Martha s Vineyard Airport Water, Wastewater, Facilities Department Report

Similar documents
Home Set-up and Maintenance. Maintenance

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

INFLOW & INFILTRATION REPORT

NYC Department of Education

San Antonio Water System Purchasing Division Commodity Assignments

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM

SAFETY POLICY AND PROCEDURE MANUAL All Euramax Subsidiaries. Number F-2.0 Emergency Eyewash / Emergency Showers

NYC Department of Education

2 Main Office Building BLDG-955A Building Purpose Building Area Administration offices. Training room 7,610 SF Inspection Date August 16, 2016 Inspect

NYC Department of Education

VEHICLE SERVICE FACILITIES Best Management Practices

GIRTON CABINET WASHER MODEL 794A

Open Charter Magnet School Water Retention System OPERATION, MAINTENANCE & INSPECTION SUPPLEMENT October 20, 2007 Richard Haimann, P.E.

NYC Department of Education

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

7 Steps to Building the Dream Water Garden

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

Top of the World Tower

Inside Out Home Inspections

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

Appendix B. Facilities Assessment Report

CMHC HOME MAINTENANCE CHECKLIST

Coquille Indian Housing Authority Maintenance Report February 2017

NYC Department of Education

Structural Guidelines. Food Service Establishments. Retail Food Stores

Tighe&Bond. Groton Heights School Mechanical Evaluation. 1 Existing Conditions. 1.1 Water Service Entrance

NYC Department of Education

WINNEBAGO COUNTY HEALTH DEPARTMENT GUIDELINES FOR THE CHAIRPERSON FOR SAFE FOOD HANDLING AT SPECIAL EVENTS

INSTALLATION INSTRUCTIONS

ACIDS & ACID CLEANERS

Mechanical Inspection Plumbing

NYC Department of Education

PLAN REVIEW SUBMITTAL GUIDE

Beaufort County Community College. Maintenance and House Keeping Plan

NYC Department of Education

NYC Department of Education

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Home Maintenance Schedule

EXHIBIT A-1 CITY OF BELLFLOWER JANITORIAL MAINTENANCE SPECIFICATIONS

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

While most maintenance is seasonal, there are some things you should do on a frequent basis year-round:

TARRANT COUNTY PUBLIC HEALTH DEPARTMENT fax FOOD ESTABLISHMENT REVIEW APPLICATION

MONTECITO FIRE PROTECTION DISTRICT

NYC Department of Education

Web:

Axiom Property Inspections

20 gal per person per day.

Trinity River Authority of Texas

LIVINGSTON COUNTY BOARD PROPERTY COMMITTEE MINUTES OF OCTOBER 1, 2018

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

Mobile Milker. Filling the oil reservoir to HALF FULL

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

NYC Department of Education

K4600 Assembly Directions

NYC Department of Education

NYC Department of Education

4.0 SERVICES AND SCHEDULE

NYC Department of Education

NYC Department of Education

NYC Department of Education

Facility Condition Assessment Summary Report. British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building

NYC Department of Education

Bubbling Rock Fountain Installation Manual

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Winnipeg Fire Department Fire Prevention Branch

SUMMER. Over the summer, there are a number of indoor. Inspecting your home on a regular basis and. Seasonal Maintenance Schedule. For A Healthy Home

S AGE E NGINEERING A SSOCIATES, LLP

NAZARETH AREA SCHOOL DISTRICT MAINTENANCE DEPARTMENT 357 Tatamy Road, Nazareth, PA FAX

Energy problems in small apartment buildings

INSTALLATION OPERATION MAINTENANCE

What is Included with a Seasonal Service?

NYC Department of Education

Special Events Requirements. Food Protection Services

Lead in Priority Area Sampling Report Naval Air Station Patuxent River

NYC Department of Education

NYC Department of Education Building Condition Assessment Survey :49AM :00PM

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

NYC Department of Education

HHA Bellerive Apartments 7225 Bellerive Houston, Texas J. Allen Management Managing Agent

Eccotemp L5 and L10 Comprehensive Troubleshooting Guide

NYC Department of Education

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Owners Manual for the Rainmaster Water Recycling System

NYC Department of Education

Sedimentation. Photo Credit: Virginia Department of Health

NYC Department of Education

How to report a repair

Seasonal Home Maintenance Checklists

BOHEC R CRS86A DISHWASHER STANDARD FEATURES MODEL ACCESSORIES DIRECTION OF OPERATION VOLTAGE OPTIONS AT EXTRA COST

CITY OF PASADENA FIRE DEPARTMENT

User s Information Manual

101 Low-Cost /No-Cost. Home Energy-Saving Measures

NYC Department of Education

NYC Department of Education

NYC Department of Education

Food Establishment Guidelines. Food Service Plan Review

ce Is the Key Seasonal Home Maintenance Inspecting help keep live. help you. person to round: snow or debris. test button, which should then cause the

NYC Department of Education

Transcription:

Martha s Vineyard Airport Water, Wastewater, Facilities Department Report 508-693-3783 October 2017 Water, Wastewater, Facilities Department Report from Michael Eldridge, Christina Colarusso and Jeremy Osborn Wastewater Accomplishments: -Implemented use of polymer for wastewater treatment and surfactant settling which has decreased effluent turbidity and increased ultraviolet transmittance significantly Polymer Feed Pump System. Before and After clearing area for HVAC project excavation -Work has begun on process room HVAC unit, in preparation of the job, we cleared over 800lbs of debris from the work site to prepare for the excavtion crew. -Merry and Sons went right to work digging up the old equipment and concrete blocks -Procut Concret Cutting used their specilized equipment to make light work of the conrete Progression of HVAC project prep by Merry and Sons Excavation and Procut Concrete Cutting 1

Progression of HVAC project prep by Merry and Sons Excavation and Procut Concrete Cutting -Prepared the WWTP for Nelson Mechanical s complete replacement of plumbing by removing sludge vacuum bed equipment near water meter and backflow devices Removing Sludge Vacuum Bed Equipment to make room for new plumbing piping and valves -We continue to check for residual chlorine levels at the influent bar rack as wastewater enters the plant as we are still experience occasional high concentrations of chlorine and have been using dechlorinating treatment when necessary Plumbing Replacement Job by Nelson Mechanical Started 10/10 2

-Plumbing replacement job began this week by Nelson Mechanical, which includes: replacing piping that has been subjected to extremely corrosive environments, bringing current eyewash/emergency shower station up to code with tempered water and the addition of a station in the chemical storage room. The chemical storage room is subject to outside temperatures so it will be frost protected with all plumbing within the building and only the pull handles on the inside of the chemical storage room. The job also includes replacing the hot water heater and installing a circulation pump to the eyewash station, the outdoor spigots, and water meter. We were able to re-use the old ARFF building backflow prevention devices and our existing booster pump to cut costs. Hangers will be outfitted in stainless to prevent corrosion -Business Park Pump Station Generator had a large annual maintenance and load test completed by South Shore Generator -Received quote back from Saybrooke Environmental for disposal of small quantities of used reagent hazardous waste, in process of streamlining Hazardous Waste Removal Facilities Accomplishments -Replaced all Terminal Entrance Mats with Aramco Aluminum Roll Up style which will allow for easier cleaning, longer life and replaceable rug inserts Before During After -Caterpillar will be coming out in the next few weeks for a service call to replace the jacket water heater on the vault generator and attend to other maintenance items -Cleaned ice machine in the General Aviation kitchen and ordered parts to replace drain 3

-Merriman Chimney Services cleaned the boiler exhaust piping in preparation of the winter season, soliciting quotes from multiple vendors saved the airport over $3,500 Boiler Exhaust Ductwork was chimney swept and is ready for winter, as is the exhaust drain -Boiler Exhaust Drain line was re-plumbed to include a trap, bypass and the acid neutralizer was changed. The exhaust drain connection piping was fixed to be snug - Wilkinson Boiler Inc. will be out to do a cleaning and burner change out on 10/18 the current burner model is unable to get proprietary replacement parts Inside of the Oil fired Burner to be cleaned, Telephone Vault that was pumped for Brad -Pumped water from telephone vault for Brad so that he could pull communication wires -Terminal As-built Drawings were sent to McFarland Johnson for scanning and copying -Quarterly Ice Machine Maintenance completed in the General Aviation kitchen unit -Air Handler #6 Condensate Drain clogged causing an overflow and damage to ceiling panels and electrical equipment, cleaned drain and repaired damaged ceiling tiles -Ordered replacement pilot lounge door through USA Fire Door: Eight Pane, double doors Air Handler #6 Leak, Damage and Repaired 4

-Rebuilt #1 Roots Air Blower with rebuild kit, replaced bearings, seals and nuts. Painted housing and tested satisfactory. Rebuilt #1 Roots Air Blower instead of replacing and saved the Airport $1100 - F350 brakes were repaired due to failure of break line - The condenser fan motor for the Planeview A/C failed, new motor came in and was back online in three days Plainview s Air Conditioning Condenser Unit, Indicator Post for Fire Sprinkler with Potter Switch, Hose Section on Street Sweeper to be replaced -Ordered a replacement hose, extension nozzle and gutter broom replacement for Street Sweeper, extension will allow for more reach during catch basin cleaning operations -Coordinated with Glynn Electric and ESS for new ARFF Terminal Building Fire Control Panel Alarm programming and consulted with West Tisbury Building Inspector and West Tisbury Fire Chief on tamper alarm specifications -Ordered new water fountain for General Aviation Building that has a water filling station that tracks how many bottles of water it has saved from use picture of unit style to the right Water Department Accomplishments: -Completed monthly drinking water sample testing was satisfactory -Monthly water meter readings were collected and analyzed for high consumption, no abnormal conditions found this month -Continued to work with customers clarifying water bills and supplying supplemental water meter information for breakdowns 5