setting additional parameters You can only set the target room temperature and operating mode at the VR 81. All other settings, such as definition of the time window or programming of the holiday function, can only be made at the VRC 430 controller. 4.6 Changing the target room temperature If you have changed the target room temperature at the operator operation level, the new control value is applied on a provisional basis depending on the operating mode selected. Manual operating mode The room temperature is controlled with reference to the new specified value until the operating mode or value is changed. Automatic operating mode - If you modify the target room temperature outside a time window: the room temperature is controlled with reference to the new value until the next time window starts. - If you have modified the target room temperature within a time window: the room temperature is controlled with reference to the new value until the current time window elapses. Operating manual VR 81 0020044392_00 VR 81 0020044392_00 11

4 Operation Room temperature Room temperature 25 20 15 25 20 Set back temperature 1 Period 08:00 12:00 2 3 4 Time Fig. 4.4 shows a programmed time window with corresponding target room temperature (21 C). In the lower diagram, the value of the target room temperature at (1) is changed (20 C). The control system uses this target room temperature until the start of the time window. From this point (2) the control system uses the target room temperature of the time window (21 C). At (3) the target room temperature is changed (17 C). The control system uses this value up to the end of the time window (4). After the time window, the control system uses the night set back temp (15 C). (You can find more information on time windows in the operating manual of the VRC 430 controller.) 15 Period 08:00 12:00 Time Fig. 4.4 Duration of validity of target value changes (here: Target room temperature) 12 Operating manual VR 81 0020044392_00

Status and error messages 5 5 Status and error messages "Err" appears in the display: The symbol is shown in the display a) An appliance requires maintenance. Contact your expert technician. b) The display shows the expert technician operation level. a Attention! Never change the settings. This could impair the function of your heating system. h Note The display changes to the basic display automatically after five minutes. Fig. 5.1 Error message The VR 81 remote control unit has developed a fault or a communication error has occurred on the ebus. Contact your heating engineer. The symbol is shown in the display The appliance has developed a fault. Contact your heating engineer. Operating manual VR 81 0020044392_00 VR 81 0020044392_00 13

6 Information on installation and operation 7 Safety instructions and regulations Installation instructions 6 Information on installation and operation The installation, electrical connection, settings at the appliance and initial commissioning may only be carried out by a recognised expert technician. 6.1 Intended use The VR 81 remote control unit is a state-of-the-art device which has been constructed in accordance with the standard safety regulations. However, in the event of improper use or use not as intended, impairment of the equipment and other items can arise. A mixed or unmixed heating circuit can be controlled remotely by the VRC 430 controller in conjunction with a Vaillant boiler and ebus interface using the VR 81 remote control unit. Communication with the controller is achieved via a 2-lead bus line (ebus). Only one VR 81 remote control unit can be used. Any other use or use that goes beyond this defined scope is considered not to be use as intended. The manufacturer or supplier is not liable for any resulting damage. The owner alone bears any risk. Intended use also includes observance of the Operating and Installation Manual as well as all other applicable documents. 7 Safety instructions and regulations The VR 81 remote controlled unit must be installed by a recognised expert technician company that is also responsible for ensuring that existing standards and regulations are observed. We accept no liability for any damage caused by failure to observe these instructions. Use commercially available cables for the wiring. - Minimum cross-sections of lines: 0.75 mm 2 The following maximum cable lengths must not be exceeded: - Bus lines: 300 m 230 V connection lines and bus lines that are more than 10 m in length must be routed separately. The VR 81 remote control unit may only be installed in dry rooms. Free terminals at the appliances must not be used as support terminals for additional wiring. 14 Installation instructions VR 81 0020044392_00

7 Safety instructions and regulations 7 Assembly 8 All wiring must be in accordance with Building Regulations Part P and BS 7671 (IEE Wiring Regulations), and must be carried out by a suitably qualified person. 8.2 Installing the remote control unit 8 Assembly 8.1 Assembly location 1 2 3 Fig. 8.2 Opening the remote control unit 1,5 m Key 1 Casing cover 2 Snap arm 3 Casing socket The connection with the boiler is achieved via a 2-lead bus line (ebus). To open the remote control unit, release the snap arm (2) on the underside, fold the casing cover (1) up and remove it from the casing socket (3). Fig. 8.1 Select assembly location Installation instructions VR 81 0020044392_00 15

8 Assembly 9 Electrical installation Fig. 8.3 Mounting the remote control unit Key 1 Snap arm 2 Fixing holes 3 Casing socket 4 Cable duct Drill two fixing holes (2) with a diameter of 6 mm and insert the supplied anchor plugs. Insert the connection cable through the cable duct (4). Fasten the casing socket (3) to the wall using the two screws supplied. 1 2 3 4 Connect the connection cable as described in Section 9. To close the casing, place the top edge of the casing cover in the snap arms (1) fold it down and press on until it engages with the casing socket. 9 Electrical installation The electrical connection must be established by a recognised expert technician who is also responsible for ensuring that existing standards and guidelines are complied with. e Danger! Immediate risk of serious injury or death! Voltage carrying connections! When carrying out work on the open control cabinet of the appliance there is a danger of potentially fatal electric shock. Switch off the power supply and prevent it from being unintentionally switched back on before carrying out work on the VR 81 remote control unit and inside the electronic box of the appliance. If the casing of the VR 81 remote control unit is closed, open it as described in Section 8.2. 16 Installation instructions VR 81 0020044392_00

9.1 Connecting the remote control unit Communication with the boiler is achieved via a 2-lead bus line (ebus). The ebus can be connected to the VR 81 remote control unit via a branch at any desired location in the ebus system (see Fig. 9.1). 1 Assembly 8 Electrical installation 9 2 3 4 Fig. 9.1 System schematic Establishing connection between ebus and system Installation instructions VR 81 0020044392_00 17

9 Electrical installation Key 1 Controller VRC 430 2 Remote control unit VR 81 3 Appliance 4 ebus connection (2-lead) Carry out the wiring for the connection of the VR 81 remote control unit in accordance with Fig. 9.2. h Note The cable for the e-bus connection is not included in the scope of delivery. - BUS + 7 8 9 VR 81 L N 3 4 5 When connecting the 2-lead ebus the lines can be swapped without adversely affecting communication (see Fig. 9.2). Also observe the manual for the appliance. - + 7 8 9 L N 3 4 5 Boiler Fig. 9.2 Electrical connection h Note Free terminals on the appliances must not be used as support terminals for additional wiring. To close the casing, place the top edge of the casing cover in the snap arms (4, Fig. 8.3) fold it down and press on until it audibly engages with the casing socket. 18 Installation instructions VR 81 0020044392_00

Electrical installation 9 Start-up 10 10 Start-up Start-up must be carried out in accordance with the assignment of the remote control unit to the heating circuit. h Note The VR 81 remote control unit is assigned to the heating circuit at the installer level in the VR 81 remote control unit. Section 10.1 describes how you can do this. 10.2 Setting the parameters Setting the address for the heating circuit A separate address is assigned to each heating circuit. If the VR 81 remote control unit is used in conjunction with the VRC 430 controller, only the addresses for heating circuit 1 = A1 or heating circuit 2 = A2 can be selected. The installer level appears in the display. The address of the remotely controlled heating circuit is displayed and flashes (standard: A1). 10.1 Activating/exiting the installer level Press the dial for roughly 10 seconds to access the installer level. The symbol is shown in the display. Press the dial for five seconds to exit the installer level, or wait for five minutes until the basic display reappears automatically. Fig. 10.1 Specifying the address for the heating circuit Turn the dial to change to the next address. The basic display reappears after five minutes if no further input is made. The selected address is used. Installation instructions VR 81 0020044392_00 19

10 Start-up 11 Technical data Adjusting the display for current room temperature at the VR 81 Press the dial. The specified offset value flashes in the display (standard: 0.0 C). 10.3 Handover to the operator The operator must be instructed in the handling and functions of the remote control unit. Hand manuals and documents for the appliance over to the operator for safe keeping. Go through the operating manual with the operator and answer any questions if necessary. Make sure that the operator is knows about safety information that must be observed. 11 Technical data Fig. 10.2 Setting the offset value Turn the dial to change the offset value. The offset value has a range of between -3.0 C and +3.0 C and can be adjusted in 0.5 C increments. The standard value is 0.0 C. The basic display reappears after five minutes if no further input is made. The modified parameters are applied. Nomenclature Unit Value Operating voltage U max V 24 Maximum permissible ambient temperature C 50 Current consumption ma 17 Minimum cross-section of connection lines mm 2 0.75 Level of protection IP 20 Protection class for controller III Dimensions Height mm 97 Width mm 97 Depth mm 27 Table 11.1 Technical data 20 Installation instructions VR 81 0020044392_00

0020044392_00 GB 102007