Reaction Unit. Fractional Distillation Unit. Filter Unit. Synthesizer STANDARD UNITS

Similar documents
STANDARD UNITS INTRODUCTION

Borosilicate 3.3 Glass Pilot plants / Equipment

Shyam Enterprises 9 PACKAGE UNIT

5 HEAT EXCHANGER PROCESS PLANT COMPONENTS. P 305 e.3. Copyright 2007, QVF Engineering GmbH. All rights reserved.

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

Operation Manual R205BV, R209BV

:57: of 15 pages

Arrangements of cold exchangers or cold accumulators in cryogenic separation or liquefaction plants.

Development Centre for Evaporation and Thermal Separation Technologies

No matter how adventurous a process engineer may

Top performance when the going gets tough

Order by phone Order on-line Order by fax Website

Evaporation studied on a duplicated vessel, pilot scale evaporator equipped with a heat pump

The Liquid Manufacturing Plants are ideal tools for the pharmaceutical industry and food industry for the production of Oral Liquids.

ABOUT SIGMA OUR MISSION

Short Path Distillation Unit. KDL 1 BASIC Version 2015

In order to be useful, many substances must be available in pure form.

Chemical engineering range - 11/01 MULTI-FUNCTION DISTILLATION DVI/6000. Version presented DVI/6000 PIGNAT S.A.S. Subject to technical modifications

POWERVAP - EX GENSER NOW AVAILABLE. High performance PTFE-sealings for all glass connectors. Fully automated rotary evaporators

Evaporators. In this section. Rotary Evaporators Crystalisation Distillation Drying Reflux Solution Concentration Volatiles Glassware

NEOTeCHA Reactor Sampling Type PV

M/s N. K. Joshi & Co. Manufacturers of Electrical Heating Appliances for Chemical Laboratories.

DELAYED COKER UNIT (DCU)

B/R 9600 Steel Fractional Distillation Systems. Fractional Distillation for the Laboratory and Industry

Pneumatic Vacuum Conveyors for the Highest Standards Transportation of bulk materials in the pharmaceutical and chemical industries

PIPING SYSTEM EQUIPMENTS

HEAT EXCHANGERS. Heat Exchangers are available in 2 basics designs: 1. Conventional Coil Type Condensers. 2. Shell & Tube Type.

Reactor-Ready Du. Lab Reactors Patent Pending.

BOILER HOUSE PRODUCTS GMS

Heidolph Vacuum System. Heidolph Vacuum System. Vacuum pumps. Vacuum accessories. ROTAVAC valve control. VAC control automatic. ROTAVAC vario control

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

160 EXTRACTION. Liquid/Liquid Extraction Apparatus. Continuous Liquid/Liquid Extraction with Built-in SLOW-DRY Concentrator

Reactor-Ready Pilot. Lab Reactor. Innovative reaction work station for glass reaction vessels from 5 to 20 litres

EQUIPMENT LIST gallon Pfaudler glasteel jacketed reactor rated at 90psi/FV. Variable frequency drive agitator, 200 ft 2 Graphilor condenser.

Points to be Considered when Purchasing a Steam Jet Vacuum Pump

ENERGY OPTIMIZATION IN THE MAA GAS PROCESSING FACILITIES

SPECIALIZED EQUIPMENT

SOFTWARE DEVELOPMENT FOR MECHANICAL DESIGN OF SHELL AND TUBE HEAT EXCHANGER

Fluid Bed Processor LFP LÖDIGE ALWAYS THE RIGHT MIX

The Condensate Water Systems

Rotary Evaporators, Heidolph

Premium Laboratory Equipment. Chem Tools

Jet Vacuum Systems. GEA Wiegand GmbH

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

Condensate Recovery and Return System SDR A

Evaporators, Rotary. Total concentration... technology and performance in harmony 13

Function of the FENIX Hydrodynamic Trap working on Variable Load Applications

Where we are Aurum Process Technology has its headquarters in Murcia (Spain).

B/R 9600 Packed Column Distillation Systems. Fractional Distillation for the Laboratory and Industry

Vacuum Booster for Distillation Process

Immersion Heat Exchanger. Thermosyphon Reboiler. Coil Condenser. Boiler

TMCI Padovan Evaporators

Shell and tube heat exchanger

Efficient Steam System Design

24 position personal synthesiser for parallel solution phase and solid supported reagent based chemistry

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

Packaged Steam Fired Water Heater

DOLPHIN FRESH WATER SHELL AND TUBE EVAPORATOR

Distillation Systems for Solvent Recycling

Brazed Plate Heat Exchanger for CO Applications

Fractional Distillation for the Laboratory and Industry

Rotary Evaporators, Heidolph

Dry, oilfree Diaphragm Pumps

Dry, oilfree Diaphragm Pumps. Highlight NEW MPC 302 Z. 3 Diaphragm Pumps

By: Prof K. M. Joshi,

Volkmann Vacuum Conveying Applications

ANNEX 6. Refinery No. 1 New Area. Problems Existing in the Current Condensate Return System of the New Area of Refinery No.1

International Association of Certified Practicing Engineers

1. Know your process. The following guidelines will help you navigate what can be a challenging and time consuming task.

Each unit is also provided with an easy to use Can be orientated for left or right handedness


Thermal Fluid Heaters

Beverage Processing System

Rotary Evaporator Replacement Glassware

Weighing Balances. Hot Plate. Laboratory Oven. Muffle Furnace. Loss On Heating Oven COMMERCIAL EQUIPMENTS. General / Special Purpose Equipment

Shop. Item Information. Rotavapor R-300 B-305, SJ24/40, C, P+G, WB, 110V. Send item information. Show item in shop. Add item to cart.

LÖDIGE ALWAYS THE RIGHT MIX

Rotary Evaporators designed

PIONEERS IN AIR VACUUMS

Equipment for Research Analysis Process Education. page J13. page J3, J3, J4. page J14, J15, J16. page J8, J9, J10. page J5. page J10, J22.

Verd_GB_ FH :22 Uhr Seite 1 C M Y CM MY CY CMY K Rotary Evaporators Probedruck

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Products & Application

LÖDIGE ALWAYS THE RIGHT MIX

Introduction to Control Technology

MSMCR. Counter-Rotating Blenders. I Application. I Principle of operation

4310 N. 126th Street Brookfield, WI (USA) Phone: (262) ~ Fax: (262)

Verd_GB_ :55 Uhr Seite 1 C M Y CM MY CY CMY K Rotary Evaporators Probedruck

1 L Rotary Vacuum Evaporator Instruction Manual

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

PMS - Multi-shaft Vacuum Mixer

Alfa Laval spiral heat exchangers

For the successful distillation of heat sensitive materials

Rotary Evaporator Replacement Glassware

Evaporation Technology

FloCon Commissioning Modules Fan coil and chilled beam headers Patent No. GB B

MANUFACTURERS OF: INSTRUMENTS & SERVICES. Page:01

PILOT-15 CENTRIFUGAL MOLECULAR DISTILLATION SYSTEM

Vacuum in the laboratory. products and solutions

Metering & Thrust Gear Pumps. apompe.eu

Transcription:

eaction Unit Filter Unit Synthesizer Fractional Distillation Unit INTODUCTION Standard Units/ Assemblies are multi-purpose units having flexibility of utility. These units have been standardized by incorporating all basic & essential features such as heating, stirring, condensation, fractionation, cooling etc. for multi-purpose use. Therefore, though termed Standard Units from constructional view point they actually serve as Flexi Units from utility point of view. These units find use in educational institutions, &D centers and industries. They can be conveniently and quickly modified according to specific process needs due to modular construction. Borosilicate glass offers additional benefits of universal corrosion resistance, visibility and cleanliness. STANDAD UNITS 65

STANDAD UNITS 1. Glass eactor With Metal Jacket 2. S imple Distillation Unit 3. eaction Unit 4. F raction Distillation Unit 5. eaction Distillation Unit 6. Liquid-Liquid Extraction Unit 7. Solid-Liquid Extraction Unit 8. Assembly over GL 9. Flanged eactors 10. Multi Purpose Unit 11. Mobile Mixing System VENT / CONDENSE GLASS EACTO WITH METAL JACKET NEW ADDITION MOTO GLASS COVE STIE GLASS INSULATION EFLUX DIVIDE DISTILLATION COLUMN METAL JACKET PODUCT COOLE FIST ECEIVE VENT FINAL ECEIVE DAIN According to the customer's requirements and standard, we manufacture jacketed glass reactor which has many functions to satisfy kinds of experiments. Goel Scientific offers Glass eactor with Metal Jacket for chemical & pharmaceutical industries for process development. Glass reactor will have metal jacket and metal insulation. Glass / Glass Lined eactor (GL) : 5-500 liter Pressure: - up to 1 Bar Temperature: -50 C to +200 C Material: Borosilicate glass 3.3 /PTFE/ SS 316. Key Features: eactor lift for easy opening i.e optimised for easy vessel cleaning Temperature monitoring and control Gas purging available Vacuum / exhaust piping arrangement Additional feeders / receivers as per requirement Solid feeding arrangement eady for Cryogenic reactions (-50 C) Mixed systems with pressure reactor and vacuum distillation BOTTOM 66

STANDAD UNITS SIMPLE DISTILLATION UNITS It consists of a vessel mounted in a heating bath and fitted with a condenser for condensing the vapours. A receiver with drain valve can be added for receiving the condensate. VAPOU LINE The units are available in vessel sizes of 20, 50, 100, 200 & 300 L and is suitable for operation under atmospheric pressure and full vacuum. LIQUID INLET T Unit eactor Bath Vapour Condenser 2 Cat.ef. Capacity KW Line M SDU20 20 L 4.5 80 DN 0.35 SDU50 50 L 6.0 100 DN 0.50 SDU100 100 L 9.0 150 DN 1.50 SDU200 200 L 12.0 150 DN 1.50 SDU300 300 L 16.0 225 DN 2.50 HEATING BATH CONDENSE DISTILLATE OUTLET DAIN EACTION UNIT VENT / This unit is used for carrying out reactions under stirred condition and with provision for simple reflux distillation. The reaction vessel is mounted in a heating bath and fitted with addition vessel, motor-driven stirrer and provision for condensation with refluxing. The product is sub-cooled and collected in a receiver. The units are available in vessel sizes of 20, 50, 100 & 200L and is suitable for operation under atmospheric pressure and full vacuum. MOTO CONDENSE Unit eactor Bath Addition Vapour Condenser Cooler eceiver 2 2 Cat.ef Capacity KW Vessel Line HTA M HTA M Size DU20 20 L 4.5 2 L 80 DN 0.35 0.10 5L DU50 50 L 6.0 5 L 100 DN 0.50 0.20 10L DU100 100 L 9.0 10 L 150 DN 1.50 0.35 20L DU200 200 L 12.0 20 L 150 DN 1.50 0.35 20L DU300 300 L 16.0 20 L 225 DN 2.50 0.50 20L ADDITION STIE EFLUX DIVIDE PODUCT COOLE VENT / HEATING BATH ECEIVE DAIN DAIN 67

STANDAD UNITS FACTIONAL DISTILLATION UNIT CONDENSE EFLUX DIVIDE This is essentially a compact batch-type fractional distillation unit in which the reboiler consists of a vessel mounted in a heating bath and with a packed column above. The vapours from top is condensed and can be refluxed as per requirement. The top product is sub-cooled and collected in receivers. The bottom product is finally drained from the reboiler through a drain valve. The units are available in vessel sizes of 20, 50, 100 & 200L and is suitable for operation under atmospheric pressure and full vacuum FACTIONATION COLUMN PODUCT COOLE FIST ECEIVE Unit eactor Bath Addition Vapour Condenser Cooler eceiver 2 2 Cat.ef Capacity KW Vessel Line HTA M HTA M Size FDU20 20 L 4.5 2 L 80 DN 0.35 0.10 5L FDU50 50 L 6.0 5 L 100 DN 0.50 0.20 10L FDU100 100 L 9.0 10 L 150 DN 1.50 0.35 20L FDU200 200 L 12.0 20 L 150 DN 1.50 0.35 20L FDU300 300 L 16.0 20 L 225 DN 2.50 0.50 20L HEATING BATH VENT / FINAL ECEIVE DAIN DAIN VENT / EACTION DISTILLATION UNIT This is a versatile unit and can be used as eaction Distillation Unit, Fractional Distillation Unit or a combination of both. All features of eaction Distillation Unit and Fractional Distillation Unit are incorporated. CONDENSE The units are available in vessel sizes of 20, 50, 100 & 200L and is suitable for operation under atmospheric pressure and full vacuum. ADDITION MOTO EFLUX DIVIDE STIE EACTIONAL DIST.COLUMN PODUCT COOLE Unit eactor Bath Addition Vapour Condenser Cooler eceiver 2 2 Cat.ef Capacity KW Vessel Line HTA M HTA M Size FU20 20 L 4.5 2 L 80 DN 0.35 0.10 2L, 5L FU50 50 L 6.0 5 L 100 DN 0.50 0.20 5L, 10L FU100 100 L 9.0 10 L 150 DN 1.50 0.35 10L, 20L FU200 200 L 12.0 20 L 150 DN 1.50 0.35 10L, 20L FU300 300 L 16.0 20 L 225 DN 2.50 0.50 20L, 20L FIST ECEIVE HEATING BATH VENT FINAL ECEIVE DAIN DAIN 68

STANDAD UNITS LIQUID-LIQUID EXTACTION UNIT Liquid extraction, sometimes called solvent extraction, is the separation of constituents of a liquid solution by contact with another insoluble liquid. The unit described here is for a semi-batch operation. The liquid to be extracted is poured into an extraction vessel. Solvent is boiled in a reboiler vessel and condensed in an overhead condenser, the condensed liquid collecting in a reflux divider and passing through pipework to the extraction vessel. The pipework incorporates valves in order that the solvent can enter the extraction vessel at either the base of the top, depending on the relative densities of the solvent and liquid to be extracted. The solvent and the extracted liquid pass back to the reboiler and the process is repeated until the extraction is complete. The extraction vessel is then drained and the solvent evaporated from the reboiler vessel and collected in the extraction vessel enabling the two liquids to be drained from their respective vessels. VENT OVE HEAD CONDENSE EFLUX DIVIDE The units are available in vessel sizes of 10, 20 & 50L and is suitable for operation under atmospheric pressure. Unit eactor Bath Vapour Extraction Condenser 2 Cat.ef. Capacity KW Line Vessel M LLU10 10 L 3.00 40mmx1m 10 L 0.35 LLU20 20 L 4.50 50mmx1m 20 L 0.50 LLU50 50 L 6.00 80mmx1m 50 L 1.50 EXTACTION VAPOU PIPELINE BATH DAIN DAIN SOLID-LIQUID EXTACTION UNIT This operation involves preferential solublising of one or more soluble constituents (solutes) of a solid mixture by a liquid solvent. The unit described here is for a semi-batch operation. The solid to be extracted is put inside a glass fiber bag and placed in an extraction vessel. Solvent from the reboiler is continuously evaporated, condensed and circulated through a reflux divider by means of piping network and valves. When desired/ steady concentration of solute is achieved in the solution the operation is discontinued. The solution is drained off and collected for further use. VENT OVE HEAD CONDENSE EFLUX DIVIDE After charging fresh solid in fiber bag and solvent in reboiler, the cycle can be restarted again. The units are available in vessel sizes of 10, 20 & 50L and is suitable for operation under atmospheric pressure. Unit eactor Bath Vapour Extraction Condenser 2 Cat.ef. Capacity KW Line Vessel M EXTACTION CONTAINING FIBE BAG VAPOU PIPELINE SLU10 10 L 3.00 40mmx1m 10 L 0.35 SLU20 20 L 4.50 50mmx1m 20 L 0.50 SLU50 50 L 6.00 80mmx1m 50 L 1.50 BATH DAIN DAIN 69

SHELL & TUBE HEAT EXCHANGE STANDAD UNITS ASSEMBLIES OVE GLASS LINED EACTO PHASE SEPAATO PODUCT COOLE Glass Lined eactors are used instead of glass reactors specially when scale of operation is large and relatively high pressure steam is to be used as heating media. Quite often assemblies like Simple Distillation Unit, eaction Distillation Unit, Fractional Distillation Unit etc. are installed above glass lined reactors. The basic features of these assemblies remain the same but glass shell and tube heat exchanger is preferred due to large scale of operation. A typical fractional distillation unit type assembly over GL is shown in adjacent figure. ECEIVE EACTO FLANGED EACTOS FLAME POOF GEAED MOTO FEQUENCY DIGITAL EGULATO Designed for use in research & development or in pilot plant operations. Our standard Flanged eactors are provided with cylindrical vessel with wide diameter. Glass Cover with Vapour Nozzle & Feed tube, Flush Bottom Valve, Extra Heating sensors for better heating, PTFE Battery, Flame-proof Electrical Heating Bath/Mantle, Glass Turbine Stirrer, Epoxy coated coupling & PTFE Gaskets. All wetted parts are made of borosilicate glass or PTFE for optimum compatibility of reactants. MECHANICAL SEAL Size : Cat.ef. DN Actual Capacity VAPOU NOZZLE VAPOU COVE VZ 25/12 300 25 Ltr VZ 50/16 400 54 Ltr VZ 100/18 450 101 Ltr VZ 200/24 600 198 Ltr LIQUID ADDITION PIPE GLASS PTFE BEFFLES 4 NOS. TUBINE STIE COOLING COIL TWO EXTA SENSOS DIGITAL TEMP. CONTOLLE 70

STANDAD UNITS MULTI PUPOSE UNIT Vacuum Catch Pot SIDE VIEW Goel Offer multipurpose pilot plant for chemical and pharmaceutical industries for process development, scale-up, process simulation and kiloscale cgmp production in batch and semi-batch operation. The pilot plant used for chemical processing includes solid charging, liquid charging, reaction, heating / cooling, rectification, auto / manual reflux arrangement, layer separation, product cooler, vacuum catch pot, vacuum header etc. The multipurpose pilot plant designed in such a way that we can modify the same easily as per process requirement. Available with Jacketed full glass reactor/ Cylindrical full glass reactor with Oil heating cooling bath / Spherical full glass reactor with Oil heating cooling bath Multipurpose glass distillation overhead Stainless steel / MS epoxy coated / MS painted frame supporting Flame proof / Non flame proof / cgmp / non GMP models available Excellent corrosion resistant. Temp. Controller. Gas purging, solid charging / multi liquid addition. Vacuum / exhaust piping Additional feeders / receivers Solid feeding Unit eaction Bath KW Addition Vapour Condenser Cooler eceiver Cat. ef. Capacity Vessel Line HTA m2 HTA m2 Size MPU 20 20 L 4.5 2 L 80 DN 0.35 0.10 2L, 5L MPU 50 50 L 6.0 5 L 100 DN 0.50 0.20 5L, 10L MPU 100 100 L 9.0 10 L 150 DN 1.50 0.35 10L, 20L MPU 200 200 L 12.0 20 L 150 DN 1.50 0.35 10L, 20L MPU 300 300 L 16.0 20 L 225 DN 2.50 0.50 20L, 20L 71

MOTO STANDAD UNITS MOBILE'MIXING SYSTEM Glass eactors are ideally used for wide applications in laboratory, pilot plant & for small-scale production. They reduce the need for investment in permanent installations & also reduce the pressure & temperature losses resulting from pipeline installation. STIE PTFE BELLOW These reactors are available with spherical shape & in cylindrical shape. These reactors are also available in cylindrical jacketed form. CLOSUE COVE LINE Cylindrical Mixing eactor Cat.ef. Vessel ef. Nominal Cap.(I) CG 20 VSL 20/9 20 CG 50 VSL 50/12 50 CG 100 VSL 100/18 100 JACKETED CG 150 VSL 100/18 150 CG 200 VSL 200/18 200 CG 300 VSL 300/24 300 HOLDE DAIN MOTO Jacketed Mixing eactor Cat.ef. Vessel ef. Nominal Cap.(I) JG 5 VZD 5/6 5 JG 10 VZD 10/9 10 STIE PTFE BELLOW JG 20 VZD 20/12 20 JG 30 VZD 30/12 30 JG 50 VZD 50/12 50 CLOSUE COVE LINE For Graduation on reactor kindly add G to the Cat. ef. that means SG 20 will be marked as SG 20/G. JACKETED Above systems are available with different options, depending upon their size & their utility. Our Technical Department will glad to assist you in finding a suitable solution for your process requirement. HOLDE BOTTOM OUTLET 1. Stirrer Drive: Non-Flameproof or Flameproof Motor, 192 PM with speed regulator. 2. Stirrer material of construction: Glass or PTFE Lined. 3. Stirrer shape: Glass Impeller Stirrer with PTFE Blades, Vortex Stirrer, propeller stirrer & anchor stirrer. 4. Stirring Assembly: Stirring Assembly with bellow seal or with mechanical seal. 5. Supporting Structure: Carbon Steel, Epoxy coated Carbon Steel, S t a i n l e s s Steel 304 & Stainless Steel 316. All structure are available in Trolley mounted form. 6. Closing Valve: Drain Valve or Flush Bottom Outlet Valve. 72